Questions and answers

# Questions about the tools, the comparisons and AEC

82 questions that no single range owns: the tools, the comparisons with other makers, the product families, the warranty and the company. Each answer is the one printed on its page, linked below it.

[All questions](https://www.aecups.com/en/faq/)

## Choosing, sizing and ordering 29 questions

#### Is there an AEC office in the Middle East?

Yes: AEC Power LLC in Dubai is the AEC Group company for the Middle East, working 08–18 local time (UTC+4). Requests go through the EMEA office in Lainate, which answers within one working day and involves the Dubai team.

Answered on [Middle East data centres](https://www.aecups.com/en/applications/middle-east-data-centres/)

#### Which AEC UPS replaces the APC SRT1000XLI?

The AEC IST3-1 (IST3 range, 1 kVA / 1 kW), the model the UPS replacement tool gives for the SRT1000XLI (1 kVA, 1/1). Both sets of figures are in this page's table.

Answered on [AEC vs APC](https://www.aecups.com/en/comparisons/aec-vs-apc/)

#### Which AEC UPS replaces the APC SRT6KXLI?

The AEC IST3-J 6 kVA (IST3-J range, 6 kVA / 6 kW), the model the UPS replacement tool gives for the SRT6KXLI (6 kVA, 1/1). Both sets of figures are in this page's table.

Answered on [AEC vs APC](https://www.aecups.com/en/comparisons/aec-vs-apc/)

#### Which AEC UPS replaces the Eaton 9SX1000I?

The AEC IST3-1 (IST3 range, 1 kVA / 1 kW), the model the UPS replacement tool gives for the 9SX1000I (1 kVA, 1/1). Both sets of figures are in this page's table.

Answered on [AEC vs Eaton](https://www.aecups.com/en/comparisons/aec-vs-eaton/)

#### Which AEC UPS replaces the Eaton 93PS-20(20)?

The AEC IST7-20 (IST7 10–40 range, 20 kVA / 20 kW), the model the UPS replacement tool gives for the 93PS-20(20) (20 kVA, 3/3). Both sets of figures are in this page's table.

Answered on [AEC vs Eaton](https://www.aecups.com/en/comparisons/aec-vs-eaton/)

#### Which AEC UPS replaces the Legrand Keor T EVO 10 kVA (3 110 21)?

The AEC IST7-10 (IST7 10–40 range, 10 kVA / 10 kW), the model the UPS replacement tool gives for the Keor T EVO 10 kVA (3 110 21) (10 kVA, 3/3). Both sets of figures are in this page's table.

Answered on [AEC vs Legrand](https://www.aecups.com/en/comparisons/aec-vs-legrand/)

#### Which AEC UPS replaces the Legrand Keor T EVO 60 kVA (3 110 41)?

The AEC IST7-60 (IST7 60–200 range, 60 kVA / 60 kW), the model the UPS replacement tool gives for the Keor T EVO 60 kVA (3 110 41) (60 kVA, 3/3). Both sets of figures are in this page's table.

Answered on [AEC vs Legrand](https://www.aecups.com/en/comparisons/aec-vs-legrand/)

#### Which AEC UPS replaces the Riello UPS SP2 1000 A3?

The AEC IST3-1 (IST3 range, 1 kVA / 1 kW), the model the UPS replacement tool gives for the SP2 1000 A3 (1 kVA, 1/1). Both sets of figures are in this page's table.

Answered on [AEC vs Riello UPS](https://www.aecups.com/en/comparisons/aec-vs-riello/)

#### Which AEC UPS replaces the Riello UPS S3T 10 CPT?

The AEC IST7-10 (IST7 10–40 range, 10 kVA / 10 kW), the model the UPS replacement tool gives for the S3T 10 CPT (10 kVA, 3/3). Both sets of figures are in this page's table.

