# AEC and Socomec, datasheet by datasheet.

5 Socomec UPS sold in EMEA, each next to the AEC model that replaces it, figure by figure: rating, online and ECO efficiency, battery, size and weight. The Socomec figures are those of its own datasheets, the AEC figures those of the EMEA 2026 catalogue.

In short

## What the two datasheets say

- Online efficiency, where both datasheets give it (5 pairs): AEC higher in 4, Socomec higher in 1.
- Weight is not compared row by row: each maker weighs something different (with or without the batteries inside). The table gives both figures.
- A pair is a starting point, not an equal: runtime, options and test conditions differ. Compare the full datasheets before you choose.

Datasheets side by side

## Socomec and AEC, model by model.

For each Socomec model, the figures of its own datasheet and, below it, the AEC model that replaces it with the figures of AEC's product data. A figure the datasheet does not give is "—".

| Model | Rating | Online efficiency | ECO | Battery | Size W × D × H | Weight |
| --- | --- | --- | --- | --- | --- | --- |
| **ITYS 1 kVA (ITY3)** ITYS 1–10 kVA | 1 kVA / 1 kW | 93% | — | sealed lead-acid, internal | 145 × 404 × 224 mm | 14.4 kg |
| [**AEC IST3-1**](https://www.aecups.com/en/products/ist3/ist3-1k/) IST3 [Datasheet](https://www.aecups.com/en/products/ist3/ist3-1k/#datasheet) · [UPS finder](https://www.aecups.com/en/tools/ups-finder/) | 1 kVA / 1 kW | 90.8% | 98.3% | internal, 12 V 9 Ah blocks, 24 V; long backup model (-L): external | 145 × 357 × 226 mm | 8.5 kg with batteries; -L 4.6 kg, no battery |
| **ITYS 3 kVA (ITY3)** ITYS 1–10 kVA | 3 kVA / 3 kW | 93% | — | sealed lead-acid, internal | 192 × 428 × 322 mm | 26 kg |
| [**AEC IST3-J 3 kVA**](https://www.aecups.com/en/products/ist3-j/ist3j-3k/) IST3-J [Datasheet](https://www.aecups.com/en/products/ist3-j/ist3j-3k/#datasheet) · [UPS finder](https://www.aecups.com/en/tools/ups-finder/) | 3 kVA / 3 kW | 93.3% | 98.3% | internal, 12 V 9 Ah blocks, 72 V | 438 × 572 × 86 mm | 26 kg with batteries |
| **ITYS 10 kVA (ITY3)** ITYS 1–10 kVA | 10 kVA / 10 kW | 95% | — | sealed lead-acid, internal | 225 × 416 × 589 mm | 61 kg |
| [**AEC IST3-J 10 kVA**](https://www.aecups.com/en/products/ist3-j/ist3j-10k/) IST3-J [Datasheet](https://www.aecups.com/en/products/ist3-j/ist3j-10k/#datasheet) · [UPS finder](https://www.aecups.com/en/tools/ups-finder/) | 10 kVA / 10 kW | 95.5% | 98.3% | external, 192 V default (12–20 × 12 V settable) | 438 × 500 × 86 mm | 12.2 kg, no battery |
| **Masterys BC+ 40 kVA (S4, internal battery)** Masterys BC+ 10–160 kVA | 40 kVA / 40 kW | 95% | 99% | VRLA (normal life), internal | 444 × 800 × 800 mm | — |
| [**AEC IST7-40**](https://www.aecups.com/en/products/ist7-10-40/ist7-40k/) IST7 10–40 [Datasheet](https://www.aecups.com/en/products/ist7-10-40/ist7-40k/#datasheet) · [UPS finder](https://www.aecups.com/en/tools/ups-finder/) | 40 kVA / 40 kW | 96% | 99% | lead-acid, external or inside (S model), ± 144 … ± 240 V DC | 300 × 842 × 1250 mm | 102.5 kg standard, no battery; 249.7 kg S model, with batteries |
| **Masterys BC+ 80 kVA (T6, internal battery)** Masterys BC+ 10–160 kVA | 80 kVA / 72 kW | 95% | 99% | VRLA (normal life), internal | 600 × 855 × 1,930 mm | — |
| [**AEC IST7-80**](https://www.aecups.com/en/products/ist7-60-200/ist7-80k/) IST7 60–200 [Datasheet](https://www.aecups.com/en/products/ist7-60-200/ist7-80k/#datasheet) · [UPS finder](https://www.aecups.com/en/tools/ups-finder/) | 80 kVA / 80 kW | 96.5% | 99% | VRLA or lithium, external cabinets, ±192 V | 400 × 960 × 1193 mm | 163 kg, no battery |

Socomec figures from the documents Socomec publishes on its own site, read between 8 and 13 November 2026; they may have changed since. Efficiency and weight depend on each maker's configuration and test conditions: compare the full datasheets before you choose.

