# CPSS 10–200 Central power supply (CPSS) to EN 50171

VRLA

The AEC CPSS7 is a three-phase central power supply system designed to EN 50171 and built on the IST7 platform: ten ratings from 10 to 200 kVA (8 to 160 kW) in four frames, online double conversion with 0 ms transfer to battery, 120% constant overload without time limit, and recharge in under 12 hours.

**EN 50171** central supply for safety services

**8–160 kW** ten ratings, four frames

**0 ms** transfer to battery

**THD < 1%** sine wave on linear loads

Datasheet Manuals and catalogues [Contact us](https://www.aecups.com/en/contacts/?msg=About%20the%20AEC%20CPSS%2010%E2%80%93200%3A%20%0AQuantity%3A%20#form)

Overview

## Key facts

**Ratings**: 10–200 kVA

**Voltage**: L-N 220 / 230 / 240 V · L-L 380 / 400 / 415 V

**Power factor · THDi**: ≥ 0.99 · ≤ 3%

**Voltage · frequency**: L-N 220 / 230 / 240 V ± 1% · L-L 380 / 400 / 415 V ± 1% · 50 / 60 Hz ± 0.1%

**Power factor · waveform**: 0.8 · pure sine wave, THD < 1% linear

**Efficiency · overload**: 96% · constant up to 120%

**Battery life · recharge**: 10–12 years · < 12 hours

**Noise · temperature · humidity**: < 65 dB · 0–40 °C · 0–95%

**Standards**: CE · EN 50171 · [EN 62040-1](https://webstore.iec.ch/en/publication/80573) · [EN 62040-2](https://webstore.iec.ch/en/publication/33696) · [EN 62040-3](https://webstore.iec.ch/en/publication/60140)

**Connectivity**: ·

[Applications](https://www.aecups.com/en/applications/): Hospitals Schools Museums Cinemas and theatres Hotels Shopping centres

Models

## Choose your CPSS 10–200.

Central power supply system to EN 50171, 10–200 kVA

**CPSS7-10** 8 **±96 … ±240**Battery voltage (V DC) **1–10**Max. charging current (A)

**CPSS7-20** 16 **±144 … ±240**Battery voltage (V DC) **1–10**Max. charging current (A)

**CPSS7-30** 24 **±144 … ±240**Battery voltage (V DC) **1–20**Max. charging current (A)

**CPSS7-40** 32 **±144 … ±240**Battery voltage (V DC) **1–20**Max. charging current (A)

**CPSS7-60** 48 **±168 … ±288**Battery voltage (V DC) **1–30**Max. charging current (A)

**CPSS7-80** 64 **±168 … ±288**Battery voltage (V DC) **1–30**Max. charging current (A)

**CPSS7-100** 80 **±168 … ±288**Battery voltage (V DC) **1–30**Max. charging current (A)

**CPSS7-120** 96 **±168 … ±288**Battery voltage (V DC) **1–30**Max. charging current (A)

**CPSS7-160** 128 **±168 … ±288**Battery voltage (V DC) **1–40**Max. charging current (A)

**CPSS7-200** 160 **±168 … ±288**Battery voltage (V DC) **1–40**Max. charging current (A)

**CPSS 10–200 Models**

| Model | Output power (kW) | Battery voltage (V DC) | Max. charging current (A) | W × D × H (mm) | Weight (kg), without / with internal batteries |
| --- | --- | --- | --- | --- | --- |
| CPSS7-10 | 8 | ±96 … ±240 | 1–10 | 250 × 806 × 880 | 64 / 95 |
| CPSS7-20 | 16 | ±144 … ±240 | 1–10 | 250 × 806 × 880 | 64 / 137.6 |
| CPSS7-30 | 24 | ±144 … ±240 | 1–20 | 300 × 842 × 1250 | 102.5 / 249.7 |
| CPSS7-40 | 32 | ±144 … ±240 | 1–20 | 300 × 842 × 1250 | 102.5 / 249.7 |
| CPSS7-60 | 48 | ±168 … ±288 | 1–30 | 400 × 960 × 1193 | 153 |
| CPSS7-80 | 64 | ±168 … ±288 | 1–30 | 400 × 960 × 1193 | 163 |
| CPSS7-100 | 80 | ±168 … ±288 | 1–30 | 400 × 960 × 1193 | 165 |
| CPSS7-120 | 96 | ±168 … ±288 | 1–30 | 400 × 960 × 1193 | 167 |
| CPSS7-160 | 128 | ±168 … ±288 | 1–40 | 600 × 1000 × 1600 | 294 |
| CPSS7-200 | 160 | ±168 … ±288 | 1–40 | 600 × 1000 × 1600 | 296 |

Datasheet

## Datasheet CPSS 10–200.

Every model side by side: keep only what differs, take it as CSV or print it.

