# IST6-500, 10 × 50 kVA Hot-swappable modular UPS, 400 V

VRLA 500 kVA modular online UPS, 50 kVA modules

The IST6 500 kVA is the largest cabinet of the 50 kVA platform: ten 50 kVA power modules and a 4.5U bypass module in a 1203 × 864 × 2000 mm double column. For large data centres and buildings with 400 to 500 kW per UPS, or up to eight UPS in parallel and multi-bus systems.

**500 kVA / 500 kW** Rating

**1203 × 864 × 2000 mm** W × D × H

**506 kg without modules** Weight

Technical data [Catalogue (PDF)](https://www.aecups.com/docs/AEC_UPS_Catalogue_EMEA_2026.pdf#page=123) [Contact us](https://www.aecups.com/en/contacts/?interest=Modular%20UPS&msg=About%20the%20AEC%20IST6-500%2C%2010%20%C3%97%2050%20kVA%20(IST6%20200%E2%80%93500)%3A%20%0AQuantity%3A%20#form)

[**Try 3D** X-ray view](https://www.aecups.com/assets/models3d/ist6-50m-500/v57/)

Quick answers

## IST6-500, 10 × 50 kVA: quick answers

**What it is**: The IST6 500 kVA is the largest cabinet of the 50 kVA platform: ten 50 kVA power modules and a 4.5U bypass module in a 1203 × 864 × 2000 mm double column.

**Who it is for**: For large data centres and buildings with 400 to 500 kW per UPS, or up to eight UPS in parallel and multi-bus systems.

**Supply and configuration**: 380 / 400 / 415 V

**Battery and backup**: ±240 V DC nominal (±180 … ±300 V), 30–50 × 12 V blocks, standard 40

**Size and weight**: 1203 × 864 × 2000 mm · 506 kg without modules

**Ordering code**: IST6-500

IST6 200–500

## What sets apart the IST6-500, 10 × 50 kVA

500 kVA is also sold on the 100 kW-module frame, as a different product: the IST6 500 kVA with 5 × 100 kVA modules, one 801 × 1000 × 2000 mm column of 434 kg without modules, against this double column of 1203 × 864 × 2000 mm.

The 500 kVA takes ten modules and a taller 4.5U bypass module (3U on the 200–400 kVA), at 506 kg without modules. Its ordering code is IST6-500. Fully loaded it draws 863 A at the mains on 2 × (4 × 240) mm² with a 1000 A 3P breaker, 758 A at bypass and output, and 1085 A from a 40-block battery on 3 × (3 × 240) mm².

It needs 6050 m³/h of cooling air. With power walk-in, the rectifier takes the load back from the battery gradually when the mains returns, which avoids a step on the upstream transformer or generator at this size.

- **Against the IST6-400, 8 × 50 kVA** (one size down): Power modules · rating 10 × 50 kVA against 8 × 50 kVA; Bypass module 500 kVA · 4.5U against 400 kVA · 3U; Weight without power modules 506 kg against 459 kg.

Planning data

## IST6-500, 10 × 50 kVA: currents, breakers, cables, batteries

The rows and columns of the EMEA 2026 catalogue's and AEC manuals' tables that concern the IST6-500, 10 × 50 kVA.

### Four cabinets, one 50 kVA module

**IST6-500, 10 × 50 kVA · Four cabinets, one 50 kVA module**

| Cabinet | 500 kVA |
| --- | --- |
| Power modules (50 kVA) | 10 |
| Bypass module | 500 kVA · 4.5U |
| W × D × H (mm) | 1203 × 864 × 2000 |
| Weight without power modules | 506 kg |
| Mains input current | 863 A |
| Cooling air flow (min.) | 6050 m³/h |

### Site conditions and service

**IST6-500, 10 × 50 kVA · Site conditions and service**

| Line | 500 kVA |
| --- | --- |
| Mains input | 863 A · 2×(4×240) |
| Bypass / output | 758 A · 2×(4×240) |
| Battery (40 blocks) | 1085 A · 3×(3×240) |
| Mains breaker | 1000 A 3P |

Installation

## Installing the IST6-500, 10 × 50 kVA: space, heat, cables

Each figure with its source. Heat is the power lost at the peak efficiency stated.

**IST6-500, 10 × 50 kVA · installation**

| Item | Figure | Source |
| --- | --- | --- |
| Clearances | front 800 mm, rear 500 mm, top 500 mm; left and right: not given | AEC user manual Table 3-1; EMEA 2026 catalogue p.157 |
| Cable entry | Bottom (standard); Top (built to order) | AEC user manual Table 3-1; EMEA 2026 catalogue p.157 |
| Heat at full load | 9.68 kW at 500 kW load, 98.1 % efficiency | IST6 200–500 data (up to 98.1 %, AEC); output PF 1 (EMEA 2026 catalogue) |
| Operating temperature | 0 to 40 °C | IST6 200–500 AEC user manual |
| Switches and terminals | Mains, bypass, maintenance bypass and output switches inside the front door (single column 1,148–1,711 mm up; double column on the left, 462–1,658 mm). | IST6 200–500 user manual §3.5.1 p.43 (right-hand hinges, one door per column) |
| Door | One leaf, hinged on the right | IST6 200–500 user manual §3.5.1 p.43 (right-hand hinges, one door per column) |
| Module withdrawal | 650 mm in front of the cabinet to withdraw a module | EMEA 2026 catalogue p.143; AEC user manual A.2.1 |
| Units in parallel | Up to 8 units | AEC user manual A.1.2; EMEA 2026 catalogue p.139 |

Size and floor

## How big it is

1203 × 864 × 2000 mm · 506 kg without modules.