Answered on [AEC vs Riello UPS](https://www.aecups.com/en/comparisons/aec-vs-riello/)

#### Which AEC UPS replaces the Socomec ITYS 1 kVA (ITY3)?

The AEC IST3-1 (IST3 range, 1 kVA / 1 kW), the model the UPS replacement tool gives for the ITYS 1 kVA (ITY3) (1 kVA, 1/1). Both sets of figures are in this page's table.

Answered on [AEC vs Socomec](https://www.aecups.com/en/comparisons/aec-vs-socomec/)

#### Which AEC UPS replaces the Socomec ITYS 3 kVA (ITY3)?

The AEC IST3-J 3 kVA (IST3-J range, 3 kVA / 3 kW), the model the UPS replacement tool gives for the ITYS 3 kVA (ITY3) (3 kVA, 1/1). Both sets of figures are in this page's table.

Answered on [AEC vs Socomec](https://www.aecups.com/en/comparisons/aec-vs-socomec/)

#### Which AEC UPS replaces the Vertiv GXT5-1000IRT2UXL?

The AEC IST3-J 1 kVA (IST3-J range, 1 kVA / 1 kW), the model the UPS replacement tool gives for the GXT5-1000IRT2UXL (1 kVA, 1/1). Both sets of figures are in this page's table.

Answered on [AEC vs Vertiv](https://www.aecups.com/en/comparisons/aec-vs-vertiv/)

#### Which AEC UPS replaces the Vertiv Liebert EXL S1 100 kVA?

The AEC IST7-100 (IST7 60–200 range, 100 kVA / 100 kW), the model the UPS replacement tool gives for the Liebert EXL S1 100 kVA (100 kVA, 3/3). Both sets of figures are in this page's table.

Answered on [AEC vs Vertiv](https://www.aecups.com/en/comparisons/aec-vs-vertiv/)

#### Which UPS does this page compare?

11 online models of APC, Eaton, Vertiv, Riello UPS, Socomec in the Single-phase UPS 1–3 kVA class, each with the AEC model that replaces it (ranges IST3, IST3-J).

Answered on [Single-phase UPS 1–3 kVA](https://www.aecups.com/en/comparisons/single-phase-ups-1-3-kva/)

#### What is the difference between a CPSS and a UPS?

A UPS protects critical loads such as servers and processes; a CPSS is dedicated to safety services and must not carry general loads. AEC's CPSS are built on the online IST3 and IST7 platforms, with overload, recharge and indications set for [EN 50171](https://mycatalogo.ceinorme.it/cei/item/0000018393?sso=y). The guide on UPS and CPSS goes into the detail.

Answered on [Central power supply (CPSS)](https://www.aecups.com/en/products/cpss-en-50171/)

#### What are maintained and non-maintained emergency lights?

Maintained luminaires are lit with the mains present as well (maintained loads); non-maintained ones light only when the mains fails. An AEC CPSS works in the mode without interruption and feeds both: the designer gives the split between maintained and non-maintained loads.

Answered on [Central power supply (CPSS)](https://www.aecups.com/en/products/cpss-en-50171/)

#### Which IST6 modular range fits my power?

The IST6-120 uses 30 kVA modules from 30 to 120 kVA in one cabinet; the IST6 200–500 uses 50 kVA modules in cabinets of 200, 300, 400 and 500 kVA; the IST6 400–1200 uses 100 kVA modules from 400 kVA to 1.2 MVA per cabinet.

Answered on [Modular UPS](https://www.aecups.com/en/products/modular-ups/)

#### How do redundancy and parallel operation differ between the modular ranges?

The IST6-120 has a fifth slot for an N+1 module, and several cabinets work in parallel with the parallel kit. The IST6 200–500 and 400–1200 run up to eight UPS in parallel with N+X redundancy, up to 9.6 MW on the larger range, and add three-bus layouts to BSC dual bus.

Answered on [Modular UPS](https://www.aecups.com/en/products/modular-ups/)

#### What is the difference between the IST3, IST3-J and IST8?

All three are single-phase online double-conversion UPS with 0 ms transfer. The IST3 is a tower from 1 to 10 kVA, standard or long backup; the IST3-J is a 2U 19-inch rack unit from 1 to 10 kVA (tower too on 1–3 kVA); the IST8 is a 2U rack / tower unit from 1 to 3 kVA with a built-in lithium-ion battery.