**CPSS 10–200 · Technical data**

| Model | CPSS7-10 · 20 | CPSS7-30 · 40 | CPSS7-60 … 120 | CPSS7-160 · 200 |
| --- | --- | --- | --- | --- |
| Model |  |  |  |  |
| Output power (kW) | 8 · 16 | 24 · 32 | 48 · 64 · 80 · 96 | 128 · 160 |
| Frame | Tower | Cabinet |  |  |
| Input |  |  |  |  |
| Voltage · frequency | 80–280 V L-N / 138–485 V L-L · 40–70 Hz | 380 / 400 / 415 V (138–485 V L-L) · 40–70 Hz |  |  |
| Power factor · THDi | ≥ 0.99 · ≤ 3% |  |  |  |
| Configurations | 3:3 · 3:1 · 1:1 | 3-4W + PE |  |  |
| Output |  |  |  |  |
| Voltage · frequency | L-N 220 / 230 / 240 V ± 1% · L-L 380 / 400 / 415 V ± 1% · 50 / 60 Hz ± 0.1% |  |  |  |
| Power factor · waveform | 0.8 · pure sine wave, THD < 1% linear |  |  |  |
| Efficiency · overload | 96% · constant up to 120% |  |  |  |
| Battery |  |  |  |  |
| Voltage (V DC) | ±96 … ±240 (10) · ±144 … ±240 (20) | ±144 … ±240 | ±168 … ±288, external |  |
| Charging current | 1–10 A | 1–20 A | 1–30 A | 1–40 A |
| Battery life · recharge | 10–12 years · < 12 hours |  |  |  |
| General |  |  |  |  |
| W × D × H (mm) | 250 × 806 × 880 | 300 × 842 × 1250 | 400 × 960 × 1193 | 600 × 1000 × 1600 |
| Weight (kg) | 64 · with internal batteries 95 (10 kVA), 137.6 (20 kVA) | 102.5 · with internal batteries 249.7 | 153 · 163 · 165 · 167 | 294 · 296 |
| Noise · temperature · humidity | < 65 dB · 0–40 °C · 0–95% |  |  |  |
| Standards | CE · EN 50171 · EN 62040-1 · EN 62040-2 · EN 62040-3 |  |  |  |

From the AEC UPS Catalogue EMEA 2026, CPSS7 pages. Weights as the AEC IST7 of the same rating (same body): without internal batteries, and with them where the 10–40 kVA towers carry them. All information is indicative and may be modified by AEC at any time.

#### **Full technical details** 5 sections of the EMEA 2026 catalogue: functions, panel, connections, diagrams and ordering codes

### Why CPSS 10–200

01 **Inverter** Three-level, digital. Pure sine wave, THD ≤ 1% on linear loads; output 220 / 230 / 240 V L-N, 50 / 60 Hz ± 0.1%.

02 **Overload** Constant 120%: lamps and drives start together after a blackout, and the inverter carries 120% without time limit.

03 **Charger** Charging current set to the battery: 1–10 A on 10–20 kVA, 1–20 A on 30–40 kVA, 1–30 A on 60–120 kVA, 1–40 A on 160–200 kVA.

04 **Input** Clean for the grid: input PF ≥ 0.99, THDi ≤ 3%, wide input window: works with generators and weak grids.

WHAT A CPSS IS

## Safety services, powered from one battery

A central power supply system feeds the safety services of a building from one battery, during a fire, an earthquake or a blackout. It must comply with EN 50171, which calls for a CPSS in crowded areas and public places.

- It supplies emergency lighting, smoke extraction, fire-fighting equipment, alarm systems, CO detection and exit signs.
- Required in hospitals, schools, museums, cinemas and theatres, hotels, shopping centres, offices and workplaces, car parks and tunnels.
- What the CPSS7 provides: batteries with 10–12 years expected life, 120% constant overload, recharge from low battery in under 12 h, casing resistant to heat and fire.
- UPS and CPSS are not interchangeable: same components, different standards and uses. The installation of the safety system remains the responsibility of the installer.

HOW IT WORKS

## Built on the AEC IST7 platform

CPSS7 uses the IST7 three-level inverter and digital control, with ratings, overload and charging set for safety services. With mains present the safety loads run on the inverter and the battery charges; in a blackout the battery takes over with no break (0 ms).

- Overload or fault: load on the static bypass, < 1 ms synchronised; service: maintenance bypass, the load stays on the mains.
- Colour touch screen with live single-line diagram, two access levels, battery test and event records with time stamp.
- RS485 standard, dry contacts OUT.1–OUT.5, input contacts for battery ground fault, EPO and IN.1; SNMP and relay cards in the intelligent slots.

