# IST6-120, 2 × 30 kVA Modular UPS, 30 kVA modules

VRLA 60 kVA modular online UPS, 30 kVA modules

The IST6-120 with two 30 kVA power modules is a 60 kVA / 60 kW modular online UPS in a 0.52 m² cabinet, with room for two more modules and a redundancy slot. For server rooms and telecom or banking sites of 30 to 60 kW that want hot-swap modules and room to grow.

**60 kVA / 60 kW** Rating

**600 × 860 × 2000 mm** W × D × H

**195 kg + 2 × 24 kg modules** Weight

Technical data [Catalogue (PDF)](https://www.aecups.com/docs/AEC_UPS_Catalogue_EMEA_2026.pdf#page=108) [Contact us](https://www.aecups.com/en/contacts/?interest=Modular%20UPS&msg=About%20the%20AEC%20IST6-120%2C%202%20%C3%97%2030%20kVA%20(IST6-120)%3A%20%0AQuantity%3A%20#form)

[**Try 3D** X-ray view](https://www.aecups.com/assets/models3d/ist6-60/v66/)

Quick answers

## IST6-120, 2 × 30 kVA: quick answers

**What it is**: The IST6-120 with two 30 kVA power modules is a 60 kVA / 60 kW modular online UPS in a 0.52 m² cabinet, with room for two more modules and a redundancy slot.

**Who it is for**: For server rooms and telecom or banking sites of 30 to 60 kW that want hot-swap modules and room to grow.

**Supply and configuration**: 3 ph + N + PE · 220 / 230 / 240 V L-N · 220 / 230 / 240 V L-N · 380 / 400 / 415 V L-L

**Size and weight**: 600 × 860 × 2000 mm · 195 kg + 2 × 24 kg modules

**Ordering code**: IST6-120 + 2 × IST6-30-J (3 × for N+1)

IST6-120

## What sets apart the IST6-120, 2 × 30 kVA

Two modules share a 60 kVA load equally, under digital control with no master and no slave. Add a third for N+1: with 60 kVA of load and three modules, any one of them can fail or be pulled out for service and the load stays on the inverter. The charger gives up to 20 A with two modules.

At light load, the redundancy sleep function (Smart mode › Sleep redundancy) lets spare modules rest within a sleep safety load set on the screen, with an alarm if the load goes above it. The cabinet is the same as at 120 kVA, so cables and switchgear are sized once.

Planning data

## IST6-120, 2 × 30 kVA: currents, breakers, cables, batteries

The rows and columns of the EMEA 2026 catalogue's and AEC manuals' tables that concern the IST6-120, 2 × 30 kVA.

### Power added one 30 kVA module at a time

**IST6-120, 2 × 30 kVA · Power added one 30 kVA module at a time**

| Load up to | Modules (N) | Modules for N+1 |
| --- | --- | --- |
| 60 kVA | 2 | 3 |

Installation

## Installing the IST6-120, 2 × 30 kVA: space, heat, cables

Each figure with its source. Heat is the power lost at the peak efficiency stated.

**IST6-120, 2 × 30 kVA · installation**

| Item | Figure | Source |
| --- | --- | --- |
| Clearances | front 800 mm, rear 800 mm, top 500 mm; left and right: not given | IST6 user manual Fig. 3-2 p.44 |
| Cable entry | Bottom (standard); Top, with the top wiring accessory (cables up to 120 mm²) | IST6 user manual Fig. 3-2 p.44 |
| Heat at full load | 1.86 kW at 60 kW load, 97 % efficiency | EMEA 2026 catalogue p.109, 122; output PF 1 (EMEA 2026 catalogue) |
| Operating temperature | −5 to 40 °C | IST6 30–120 user manual |
| Switches and terminals | Mains, SPD and output switches (796 mm up) and bypass and maintenance bypass (549 mm up) inside the front door. | IST6 user manual Fig. 2-3 p.13, Fig. 3-2 p.44 |
| Door | One leaf, hinged on the right | IST6 user manual Fig. 2-3 p.13, Fig. 3-2 p.44 |
| Module withdrawal | 700 mm in front of the cabinet to withdraw a module | IST6 user manual Fig. 2-6 p.15; EMEA 2026 catalogue p.125–126 |

Size and floor

## How big it is

600 × 860 × 2000 mm · 195 kg + 2 × 24 kg modules.

