---
title: "Dry contact card · Relay card for UPS alarms | AEC"
url: https://www.aecups.com/en/products/dry-contact-card/
description: "Dry contact card: relay card for UPS alarms. Potential-free contacts that signal UPS states, and remote shutdown."
language: en
---

UPS accessories · Communication cards and bypass

# Dry contact card

The relay or dry-contact card provides a set of potential-free, normally open or normally closed contacts that signal UPS functions. It also allows manual or automatic remote shutdown of the UPS.

Manuals and catalogues [Contact us](https://www.aecups.com/en/contacts/?msg=About%20the%20AEC%20Dry%20contact%20card%3A%20%0AQuantity%3A%20#form)

Overview

## Key facts

**Dry contacts**: on the card

**RS485**: on the card

**What it does**: Potential-free NO / NC contacts · Manual or automatic remote shutdown · Combined with RS485 on single-phase UPS

**AEC ranges**: IST3 · IST3-J · IST8 · All-in-One · IST9 · IST7 10–40 · IST7 60–200 · IST7-T · IST6-120 · IST6 200–500 · IST6 400–1200 · CPSS 1–10

#### **Full technical details** 4 sections of the EMEA 2026 catalogue: functions, panel, connections, diagrams and ordering codes

SIGNALS

## What the card reports

The dry-contact card shows the conditions that can occur in the UPS system:

- UPS in bypass mode
- No input mains
- UPS in inverter mode
- Batteries not suitable: check required
- Generic alarm: check required

SINGLE-PHASE UPS

## RS485 + dry-contact card: IST3, IST3-J, IST8

Three relay outputs plus RS485, fitted in the intelligent slot. Outputs are normally closed by default.

- Jumpers CN1–CN3: NC = jumper on pins 1–2 (default), NO = jumper on pins 2–3.
- Input signal below 60 V DC or 42 V AC RMS, below 1.25 A.
- Fitted in three steps from the rear: remove the standard slot, fit and fix the card, connect the communication cable.

**RS485 + dry-contact card: IST3, IST3-J, IST8**

| Pin | Signal |
| --- | --- |
| 1 · 2 | Mains abnormal: COM · NC/NO |
| 3 · 4 | Battery under-voltage: COM · NC/NO |
| 5 · 6 | UPS failure: COM · NC/NO |
| 7 · 8 | RS485-A · RS485-B |

COMPATIBILITY

## Dry-contact options across the range

Larger AEC UPS have dry contacts as standard and take an expansion card; the smaller ones use a card in the intelligent slot.

**Dry-contact options across the range**

| Series | How it is fitted | What it does |
| --- | --- | --- |
| IST3 · IST3-J · IST8 | intelligent slot: RS485 + dry-contact card | 3 outputs: mains abnormal, battery under-voltage, UPS failure · RS485 |
| IST9 | intelligent slot: RS485 + dry-contact card | 3 outputs (mains, battery, inverter or bypass) · 2 inputs (battery temperature, battery breaker or remote on / off) |
| IST7 10–40 kVA | intelligent slot: dry-contact kit | 3 outputs (mains, battery, inverter or bypass) · 2 inputs (battery temperature, battery breaker or remote ON / OFF) |
| All-in-One | RS485 + dry-contact card | dry contacts for the UPS |
| IST6 120 · 200–500 · 400–1200 kVA · IST7 60–200 kVA | dry-contact expansion card | +3 inputs, +2 outputs over the standard 4 inputs / 3 outputs (30 V DC / 2 A on IST6 200–1200 kVA) |

Compatibility

## Which AEC ranges take the Dry contact card?

From each range's communication section in the AEC UPS Catalogue EMEA 2026: standard, optional or in the intelligent slot.

