---
title: "AEC UPS blog: guides to uninterruptible power"
url: https://www.aecups.com/en/blog/
description: "Practical guides to UPS and central power supplies: choosing and sizing a UPS, single or three-phase, modular, batteries, maintenance, CPSS to EN 50171."
language: en
---

Blog

# Guides to uninterruptible power

How to choose, size and look after a UPS, explained by AEC's engineers: the UPS types and when online double conversion is needed, working out power and backup time, single or three-phase, lead-acid or lithium batteries, N+1 redundancy, heat and maintenance, with worked examples and the AEC ranges for EMEA.

Guides

## UPS basics

### What is a UPS and what does it do?

[UPS means uninterruptible power supply: what a UPS is, how it works, the three types, what it is used for and how to read its rating. Read](https://www.aecups.com/en/blog/what-is-a-ups/)

### Online UPS vs line-interactive vs offline: UPS types

The three UPS types compared: offline, line-interactive and online double conversion, with transfer time, VFI/VI/VFD classes and ECO mode. Read

### How to choose a UPS: type, runtime, phases and service

How to choose a UPS once its size is known: online or line-interactive, runtime and shutdown, single- or three-phase, rack or tower, and service[. Read](https://www.aecups.com/en/blog/how-to-choose-a-ups/)

### UPS vs generator: how they differ and work together

A UPS gives instant power, a generator long runtime after a start delay. How to combine them, size the generator and avoid common mistakes. Read

### UPS glossary: 87 UPS terms and acronyms explained

UPS glossary: what UPS stands for and the terms engineers use, from VFI, PF and THDi to VRLA, SNMP and EPO, each linked to a deeper guide. Read

### UPS datasheet explained: every line, with examples

How to read a UPS datasheet: UPS specifications explained section by section, from input and battery to efficiency, using a real AEC datasheet. [Read](https://www.aecups.com/en/blog/how-to-read-a-ups-datasheet/)

Guides

## Sizing and backup time

### UPS sizing: how to work out the power you need

[How to size a UPS: list the loads, convert watts to VA, keep 20% headroom in both VA and W, then pick the battery. Two worked examples and a checklist. Read](https://www.aecups.com/en/blog/ups-sizing/)

### kVA vs kW: power factor and UPS sizing explained

kVA is apparent power, kW is real power: kW = kVA × power factor. The conversions, the power factor of each AEC range and a 3 kW example. Read

### UPS backup time: how to estimate and extend runtime

UPS runtime depends on the load in watts, battery energy and discharge rate: the estimate formula, why the maker's tables matter and how to ext[end it. Read](https://www.aecups.com/en/blog/ups-backup-time/)

### UPS heat output: BTU, cooling and room temperature

UPS heat output equals its losses: load × (1/efficiency − 1), then × 3.412 for BTU/h. Worked example, battery room temperature, clearances and checklist. Read

### UPS efficiency and ECO mode: losses and energy savings

UPS efficiency explained: how losses change with load, the P × (1/η − 1) formula with a worked example, ECO mode trade-offs and how to read datasheets. Read

### UPS installation clearances: what to check on site

Clearances, operating gangways, door widths, floor load, cable entry and airflow for every AEC EMEA UPS and battery cabinet, before the delivery. Read

Guides

## Batteries

### UPS batteries: VRLA vs lithium and how to choose

[UPS batteries compared: VRLA AGM lead-acid vs LiFePO4 lithium on life, cycles, space and heat, plus how to read 12 V 9 Ah and a buyer's checklist. Read](https://www.aecups.com/en/blog/ups-batteries-vrla-vs-lithium/)

### UPS maintenance: batteries, checks and schedule

UPS maintenance guide: visual checks, alarm logs, battery tests, a monthly to yearly schedule, the maintenance bypass and when to replace UPS batteries. Read

### Battery room ventilation to EN IEC 62485-2 for VRLA

The EN IEC 62485-2 air flow for a VRLA battery, term by term, worked out for every AEC BB4–BB8 cabinet, with the size of the openings. Read

### L6 lithium battery sizing: modules, cabinets, room

How AEC sizes an L6 lithium battery for an IST7 or IST6 UPS: power and energy counts, modules and cabinets for 10 to 30 minutes, floor and c[learances. Read](https://www.aecups.com/en/blog/l6-lithium-battery-sizing/)

Guides

## Three-phase and high power

### Three-phase UPS: configurations, sizing and installation

[A three-phase UPS protects 400 V loads from about 10 kVA up. 3/3 against 3/1, phase balancing, sizing from measured currents, and installation. Read](https://www.aecups.com/en/blog/three-phase-ups/)

### Single- or three-phase UPS: which does your site need?

Single-phase or three-phase UPS? Where the line falls in kVA and amps, what the supply and the loads decide, a 12 kW worked example and a checklist. Read

### Modular UPS: how to grow power module by module

A modular UPS builds power from hot-swappable modules in one cabinet: how it grows with the load, against a conventional UPS, with IST6 examples. Read

### UPS redundancy: N+1 or 2N, and how much a site needs

UPS redundancy explained: what N, N+1, N+X and 2N mean, parallel vs modular UPS, a worked 90 kW example, a comparison table and a checklist. Read

### Isolation transformer UPS: when you need one

Isolation transformer UPS explained: galvanic isolation, the new neutral, when you need one, and transformer based vs transformerless UPS, with an[example. Read](https://www.aecups.com/en/blog/isolation-transformer-ups/)

Guides

## By application

### UPS for data centres: how to choose and plan

[A data centre UPS should be online double conversion, sized on measured IT load plus growth. Worked example, rack and modular options, N+1/2N, batteries. Read](https://www.aecups.com/en/blog/ups-for-data-centres/)

### Industrial UPS: protecting PLCs, motors and processes

How to choose an industrial UPS: online double conversion, inrush and motor loads, harsh sites, 3/1 or 3/3, isolation, bypass and Modbus. With a checklist. Read

### UPS for hospitals and healthcare facilities

A UPS for hospitals keeps medical and IT loads running with no break until the generator starts. Medical locations, redundancy and sizing. Read

### UPS for CCTV and video surveillance systems

A UPS for CCTV keeps cameras, NVR and PoE switches recording through power cuts. How to choose the technology, size it and plan the runtime. Rea[d](https://www.aecups.com/en/blog/ups-for-cctv/)

### UPS for home: protect devices, router and data

A UPS for home keeps router, PC, NAS and alarm running in a power cut. How to size it, which type to pick and what a 3 kW whole-home UPS involves. Read

### UPS for blackouts and storms: what to know

A UPS keeps equipment running through a blackout and filters storm sags and surges. What to check, how long it lasts and which AEC ranges fit. Read

Guides

## Central power supplies (CPSS)

### CPSS to EN 50171: what it asks and how to size one

[A CPSS is a central battery system that powers emergency lighting and safety loads. What EN 50171 covers, how to size a CPSS and a worked example. Read](https://www.aecups.com/en/blog/cpss-en-50171/)

### UPS vs CPSS: which one does a building need?

A UPS keeps equipment running; a CPSS keeps safety systems such as emergency lighting on. How they differ and when a building needs both. Read

## Talk to an AEC engineer

Tell us the load, the supply and the backup time you need: we answer with the model and the batteries that fit.

[Contact us](https://www.aecups.com/en/contacts/#form) [+39 02 9415 8991](tel:+390294158991)