**0.52 m²** footprint

**471 kg/m²** floor load

**2 m** height

Floor load = weight ÷ footprint: cabinet and modules, 195 + 2 × 24 = 243 kg.

Efficiency

## How efficient is the AEC IST6-120, 2 × 30 kVA at your load?

IST6-120, 2 × 30 kVA, 60 kW at its rating, online, double conversion (typical curve, AEC's method). Heat to remove on this curve: 25%: 0.56 kW (η 96.4%) · 50%: 0.93 kW (η 97%) · 75%: 1.54 kW (η 96.7%) · 100%: 2.24 kW (η 96.4%). At 50% load, 24/7, it loses about 8,128 kWh a year.

**97** % 50% · Typical curve, derived from the datasheet efficiency of 97% (AEC method)

How the curve is drawn and where each figure comes from: [the IST6-120 range page](https://www.aecups.com/en/products/ist6-120/#efficiency).

**Load**: —

**Lost as heat**: —

**Energy lost in a year, 24/7**: —

**Its cost in a year at € per kWh**: —

The catalogue's examples use €0.20 per kWh.

#### Where each figure comes from

| Mode | Efficiency | Kind | Models | Source |
| --- | --- | --- | --- | --- |
| Online, double conversion | 25%: 96.4% · 50%: 97% · 75%: 96.7% · 100%: 96.4% | Typical curve, derived from the datasheet efficiency of 97% (AEC method) | all | AEC datasheet: AC/AC efficiency of the IST6-PM100 100 kW power module (the curve's shape) |
| ECO | 99% | Datasheet figure, load not stated | all |  |

EMEA 2026 catalogue figures: Online, double conversion up to 97% · ECO up to 99%.

Drag to turn

In 3D

## Look around the IST6-120, 2 × 30 kVA

[Open full 3D · X-ray](https://www.aecups.com/assets/models3d/ist6-60/v66/)

The turntable shows the IST6 120 kVA; the full 3D view opens on the IST6 60 kVA.

Technical data

## Technical data IST6-120, 2 × 30 kVA

Only this model's values, from the EMEA 2026 catalogue table.

**IST6-120, 2 × 30 kVA · Technical data**

|  |  |
| --- | --- |
| General |  |
| Model | IST6-120 with IST6-30-J power modules |
| Rated power | 30 to 120 kVA / kW in 30 kVA steps (1–4 modules) + 1 redundancy slot |
| Topology | online double conversion, modular, hot-swap power modules, removable bypass module |
| Input |  |
| Connection · voltage | 3 ph + N + PE · 220 / 230 / 240 V L-N |
| Voltage range | 176–280 V full power · 80–176 V derated (linear load) |
| Frequency · power factor · THDi | 40–70 Hz · ≥ 0.99 · ≤ 2% resistive, ≤ 3% non-linear full load |
| Bypass | 220 / 230 / 240 V L-N; synchronisation 50 / 60 Hz ± 6 Hz |
| Battery |  |
| Voltage · blocks | ±168 … ±276 V DC · ±14 … ±23 × 12 V (default ±16; below ±16 load 80%) |
| Charging current | 10 A × number of modules (max.) |
| Functions | cold start · standard / deep test · common battery · lithium with BMS card |
| Output |  |
| Connection · voltage | 3 ph + N + PE · 220 / 230 / 240 V L-N, 380 / 400 / 415 V L-L |
| Power factor · THDv | 1 · ≤ 1% linear, ≤ 4% non-linear |
| Frequency · phase error | tracks the bypass; 50 / 60 Hz ± 0.2% without mains · ≤ 1° (balanced load) |
| Transfer · dynamic response | 0 ms synchronised, < 15 ms not synchronised · < 5% for 0↔100% step |
| Inverter overload (PF 1) | ≤ 105% continuous · 106–110% 60 min · 111–125% 10 min · 126–150% 1 min · > 151% to bypass |
| Bypass overload | < 130% continuous · 131–150% 5 min · 151–200% 1 s · 201–300% 100 ms |
| Unbalanced load | 100% |
| System |  |
| Efficiency | 97% double conversion · up to 99% ECO |
| Display · records | 7" colour touch screen · 10,000 events · 5 LEDs · status light bar |
| Communication | Modbus · RS232 · RS485 · 4 dry-contact inputs, 3 outputs · options: SNMP, dry-contact expansion, BMS card |
| Parallel | with parallel kit, ring cables; BSC dual bus |
| Environment | −5 … 40 °C · 0–95% RH · ≤ 2000 m · IP20 · < 65 dB · EMC class C3 |
| Dimensions W × D × H | 600 × 860 × 2000 mm · cable entry bottom (top with accessory) |
| Weight | cabinet without power modules 195 kg · power module 24 kg · bypass module 17 kg |

**IST6-120, 2 × 30 kVA · Models**

| Item | IST6-120, 2 × 30 kVA |
| --- | --- |
| Modules (N) | 2 |
| Modules for N+1 | 3 |

Specifications are subject to change without notice.