Answered on [Single-phase UPS](https://www.aecups.com/en/products/single-phase-ups/)

#### How much real power in watts does each range deliver?

The IST8 has output power factor 1, so its 3 kVA delivers 3000 W. The IST3 and IST3-J have output power factor 1 too: the 3 kVA delivers 3000 W and the 10 kVA 10,000 W.

Answered on [Single-phase UPS](https://www.aecups.com/en/products/single-phase-ups/)

#### Which three-phase AEC UPS should I choose?

The IST9 (10–40 kVA) is a 3U unit for 19-inch racks or towers, the IST7 10–40 kVA a floor-standing UPS with internal or external batteries. The IST7 60–200 kVA covers larger loads; the IST7-T (100–200 kVA) adds a built-in output isolation transformer; the All-in-One (20 kVA) puts UPS and lithium modules in one cabinet.

Answered on [Three-phase UPS](https://www.aecups.com/en/products/three-phase-ups/)

#### Which three-phase ranges can supply single-phase loads?

The IST9 and the IST7 10–40 kVA work in 3/3 or 3/1 mode, and their 10–20 kVA models also in 1/1. The All-in-One 20 kVA works 3/3 or 3/1 only.

Answered on [Three-phase UPS](https://www.aecups.com/en/products/three-phase-ups/)

#### Which ranges support parallel and redundant systems?

The IST7 10–40 kVA runs up to 4 units in parallel and the IST7 60–200 kVA up to 8 (1.6 MW), with BSC dual-bus synchronisation. The IST9 supports N+1 with its parallel card, and the IST7-T supports parallel, series hot standby and dual-bus systems.

Answered on [Three-phase UPS](https://www.aecups.com/en/products/three-phase-ups/)

#### Which AEC UPS for a 10 kVA load on a single-phase supply?

IST3-10 (tower, internal batteries, 10 kW), IST3-J 10 kVA (2U rack, external batteries, 10 kW), or IST9 10 kVA and IST7-10 set to 1/1 (10 kW). Keep the load within about 80% of the rating: a steady 10 kW load wants the next size up or two units.

Answered on [Which AEC UPS range for my load](https://www.aecups.com/en/products/which-ups-range/)

#### When is a modular UPS worth it?

When the load will grow, when redundancy (N+1) is required without a second UPS, or when service must not stop the load: IST6 modules are added and replaced online. For a fixed load, a monolithic IST7 does the job with one unit.

Answered on [Which AEC UPS range for my load](https://www.aecups.com/en/products/which-ups-range/)

#### How many models does the AEC UPS replacement cover?

693 models of 7 makers, each matched to the AEC model on the same supply with at least the same rating. Another 8 models have no AEC range at their rating or configuration: AEC's engineers answer those.

Answered on [UPS replacement](https://www.aecups.com/en/tools/ups-replacement/)

#### What replaces the APC SMT1000I?

The AEC IST3-1-2X9 at 1 kVA, of the IST3 range, on the same supply (230 V single-phase); it is an online double-conversion UPS, as AEC offers no line-interactive UPS.

Answered on [UPS replacement](https://www.aecups.com/en/tools/ups-replacement/)

#### What replaces the APC GVSUPS20KHS?

The AEC IST7-20 at 20 kVA, of the IST7 10–40 range, on the same supply (400 V three-phase).

Answered on [UPS replacement](https://www.aecups.com/en/tools/ups-replacement/)

#### Is the AEC model a drop-in replacement?

Not always: it takes the same load on the same supply, but it is a starting point, not an equal: backup time, size, outlets or terminals and options differ. Compare both datasheets and the space before you order; send the label and the load and an AEC engineer confirms the match.

