# IST3-1 Single-phase online UPS 1 kVA, tower, 230 V

VRLA 1 kVA online tower UPS, 230 V

The IST3-1 is a 1 kVA / 1000 W single-phase online double-conversion tower UPS with two internal 12 V 9 Ah batteries. For a workstation, a small server, a switch or a till: it plugs into a wall socket and feeds the loads from two Schuko outlets.

**1 kVA / 1 kW** Rating

**145 × 357 × 226 mm** W × D × H

**8.5 / 4.6 kg** Weight

**24 V** Battery

Technical data [Catalogue (PDF)](https://www.aecups.com/docs/AEC_UPS_Catalogue_EMEA_2026.pdf#page=13) [Contact us](https://www.aecups.com/en/contacts/?interest=Single-phase%20UPS&msg=About%20the%20AEC%20IST3-1%20(IST3)%3A%20%0AQuantity%3A%20#form)

[**Try 3D** X-ray view](https://www.aecups.com/assets/models3d/ist3-1/v71/)

Quick answers

## IST3-1: quick answers

**What it is**: The IST3-1 is a 1 kVA / 1000 W single-phase online double-conversion tower UPS with two internal 12 V 9 Ah batteries.

**Who it is for**: For a workstation, a small server, a switch or a till: it plugs into a wall socket and feeds the loads from two Schuko outlets.

**Supply and configuration**: 208 / 220 / 230 / 240 V

**Battery and backup**: 24 V · 3 min at full load

**Size and weight**: 145 × 357 × 226 mm · 8.5 / 4.6 kg

**Ordering code**: IST3-1-2X9 · IST3-1-L

IST3

## What sets apart the IST3-1

The IST3-1 is the smallest AEC online UPS: 145 × 357 × 226 mm and 8.5 kg, so it sits under a desk or on a shelf. Its two 9 Ah blocks make a 24 V battery that gives 2 minutes at full load and 8 at half load in AEC's data (the catalogue prints 3 minutes), enough to ride through short outages and close files on a long one. The long backup version (IST3-1-L, 4.6 kg) has no internal batteries and runs on a 36 V external string instead.

Like the 2 and 3 kVA models it runs from the mains, not the battery, through brownouts: full load from 176 to 295 V, and down to 120 V when the load is below 50%. The battery is saved for real outages. Mains comes in through an IEC socket with a fuse; the rear also has USB, RS232, the EPO connector and the intelligent slot for an SNMP or RS485 / dry-contact card.

- **Against the IST3-2** (one size up): Power 1000 VA / 1000 W against 2000 VA / 2000 W; Voltage, standard model 24 V against 48 V; Voltage, long backup model 36 V against 72 V; Dimensions W × D × H, standard 145 × 357 × 226 against 190 × 397 × 330; Dimensions W × D × H, long backup 145 × 357 × 226 against 190 × 397 × 330.

Planning data

## IST3-1: currents, breakers, cables, batteries

The rows and columns of the EMEA 2026 catalogue's and AEC manuals' tables that concern the IST3-1.

### Wall socket or terminal bar

**IST3-1 · Wall socket or terminal bar**

| Model | 1 kVA |
| --- | --- |
| AC input max. (A) | 6 |
| AC breaker (A) | 10 |
| DC input max. (A, long backup) | 37 |
| DC breaker (A) | 50 |
| AC cable (mm²) | 1.5 |
| Battery cable (mm²) | 6 |

Installation

## Installing the IST3-1: space, cables

Each figure with its source.

**IST3-1 · installation**

| Item | Figure | Source |
| --- | --- | --- |
| Clearances | rear 300 mm (recommended 500), left 300 mm (recommended 500), right 300 mm (recommended 500); front and top: not given | AEC IST3 user manual p.6 §1.2 |
| Cable entry | Plugs and sockets at the rear | AEC IST3 user manual |
| Operating temperature | −5 to 40 °C, best 20–25 °C | AEC IST3 user manual p.6 §1.2 |
| Switches and terminals | Sockets, over-current protector and the battery connector on the rear panel. | AEC IST3 user manual p.6 §1.2 |

Size and floor

## How big it is

145 × 357 × 226 mm · 8.5 / 4.6 kg.

**0.05 m²** footprint

**89–164 kg/m²** floor load

**0.23 m** height

Floor load = weight ÷ footprint: 89 kg/m² at the lowest weight given (4.6 kg), 164 kg/m² at the highest (8.5 kg).

Efficiency

## How efficient is the AEC IST3-1 at your load?

IST3-1, 1 kW at its rating, online, double conversion (AEC's measured curve). Heat to remove on this curve: 50%: 0.06 kW (η 88.7%) · 75%: 0.08 kW (η 90.06%) · 100%: 0.10 kW (η 90.83%). At 50% load, 24/7, it loses about 558 kWh a year.

