title: "Lithium UPS cabinet 20 kVA, 3/3 and 3/1 · All-in-One | AEC"
url: https://www.aecups.com/en/products/all-in-one/all-in-one-20k/
description: "The All-in-One 20 kVA is one cabinet with an IST9 20 kVA UPS, distribution and maintenance bypass switches, and 2–8 × 50 Ah or 4 × 100 Ah lithium modules."
language: en
---

All-in-One · Three-phase UPS

# All-in-One 20 kVA Lithium UPS cabinet 20 kVA, 3/3 and 3/1

Lithium 20 kVA UPS + lithium in one cabinet

The All-in-One 20 kVA is one cabinet with an IST9 20 kVA UPS, distribution and maintenance bypass switches, and 2–8 × 50 Ah or 4 × 100 Ah lithium modules. For data rooms, offices, finance, transport and education sites with a three-phase supply and loads up to 20 kW that want lithium backup on a 0.6 m² footprint.

**20 kVA / 20 kW** Rating

**600 × 1000 × 1110 mm** W × D × H

**2–8 × 50 Ah or 4 × 100 Ah LFP** Battery

Technical data [Catalogue (PDF)](https://www.aecups.com/docs/AEC_UPS_Catalogue_EMEA_2026.pdf#page=42) [Contact us](https://www.aecups.com/en/contacts/?interest=Three-phase%20UPS&msg=About%20the%20AEC%20All-in-One%2020%20kVA%20(All-in-One)%3A%20%0AQuantity%3A%20#form)

[**Try 3D** X-ray view](https://www.aecups.com/assets/models3d/aio-20/v69/)

Quick answers

## All-in-One 20 kVA: quick answers

**What it is**: The All-in-One 20 kVA is one cabinet with an IST9 20 kVA UPS, distribution and maintenance bypass switches, and 2–8 × 50 Ah or 4 × 100 Ah lithium modules.

**Who it is for**: For data rooms, offices, finance, transport and education sites with a three-phase supply and loads up to 20 kW that want lithium backup on a 0.6 m² footprint.

**Supply and configuration**: 3/3 · 3/1 · 220 / 230 / 240 V L-N · 380 / 400 / 415 V L-L (IST9, 3/3 · 3/1)

**Battery and backup**: 2–8 × 50 Ah or 4 × 100 Ah LFP · 15–60 min at 20 kW (50 Ah) · 60 min at 20 kW, 200 min at 6 kW (4 × 100 Ah)

**Size and weight**: 600 × 1000 × 1110 mm · 232 kg with 2 × 50 Ah, up to 460 kg with 8 × 50 Ah

**Ordering code**: AIO-20K-2X50 … AIO-20K-8X50 (2 to 8 × 50 Ah) · AIO-20K-4X100 (4 × 100 Ah)

All-in-One

## What sets apart the All-in-One 20 kVA

There is one All-in-One: the 20 kVA, with the IST9 20 kVA inside, working 3/3 or 3/1. Mains, bypass and output are the only wires to run on site; the modules are connected to the UPS at the factory, and AEC sets their number and charge current (up to 10 A) at commissioning. In 3/3 the IST9 draws 35 A per phase on a 63 A 3P input breaker; in 3/1 the bypass and output carry 91 A on 125 A 1P breakers.

Each 50 Ah module gives up to 10 kW through its own DC/DC converter, so two of them already carry the full 20 kW: 15 minutes at 20 kW, 60 minutes with eight. The 100 Ah version always has four modules of 5 kW each: 23.0 kWh, 60 minutes at 20 kW and 200 minutes at 6 kW, in the same footprint and 108 kg lighter than eight 50 Ah modules.

Size and floor

## How big it is

600 × 1000 × 1110 mm · 232 kg with 2 × 50 Ah, up to 460 kg with 8 × 50 Ah.

**0.6 m²** footprint

**387–767 kg/m²** floor load

**1.11 m** height

Floor load = weight ÷ footprint: 387 kg/m² at the lowest weight given (232 kg), 767 kg/m² at the highest (460 kg).

Backup time

## How long does the AEC All-in-One 20 kVA run at your load?

AEC's backup times for every ordering code: the minutes AEC publishes from 50 to 100% load, AEC's calculator below 50% and for a string you compose. Pick a battery option: the curve redraws, and every point says where it comes from.

