Three-phase UPS · 400 V

# IST7 60–200 Three-phase online UPS, 400 V

VRLA Online double conversion

The AEC IST7 60–200 is a three-phase online double-conversion UPS for 400 V supplies in six ratings from 60 to 200 kVA, in two cabinet sizes. Output power factor 1 (kVA = kW), 96.5% peak efficiency and 99% in ECO mode, input THDi ≤ 3% at full load; up to 8 units in parallel for 1.6 MW with N+X redundancy.

**96.5%** peak efficiency

**PF 1** output power factor

**≤3%** input THDi at full load

**1.6 MW** 8 units in parallel

Datasheet Manuals and catalogues [Contact us](https://www.aecups.com/en/contacts/?interest=Three-phase%20UPS&msg=About%20the%20AEC%20IST7%2060%E2%80%93200%3A%20%0AQuantity%3A%20#form)

[**Try 3D** X-ray view](https://www.aecups.com/assets/models3d/ist7-120/v65/)

Drag to turn

In 3D

## Look around the IST7 60–200

Drag it round, swipe on a phone or use the arrow keys. X-ray makes the enclosure see-through, so you can see what sits behind the panels.

[Open full 3D · X-ray](https://www.aecups.com/assets/models3d/ist7-120/v65/)

Pick a size: the turn and the full 3D view follow it. Rendered from AEC's 3D models; the full 3D view zooms in, opens the unit and names every part.

Hands on

## Open the IST7 60–200 yourself.

Click the unit: the door opens. Drag to move it by hand. The 3D shows every part.

[Every part in 3D](https://www.aecups.com/assets/models3d/ist7-120/v65/)

Efficiency

## How efficient is the AEC IST7 60–200 at your load?

AC/AC efficiency of each operating mode against the load: AEC's measured curves where they exist, elsewhere the typical curve derived from the datasheet figure by AEC's method. The losses and their cost follow the curve at the load you choose: drag along the chart or move the slider.

**96.5** % 50% · Typical curve, derived from the datasheet efficiency of 96.5% (AEC method)

Filled points: measured by AEC (AC/AC technical datasheet). Hollow points: a typical curve, the shape of the most similar measured curve (same technology and size) moved to the range's datasheet efficiency: η(load) = reference curve + (datasheet figure − its highest point), AEC's method. Dashed lines: one figure without a load (ECO, W-ECO). Between points the efficiency is read on a straight line; beyond them, the nearest end. Losses = P × (1/η − 1).

**Load**: —

**Lost as heat**: —

**Energy lost in a year, 24/7**: —

**Its cost in a year at € per kWh**: —

The catalogue's examples use €0.20 per kWh.

#### Where each figure comes from

| Mode | Efficiency | Kind | Models | Source |
| --- | --- | --- | --- | --- |
| Online, double conversion | 25%: 95.9% · 50%: 96.5% · 75%: 96.2% · 100%: 95.9% | Typical curve, derived from the datasheet efficiency of 96.5% (AEC method) | all | AEC datasheet: AC/AC efficiency of the IST6-PM100 100 kW power module (the curve's shape) |
| ECO | 99% | Datasheet figure, load not stated | all |  |

EMEA 2026 catalogue figures: Online, double conversion up to 96.5% · ECO up to 99%.

The display

## The IST7 60–120 kVA display

The real display, drawn by AEC's own simulator: pick a UPS state (normal, battery, bypass) or a main page.

UPS state

IST7 60–120 kVA · the real display

### Normal operation

**Main pages**

**IST7 60 kVA in 3D, the display** The camera moves in to the display. · 0:06

What is what

## Inside the IST7 60–200, part by part.

Each number on the picture is named in the list.

### Front, door open · 60–120 kVA

Switchgear behind the lockable door; all communication ports on the bypass and control unit. Cables enter from below.

1. **Power unit** PFC rectifier, three-level inverter and battery booster in one unit, with RUN / ALARM / FAULT LEDs. 60–120 kVA: one unit; 160–200 kVA: two.
2. **Bypass and control unit** Static bypass, system control card and all the communication ports in one place: dry contacts, EPO, parallel, RS485, Modbus RTU, RS232, SNMP and expansion slots.
3. **Battery cold start** Starts the UPS from the battery when there is no mains and no bypass.
4. **Mains input switch** The rectifier's mains supply.
5. **SPD switch** Optional: the disconnect switch of the surge protection device.
6. **Output switch** To the load.
7. **Bypass input switch** The static bypass supply.
8. **Surge protection (SPD)** Optional class C SPD, for sites exposed to lightning.
9. **Maintenance bypass switch** Manual bypass: the load stays supplied while the UPS is de-energised for service.

### Front, door open · 160–200 kVA

160–200 kVA: two power units above the bypass and control unit; the four switches below.

1. **Power units**
2. **Bypass and control unit**
3. **Battery cold start**
4. **Mains input switch**
5. **Output switch**
6. **Bypass input switch**
7. **Maintenance bypass switch**

### Communication ports

All the communication ports are on the bypass and control unit.

1. **Battery cold start** Starts the UPS from the battery when there is no mains and no bypass.
2. **SNMP card slot** Optional SNMP card: Ethernet web monitoring, COM1 (RS485) for a temperature and humidity sensor.
3. **RS485 parallel monitoring** RS485 port for the monitoring of a parallel system.
4. **Dry contacts, EPO, battery temperature** 4 inputs (10 functions) and 3 changeover outputs NO / NC (18 functions), each assigned from the display; EPO; battery temperature probe.
5. **Parallel ports** Up to 8 units in a ring: N units, N cables, two links per unit (parallel kit PAR-IST7-60/200).
6. **Expansion slot** Optional dry-contact expansion (+3 inputs, +2 outputs) or BMS card for lithium battery communication.
7. **Control card LEDs** Status LEDs of the system control card.
8. **EPO2 input** Second emergency power off input, normally closed.
9. **Modbus RTU and RS232** Serial ports for building management and monitoring software.
10. **Touch-screen port** Link to the touch screen on the door.

