# BB1 Battery cabinet for UPS, 6 × 9 Ah

VRLA 6 × 9 Ah battery cabinet for AEC UPS

The BB1 is a tower battery cabinet for the IST3 1 kVA: 145 × 360 × 225 mm, 4 kg empty, for up to six 12 V 9 Ah batteries. For an IST3 1 kVA that needs more than its 3 minutes at full load, standing beside the UPS in the same style.

**145 × 360 × 225 mm** W × D × H

**4 kg empty** Weight

**up to 6 × 12 V 9 Ah** Battery

Technical data [Catalogue (PDF)](https://www.aecups.com/docs/AEC_UPS_Catalogue_EMEA_2026.pdf#page=180) [Contact us](https://www.aecups.com/en/contacts/?interest=Battery%20cabinets%20and%20VRLA%20batteries&msg=About%20the%20AEC%20BB1%20(Battery%20cabinets)%3A%20%0AQuantity%3A%20#form)

[**Try 3D** X-ray view](https://www.aecups.com/assets/models3d/bb1/v54/)

Quick answers

## BB1: quick answers

**What it is**: The BB1 is a tower battery cabinet for the IST3 1 kVA: 145 × 360 × 225 mm, 4 kg empty, for up to six 12 V 9 Ah batteries.

**Who it is for**: For an IST3 1 kVA that needs more than its 3 minutes at full load, standing beside the UPS in the same style.

**Supply and configuration**: 12 V 9 Ah VRLA AGM blocks, at the UPS battery voltage

**Battery and backup**: up to 6 × 12 V 9 Ah

**Size and weight**: 145 × 360 × 225 mm · 4 kg empty

**Ordering code**: BB1

Battery cabinets

## What sets apart the BB1

The BB1 has the same footprint as the IST3 1 kVA it extends, within a few millimetres, so the two stand side by side as a pair. With six batteries the UPS and cabinet are ordered as one code, IST3-1-6X9. The batteries are OZ Power 12 V 9 Ah AGM blocks, the same as inside the UPS.

The number of batteries per UPS is set by the UPS battery voltage: 24 V on the standard IST3-1, 36 V on the long backup IST3-1-L. AEC wires the cabinet for the UPS it is ordered with.

Installation

## Installing the BB1: space, cables

Each figure with its source.

**BB1 · installation**

| Item | Figure | Source |
| --- | --- | --- |
| Cable entry | Rear connector | AEC EMEA product data; EMEA 2026 catalogue p.184 |

Size and floor

## How big it is

145 × 360 × 225 mm · 4 kg empty.

**0.05 m²** footprint

**0.23 m** height

Drag to turn

In 3D

## Look around the BB1

[Open full 3D · X-ray](https://www.aecups.com/assets/models3d/bb1/v54/)

Technical data

## Technical data BB1

Only this model's values, from the EMEA 2026 catalogue table.

**BB1 · Models**

| Item | BB1 |
| --- | --- |
| For UPS | IST3 1 kVA |
| W × D × H (mm) | 145 × 360 × 225 |
| kg, empty | 4 |
| Batteries (12 V) | up to 6 × 9 Ah |

Figures from the AEC UPS Catalogue EMEA 2026. 1.0, 2026). VRLA batteries have a 1-year warranty for 9 Ah blocks and 2 years for larger blocks. Specifications are subject to change without notice.

#### **More technical details** ordering codes

Ordering codes

## Ordering codes BB1

**Ordering codes BB1**

| Code | Description |
| --- | --- |
| BB1 · BB2 · BB3 | Tower cabinets for IST3 1 kVA · 2–3 kVA · 6–10 kVA (max 6 · 12 · 32 × 12 V 9 Ah) |
| OZ Power 12 V | 9 · 24 · 40 · 60 · 80 · 100 · 200 Ah · code on request |

Questions

## Questions about the BB1

#### Which UPS does the BB1 go with?

The IST3 1 kVA tower, in the code IST3-1-6X9 (UPS plus BB1 with 6 × 12 V 9 Ah). Larger IST3 use the BB2 (2–3 kVA) or BB3 (6–10 kVA).

#### Which batteries go in the BB1?

OZ Power 12 V 9 Ah AGM blocks, 151 × 65 × 94 mm and 2.3 kg each, with a design life of 6–8 years in float at 25 °C. Use the same model, capacity and batch across the whole string.

#### How big is the AEC BB1 and how much does it weigh?

The AEC BB1 measures 145 × 360 × 225 mm; weight: 4 kg empty (EMEA 2026 catalogue).

Related models

## The same range: Battery cabinets

[The whole range](https://www.aecups.com/en/products/battery-cabinets/)

**BB1** 6 × 9 Ah [**BB2** 12 × 9 Ah · larger rating](https://www.aecups.com/en/products/battery-cabinets/bb2/) [**BB3** 32 × 9 Ah](https://www.aecups.com/en/products/battery-cabinets/bb3/) [**BBJ** 2U · 8 × 9 Ah](https://www.aecups.com/en/products/battery-cabinets/bbj/) [**BBJ2** 3U · 16 × 9 Ah](https://www.aecups.com/en/products/battery-cabinets/bbj2/) [**BB4** 80 × 9 Ah](https://www.aecups.com/en/products/battery-cabinets/bb4/) [**BB5** 24 · 40 Ah](https://www.aecups.com/en/products/battery-cabinets/bb5/) [**BB6** 60 Ah](https://www.aecups.com/en/products/battery-cabinets/bb6/) [**BB7** 60 · 80 · 100 Ah](https://www.aecups.com/en/products/battery-cabinets/bb7/) [**BB8** 80 · 100 Ah, 2 strings](https://www.aecups.com/en/products/battery-cabinets/bb8/)

Shared by the whole range, on the Battery cabinets page: [the catalogue's photos and drawings](https://www.aecups.com/en/products/battery-cabinets/#gallery).

Read next: [Battery room ventilation to EN IEC 62485-2 for VRLA](https://www.aecups.com/en/blog/battery-room-ventilation/) [UPS datasheet explained: every line, with examples](https://www.aecups.com/en/blog/how-to-read-a-ups-datasheet/) [UPS batteries: VRLA vs lithium and how to choose](https://www.aecups.com/en/blog/ups-batteries-vrla-vs-lithium/)

## Talk to an AEC engineer

Tell us the load, the supply and the backup time you need for the AEC BB1: we answer with the model and the batteries that fit. AEC International sells through distributors in about 80 countries and an agency in every Italian region: ask AEC which one serves your area.

[Contact us](https://www.aecups.com/en/contacts/?interest=Battery%20cabinets%20and%20VRLA%20batteries&msg=About%20the%20AEC%20BB1%20(Battery%20cabinets)%3A%20%0AQuantity%3A%20#form) [+39 02 9415 8991](tel:+390294158991)