Load50% · 10 kW

Loading AEC's data…

Source: AEC EMEA product data: ordering codes, cabinets, blocks and strings, and the times AEC publishes from 50 to 100% load. Below 50%, AEC's calculator (W per cell = load ÷ 96% ÷ cells, read on a straight line between the columns of the battery maker's constant-power table at 1.70 V/cell), scaled to meet the published 50% figure. Lithium: published times only. All-in-One lithium modules: the catalogue's reference values, to be confirmed by actual measurement. New batteries, 25 °C. AEC checks every sizing.

#### Table: the All-in-One 20 kVA minutes at 20, 50, 80 and 100% load

**All-in-One 20 kVA: backup time in minutes at the load shown (100% = 20 kW)**

| Batteries | Code | 20% | 50% | 80% | 100% |
| --- | --- | --- | --- | --- | --- |
| 2 × lithium modules 50 Ah | `AIO-20K-2X50` | — | 30 | 19 | 15 |
| 8 × lithium modules 50 Ah | `AIO-20K-8X50` | — | 120 | 75 | 60 |
| 4 × lithium modules 100 Ah | — | — | 120 | — | 60 |

For each battery type the smallest and the largest configuration; new batteries, 25 °C. AEC published figures or EMEA 2026 catalogue figures. Every option is in the chart and the table of codes.

#### All 7 ordering codes of the All-in-One 20 kVA and their backup times

**All-in-One 20 kVA: ordering codes and backup time in minutes at the load shown**

| Code | Batteries | Cabinet | 100% | 90% | 80% | 70% | 60% | 50% |
| --- | --- | --- | --- | --- | --- | --- | --- | --- |
| Lithium modules, 50 Ah |  |  |  |  |  |  |  |  |
| AIO-20K-2X50 | 2 × lithium modules 50 Ah | internal | 15 | 17 | 19 | 21 | 25 | 30 |
| AIO-20K-3X50 | 3 × lithium modules 50 Ah | internal | 22 | 25 | 28 | 32 | 37 | 45 |
| AIO-20K-4X50 | 4 × lithium modules 50 Ah | internal | 30 | 33 | 38 | 43 | 50 | 60 |
| AIO-20K-5X50 | 5 × lithium modules 50 Ah | internal | 37 | 41 | 47 | 53 | 62 | 75 |
| AIO-20K-6X50 | 6 × lithium modules 50 Ah | internal | 45 | 50 | 56 | 64 | 75 | 90 |
| AIO-20K-7X50 | 7 × lithium modules 50 Ah | internal | 52 | 58 | 65 | 75 | 87 | 105 |
| AIO-20K-8X50 | 8 × lithium modules 50 Ah | internal | 60 | 67 | 75 | 86 | 100 | 120 |

Minutes from AEC EMEA product data: from 50 to 100% load, the times AEC publishes. The chart above adds AEC's calculation from 10 to 40%.

Drag to turn

In 3D

## Look around the All-in-One 20 kVA

[Open full 3D · X-ray](https://www.aecups.com/assets/models3d/aio-20/v69/)

Technical data

## Technical data All-in-One 20 kVA

Only this model's values, from the EMEA 2026 catalogue table.