THE RANGE

## Four frames, 10 to 200 kVA

CPSS7 10–40 kVA in two compact towers with internal or external batteries, CPSS7 60–200 kVA in two cabinets with external batteries. Output power factor 0.8 (kW = 0.8 × kVA).

- CPSS7-10 · 20: 8 · 16 kW, tower 250 × 806 × 880 mm.
- CPSS7-30 · 40: 24 · 32 kW, tower 300 × 842 × 1250 mm.
- CPSS7-60 · 80 · 100 · 120: 48 · 64 · 80 · 96 kW, cabinet 400 × 960 × 1193 mm.
- CPSS7-160 · 200: 128 · 160 kW, cabinet 600 × 1000 × 1600 mm.
- Input 40–70 Hz; configurations 3:3 · 3:1 · 1:1 on 10–40 kVA; 96% efficiency in double conversion; noise < 65 dB, 0–40 °C, 0–95% RH.

ORDERING AND SYSTEMS

## Sized on the project, up to four in parallel

AEC sizes a CPSS in three steps: the load (safety loads in kW with their starting peaks; the 120% overload covers simultaneous starts), the backup time set by the fire-safety design of the building, and the site (ventilated battery room or cabinet, periodic function and duration tests, event records kept by the CPSS).

- Codes: CPSS7-10 · 20, CPSS7-30 · 40, CPSS7-60 · 80 · 100 · 120, CPSS7-160 · 200; battery cabinets BB4 … BB8 with fuses and Q1 disconnector, empty or with OZ Power batteries.
- Options: SNMP card, relay / RS485 card, parallel kit, battery temperature sensor.
- Up to four CPSS7 in parallel, redundant or for more power; a unit with a fault leaves the system by itself, with an alarm; batteries can be shared.
- Fire-safety rules and required backup time depend on the building and the country: AEC sizes each CPSS on the project data.

Diagrams

## The CPSS 10–200, in diagrams

The path of the power, the ratings, the footprints and the losses, drawn from the figures of the EMEA 2026 catalogue.

### The ratings

Every model in the range, in proportion to its power.

1. CPSS7-10 **10 kVA · 8 kW**
2. CPSS7-20 **20 kVA · 16 kW**
3. CPSS7-30 **30 kVA · 24 kW**
4. CPSS7-40 **40 kVA · 32 kW**
5. CPSS7-60 **60 kVA · 48 kW**
6. CPSS7-80 **80 kVA · 64 kW**
7. CPSS7-100 **100 kVA · 80 kW**
8. CPSS7-120 **120 kVA · 96 kW**
9. CPSS7-160 **160 kVA · 128 kW**
10. CPSS7-200 **200 kVA · 160 kW**

### Phase configurations

Input / output: three-phase (3) or single-phase (1). 3/1 · 1/1 on 10–40 kVA; 60–200 kVA 3-4W + PE.

**3/3** 3~ → 3~

**3/1** 3~ → 1~

**1/1** 1~ → 1~

### Footprints to scale

Front view of the cabinets, all at the same scale, beside a 2 m rule. W × D × H, mm.

- **10–20 kVA** 250 × 806 × 880 mm · 64 kg · 95 kg (10 kVA) / 137.6 kg (20 kVA) with internal batteries
- **30–40 kVA** 300 × 842 × 1,250 mm · 102.5 kg · 249.7 kg with internal batteries
- **60–120 kVA** 400 × 960 × 1,193 mm · 153 (60) · 163 (80) · 165 (100) · 167 (120) kg
- **160–200 kVA** 600 × 1,000 × 1,600 mm · 294 (160) · 296 (200) kg

In the same family: [CPSS 1–10](https://www.aecups.com/en/products/cpss-1-10/) [Central power supply (CPSS)](https://www.aecups.com/en/products/cpss-en-50171/)

Guides

## Guides on the CPSS 10–200

[All guides](https://www.aecups.com/en/blog/)

[**CPSS to EN 50171: what it asks and how to size one** A CPSS is a central battery system that powers emergency lighting and safety loads. What EN 50171 covers, how to size a CPSS and a worked example.](https://www.aecups.com/en/blog/cpss-en-50171/) [**UPS vs CPSS: which one does a building need?** A UPS keeps equipment running; a CPSS keeps safety systems such as emergency lighting on. How they differ and when a building needs both.](https://www.aecups.com/en/blog/ups-vs-cpss/) [**UPS for hospitals and healthcare facilities** A UPS for hospitals keeps medical and IT loads running with no break until the generator starts. Medical locations, redundancy and sizing.](https://www.aecups.com/en/blog/ups-for-hospitals/)

## Talk to an AEC engineer

Tell us the load, the supply and the backup time you need for the AEC CPSS 10–200 kVA: we answer with the model and the batteries that fit. AEC International sells through distributors in about 80 countries and an agency in every Italian region: ask AEC which one serves your area.