# IST3-J 6 kVA Online rack UPS 6 kVA, 2U, 230 V

VRLA 6 kVA online rack UPS, 2U, 230 V

The IST3-J 6 kVA is a 6 kVA / 6 kW single-phase online double-conversion UPS in a 2U chassis of 10.6 kg, a long backup model that runs on an external battery. For racks that need 5 kW of protected power and a backup time chosen by the number of battery cabinets.

**6 kVA / 6 kW** Rating

**438 × 500 × 86 mm** W × D × H

**10.6 kg** Weight

Technical data [Catalogue (PDF)](https://www.aecups.com/docs/AEC_UPS_Catalogue_EMEA_2026.pdf#page=23) [Contact us](https://www.aecups.com/en/contacts/?interest=Single-phase%20UPS&msg=About%20the%20AEC%20IST3-J%206%20kVA%20(IST3-J)%3A%20%0AQuantity%3A%20#form)

[**Try 3D** X-ray view](https://www.aecups.com/assets/models3d/ist3j-6/v68/)

Quick answers

## IST3-J 6 kVA: quick answers

**What it is**: The IST3-J 6 kVA is a 6 kVA / 6 kW single-phase online double-conversion UPS in a 2U chassis of 10.6 kg, a long backup model that runs on an external battery.

**Who it is for**: For racks that need 5 kW of protected power and a backup time chosen by the number of battery cabinets.

**Supply and configuration**: 208 / 220 / 230 / 240 V

**Battery and backup**: 192 V default (12–20 × 12 V settable) · external battery, any backup time

**Size and weight**: 438 × 500 × 86 mm · 10.6 kg

**Ordering code**: IST3J-6 · IST3J-6/10-\[n\]X9

IST3-J

## What sets apart the IST3-J 6 kVA

The 6 kVA has no internal batteries: its 192 V string (12 to 20 blocks of 12 V, set through communication) sits in BBJ2 rack cabinets of 3U, each with up to 16 × 12 V 9 Ah. The codes IST3J-6/10-\[n\]X9 go from one to eight BBJ2, 16 to 128 batteries. Input and output connect on a wire terminal; the two IEC C13 outlets take up to 10 A each.

Its input works at full load from 176 to 275 V and keeps going down to 80 V with linear derating. The overload table differs from the 1–3 kVA: 115–130% for 10 minutes, 130–150% for 30 seconds.

- **Against the IST3-J 3 kVA** (one size down): Power 6000 VA / 6000 W against 3000 VA / 3000 W; Voltage range 176–275 V full load · 80–176 V linear derating against 176–295 V > 75% load · 154–176 V 50–75% · 120–154 V < 50%; Voltage 220 V ± 2% default · 208 / 220 / 230 / 240 V against 208 / 220 / 230 / 240 V ± 1%, settable; Voltage distortion THD < 1% linear · < 4% non-linear against THD < 2% (linear load); Overload 115–130% 10 min · 130–150% 30 s · > 150% 500 ms against 105–110% 10 min · 110–130% 1 min · 130–150% 1 s · > 150% 200 ms.
- **Against the IST3-J 10 kVA** (one size up): Power 6000 VA / 6000 W against 10000 VA / 10000 W; Weight 10.6 kg against 12.2 kg.

Planning data

## IST3-J 6 kVA: currents, breakers, cables, batteries

The rows and columns of the EMEA 2026 catalogue's and AEC manuals' tables that concern the IST3-J 6 kVA.

### In the rack or on the floor

**IST3-J 6 kVA · In the rack or on the floor**

| Model | 6 kVA |
| --- | --- |
| AC input max. (A) | 36 |
| AC breaker (A) | 50 |
| DC input max. (A) | 39 |
| DC breaker (A) | 50 |
| AC cable (mm²) | — |
| DC cable (mm²) | — |

Installation

## Installing the IST3-J 6 kVA: space, cables

Each figure with its source.

**IST3-J 6 kVA · installation**

| Item | Figure | Source |
| --- | --- | --- |
| Clearances | rear 300 mm (recommended 500), left 300 mm (recommended 500), right 300 mm (recommended 500); front and top: not given | AEC IST3-J 6–10 user manual p.6 §1.3 |
| Cable entry | Rear terminal block | AEC IST3-J 6–10 user manual |
| Operating temperature | −5 to 40 °C, best 20–25 °C | AEC IST3-J 6–10 user manual p.6 §1.3 |
| Switches and terminals | Input breaker, terminal block and the battery port on the rear panel. | AEC IST3-J 6–10 user manual p.6 §1.3 |

Size and floor

## How big it is

438 × 500 × 86 mm · 10.6 kg.