**1.04 m²** footprint

**2 m** height

Efficiency

## How efficient is the AEC IST6-500, 10 × 50 kVA at your load?

IST6-500, 10 × 50 kVA, 500 kW at its rating, online, double conversion (typical curve, AEC's method). Heat to remove on this curve: 25%: 3.21 kW (η 97.5%) · 50%: 4.84 kW (η 98.1%) · 75%: 8.44 kW (η 97.8%) · 100%: 12.8 kW (η 97.5%). At 50% load, 24/7, it loses about 42,416 kWh a year.

**98.1** % 50% · Typical curve, derived from the datasheet efficiency of 98.1% (AEC method)

How the curve is drawn and where each figure comes from: [the IST6 200–500 range page](https://www.aecups.com/en/products/ist6-200-500/#efficiency). ECO and W-ECO modes are listed without an efficiency figure.

**Load**: —

**Lost as heat**: —

**Energy lost in a year, 24/7**: —

**Its cost in a year at € per kWh**: —

The catalogue's examples use €0.20 per kWh.

#### Where each figure comes from

| Mode | Efficiency | Kind | Models | Source |
| --- | --- | --- | --- | --- |
| Online, double conversion | 25%: 97.5% · 50%: 98.1% · 75%: 97.8% · 100%: 97.5% | Typical curve, derived from the datasheet efficiency of 98.1% (AEC method) | all | AEC datasheet: AC/AC efficiency of the IST6-PM100 100 kW power module (the curve's shape) |
| ECO | 99.2% | Datasheet figure, load not stated | all | AEC datasheet: AC/AC efficiency of the IST6-PM100 100 kW power module (the curve's shape) |

EMEA 2026 catalogue figures: Online, double conversion up to 98.1%.

Drag to turn

In 3D

## Look around the IST6-500, 10 × 50 kVA

[Open full 3D · X-ray](https://www.aecups.com/assets/models3d/ist6-50m-500/v57/)

Technical data

## Technical data IST6-500, 10 × 50 kVA

Only this model's values, from the EMEA 2026 catalogue table.

**IST6-500, 10 × 50 kVA · Technical data**

|  |  |
| --- | --- |
| Cabinet |  |
| Power modules · rating | 10 × 50 kVA |
| Bypass module | 500 kVA · 4.5U |
| Input |  |
| System · voltage | 3Ph+N+PE · 380 / 400 / 415 V; 138–485 V (full power 324–485 V, linear derating below) |
| Frequency · PF · THDi | 40–70 Hz · ≥ 0.99 · ≤ 1.5% at full load |
| Bypass | 304–438 V; synchronisation 50 ± 5 / 60 ± 6 Hz; settable window |
| Battery |  |
| Lead-acid | ±240 V DC nominal (±180 … ±300 V), 30–50 × 12 V blocks, standard 40 |
| Lithium (with BMS card) | ±256 V DC nominal (±192 … ±294.4 V), 120–200 cells, standard 160 |
| Charging current | up to 30 A × number of modules · cold start · shared battery |
| Output |  |
| System · voltage | 3Ph+N+PE (3Ph+PE optional) · 380 / 400 / 415 V ± 1% |
| Power factor · THDv | settable 0.8–1.0 (default 1.0) · ≤ 1% linear, ≤ 4% non-linear |
| Frequency · phase error | tracks the bypass; 50 / 60 ± 0.1 Hz with mains abnormal · ≤ 1° balanced, ≤ 3° unbalanced |
| Transfer | mains ↔ battery 0 ms · bypass ↔ inverter < 1 ms synchronised, < 15 ms |
| Inverter overload (PF 1) | ≤ 105% continuous · 105–110% 60 min · 110–125% 10 min · 125–150% 1 min · > 150% to bypass |
| Bypass overload | ≤ 130% continuous · 130–150% 5 min · 150–200% 1 min · 200–300% 100 ms |
| System |  |
| Efficiency · modes | up to 98.1% · ECO, WECO, source share, redundancy sleep |
| Parallel | up to 8 UPS, current imbalance ≤ 5% · BSC dual bus and multi-bus (3 buses) |
| Communication | Modbus · RS232 · RS485 · 4 inputs / 3 outputs dry contact · options: SNMP, expansion, BMS |
| Environment | 0 … 40 °C · 0–95% RH · ≤ 2000 m (derating to 4000 m) · IP20 · < 70 dB · EMC C3 |
| W × D × H (mm) | 1203 × 864 × 2000 |
| Weight without power modules | 506 kg |

**IST6-500, 10 × 50 kVA · Models**

| Item | IST6-500, 10 × 50 kVA |
| --- | --- |
| Power modules (50 kVA) | 10 |
| Bypass module | 500 kVA · 4.5U |
| W × D × H (mm) | 1203 × 864 × 2000 |
| Weight without power modules | 506 kg |
| Mains input current | 863 A |
| Cooling air flow (min.) | 6050 m³/h |

Power module 500 × 650 × 130 mm, 39 kg. Data from the IST6 200–500 kVA user manual. Specifications are subject to change without notice.