Model by model

## Each Socomec and its AEC

- **ITYS 1 kVA (ITY3)** (1 kVA, ITYS 1–10 kVA) → [AEC IST3-1](https://www.aecups.com/en/products/ist3/ist3-1k/): online efficiency 90.8% against 93%.
- **ITYS 3 kVA (ITY3)** (3 kVA, ITYS 1–10 kVA) → [AEC IST3-J 3 kVA](https://www.aecups.com/en/products/ist3-j/ist3j-3k/): online efficiency 93.3% against 93%.
- **ITYS 10 kVA (ITY3)** (10 kVA, ITYS 1–10 kVA) → [AEC IST3-J 10 kVA](https://www.aecups.com/en/products/ist3-j/ist3j-10k/): online efficiency 95.5% against 95%.
- **Masterys BC+ 40 kVA (S4, internal battery)** (40 kVA, Masterys BC+ 10–160 kVA) → [AEC IST7-40](https://www.aecups.com/en/products/ist7-10-40/ist7-40k/): online efficiency 96% against 95%.
- **Masterys BC+ 80 kVA (T6, internal battery)** (80 kVA, Masterys BC+ 10–160 kVA) → [AEC IST7-80](https://www.aecups.com/en/products/ist7-60-200/ist7-80k/): online efficiency 96.5% against 95%.

AEC against the other makers: [AEC vs APC](https://www.aecups.com/en/comparisons/aec-vs-apc/) · [AEC vs Eaton](https://www.aecups.com/en/comparisons/aec-vs-eaton/) · [AEC vs Vertiv](https://www.aecups.com/en/comparisons/aec-vs-vertiv/) · [AEC vs Riello UPS](https://www.aecups.com/en/comparisons/aec-vs-riello/) · [AEC vs Legrand](https://www.aecups.com/en/comparisons/aec-vs-legrand/)

By size, with every maker: [Single-phase UPS 1–3 kVA](https://www.aecups.com/en/comparisons/single-phase-ups-1-3-kva/) · [Single-phase UPS 6–11 kVA](https://www.aecups.com/en/comparisons/single-phase-ups-6-11-kva/) · [Three-phase UPS 10–40 kVA](https://www.aecups.com/en/comparisons/three-phase-ups-10-40-kva/) · [Three-phase UPS 50–250 kVA](https://www.aecups.com/en/comparisons/three-phase-ups-50-250-kva/)

[The AEC model for any other Socomec UPS](https://www.aecups.com/en/tools/ups-replacement/#find)

Questions

## AEC vs Socomec

#### Which AEC UPS replaces the Socomec ITYS 1 kVA (ITY3)?

The AEC IST3-1 (IST3 range, 1 kVA / 1 kW), the model the UPS replacement tool gives for the ITYS 1 kVA (ITY3) (1 kVA, 1/1). Both sets of figures are in this page's table.

#### Which AEC UPS replaces the Socomec ITYS 3 kVA (ITY3)?

The AEC IST3-J 3 kVA (IST3-J range, 3 kVA / 3 kW), the model the UPS replacement tool gives for the ITYS 3 kVA (ITY3) (3 kVA, 1/1). Both sets of figures are in this page's table.

#### Where do the Socomec figures come from?

From the documents Socomec publishes on its own site (datasheets, brochures, specifications), read between 8 and 13 November 2026; each document is named at the foot of the page. A figure the datasheet does not give is "—", never estimated.

Sources

## The Socomec documents read

- ITYS 1 kVA (ITY3): maker catalogue pages (Socomec ITYS 1-10 kVA, DCG0066102, 2022, socomec.com), read 13 November 2026.
- ITYS 3 kVA (ITY3): maker catalogue pages (Socomec ITYS 1-10 kVA, DCG0066102, 2022, socomec.com), read 13 November 2026.
- ITYS 10 kVA (ITY3): maker catalogue pages (Socomec ITYS 1-10 kVA, DCG0066102, 2022, socomec.com), read 13 November 2026.
- Masterys BC+ 40 kVA (S4, internal battery): maker product page, technical data (Socomec MASTERYS BC+ 10-160 kVA, socomec.com), read 13 November 2026.
- Masterys BC+ 80 kVA (T6, internal battery): maker product page, technical data (Socomec MASTERYS BC+ 10-160 kVA, socomec.com), read 13 November 2026.

Other makers' names and model numbers are trademarks of their owners, used only to identify the models; AEC is not affiliated with them.