**0.22 m²** footprint

**48 kg/m²** floor load

**0.09 m** height

Floor load = weight ÷ footprint (10.6 kg).

Efficiency

## How efficient is the AEC IST3-J 6 kVA at your load?

IST3-J 6 kVA, 6 kW at its rating, online, double conversion (typical curve, AEC's method). Heat to remove on this curve: 50%: 0.19 kW (η 94.05%) · 75%: 0.21 kW (η 95.5%) · 100%: 0.30 kW (η 95.3%). At 50% load, 24/7, it loses about 1,663 kWh a year.

**95.5** % 75% · Typical curve, derived from the datasheet efficiency of 95.5% (AEC method)

How the curve is drawn and where each figure comes from: [the IST3-J range page](https://www.aecups.com/en/products/ist3-j/#efficiency).

**Load**: —

**Lost as heat**: —

**Energy lost in a year, 24/7**: —

**Its cost in a year at € per kWh**: —

The catalogue's examples use €0.20 per kWh.

#### Where each figure comes from

| Mode | Efficiency | Kind | Models | Source |
| --- | --- | --- | --- | --- |
| Online, double conversion | 30%: 93.04% · 50%: 94.05% · 75%: 95.5% · 100%: 95.3% | Typical curve, derived from the datasheet efficiency of 95.5% (AEC method) | IST3-J 6 kVA · IST3-J 10 kVA | AEC technical datasheet IST3-J 1–3 kVA: AC/AC efficiency |
| ECO | 98.3% | Datasheet figure, load not stated | all | AEC technical datasheet IST3-J 1–3 kVA: AC/AC efficiency |
| Online, double conversion | 30%: 86.14% · 50%: 88.7% · 75%: 90.06% · 100%: 90.83% | Measured (AEC datasheet) | IST3-J 1 kVA | AEC technical datasheet IST3-J 1–3 kVA: AC/AC efficiency |
| Online, double conversion | 30%: 89.36% · 50%: 91.23% · 75%: 92.16% · 100%: 92.56% | Measured (AEC datasheet) | IST3-J 2 kVA | AEC technical datasheet IST3-J 1–3 kVA: AC/AC efficiency |
| Online, double conversion | 30%: 90.84% · 50%: 91.85% · 75%: 93.3% · 100%: 93.1% | Measured (AEC datasheet) | IST3-J 3 kVA | AEC technical datasheet IST3-J 1–3 kVA: AC/AC efficiency |

EMEA 2026 catalogue figures: Online, double conversion up to 95.5%.

Drag to turn

In 3D

## Look around the IST3-J 6 kVA

[Open full 3D · X-ray](https://www.aecups.com/assets/models3d/ist3j-6/v68/)

Technical data

## Technical data IST3-J 6 kVA

Only this model's values, from the EMEA 2026 catalogue table.

**IST3-J 6 kVA · Technical data**

|  |  |
| --- | --- |
| Rating |  |
| Power (VA / W) | 6000 / 6000 |
| Efficiency (AC/AC) | up to 95.5% · 98.3% in ECO mode |
| Input |  |
| Voltage range | 176–275 V full load · 80–176 V linear derating |
| Frequency · connection | 50 / 60 Hz ± 10%, self-adapting · single phase, L + N + PE, TN system |
| Output |  |
| Voltage | 220 V ± 2% default · 208 / 220 / 230 / 240 V |
| Frequency · waveform · transfer | 50 / 60 Hz ± 0.2% in battery mode · sine wave · 0 ms |
| Voltage distortion | THD < 1% linear · < 4% non-linear |
| Power factor | 1.0 (kVA = kW) |
| Overload | 115–130% 10 min · 130–150% 30 s · > 150% 500 ms |
| Output outlets | 2 × IEC C13 (each ≤ 10 A) + wire terminal |
| Battery |  |
| Battery voltage | 192 V default (12–20 × 12 V settable) |
| Backup · recharge | external battery, any backup time |
| General |  |
| Communication | RS232 · intelligent slot options |
| Protections | battery under-voltage, overload, short circuit, over-temperature, input overvoltage |
| Noise | < 55 dB |
| Environment | −5 … 40 °C · 0–95% RH · < 1000 m (derate above) |
| Dimensions W × D × H (mm) | 438 × 500 × 86 |
| Weight (kg) | 10.6 |

6 kVA: long backup model only (L). Specifications are subject to change without notice.