**All-in-One 20 kVA · Technical data**

|  |  |
| --- | --- |
| Model |  |
| AEC codes | AIO-20K-2X50 … AIO-20K-8X50 · AIO-20K-4X100 |
| UPS inside | IST9 20 kVA, rack 3U |
| Rated power (kVA / kW) | 20 / 20 |
| Input / output | 3/3 · 3/1 |
| Technology | online double conversion · IGBT rectifier with PFC · DSP control · battery from isolated DC/DC lithium modules |
| Input |  |
| Voltage range | phase 176–280 V full load · 80–176 V with linear derating |
| Frequency | 40–70 Hz |
| Power factor · THDi | ≥ 0.99 · ≤ 3% resistive, ≤ 5% non-linear full load |
| Output |  |
| Voltage | 220 / 230 / 240 V L-N · 380 / 400 / 415 V L-L · fine adjustment ± 5 V |
| Frequency on battery | 50 or 60 ± 0.1 Hz |
| Voltage distortion | ≤ 2% resistive full load |
| Power factor | 1.0 (kVA = kW) |
| Transfer time | < 1 ms synchronised · < 10 ms not synchronised |
| Overload | ≤ 105% continuous · 105–110% 60 min · 110–130% 10 min · 130–155% 1 min · > 155% 200 ms |
| Efficiency (AC/AC) | up to 96% · 99% in ECO mode |
| Modes | online · ECO · battery · bypass · generator · frequency converter · impact load · test load |
| Battery system |  |
| Lithium modules | 2 to 8 × 50 Ah (5.76–23.0 kWh) or 4 × 100 Ah (23.0 kWh) |
| Backup time | 15–60 min at 20 kW (50 Ah) · 60 min at 20 kW, 200 min at 6 kW (4 × 100 Ah) |
| Charge current, max. | 10 A (UPS charger); per module set from the number of modules |
| General |  |
| Communication | RS232 · EPO · RS485 · options: SNMP, RS485 + dry contact |
| System display | 4.3" touch screen, tilted, on the door, with 3-colour LED status bar · LCD of the UPS · USB for records and upgrades |
| Noise | < 65 dB at full load |
| Working temperature · humidity | UPS −5 … 40 °C · battery 0–40 °C (15–30 °C recommended) · humidity 5–95%, non-condensing |
| Altitude · protection degree | ≤ 2000 m (above: derating to [IEC 62040-3](https://webstore.iec.ch/en/publication/60140)) · IP20 |
| Earthing systems | TN-S · TN-C · TN-C-S |
| Cabinet size W × D × H (mm), on castors | 600 × 1000 × 1110 · 1000 mm high without castors |
| Cabinet weight with distribution, without UPS and modules (kg) | 138 ± 5 (50 Ah) · 134 ± 5 (100 Ah) |
| System weight (kg) | 232 (2 × 50 Ah) to 460 (8 × 50 Ah) · 352 (4 × 100 Ah) |
| UPS size W × D × H (mm) | 438 × 535 × 130 (3U) |
| UPS weight (kg) | 18.4 |

**All-in-One 20 kVA · Models**

| Item | All-in-One 20 kVA |
| --- | --- |
| UPS inside | IST9 20 kVA |
| Input / output | 3/3 · 3/1 |
| UPS height | 3U |
| Number of modules (from backup tables) | 50 Ah: 2–8 · 100 Ah: 4 |

UPS data from the IST9 user manual; system data from the AEC All-in-One 20 kVA user manual and the EMEA 2026 catalogue. Specifications are subject to change without notice.

#### **More technical details** range tables, ordering codes

Planning data

## All-in-One range tables

### Eight codes, one 20 kVA system

Every code: IST9 20 kVA, input / output 3/3 or 3/1. Weight: UPS 18.4 kg + cabinet with distribution 138 ± 5 kg (134 ± 5 kg for 100 Ah) + modules of more than 38 kg (50 Ah) or 50 kg (100 Ah) each. Backup times: reference values, to be confirmed by actual measurement; AEC sizes every system.

**All-in-One 20 kVA · Eight codes, one 20 kVA system**

| AEC code | Lithium modules | kWh | min at 20 kW | min at 10 kW | min at 6 kW | Weight (kg) |
| --- | --- | --- | --- | --- | --- | --- |
| AIO-20K-2X50 | 2 × 50 Ah | 5.76 | 15 | 30 | 50 | 232 |
| AIO-20K-3X50 | 3 × 50 Ah | 8.64 | 22 | 45 | 75 | 270 |
| AIO-20K-4X50 | 4 × 50 Ah | 11.5 | 30 | 60 | 100 | 308 |
| AIO-20K-5X50 | 5 × 50 Ah | 14.4 | 37 | 75 | 125 | 346 |
| AIO-20K-6X50 | 6 × 50 Ah | 17.3 | 45 | 90 | 150 | 384 |
| AIO-20K-7X50 | 7 × 50 Ah | 20.2 | 52 | 105 | 175 | 422 |
| AIO-20K-8X50 | 8 × 50 Ah | 23.0 | 60 | 120 | 200 | 460 |
| AIO-20K-4X100 | 4 × 100 Ah | 23.0 | 60 | 120 | 200 | 352 |

### 50 Ah modules · minutes

Backup grows one module at a time: 2 to 8 modules of 50 Ah, 2.88 kWh each. Load in kW; backup in minutes. 6 kW: catalogue reference values at 25 °C; 10 to 20 kW (50 to 100% load): AEC's product data. To be confirmed by actual measurement; AEC sizes every system. –: configuration not possible (at least two modules).