Answered on [UPS replacement](https://www.aecups.com/en/tools/ups-replacement/)

## Backup time and batteries 9 questions

#### Which OZ Power battery goes in which AEC cabinet?

The 9 Ah block goes in the UPS and in BB1–BB5 and BBJ cabinets, 24 and 40 Ah in the BB5, 60 Ah in BB6 and BB7, and 80 and 100 Ah in BB7 and BB8. The 200 Ah block is for large systems, on request.

Answered on [Batteries and cabinets](https://www.aecups.com/en/products/batteries-and-cabinets/)

#### Who sizes the battery for my project?

AEC sizes the battery for every project: send the loads and the backup time required to sales@aecups.com or +39 02 9415 8991. AEC engineers choose the module or battery type, the quantity, the cabinets and the reserve.

Answered on [Batteries and cabinets](https://www.aecups.com/en/products/batteries-and-cabinets/)

#### How long must a CPSS run on battery?

The fire-safety design and the national rules set it, not the CPSS: EN 1838 asks at least 1 h for escape-route lighting, and 3 h is common where the building stays occupied after the mains fails. AEC sizes the battery for that time at end of life.

Answered on [Central power supply (CPSS)](https://www.aecups.com/en/products/cpss-en-50171/)

#### How fast does the battery recharge?

EN 50171 (6.3.3) asks a recharge to at least 80% of the rated operating time in 12 hours. AEC's CPSS recharge from low battery in under 12 hours with the battery sized to the charger: up to 4–8 A on CPSS3, 10–20 A on CPSS7 10–40 and 30–60 A on CPSS7 60–200.

Answered on [Central power supply (CPSS)](https://www.aecups.com/en/products/cpss-en-50171/)

#### Which single-phase UPS gives the longest backup with internal batteries?

At 1–3 kVA, the IST8 gives 11 minutes with its lithium battery, while the IST3 and IST3-J standard models give 3 minutes at full load. The IST3 6 and 10 kVA give 5 / 20 and 1 / 15 minutes at full / half load; the IST3-J 6–10 kVA and all long backup models depend on external batteries.

Answered on [Single-phase UPS](https://www.aecups.com/en/products/single-phase-ups/)

#### What battery options do the three-phase ranges offer?

The IST9 uses BBJ2 rack cabinets or the approved lithium system. The IST7 10–40 kVA has internal batteries (S models) or BB4–BB8 cabinets; the IST7 60–200 kVA uses BB5–BB8 cabinets or lithium with the BMS card; the IST7-T uses an external battery, lithium supported. The All-in-One has lithium modules built in, up to 200 minutes at 6 kW.

Answered on [Three-phase UPS](https://www.aecups.com/en/products/three-phase-ups/)

#### How is UPS backup time calculated?

You need the load in kW (not kVA), the battery (type, capacity in Ah, blocks per string and strings) and the end-of-discharge voltage. For VRLA batteries AEC's calculator reads the power per block in the battery maker's constant-power table, at 1.70 V/cell and 96% efficiency, as AEC's portal does.

Answered on [Backup time](https://www.aecups.com/en/tools/backup-time/)

#### Why is the backup time more than double at half load?

Because a battery gives more in a slow discharge. In the example the AEC IST7-20 with 36 × 12 V 9 Ah runs 2 minutes at full load and 6 at half load.

Answered on [Backup time](https://www.aecups.com/en/tools/backup-time/)

#### Do the minutes hold for the whole battery life?

No: the tables give minutes with new batteries at 25 °C. Capacity falls with age and with higher temperatures, so a system is sized with a margin. AEC's engineers check every sizing.

Answered on [Backup time](https://www.aecups.com/en/tools/backup-time/)

## Lithium batteries 8 questions

#### What is AEC UPS?

AEC is the UPS brand of Allis Electric Co., Ltd., founded in Taipei in 1968 and listed on the Taiwan Stock Exchange since 1994. In Europe, the Middle East and Africa, AEC International Srl, in Lainate (Milan) since 1998, sells and services online UPS from 1 kVA to 1.2 MVA, with lithium or VRLA batteries.

