# BBJ Battery cabinet for UPS, 2U · 8 × 9 Ah

VRLA 2U · 8 × 9 Ah battery cabinet for AEC UPS

The BBJ is a 2U rack battery cabinet for the IST3-J 1–3 kVA: 438 × 413 mm, 6 kg empty, for up to eight 12 V 9 Ah batteries. For racks with an IST3-J 1–3 kVA that need more than 3 minutes, without leaving the 19-inch cabinet.

**438 × 413 mm, 2U** W × D × H

**6 kg empty** Weight

**up to 8 × 12 V 9 Ah** Battery

Technical data [Catalogue (PDF)](https://www.aecups.com/docs/AEC_UPS_Catalogue_EMEA_2026.pdf#page=180) [Contact us](https://www.aecups.com/en/contacts/?interest=Battery%20cabinets%20and%20VRLA%20batteries&msg=About%20the%20AEC%20BBJ%20(Battery%20cabinets)%3A%20%0AQuantity%3A%20#form)

[**Try 3D** X-ray view](https://www.aecups.com/assets/models3d/ist3j-1/v86/#tower&cab-bbj-1-right)

Quick answers

## BBJ: quick answers

**What it is**: The BBJ is a 2U rack battery cabinet for the IST3-J 1–3 kVA: 438 × 413 mm, 6 kg empty, for up to eight 12 V 9 Ah batteries.

**Who it is for**: For racks with an IST3-J 1–3 kVA that need more than 3 minutes, without leaving the 19-inch cabinet.

**Supply and configuration**: 12 V 9 Ah VRLA AGM blocks, at the UPS battery voltage

**Battery and backup**: up to 8 × 12 V 9 Ah

**Size and weight**: 438 × 413 mm, 2U · 6 kg empty

**Ordering code**: BBJ

Battery cabinets

## What sets apart the BBJ

The BBJ takes two rack units below the IST3-J and holds up to eight 9 Ah blocks; up to three BBJ can be connected to one UPS. The codes read UPS, rating and total batteries: IST3J-\[kVA\]-\[n\]X9. Heavy units always go below the UPS in the rack.

On the IST3-J 1–3 kVA the charger gives 1 A by default; with the optional 7 A charging module it can be set from 2 to 8 A, and the catalogue recommends 0.1–0.2 C of the battery capacity, a reason to fit the module when two or three BBJ are added. Battery packs are hot-pluggable from the front.

In 3D

## Look around the BBJ

[Open full 3D · X-ray](https://www.aecups.com/assets/models3d/ist3j-1/v86/#tower&cab-bbj-1-right)

The BBJ is drawn beside the IST3-J 1 kVA it is sold with: the full 3D view opens on the pair, and its "Battery cabinet" menu changes how many and on which side.

Technical data

## Technical data BBJ

Only this model's values, from the EMEA 2026 catalogue table.

**BBJ · Models**

| Item | BBJ |
| --- | --- |
| For UPS | IST3-J 1–3 kVA, rack |
| W × D × H (mm) | 438 × 413 × 2U |
| kg, empty | 6 |
| Batteries (12 V) | up to 8 × 9 Ah |

Figures from the AEC UPS Catalogue EMEA 2026. 1.0, 2026). VRLA batteries have a 1-year warranty for 9 Ah blocks and 2 years for larger blocks. Specifications are subject to change without notice.

#### **More technical details** ordering codes

Ordering codes

## Ordering codes BBJ

**Ordering codes BBJ**

| Code | Description |
| --- | --- |
| BBJ · BBJ2 | Rack cabinets 2U (max 8 × 9 Ah) and 3U (max 16 × 9 Ah) |
| OZ Power 12 V | 9 · 24 · 40 · 60 · 80 · 100 · 200 Ah · code on request |

Questions

## Questions about the BBJ

#### How many BBJ can one IST3-J take?

Up to three BBJ per IST3-J 1–3 kVA, each 2U with up to 8 × 12 V 9 Ah. For the 6–10 kVA, use the 3U BBJ2.

#### What charge current suits an IST3-J with BBJ cabinets?

The catalogue recommends 0.1–0.2 C of the battery capacity. The UPS gives 1 A by default and 2–8 A only with the optional 7 A charging module.

#### How big is the AEC BBJ and how much does it weigh?

The AEC BBJ measures 438 × 413 mm, 2U; weight: 6 kg empty (EMEA 2026 catalogue).

Related models

## The same range: Battery cabinets

[The whole range](https://www.aecups.com/en/products/battery-cabinets/)

[**BB1** 6 × 9 Ah](https://www.aecups.com/en/products/battery-cabinets/bb1/) [**BB2** 12 × 9 Ah](https://www.aecups.com/en/products/battery-cabinets/bb2/) [**BB3** 32 × 9 Ah · smaller rating](https://www.aecups.com/en/products/battery-cabinets/bb3/) **BBJ** 2U · 8 × 9 Ah [**BBJ2** 3U · 16 × 9 Ah · larger rating](https://www.aecups.com/en/products/battery-cabinets/bbj2/) [**BB4** 80 × 9 Ah](https://www.aecups.com/en/products/battery-cabinets/bb4/) [**BB5** 24 · 40 Ah](https://www.aecups.com/en/products/battery-cabinets/bb5/) [**BB6** 60 Ah](https://www.aecups.com/en/products/battery-cabinets/bb6/) [**BB7** 60 · 80 · 100 Ah](https://www.aecups.com/en/products/battery-cabinets/bb7/) [**BB8** 80 · 100 Ah, 2 strings](https://www.aecups.com/en/products/battery-cabinets/bb8/)

Shared by the whole range, on the Battery cabinets page: [the catalogue's photos and drawings](https://www.aecups.com/en/products/battery-cabinets/#gallery).

Read next: [Battery room ventilation to EN IEC 62485-2 for VRLA](https://www.aecups.com/en/blog/battery-room-ventilation/) [UPS datasheet explained: every line, with examples](https://www.aecups.com/en/blog/how-to-read-a-ups-datasheet/) [UPS batteries: VRLA vs lithium and how to choose](https://www.aecups.com/en/blog/ups-batteries-vrla-vs-lithium/)

## Talk to an AEC engineer

Tell us the load, the supply and the backup time you need for the AEC BBJ: we answer with the model and the batteries that fit. AEC International sells through distributors in about 80 countries and an agency in every Italian region: ask AEC which one serves your area.

[Contact us](https://www.aecups.com/en/contacts/?interest=Battery%20cabinets%20and%20VRLA%20batteries&msg=About%20the%20AEC%20BBJ%20(Battery%20cabinets)%3A%20%0AQuantity%3A%20#form) [+39 02 9415 8991](tel:+390294158991)