#### **More technical details** how it works, ordering codes

Diagrams

## How the power flows: AEC IST6-500, 10 × 50 kVA

Pick an operating mode: the path the power takes to the load lights up.

**Normal.** Double conversion: the rectifier feeds the DC bus, the inverter rebuilds a clean voltage and the load always runs on the inverter. The battery stays on charge. Efficiency up to 98.1% (double conversion, up to; ECO and WECO modes stated without a figure).

### Modules and redundancy

Move the slider: the modules the load needs light up, and the spare slot holds the N+1 redundancy. Each slot takes one 50 kVA module.

modules working · redundant · free slot

Ordering codes

## Ordering codes IST6-500, 10 × 50 kVA

**Ordering codes IST6-500, 10 × 50 kVA**

| Code | Description |
| --- | --- |
| IST6-500 | Modular cabinet, max. 10 × 50 kVA power modules, without modules |
| IST6-50-J | 50 kVA / 50 kW power module |
| PAR - IST6 | Parallel kit |

Questions

## Questions about the IST6-500, 10 × 50 kVA

#### Is there an ordering code for the IST6 500 kVA?

Yes: IST6-500 is the 500 kVA cabinet for up to ten 50 kVA modules, without modules; the power modules are IST6-50-J. Ask AEC with the load and backup time and AEC sends the configuration.

#### What protects the load if a downstream circuit shorts?

The 50 kVA modules supply a high short-circuit current for a set time, 20 to 200 ms, so the breaker of the faulty circuit trips while the other loads keep running. Backfeed protection opens the backfeed device if the static bypass fails.

#### How big is the AEC IST6-500, 10 × 50 kVA and how much does it weigh?

The AEC IST6-500, 10 × 50 kVA measures 1203 × 864 × 2000 mm; weight: 506 kg without modules (size from AEC's CAD drawing, weight from the EMEA 2026 catalogue).

#### What is the ordering code of the AEC IST6-500, 10 × 50 kVA?

In the EMEA 2026 catalogue the AEC IST6-500, 10 × 50 kVA is listed as IST6-500; AEC gives the full code, batteries included, from the load and the backup time.

Related models

## The same range: IST6 200–500

[The whole range](https://www.aecups.com/en/products/ist6-200-500/)

[**IST6-200, 4 × 50 kVA** 200 kVA](https://www.aecups.com/en/products/ist6-200-500/ist6-200k-4x50/) [**IST6-300, 6 × 50 kVA** 300 kVA](https://www.aecups.com/en/products/ist6-200-500/ist6-300k-6x50/) [**IST6-400, 8 × 50 kVA** 400 kVA · smaller rating](https://www.aecups.com/en/products/ist6-200-500/ist6-400k-8x50/) **IST6-500, 10 × 50 kVA** 500 kVA

Batteries and cabinets: [L6 Lithium](https://www.aecups.com/en/products/l6-lithium/) Accessories: [SNMP card](https://www.aecups.com/en/products/snmp-card/) [Dry contact card](https://www.aecups.com/en/products/dry-contact-card/)

Shared by the whole range, on the IST6 200–500 page: [the display simulator](https://www.aecups.com/en/products/ist6-200-500/#display) · [the catalogue's photos and drawings](https://www.aecups.com/en/products/ist6-200-500/#gallery).

Read next: [Modular UPS: how to grow power module by module](https://www.aecups.com/en/blog/modular-ups/) [UPS redundancy: N+1 or 2N, and how much a site needs](https://www.aecups.com/en/blog/ups-redundancy-n-plus-1/) [UPS for data centres: how to choose and plan](https://www.aecups.com/en/blog/ups-for-data-centres/)

## Talk to an AEC engineer

Tell us the load, the supply and the backup time you need for the AEC IST6-500, 10 × 50 kVA: we answer with the model and the batteries that fit. AEC International sells through distributors in about 80 countries and an agency in every Italian region: ask AEC which one serves your area.

[Contact us](https://www.aecups.com/en/contacts/?interest=Modular%20UPS&msg=About%20the%20AEC%20IST6-500%2C%2010%20%C3%97%2050%20kVA%20(IST6%20200%E2%80%93500)%3A%20%0AQuantity%3A%20#form) [+39 02 9415 8991](tel:+390294158991)