Lithium and VRLA lead-acid

# Batteries and cabinets

LiFePO4 lithium cabinets with hot-swap modules, steel battery cabinets and OZ Power AGM VRLA batteries. L6 with 40, 50 or 100 Ah modules; BB1–BB8, BBJ and BBJ2 cabinets; OZ Power 12 V blocks from 9 to 200 Ah.

## Which range fits your load?

### L6 Lithium

Lithium

40 · 50 · 100 Ah

Modular lithium battery system, 40 · 50 · 100 Ah

Details

### Battery cabinets

VRLA

9–100 Ah

Battery cabinets and VRLA batteries for AEC UPS

Details

### OZ Power VRLA

VRLA

9–200 Ah

OZ Power AGM batteries 12 V

Details

Models

## One model, one page

Every rating has its own page: that model's technical data, ordering codes, batteries and the questions people ask.

**[L6 Lithium](https://www.aecups.com/en/products/l6-lithium/)** 40 · 50 · 100 Ah [L6-40](https://www.aecups.com/en/products/l6-lithium/l6-40/) · [L6-50](https://www.aecups.com/en/products/l6-lithium/l6-50/) · [L6-100](https://www.aecups.com/en/products/l6-lithium/l6-100/)

**[Battery cabinets](https://www.aecups.com/en/products/battery-cabinets/)** 9–100 Ah [BB1](https://www.aecups.com/en/products/battery-cabinets/bb1/) · [BB2](https://www.aecups.com/en/products/battery-cabinets/bb2/) · [BB3](https://www.aecups.com/en/products/battery-cabinets/bb3/) · [BBJ](https://www.aecups.com/en/products/battery-cabinets/bbj/) · [BBJ2](https://www.aecups.com/en/products/battery-cabinets/bbj2/) · [BB4](https://www.aecups.com/en/products/battery-cabinets/bb4/) · [BB5](https://www.aecups.com/en/products/battery-cabinets/bb5/) · [BB6](https://www.aecups.com/en/products/battery-cabinets/bb6/) · [BB7](https://www.aecups.com/en/products/battery-cabinets/bb7/) · [BB8](https://www.aecups.com/en/products/battery-cabinets/bb8/)

**[OZ Power VRLA](https://www.aecups.com/en/products/oz-power-vrla/)** 9–200 Ah [OZ Power 12 V 9 Ah](https://www.aecups.com/en/products/oz-power-vrla/oz-12v-9ah/) · [OZ Power 12 V 24 Ah](https://www.aecups.com/en/products/oz-power-vrla/oz-12v-24ah/) · [OZ Power 12 V 40 Ah](https://www.aecups.com/en/products/oz-power-vrla/oz-12v-40ah/) · [OZ Power 12 V 60 Ah](https://www.aecups.com/en/products/oz-power-vrla/oz-12v-60ah/) · [OZ Power 12 V 80 Ah](https://www.aecups.com/en/products/oz-power-vrla/oz-12v-80ah/) · [OZ Power 12 V 100 Ah](https://www.aecups.com/en/products/oz-power-vrla/oz-12v-100ah/) · [OZ Power 12 V 200 Ah](https://www.aecups.com/en/products/oz-power-vrla/oz-12v-200ah/)

Comparison

## Batteries and cabinets: how do the ranges compare?

| Range | Ratings | Voltage | Description | Batteries |
| --- | --- | --- | --- | --- |
| [L6 Lithium](https://www.aecups.com/en/products/l6-lithium/) | 40 · 50 · 100 Ah | 240 / ±240 / 480 V DC | Modular lithium battery system, 40 · 50 · 100 Ah | Lithium |
| [Battery cabinets](https://www.aecups.com/en/products/battery-cabinets/) | 9–100 Ah | 12 V VRLA AGM · ±240 V DC | Battery cabinets and VRLA batteries for AEC UPS | VRLA |
| [OZ Power VRLA](https://www.aecups.com/en/products/oz-power-vrla/) | 9–200 Ah | 12 V | OZ Power AGM batteries 12 V | VRLA |

Questions

## Questions people ask

#### Lithium or VRLA: which battery should I choose for my UPS?

The L6 uses lithium iron phosphate modules rated for 5,000 cycles at 50% depth of discharge, hot-swappable and monitored by a three-layer BMS, for AEC IST7 and IST6 UPS from 6 to 1200 kVA. OZ Power VRLA AGM batteries are sealed and maintenance-free, with a design life of 6–8 years (9–24 Ah) or 12 years (40–200 Ah), and go into AEC battery cabinets.

#### How do lithium and VRLA cabinets compare in size?

An L6 cabinet measures 600 × 850 × 2000 mm and stores up to 41, 58 or 69 kWh depending on the module. VRLA cabinets range from the BB5 at 460 × 800 × 1400 mm to the BB8 at 1400 × 800 × 1900 mm, which holds up to 64 batteries of 80 or 100 Ah in two strings.

#### How does maintenance differ between lithium and VRLA?

VRLA cabinets need monthly visual checks, battery voltages every 6 months, terminal torque every 12 months and a capacity test or replacement every 3–5 years. L6 maintenance is done online, module by module: a faulty module leaves the system on its own and is replaced in about 5 minutes.

#### Which OZ Power battery goes in which AEC cabinet?

The 9 Ah block goes in the UPS and in BB1–BB5 and BBJ cabinets, 24 and 40 Ah in the BB5, 60 Ah in BB6 and BB7, and 80 and 100 Ah in BB7 and BB8. The 200 Ah block is for large systems, on request.

#### Who sizes the battery for my project?

AEC sizes the battery for every project: send the loads and the backup time required to sales@aecups.com or +39 02 9415 8991. AEC engineers choose the module or battery type, the quantity, the cabinets and the reserve.

Guides

## Guides: Batteries and cabinets

[All guides](https://www.aecups.com/en/blog/)

[**Battery room ventilation to EN IEC 62485-2 for VRLA** The EN IEC 62485-2 air flow for a VRLA battery, term by term, worked out for every AEC BB4–BB8 cabinet, with the size of the openings.](https://www.aecups.com/en/blog/battery-room-ventilation/) [**L6 lithium battery sizing: modules, cabinets, room** How AEC sizes an L6 lithium battery for an IST7 or IST6 UPS: power and energy counts, modules and cabinets for 10 to 30 minutes, floor and clearances.](https://www.aecups.com/en/blog/l6-lithium-battery-sizing/) [**UPS installation clearances: what to check on site** Clearances, operating gangways, door widths, floor load, cable entry and airflow for every AEC EMEA UPS and battery cabinet, before the delivery.](https://www.aecups.com/en/blog/ups-installation-clearances/)

## Talk to an AEC engineer

Tell us the load, the supply and the backup time you need: we answer with the model and the batteries that fit.

[Contact us](https://www.aecups.com/en/contacts/#form) [+39 02 9415 8991](tel:+390294158991)