Answered on [About AEC](https://www.aecups.com/en/about/)

#### Is AEC UPS reliable?

Yes, on what can be checked: Allis Electric's quality system is certified to ISO 9001:2015 by SGS (certificate TW16/00399.00, valid to 16 June 2027, UPS in scope). Every AEC UPS has a 3-year warranty, the lithium ranges (IST8, All-in-One) and the L6 cabinets 5 years; service answers 24/7 and spare parts are kept in stock in more than 21 countries; the group has worked in power equipment since 1968 and has been listed in Taipei since 1994.

Answered on [About AEC](https://www.aecups.com/en/about/)

#### Lithium or VRLA: which battery should I choose for my UPS?

The L6 uses lithium iron phosphate modules rated for 5,000 cycles at 50% depth of discharge, hot-swappable and monitored by a three-layer BMS, for AEC IST7 and IST6 UPS from 6 to 1200 kVA. OZ Power VRLA AGM batteries are sealed and maintenance-free, with a design life of 6–8 years (9–24 Ah) or 12 years (40–200 Ah), and go into AEC battery cabinets.

Answered on [Batteries and cabinets](https://www.aecups.com/en/products/batteries-and-cabinets/)

#### How do lithium and VRLA cabinets compare in size?

An L6 cabinet measures 600 × 850 × 2000 mm and stores up to 41, 58 or 69 kWh depending on the module. VRLA cabinets range from the BB5 at 460 × 800 × 1400 mm to the BB8 at 1400 × 800 × 1900 mm, which holds up to 64 batteries of 80 or 100 Ah in two strings.

Answered on [Batteries and cabinets](https://www.aecups.com/en/products/batteries-and-cabinets/)

#### How does maintenance differ between lithium and VRLA?

VRLA cabinets need monthly visual checks, battery voltages every 6 months, terminal torque every 12 months and a capacity test or replacement every 3–5 years. L6 maintenance is done online, module by module: a faulty module leaves the system on its own and is replaced in about 5 minutes.

Answered on [Batteries and cabinets](https://www.aecups.com/en/products/batteries-and-cabinets/)

#### Do the modular ranges work with lithium batteries?

Yes, all three accept lead-acid or lithium batteries with the optional BMS expansion card, and parallel systems can share a common battery. Lead-acid strings are ±14 to ±23 × 12 V blocks on the IST6-120, and 30 to 50 blocks on the larger ranges (±240 V and 480 V nominal with 40 blocks).

Answered on [Modular UPS](https://www.aecups.com/en/products/modular-ups/)

#### Lead-acid or lithium: what battery life can I expect?

The IST3 and IST3-J standard models have internal 12 V 9 Ah batteries, with a typical life of 3–5 years on the IST3 depending on temperature and use. The IST8 lithium-ion battery offers up to 8 years of service life and up to 1000 charge / discharge cycles.

Answered on [Single-phase UPS](https://www.aecups.com/en/products/single-phase-ups/)

#### Lithium or VRLA: how does the tool work them out?

For lithium (All-in-One modules and L6 cabinets) the tool reads the EMEA 2026 catalogue's tables; for OZ Power VRLA batteries it uses AEC's calculator. One L6 cabinet with 100 Ah modules stores 69 kWh.

Answered on [Backup time](https://www.aecups.com/en/tools/backup-time/)

## Installation, size and connections 10 questions

#### Which ambient temperature do AEC UPS run at?

Every AEC UPS range is rated for operation up to 40 °C, from −5 or 0 °C depending on the range, as its user manual or the EMEA 2026 catalogue gives it; the table lists each range with its source. None publishes operation above 40 °C: for a hotter room, ask AEC before you size.