**All-in-One 20 kVA · 50 Ah modules · minutes**

| Load · modules | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
| --- | --- | --- | --- | --- | --- | --- | --- | --- |
| 6 kW | – | 50 | 75 | 100 | 125 | 150 | 175 | 200 |
| 10 kW | – | 30 | 45 | 60 | 75 | 90 | 105 | 120 |
| 12 kW | – | 25 | 37 | 50 | 62 | 75 | 87 | 100 |
| 14 kW | – | 21 | 32 | 43 | 53 | 64 | 75 | 86 |
| 16 kW | – | 19 | 28 | 38 | 47 | 56 | 65 | 75 |
| 18 kW | – | 17 | 25 | 33 | 41 | 50 | 58 | 67 |
| 20 kW | – | 15 | 22 | 30 | 37 | 45 | 52 | 60 |

### 100 Ah modules · minutes

Long backup with four 100 Ah modules, 23.0 kWh in all (AIO-20K-4X100); the 100 Ah version always has four. Catalogue reference values at 25 °C, to be confirmed by actual measurement. –: configuration not possible.

**All-in-One 20 kVA · 100 Ah modules · minutes**

| Load · modules | 1 | 2 | 3 | 4 |
| --- | --- | --- | --- | --- |
| 6 kW | – | – | – | 200 |
| 10 kW | – | – | – | 120 |
| 20 kW | – | – | – | 60 |

### One cabinet to connect · IST9 20 kVA max. steady-state current (A)

Only mains, bypass and output are wired on site; the lithium modules are already connected to the UPS inside the cabinet.

**All-in-One 20 kVA · One cabinet to connect · IST9 20 kVA max. steady-state current (A)**

| kVA | Mode | AC in | Bypass | AC out |
| --- | --- | --- | --- | --- |
| 20 | 3/3 | 35 | — | 30 |
| 20 | 3/1 | 35 | 91 | 91 |

### IST9 20 kVA · recommended breakers (A)

From the IST9 user manual. Breaker 1.5–2 × max. input current, without leakage protection.

**All-in-One 20 kVA · IST9 20 kVA · recommended breakers (A)**

| kVA | Mode | AC in | Bypass | AC out |
| --- | --- | --- | --- | --- |
| 20 | 3/3 | 63 × 3P | 50 × 3P | 50 × 3P |
| 20 | 3/1 | 63 × 3P | 125 × 1P | 125 × 1P |

### 50 Ah or 100 Ah?

Same cabinet, same UPS: the module decides the backup. Catalogue reference values; AEC sizes every system.

**All-in-One 20 kVA · 50 Ah or 100 Ah?**

|  | 50 Ah | 100 Ah |
| --- | --- | --- |
| Modules | 2 to 8, two per row | 4, one per row |
| Module width | 223 mm | 440 mm |
| Cells | 4C | 1C |
| Energy per module | 2.88 kWh | 5.76 kWh |
| Energy in all | 5.76–23.0 kWh | 23.0 kWh |
| Backup at 20 kW | 15–60 min | 60 min |
| System weight | 232–460 kg | 352 kg |
| Best for | short and medium backup | long backup, low and medium loads |

Ordering codes

## Ordering codes All-in-One 20 kVA

**Ordering codes All-in-One 20 kVA**

| Code | Description |
| --- | --- |
| AIO-20K-2X50 | IST9 20 kVA (3/3 · 3/1), distribution switches with maintenance bypass, 2 × 50 Ah lithium modules (5.76 kWh) |
| AIO-20K-3X50 | IST9 20 kVA (3/3 · 3/1), distribution switches with maintenance bypass, 3 × 50 Ah lithium modules (8.64 kWh) |
| AIO-20K-4X50 | IST9 20 kVA (3/3 · 3/1), distribution switches with maintenance bypass, 4 × 50 Ah lithium modules (11.5 kWh) |
| AIO-20K-5X50 | IST9 20 kVA (3/3 · 3/1), distribution switches with maintenance bypass, 5 × 50 Ah lithium modules (14.4 kWh) |
| AIO-20K-6X50 | IST9 20 kVA (3/3 · 3/1), distribution switches with maintenance bypass, 6 × 50 Ah lithium modules (17.3 kWh) |
| AIO-20K-7X50 | IST9 20 kVA (3/3 · 3/1), distribution switches with maintenance bypass, 7 × 50 Ah lithium modules (20.2 kWh) |
| AIO-20K-8X50 | IST9 20 kVA (3/3 · 3/1), distribution switches with maintenance bypass, 8 × 50 Ah lithium modules (23.0 kWh) |
| AIO-20K-4X100 | IST9 20 kVA (3/3 · 3/1), distribution switches with maintenance bypass, 4 × 100 Ah lithium modules (23.0 kWh), one per row |
| Options | SNMP card · dry-contact card · extra 50 Ah modules, up to 8 per cabinet |