#### **More technical details** how it works, ordering codes

Diagrams

## How the power flows: AEC IST6-120, 2 × 30 kVA

Pick an operating mode: the path the power takes to the load lights up.

**Normal.** Double conversion: the rectifier feeds the DC bus, the inverter rebuilds a clean voltage and the load always runs on the inverter. The battery stays on charge. Efficiency up to 97%.

### Modules and redundancy

Move the slider: the modules the load needs light up, and the spare slot holds the N+1 redundancy. Each slot takes one 30 kVA module.

modules working · redundant · free slot

Ordering codes

## Ordering codes IST6-120, 2 × 30 kVA

**Ordering codes IST6-120, 2 × 30 kVA**

| Code | Description |
| --- | --- |
| IST6-120 | Modular cabinet, max. 4 × 30 kVA power modules, supplied without modules |
| IST6-30-J | 30 kVA / 30 kW power module |
| PAR - IST6 | Parallel kit |

Questions

## Questions about the IST6-120, 2 × 30 kVA

#### How many modules for 60 kVA with redundancy?

Three: two carry the load (N = 2) and the third is the redundant one (N+1), as in the catalogue's table. Each module is 30 kVA / 30 kW, 2U and 24 kg.

#### Can a module be replaced with the load on?

Yes. Each module has a ready switch and RUN / ALARM / FAULT LEDs; a faulty module is isolated automatically and replaced online. Wait at least 10 minutes after removal before opening it; replacement by AEC or authorised personnel.

#### How big is the AEC IST6-120, 2 × 30 kVA and how much does it weigh?

The AEC IST6-120, 2 × 30 kVA measures 600 × 860 × 2000 mm; weight: 195 kg + 2 × 24 kg modules (EMEA 2026 catalogue).

Related models

## The same range: IST6-120

[The whole range](https://www.aecups.com/en/products/ist6-120/)

[**IST6-120, 1 × 30 kVA** 30 kVA · smaller rating](https://www.aecups.com/en/products/ist6-120/ist6-30k-1x30/) **IST6-120, 2 × 30 kVA** 60 kVA [**IST6-120, 3 × 30 kVA** 90 kVA · larger rating](https://www.aecups.com/en/products/ist6-120/ist6-90k-3x30/) [**IST6-120, 4 × 30 kVA** 120 kVA](https://www.aecups.com/en/products/ist6-120/ist6-120k-4x30/)

Batteries and cabinets: [L6 Lithium](https://www.aecups.com/en/products/l6-lithium/) Accessories: [SNMP card](https://www.aecups.com/en/products/snmp-card/) [Dry contact card](https://www.aecups.com/en/products/dry-contact-card/)

Shared by the whole range, on the IST6-120 page: [the display simulator](https://www.aecups.com/en/products/ist6-120/#display) · [the catalogue's photos and drawings](https://www.aecups.com/en/products/ist6-120/#gallery).

Read next: [Modular UPS: how to grow power module by module](https://www.aecups.com/en/blog/modular-ups/) [UPS redundancy: N+1 or 2N, and how much a site needs](https://www.aecups.com/en/blog/ups-redundancy-n-plus-1/) [UPS for data centres: how to choose and plan](https://www.aecups.com/en/blog/ups-for-data-centres/)

## Talk to an AEC engineer

Tell us the load, the supply and the backup time you need for the AEC IST6-120, 2 × 30 kVA: we answer with the model and the batteries that fit. AEC International sells through distributors in about 80 countries and an agency in every Italian region: ask AEC which one serves your area.

[Contact us](https://www.aecups.com/en/contacts/?interest=Modular%20UPS&msg=About%20the%20AEC%20IST6-120%2C%202%20%C3%97%2030%20kVA%20(IST6-120)%3A%20%0AQuantity%3A%20#form) [+39 02 9415 8991](tel:+390294158991)