Answered on [Middle East data centres](https://www.aecups.com/en/applications/middle-east-data-centres/)

#### What does heat do to the batteries?

It shortens their life: VRLA battery life halves for about every 8 °C above 25 °C (OZ Power data: about 43% of design life at 35 °C). AEC's battery cabinets are rated 0 to 40 °C, best at 20–25 °C (BB5–BB8) or 25 °C (BB4), and the L6 lithium cabinets 0 to 40 °C, so the battery room is where cooling pays first.

Answered on [Middle East data centres](https://www.aecups.com/en/applications/middle-east-data-centres/)

#### How do I plan for dust?

Put the UPS in a closed, cooled electrical room with filtered air, keep the clearances its manual gives for the air paths, and add filter checks to the maintenance plan. The ranges' datasheets give no dust rating: ask AEC about a filtered enclosure for the site.

Answered on [Middle East data centres](https://www.aecups.com/en/applications/middle-east-data-centres/)

#### Can these drawings be used for a project?

No: they are examples, not real sites and not for construction. AEC equipment is drawn at the EMEA 2026 catalogue's sizes and weights; everything else is by others, drawn to scale. The project's designer designs; AEC's engineers size the AEC part.

Answered on [Example designs](https://www.aecups.com/en/example-designs/)

#### Can I have the CAD files?

Yes, with your project: send us the plan and the single-line diagram, and an AEC engineer returns the AEC equipment, its batteries and its footprint in DWG.

Answered on [Example designs](https://www.aecups.com/en/example-designs/)

#### How much floor space do the modular cabinets take?

All are 2000 mm high, and the IST6-120 cabinet is 600 × 860 mm. The IST6 200–500 cabinets are 607 × 860 mm (200–300 kVA) or 1203 × 864 mm (400–500 kVA); the IST6 400–1200 cabinets are 801 × 1000 mm (400–800 kVA) or 1201 × 1000 mm (1000–1200 kVA).

Answered on [Modular UPS](https://www.aecups.com/en/products/modular-ups/)

#### Which single-phase UPS fits a 19-inch rack, and which can run in parallel?

The IST3-J and IST8 are 2U, 438 mm wide units for 19-inch racks, while the IST3 is a tower. Only the IST3-J 10 kVA /B version can be used in parallel.

Answered on [Single-phase UPS](https://www.aecups.com/en/products/single-phase-ups/)

#### Which AEC UPS fit a 19-inch rack?

IST3-J (1–10 kVA, 2U), IST8 (1–3 kVA lithium, 2U) and IST9 (10–40 kVA, 3U), with BBJ and BBJ2 rack battery cabinets.

Answered on [Which AEC UPS range for my load](https://www.aecups.com/en/products/which-ups-range/)

#### How much space does a UPS need in front?

What the range's manual asks for, and at least the operating gangway of [HD 60364-7-729](https://webstore.iec.ch/en/publication/1907): 700 mm from the cabinet to the wall, 600 mm from the breaker handles, 500 mm past an open door or a withdrawn module. Room fit draws and checks both.

Answered on [Room fit](https://www.aecups.com/en/tools/room-fit/)

#### Does the battery room need ventilation?

Yes, with lead-acid batteries: [EN IEC 62485-2](https://webstore.iec.ch/en/publication/7091) gives the air flow from the number of cells and the Ah, and the opening area for natural ventilation. Room fit works it out for the cabinets chosen.

Answered on [Room fit](https://www.aecups.com/en/tools/room-fit/)

## Communication and monitoring 6 questions

#### Does the USB card shut the computer down on a long outage?

Yes. With the power management software the computer receives the power-failure alert, and it shuts down automatically when the outage lasts, before the battery runs out.

Answered on [USB card](https://www.aecups.com/en/products/usb-card/)

#### USB card or SNMP card?

The USB card links the UPS to one computer through its USB port. The SNMP card puts the UPS on the network with its own web page, so it can be monitored and operated remotely from anywhere.

Answered on [USB card](https://www.aecups.com/en/products/usb-card/)

#### Which card monitors a UPS over the network?

The SNMP card: it puts the UPS on the LAN with its own web page, for monitoring, alarms and remote shutdown. The table on this page shows which ranges take it, as standard or as an option.