#### **More technical details** ordering codes

Ordering codes

## Ordering codes IST3-J 6 kVA

**Ordering codes IST3-J 6 kVA**

| Code | Description |
| --- | --- |
| IST3J-\[kVA\]-\[n\]X9 | 1–3 kVA with internal batteries plus BBJ / BBJ2 rack cabinets, n × 12 V 9 Ah in total |
| IST3J-6 · IST3J-10 | 6 / 10 kVA, external batteries only |
| IST3J-6/10-\[n\]X9 | 6 / 10 kVA with 1 to 8 BBJ2 cabinets, 16 to 128 × 12 V 9 Ah |
| BBJ · BBJ2 | Rack battery cabinet, max. 8 × 12 V 9 Ah (2U) · max. 16 × 12 V 9 Ah (3U) |

Questions

## Questions about the IST3-J 6 kVA

#### Does the IST3-J 6 kVA have internal batteries?

No. It is a long backup model (L): the battery is external, 192 V by default, in one to eight BBJ2 rack cabinets of 16 × 12 V 9 Ah each. The backup time is set by the battery you choose.

#### What breaker does the IST3-J 6 kVA need?

The catalogue recommends a 50 A upstream input breaker (36 A maximum input current) and a 50 A DC breaker for the battery, which draws up to 39 A. Size the cables on these currents.

#### How long does a 6 kVA UPS like the IST3-J 6 kVA run?

4 to 86 minutes at full load (6 kW), and 13 to 218 minutes at half load, with the AEC battery options in the table: the battery chosen sets the figure. With 16 × 12 V 9 Ah (IST3J-6-16X9): 4 minutes at 100% and 13 at 50%. For other loads and batteries use the backup-time tool.

#### How big is the AEC IST3-J 6 kVA and how much does it weigh?

The AEC IST3-J 6 kVA measures 438 × 500 × 86 mm; weight: 10.6 kg (EMEA 2026 catalogue).

#### What is the ordering code of the AEC IST3-J 6 kVA?

In the EMEA 2026 catalogue the AEC IST3-J 6 kVA is listed as IST3J-6, IST3J-6/10-\[n\]X9; AEC gives the full code, batteries included, from the load and the backup time.

Related models

## The same range: IST3-J

[The whole range](https://www.aecups.com/en/products/ist3-j/)

[**IST3-J 1 kVA** 1 kVA](https://www.aecups.com/en/products/ist3-j/ist3j-1k/) [**IST3-J 2 kVA** 2 kVA](https://www.aecups.com/en/products/ist3-j/ist3j-2k/) [**IST3-J 3 kVA** 3 kVA · smaller rating](https://www.aecups.com/en/products/ist3-j/ist3j-3k/) **IST3-J 6 kVA** 6 kVA [**IST3-J 10 kVA** 10 kVA · larger rating](https://www.aecups.com/en/products/ist3-j/ist3j-10k/)

Batteries and cabinets: [BBJ2](https://www.aecups.com/en/products/battery-cabinets/bbj2/) [OZ Power 12 V 9 Ah](https://www.aecups.com/en/products/oz-power-vrla/oz-12v-9ah/) Accessories: [SNMP card](https://www.aecups.com/en/products/snmp-card/) [Dry contact card](https://www.aecups.com/en/products/dry-contact-card/)

Shared by the whole range, on the IST3-J page: [the display simulator](https://www.aecups.com/en/products/ist3-j/#display) · [how the power flows in each mode](https://www.aecups.com/en/products/ist3-j/#diagrams) · [the catalogue's photos and drawings](https://www.aecups.com/en/products/ist3-j/#gallery).

Read next: [UPS for CCTV and video surveillance systems](https://www.aecups.com/en/blog/ups-for-cctv/) [UPS for home: protect devices, router and data](https://www.aecups.com/en/blog/ups-for-home/)

## Talk to an AEC engineer

Tell us the load, the supply and the backup time you need for the AEC IST3-J 6 kVA: we answer with the model and the batteries that fit. AEC International sells through distributors in about 80 countries and an agency in every Italian region: ask AEC which one serves your area.

[Contact us](https://www.aecups.com/en/contacts/?interest=Single-phase%20UPS&msg=About%20the%20AEC%20IST3-J%206%20kVA%20(IST3-J)%3A%20%0AQuantity%3A%20#form) [+39 02 9415 8991](tel:+390294158991)