**90.83** % 100% · Measured (AEC datasheet)

How the curve is drawn and where each figure comes from: [the IST3 range page](https://www.aecups.com/en/products/ist3/#efficiency). The IST3 pages of the EMEA 2026 catalogue give no efficiency figure. The 1, 2 and 3 kVA curves are the ones AEC measured on the IST3-J of the same rating (AEC technical datasheet IST3-J 1–3 kVA), which AEC states has the same electronics; the 6 and 10 kVA curve has the same shape, moved to their 95.5% figure.

**Load**: —

**Lost as heat**: —

**Energy lost in a year, 24/7**: —

**Its cost in a year at € per kWh**: —

The catalogue's examples use €0.20 per kWh.

#### Where each figure comes from

| Mode | Efficiency | Kind | Models | Source |
| --- | --- | --- | --- | --- |
| Online, double conversion | 30%: 86.14% · 50%: 88.7% · 75%: 90.06% · 100%: 90.83% | Measured (AEC datasheet) | IST3-1 | AEC technical datasheet IST3-J 1–3 kVA: AC/AC efficiency |
| ECO | 98.3% | Datasheet figure, load not stated | all | AEC technical datasheet IST3-J 1–3 kVA: AC/AC efficiency |
| Online, double conversion | 30%: 89.36% · 50%: 91.23% · 75%: 92.16% · 100%: 92.56% | Measured (AEC datasheet) | IST3-2 | AEC technical datasheet IST3-J 1–3 kVA: AC/AC efficiency |
| Online, double conversion | 30%: 90.84% · 50%: 91.85% · 75%: 93.3% · 100%: 93.1% | Measured (AEC datasheet) | IST3-3 | AEC technical datasheet IST3-J 1–3 kVA: AC/AC efficiency |
| Online, double conversion | 30%: 93.04% · 50%: 94.05% · 75%: 95.5% · 100%: 95.3% | Typical curve, derived from the datasheet efficiency of 95.5% (AEC method) | IST3-6 · IST3-10 | AEC technical datasheet IST3-J 1–3 kVA: AC/AC efficiency |

Drag to turn

In 3D

## Look around the IST3-1

[Open full 3D · X-ray](https://www.aecups.com/assets/models3d/ist3-1/v71/)

Technical data

## Technical data IST3-1

Only this model's values, from the EMEA 2026 catalogue table.

**IST3-1 · Technical data**

|  |  |
| --- | --- |
| Rating |  |
| Power (VA / W) | 1000 / 1000 |
| Efficiency (AC/AC) | up to 90.8% · 98.3% in ECO mode |
| Input |  |
| Voltage range | 176–295 V full load · 154–176 V load < 75% · 120–154 V load < 50% |
| Frequency · connection | 50 / 60 Hz ± 10%, self-adapting · single phase, L + N + PE |
| Output |  |
| Voltage | 220 V ± 2% (default) · 208 / 220 / 230 / 240 V settable from the panel |
| Frequency · waveform | 50 / 60 Hz ± 0.2% in battery mode · sine wave |
| Voltage distortion | THD < 3% (linear load) |
| Power factor · transfer time | 1.0 (kVA = kW) · 0 ms mains to battery |
| Overload | 100–130% 1 min · 130–150% 1 s · > 150% 200 ms |
| Battery |  |
| Voltage, standard model | 24 V |
| Voltage, long backup model | 36 V |
| Backup time, standard model | 3 min at full load |
| Charge recovery | standard model < 10 h · long backup: depends on the battery pack |
| General |  |
| Communication | RS232 and USB standard · SNMP card or RS485 and dry-contact card optional · EPO |
| Protections | battery undervoltage, overload, short circuit, over-temperature, input overvoltage |
| Noise | < 50 dB |
| Environment | −5 … 40 °C · 0–95% RH non-condensing · ≤ 1000 m without derating |
| Dimensions W × D × H, standard | 145 × 357 × 226 |
| Dimensions W × D × H, long backup | 145 × 357 × 226 |
| Weight standard / long backup (kg) | 8.5 / 4.6 |

**IST3-1 · Models**

| Item | IST3-1 |
| --- | --- |
| VA / W | 1000 / 1000 |
| Internal batteries | 2 × 9 Ah · 24 V |
| Backup, full / half load | 3 min |
| W × D × H (mm) | 145 × 357 × 226 |
| kg | 8.5 |
| Long backup: battery | 36 V |
| Long backup: kg | 4.6 |

Specifications are subject to change without notice.