| Range | Port or card | Supply | What it does |
| --- | --- | --- | --- |
| [IST3](https://www.aecups.com/en/products/ist3/) | RS485 | optional | RS485 and dry-contact card with 3 dry contacts, in the intelligent slot. |
| [IST3-J](https://www.aecups.com/en/products/ist3-j/) | RS485 | optional | RS485 and dry-contact card with 3 dry contacts, in the intelligent slot. |
| [IST8](https://www.aecups.com/en/products/ist8/) | Intelligent slot (DB9, RS232 + dry contact) | standard | DB9 port (RS232 + dry contact) as shipped. |
| [IST8](https://www.aecups.com/en/products/ist8/) | RS485 and dry-contact card | optional | Three relay outputs (mains abnormal, battery under-voltage, UPS failure) plus RS485, in the intelligent slot. |
| [All-in-One](https://www.aecups.com/en/products/all-in-one/) | Dry-contact card | optional | RS485 + dry-contact card for the UPS. |
| [IST9](https://www.aecups.com/en/products/ist9/) | Intelligent slot · RS485 + dry contact | optional | RS485 + dry-contact card: 3 outputs (mains, battery, inverter) and 2 inputs (battery temperature, battery breaker). |
| [IST7 10–40](https://www.aecups.com/en/products/ist7-10-40/) | Dry contacts | standard | Dry contact 2: EPO and IN.1 (1 input + EPO, 6 functions). |
| [IST7 10–40](https://www.aecups.com/en/products/ist7-10-40/) | Dry-contact kit | optional | 3 outputs: mains, battery, inverter (or bypass) status · 2 inputs: battery temperature, battery breaker (or remote ON/OFF). |
| [IST7 60–200](https://www.aecups.com/en/products/ist7-60-200/) | Dry contacts 4 IN / 3 OUT | standard | 4 inputs with 10 assignable functions and 3 changeover outputs (NO / NC) with 18 assignable functions, each set from the display. |
| [IST7 60–200](https://www.aecups.com/en/products/ist7-60-200/) | Dry contact expansion card | optional | +3 inputs (IN.5–IN.7) and +2 outputs (OUT.4–OUT.5). |
| [IST7-T](https://www.aecups.com/en/products/ist7-t/) | Dry contacts | standard | 8 output and 4 input dry contacts, configurable. |
| [IST6-120](https://www.aecups.com/en/products/ist6-120/) | Dry contacts 4 in / 3 out | standard | 4 inputs (NO), each assigned from the screen: battery abnormal, battery earth fault, battery switch disconnected, bypass switch disconnected, mains abnormal (generator start), input SPD abnormal. |
| [IST6-120](https://www.aecups.com/en/products/ist6-120/) | Dry contact expansion | optional | +3 inputs, +2 outputs (7 inputs + 5 outputs in total). |
| [IST6 200–500](https://www.aecups.com/en/products/ist6-200-500/) | Dry contacts 4 in / 3 out | standard | 4 inputs (NO) with 10 functions: battery abnormal, battery earthing abnormal, battery switch off, bypass switch off, generator mode, SPD abnormal, maintenance bypass open, mains switch off, environment smoke abnormal, lamp belt switch off. |
| [IST6 200–500](https://www.aecups.com/en/products/ist6-200-500/) | Dry contact expansion card | optional | +3 inputs, +2 outputs (30 V DC / 2 A). |
| [IST6 400–1200](https://www.aecups.com/en/products/ist6-400-1200/) | Dry contacts | standard | 4 inputs (NO) with 10 functions. |
| [IST6 400–1200](https://www.aecups.com/en/products/ist6-400-1200/) | Dry contact expansion card | optional | +3 inputs, +2 outputs (30 V DC / 2 A). |
| [CPSS 1–10](https://www.aecups.com/en/products/cpss-1-10/) | RS485 + dry contact | optional | RS485 and dry-contact card. |

### Ordering codes Dry contact card

| Code | Description |
| --- | --- |
| `DRYCNT-IST3/9` | Dry-contact relay board (IST3, IST9) |

In the same family: [SNMP card](https://www.aecups.com/en/products/snmp-card/) [USB card](https://www.aecups.com/en/products/usb-card/) [External maintenance bypass](https://www.aecups.com/en/products/maintenance-bypass/) [UPS accessories](https://www.aecups.com/en/products/ups-accessories/)

## Talk to an AEC engineer

Tell us the load, the supply and the backup time you need for the AEC Dry contact card: we answer with the model and the batteries that fit. AEC International sells through distributors in about 80 countries and an agency in every Italian region: ask AEC which one serves your area.

[Contact us](https://www.aecups.com/en/contacts/?msg=About%20the%20AEC%20Dry%20contact%20card%3A%20%0AQuantity%3A%20#form) [+39 02 9415 8991](tel:+390294158991)