Answered on [UPS accessories](https://www.aecups.com/en/products/ups-accessories/)

#### What is a dry-contact card for?

It gives potential-free relay contacts, normally open or normally closed, that signal UPS states such as mains failure or low battery to an alarm panel or a building management system, and it allows a manual or automatic remote shutdown.

Answered on [UPS accessories](https://www.aecups.com/en/products/ups-accessories/)

#### What is the display simulator for?

To find a screen or a setting before you touch the UPS: the states (normal, on battery, bypass), the readings, the alarms and the menus, as on the real panel.

Answered on [Display simulators](https://www.aecups.com/en/tools/simulators/)

#### Do I need an account to use it?

No: every display simulator is open to anyone, here and on each range's page. For a procedure on your own installation, ask AEC.

Answered on [Display simulators](https://www.aecups.com/en/tools/simulators/)

## Efficiency and operation 5 questions

#### Do AEC UPS run on a generator?

Yes: online double conversion rebuilds the output from DC, so the load sees a stable voltage and frequency while the generator starts and settles. A low input THDi makes the generator easier to size: ≤ 3% on the IST7 60–200, with input power factor ≥ 0.99, and ≤ 1.5% on the IST6 200–500.

Answered on [Middle East data centres](https://www.aecups.com/en/applications/middle-east-data-centres/)

#### How do the modular ranges compare on efficiency?

The IST6-120 reaches 97% in double conversion and up to 99% in ECO; the IST6 200–500 up to 98.1%; the IST6 400–1200 up to 97.2% with General modules and 98.1% with PLUS modules, with 99.2% in ECO. All three offer redundancy sleep for spare modules at light load.

Answered on [Modular UPS](https://www.aecups.com/en/products/modular-ups/)

#### How do the three-phase ranges compare on efficiency and power factor?

The IST9 and IST7 10–40 kVA reach 96% in double conversion and 99% in ECO mode, the IST7 60–200 kVA 96.5% and 99%, all with output power factor 1 (kVA = kW). The IST7-T is rated lower in kW than in kVA, for example 200 kVA / 180 kW.

Answered on [Three-phase UPS](https://www.aecups.com/en/products/three-phase-ups/)

#### Which AEC UPS has an isolation transformer?

The IST7-T, 100 to 200 kVA, with the output isolation transformer built in on every model. For IST6 200–1200 kVA the catalogue lists an output isolation transformer of the same capacity as an option.

Answered on [Which AEC UPS range for my load](https://www.aecups.com/en/products/which-ups-range/)

#### Does AEC offer line-interactive UPS?

No: every AEC UPS for EMEA is online double conversion. The 168 line-interactive or standby models in the list are matched to the nearest AEC online UPS, which always feeds the load from its inverter.

Answered on [UPS replacement](https://www.aecups.com/en/tools/ups-replacement/)

## Standards and certification 2 questions

#### What is a central power supply system (CPSS)?

A central supply for safety services: from its battery it feeds emergency escape lighting and safety signs, the circuits of fire-extinguishing installations, emergency paging and smoke extraction when the normal supply fails. EN 50171 sets its requirements.

Answered on [Central power supply (CPSS)](https://www.aecups.com/en/products/cpss-en-50171/)

#### Are AEC CPSS certified to EN 50171?

No certificate is published on this site. AEC's CPSS are designed to meet the requirements of EN 50171, and the user manual's own chapter lists clause by clause what the standard asks, what the CPSS provides and what falls to the designer and the installer. The designer verifies the safety installation with the commissioning tests.

Answered on [Central power supply (CPSS)](https://www.aecups.com/en/products/cpss-en-50171/)

## Warranty, service and maintenance 4 questions

#### When is an external maintenance bypass needed?

When the UPS must be serviced, repaired or replaced without switching off the load: the bypass takes the UPS terminals out of voltage while the load stays supplied. The MBYP-3K serves UPS up to 3 kVA, the MBYP-6K up to 10 kVA.

