# BBJ2 Battery cabinet for UPS, 3U · 16 × 9 Ah

VRLA 3U · 16 × 9 Ah battery cabinet for AEC UPS

The BBJ2 is a 3U rack battery cabinet for the IST3-J 6–10 kVA and the IST9 20 kVA: 438 × 500 mm, 10 kg empty, for up to sixteen 12 V 9 Ah batteries. For long backup on rack UPS of 6 to 20 kVA, with everything in one 19-inch rack.

**438 × 500 mm, 3U** W × D × H

**10 kg empty** Weight

**up to 16 × 12 V 9 Ah** Battery

Technical data [Catalogue (PDF)](https://www.aecups.com/docs/AEC_UPS_Catalogue_EMEA_2026.pdf#page=180) [Contact us](https://www.aecups.com/en/contacts/?interest=Battery%20cabinets%20and%20VRLA%20batteries&msg=About%20the%20AEC%20BBJ2%20(Battery%20cabinets)%3A%20%0AQuantity%3A%20#form)

[**Try 3D** X-ray view](https://www.aecups.com/assets/models3d/ist3j-10/v83/#tower&cab-bbj2-1-right)

Quick answers

## BBJ2: quick answers

**What it is**: The BBJ2 is a 3U rack battery cabinet for the IST3-J 6–10 kVA and the IST9 20 kVA: 438 × 500 mm, 10 kg empty, for up to sixteen 12 V 9 Ah batteries.

**Who it is for**: For long backup on rack UPS of 6 to 20 kVA, with everything in one 19-inch rack.

**Supply and configuration**: 12 V 9 Ah VRLA AGM blocks, at the UPS battery voltage

**Battery and backup**: up to 16 × 12 V 9 Ah

**Size and weight**: 438 × 500 mm, 3U · 10 kg empty

**Ordering code**: BBJ2

Battery cabinets

## What sets apart the BBJ2

The BBJ2 is the battery for the external-battery rack models: up to eight per IST3-J 6–10 kVA (16 to 128 batteries, codes IST3J-6/10-\[n\]X9) and up to ten per IST9 20 kVA (32 to 160 batteries, codes IST9-20-\[n\]X9). The catalogue's rack example is an IST3-J 6–10 kVA with two BBJ2 of 16 × 9 Ah each, 3U apiece, below the UPS.

On the IST3-J 6–10 kVA the battery is 192 V by default, 12 to 20 blocks of 12 V set through communication, drawing up to 39 A (6 kVA) or 65 A (10 kVA). On the IST9 the catalogue asks for the battery box below the UPS and a DC battery switch between battery and UPS.

In 3D

## Look around the BBJ2

[Open full 3D · X-ray](https://www.aecups.com/assets/models3d/ist3j-10/v83/#tower&cab-bbj2-1-right)

The BBJ2 is drawn beside the IST3-J 10 kVA it is sold with: the full 3D view opens on the pair, and its "Battery cabinet" menu changes how many and on which side.

Technical data

## Technical data BBJ2

Only this model's values, from the EMEA 2026 catalogue table.

**BBJ2 · Models**

| Item | BBJ2 |
| --- | --- |
| For UPS | IST3-J 6–10 kVA, IST9, rack |
| W × D × H (mm) | 438 × 500 × 3U |
| kg, empty | 10 |
| Batteries (12 V) | up to 16 × 9 Ah |

Figures from the AEC UPS Catalogue EMEA 2026. 1.0, 2026). VRLA batteries have a 1-year warranty for 9 Ah blocks and 2 years for larger blocks. Specifications are subject to change without notice.

#### **More technical details** ordering codes

Ordering codes

## Ordering codes BBJ2

**Ordering codes BBJ2**

| Code | Description |
| --- | --- |
| BBJ · BBJ2 | Rack cabinets 2U (max 8 × 9 Ah) and 3U (max 16 × 9 Ah) |
| OZ Power 12 V | 9 · 24 · 40 · 60 · 80 · 100 · 200 Ah · code on request |

Questions

## Questions about the BBJ2

#### How many BBJ2 can an IST9 20 kVA take?

2, 4, 6, 8 or 10 cabinets, that is 32, 64, 96, 128 or 160 × 12 V 9 Ah (codes IST9-20-\[n\]X9). A DC battery switch goes between battery and UPS.

#### Where does the BBJ2 go, above or below the UPS?

Always below: battery cabinets are the heavy units of the rack. On the IST9 the optional distribution module goes above the UPS and the battery box below it.

#### How big is the AEC BBJ2 and how much does it weigh?

The AEC BBJ2 measures 438 × 500 mm, 3U; weight: 10 kg empty (EMEA 2026 catalogue).

Related models

## The same range: Battery cabinets

[The whole range](https://www.aecups.com/en/products/battery-cabinets/)

[**BB1** 6 × 9 Ah](https://www.aecups.com/en/products/battery-cabinets/bb1/) [**BB2** 12 × 9 Ah](https://www.aecups.com/en/products/battery-cabinets/bb2/) [**BB3** 32 × 9 Ah](https://www.aecups.com/en/products/battery-cabinets/bb3/) [**BBJ** 2U · 8 × 9 Ah · smaller rating](https://www.aecups.com/en/products/battery-cabinets/bbj/) **BBJ2** 3U · 16 × 9 Ah [**BB4** 80 × 9 Ah · larger rating](https://www.aecups.com/en/products/battery-cabinets/bb4/) [**BB5** 24 · 40 Ah](https://www.aecups.com/en/products/battery-cabinets/bb5/) [**BB6** 60 Ah](https://www.aecups.com/en/products/battery-cabinets/bb6/) [**BB7** 60 · 80 · 100 Ah](https://www.aecups.com/en/products/battery-cabinets/bb7/) [**BB8** 80 · 100 Ah, 2 strings](https://www.aecups.com/en/products/battery-cabinets/bb8/)

Shared by the whole range, on the Battery cabinets page: [the catalogue's photos and drawings](https://www.aecups.com/en/products/battery-cabinets/#gallery).

Read next: [Battery room ventilation to EN IEC 62485-2 for VRLA](https://www.aecups.com/en/blog/battery-room-ventilation/) [UPS datasheet explained: every line, with examples](https://www.aecups.com/en/blog/how-to-read-a-ups-datasheet/) [UPS batteries: VRLA vs lithium and how to choose](https://www.aecups.com/en/blog/ups-batteries-vrla-vs-lithium/)

## Talk to an AEC engineer

Tell us the load, the supply and the backup time you need for the AEC BBJ2: we answer with the model and the batteries that fit. AEC International sells through distributors in about 80 countries and an agency in every Italian region: ask AEC which one serves your area.

[Contact us](https://www.aecups.com/en/contacts/?interest=Battery%20cabinets%20and%20VRLA%20batteries&msg=About%20the%20AEC%20BBJ2%20(Battery%20cabinets)%3A%20%0AQuantity%3A%20#form) [+39 02 9415 8991](tel:+390294158991)