#### **More technical details** ordering codes

Ordering codes

## Ordering codes IST3-1

**Ordering codes IST3-1**

| Code | Description |
| --- | --- |
| IST3-1-2X9 · IST3-2-4X9 · IST3-3-6X9 | Standard models with internal 12 V 9 Ah batteries (2, 4, 6) |
| IST3-1-L · IST3-2-L · IST3-3-L | Long backup, external batteries only (36 / 72 / 96 V) |
| IST3-\[kVA\]-\[n\]X9 | UPS with battery cabinet BB1, BB2 or BB3, n × 12 V 9 Ah in total |
| DRYCNT-IST3/9 · SNMP | Dry-contact relay board · internal SNMP board |
| MBYP-3K · MBYP-6K | External manual maintenance bypass, rack, max. 3 kVA · max. 10 kVA |

Questions

## Questions about the IST3-1

#### How long does the IST3-1 run on battery?

2 minutes at full load (1000 W) and 8 at half load with its two internal 12 V 9 Ah batteries, in AEC's data (the catalogue prints 3 minutes). For longer backup, a BB1 tower cabinet takes up to 6 × 12 V 9 Ah (code IST3-1-6X9), or the long backup model IST3-1-L runs on an external 36 V battery.

#### What breaker does the IST3-1 need upstream?

The catalogue gives 6 A maximum AC input current and a 10 A breaker, without leakage protection, on a 1.5 mm² cable for about 5 m. The long backup model draws up to 37 A from its battery, on a 50 A DC breaker and 6 mm² cable.

#### How long does a 1 kVA UPS like the IST3-1 run?

2 to 41 minutes at full load (1 kW), and 8 to 101 minutes at half load, with the AEC battery options in the table: the battery chosen sets the figure. With 2 × 12 V 9 Ah (IST3-1-2X9): 2 minutes at 100% and 8 at 50%. For other loads and batteries use the backup-time tool.

#### How big is the AEC IST3-1 and how much does it weigh?

The AEC IST3-1 measures 145 × 357 × 226 mm; weight: 8.5 / 4.6 kg (size from AEC's CAD drawing, weight from the EMEA 2026 catalogue).

#### What is the ordering code of the AEC IST3-1?

In the EMEA 2026 catalogue the AEC IST3-1 is listed as IST3-1-2X9, IST3-1-L; AEC gives the full code, batteries included, from the load and the backup time.

Related models

## The same range: IST3

[The whole range](https://www.aecups.com/en/products/ist3/)

**IST3-1** 1 kVA [**IST3-2** 2 kVA · larger rating](https://www.aecups.com/en/products/ist3/ist3-2k/) [**IST3-3** 3 kVA](https://www.aecups.com/en/products/ist3/ist3-3k/) [**IST3-6** 6 kVA](https://www.aecups.com/en/products/ist3/ist3-6k/) [**IST3-10** 10 kVA](https://www.aecups.com/en/products/ist3/ist3-10k/)

Batteries and cabinets: [BB1](https://www.aecups.com/en/products/battery-cabinets/bb1/) [OZ Power 12 V 9 Ah](https://www.aecups.com/en/products/oz-power-vrla/oz-12v-9ah/) Accessories: [SNMP card](https://www.aecups.com/en/products/snmp-card/) [Dry contact card](https://www.aecups.com/en/products/dry-contact-card/) [External maintenance bypass](https://www.aecups.com/en/products/maintenance-bypass/)

Shared by the whole range, on the IST3 page: [the display simulator](https://www.aecups.com/en/products/ist3/#display) · [how the power flows in each mode](https://www.aecups.com/en/products/ist3/#diagrams) · [the catalogue's photos and drawings](https://www.aecups.com/en/products/ist3/#gallery).

Read next: [How to choose a UPS: type, runtime, phases and service](https://www.aecups.com/en/blog/how-to-choose-a-ups/) [Single- or three-phase UPS: which does your site need?](https://www.aecups.com/en/blog/single-vs-three-phase-ups/) [UPS sizing: how to work out the power you need](https://www.aecups.com/en/blog/ups-sizing/)

## Talk to an AEC engineer

Tell us the load, the supply and the backup time you need for the AEC IST3-1: we answer with the model and the batteries that fit. AEC International sells through distributors in about 80 countries and an agency in every Italian region: ask AEC which one serves your area.

[Contact us](https://www.aecups.com/en/contacts/?interest=Single-phase%20UPS&msg=About%20the%20AEC%20IST3-1%20(IST3)%3A%20%0AQuantity%3A%20#form) [+39 02 9415 8991](tel:+390294158991)