Answered on [UPS accessories](https://www.aecups.com/en/products/ups-accessories/)

#### How long is the warranty on an AEC UPS in Europe?

3 years on the UPS electronics; 5 years on the lithium batteries of the IST8 and All-in-One and on the L6 cabinets. Ex works Lainate (Milan), subject to verification by our technical team.

Answered on [Warranty](https://www.aecups.com/en/warranty/)

#### Where is the warranty given?

At AEC's premises in Lainate (Milan), ex works (EXW, Incoterms® 2020). On-site service can be arranged with a maintenance contract.

Answered on [Warranty](https://www.aecups.com/en/warranty/)

#### Does the AEC warranty replace the legal guarantee?

No. Consumers keep the 2-year legal guarantee of conformity; the AEC warranty adds to it.

Answered on [Warranty](https://www.aecups.com/en/warranty/)

## About the product and AEC 9 questions

#### How do I become an AEC partner or distributor?

Write to sales@aecups.com: the AEC Partnership programme is open to every customer, on three levels (Gold, Platinum and Diamond), with engineering support and distributor pricing.

Answered on [About AEC](https://www.aecups.com/en/about/)

#### Where do the APC figures come from?

From the documents APC publishes on its own site (datasheets, brochures, specifications), read between 8 and 13 November 2026; each document is named at the foot of the page. A figure the datasheet does not give is "—", never estimated.

Answered on [AEC vs APC](https://www.aecups.com/en/comparisons/aec-vs-apc/)

#### Where do the Eaton figures come from?

From the documents Eaton publishes on its own site (datasheets, brochures, specifications), read between 8 and 13 November 2026; each document is named at the foot of the page. A figure the datasheet does not give is "—", never estimated.

Answered on [AEC vs Eaton](https://www.aecups.com/en/comparisons/aec-vs-eaton/)

#### Where do the Legrand figures come from?

From the documents Legrand publishes on its own site (datasheets, brochures, specifications), read between 8 and 13 November 2026; each document is named at the foot of the page. A figure the datasheet does not give is "—", never estimated.

Answered on [AEC vs Legrand](https://www.aecups.com/en/comparisons/aec-vs-legrand/)

#### Where do the Riello UPS figures come from?

From the documents Riello UPS publishes on its own site (datasheets, brochures, specifications), read between 8 and 13 November 2026; each document is named at the foot of the page. A figure the datasheet does not give is "—", never estimated.

Answered on [AEC vs Riello UPS](https://www.aecups.com/en/comparisons/aec-vs-riello/)

#### Where do the Socomec figures come from?

From the documents Socomec publishes on its own site (datasheets, brochures, specifications), read between 8 and 13 November 2026; each document is named at the foot of the page. A figure the datasheet does not give is "—", never estimated.

Answered on [AEC vs Socomec](https://www.aecups.com/en/comparisons/aec-vs-socomec/)

#### Where do the Vertiv figures come from?

From the documents Vertiv publishes on its own site (datasheets, brochures, specifications), read between 8 and 13 November 2026; each document is named at the foot of the page. A figure the datasheet does not give is "—", never estimated.

Answered on [AEC vs Vertiv](https://www.aecups.com/en/comparisons/aec-vs-vertiv/)

#### Where do the figures come from?

The other makers' from the documents on their own sites, read between 8 and 13 November 2026 (each document is named at the foot of the page); AEC's from the EMEA 2026 catalogue. A figure a datasheet does not give is "—", never estimated.

Answered on [Single-phase UPS 1–3 kVA](https://www.aecups.com/en/comparisons/single-phase-ups-1-3-kva/)

#### Can I get the PDF report or the CAD drawing?

Yes, with the project: ask AEC and an engineer sends the PDF report and the drawing for CAD.

Answered on [Room fit](https://www.aecups.com/en/tools/room-fit/)

## By range

## Still a question?

Tell us the load, the supply and the backup time you need: AEC answers with the model and the batteries.