Questions

## Questions about the All-in-One 20 kVA

#### What backup does the All-in-One 20 kVA give?

At 20 kW: 15, 22, 30, 37, 45, 52 or 60 minutes with two to eight 50 Ah modules, and 60 minutes with four 100 Ah modules. At 6 kW: 50 to 200 minutes with 50 Ah modules, 200 minutes with the 100 Ah version. Reference values, confirmed by AEC for each system.

#### Is there a single-phase All-in-One, or one above 20 kVA?

No. The All-in-One is built as 20 kVA only, three-phase input, 3/3 or 3/1: the 3/1 mode feeds single-phase loads. For a single-phase supply look at the IST3, IST3-J or IST8; for lithium above 20 kVA, at the L6 cabinets with the IST7 60–200 kVA or the IST6.

#### Can modules be added later?

Yes, with 50 Ah modules, up to eight: each module has its own DC/DC converter, so new modules work beside the ones in service and go in with the load supplied. The 100 Ah version is always four modules.

#### What are the ordering codes of the All-in-One 20 kVA?

AIO-20K-2X50 to AIO-20K-8X50 with 2 to 8 modules of 50 Ah, and AIO-20K-4X100 with four modules of 100 Ah. Tell us the load and the backup time: AEC chooses the code.

#### Lithium All-in-One or UPS with VRLA batteries?

AEC's comparison in the catalogue: one cabinet instead of UPS plus battery cabinet, installed by one person in 30–60 minutes instead of two people in 2–4 hours. The lithium lasts 10+ years with 5,000 cycles at 50% depth of discharge against 3–5 years and about 500 cycles for VRLA.

#### How long does a 20 kVA UPS like the All-in-One 20 kVA run?

15 to 60 minutes at full load (20 kW), and 30 to 120 minutes at half load, with the AEC battery options in the table: the battery chosen sets the figure. With 2 × lithium modules 50 Ah (AIO-20K-2X50): 15 minutes at 100% and 30 at 50%. For other loads and batteries use the backup-time tool.

#### How big is the AEC All-in-One 20 kVA and how much does it weigh?

The AEC All-in-One 20 kVA measures 600 × 1000 × 1110 mm; weight: 232 kg with 2 × 50 Ah, up to 460 kg with 8 × 50 Ah (EMEA 2026 catalogue).

Related models

## The same range: All-in-One

[The whole range](https://www.aecups.com/en/products/all-in-one/)

**All-in-One 20 kVA** 20 kVA

Batteries and cabinets: [L6-50](https://www.aecups.com/en/products/l6-lithium/l6-50/) [L6-100](https://www.aecups.com/en/products/l6-lithium/l6-100/) Accessories: [SNMP card](https://www.aecups.com/en/products/snmp-card/) [Dry contact card](https://www.aecups.com/en/products/dry-contact-card/)

Shared by the whole range, on the All-in-One page: [the display simulator](https://www.aecups.com/en/products/all-in-one/#display) · [how the power flows in each mode](https://www.aecups.com/en/products/all-in-one/#diagrams) · [the catalogue's photos and drawings](https://www.aecups.com/en/products/all-in-one/#gallery).

Read next: [UPS backup time: how to estimate and extend runtime](https://www.aecups.com/en/blog/ups-backup-time/) [UPS for blackouts and storms: what to know](https://www.aecups.com/en/blog/ups-for-blackouts/) [UPS batteries: VRLA vs lithium and how to choose](https://www.aecups.com/en/blog/ups-batteries-vrla-vs-lithium/)

## Talk to an AEC engineer

Tell us the load, the supply and the backup time you need for the AEC All-in-One 20 kVA: we answer with the model and the batteries that fit. AEC International sells through distributors in about 80 countries and an agency in every Italian region: ask AEC which one serves your area.

[Contact us](https://www.aecups.com/en/contacts/?interest=Three-phase%20UPS&msg=About%20the%20AEC%20All-in-One%2020%20kVA%20(All-in-One)%3A%20%0AQuantity%3A%20#form) [+39 02 9415 8991](tel:+390294158991)