**IST7 60 kVA in 3D, door open** The door opens on what is inside. · 0:06

Overview

## Key facts

**Power range**: 60–200 kVA

**Input / output**: 220 / 230 / 240 V L-N · 380 / 400 / 415 V L-L

**Efficiency**: up to 96.5% double conversion · 99% ECO mode

**Battery**: ±192 V · ±216 V

**Display**: Colour touch screen, 5 status LEDs, ambient light bar

**Communication**: RS485 · Modbus RTU · RS232 · 4 IN / 3 OUT dry contacts · EPO · SNMP slot

**Network card**: SNMP card (optional)

**Parallel**: Up to 8 units, capacity or N+X · BSC dual-bus synchronisation

**Warranty**: 3 years

**Dimensions W × D × H**: 400 × 960 × 1193 · 600 × 1000 × 1600 mm

[Applications](https://www.aecups.com/en/applications/): Network & IT rooms Telecommunications Finance & insurance Transport Energy & industry Public sector & education

Pictures

## The IST7 60–200 in pictures

The photos and drawings of the EMEA 2026 catalogue: product views, displays, modules and connections. Tap a picture to enlarge it.

Models

## Which IST7 60–200 fits your load?

Every rating has its own page: that model's technical data, ordering codes, batteries and the questions people ask.

[**IST7-60** 60 kVA The IST7-60 is a 60 kVA / 60 kW three-phase online double-conversion UPS with a three-level inverter, in a 400 × 960 × 1193 mm cabinet of 153 kg. **400 × 960 × 1193 mm**Size **153 kg**Weight See the model](https://www.aecups.com/en/products/ist7-60-200/ist7-60k/) [**IST7-80** 80 kVA The IST7-80 is an 80 kVA / 80 kW three-phase online UPS built on the IST7-100's hardware, upgradable to 100 or 120 kVA from the display. **400 × 960 × 1193 mm**Size **163 kg**Weight See the model](https://www.aecups.com/en/products/ist7-60-200/ist7-80k/) [**IST7-100** 100 kVA The IST7-100 is a 100 kVA / 100 kW three-phase online double-conversion UPS in a 400 mm wide cabinet, upgradable to 120 kVA from the display. **400 × 960 × 1193 mm**Size **165 kg**Weight See the model](https://www.aecups.com/en/products/ist7-60-200/ist7-100k/) [**IST7-120** 120 kVA The IST7-120 is a 120 kVA / 120 kW three-phase online double-conversion UPS, the largest in the 400 mm cabinet, at 167 kg. **400 × 960 × 1193 mm**Size **167 kg**Weight See the model](https://www.aecups.com/en/products/ist7-60-200/ist7-120k/) [**IST7-160** 160 kVA The IST7-160 is a 160 kVA / 160 kW three-phase online UPS with two power units in a 600 × 1000 × 1600 mm cabinet, upgradable to 200 kVA. **600 × 1000 × 1600 mm**Size **294 kg**Weight See the model](https://www.aecups.com/en/products/ist7-60-200/ist7-160k/) [**IST7-200** 200 kVA The IST7-200 is a 200 kVA / 200 kW three-phase online double-conversion UPS, the largest IST7, with two power units in a 600 × 1000 × 1600 mm cabinet of 296 kg. **600 × 1000 × 1600 mm**Size **296 kg**Weight See the model](https://www.aecups.com/en/products/ist7-60-200/ist7-200k/)

Datasheet

## Datasheet IST7 60–200.

Every model side by side: keep only what differs, take it as CSV or print it.

**IST7 60–200 · Technical data**

| Model | IST7-60 | IST7-80 | IST7-100 | IST7-120 | IST7-160 | IST7-200 |
| --- | --- | --- | --- | --- | --- | --- |
| General |  |  |  |  |  |  |
| Rated power (kVA / kW) | 60 | 80 | 100 | 120 | 160 | 200 |
| Capacity upgrade | — | to 100 / 120 | to 120 | — | to 200 | — |
| Input |  |  |  |  |  |  |
| Connection | 3 phases + N + PE |  |  |  |  |  |
| Rated voltage | 220 / 230 / 240 V phase (380 / 400 / 415 V line) |  |  |  |  |  |
| Voltage range | 187–280 V phase at full power · 80–186 V with linear derating |  |  |  |  |  |
| Frequency · power factor · THDi | 40–70 Hz · ≥ 0.99 · ≤ 3% at full load |  |  |  |  |  |
| Bypass synchronisation range | 50 / 60 Hz ± 6 Hz |  |  |  |  |  |
| Battery |  |  |  |  |  |  |
| Nominal DC voltage (default) | ±192 V | ±192 V | ±216 V | ±216 V | ±216 V | ±216 V |
| String length | 28–48 × 12 V blocks, set on site · VRLA or lithium (BMS card) |  |  |  |  |  |
| Max. charge current | 30 A | 60 A |  |  |  |  |
| Output |  |  |  |  |  |  |
| Voltage · frequency | 220 / 230 / 240 V phase · 50 / 60 Hz (± 0.1 Hz on battery) |  |  |  |  |  |
| Power factor · THDv | 1 (settable 0.9) · ≤ 1% linear, ≤ 4% non-linear load |  |  |  |  |  |
| Transient · unbalance · phase error | ≤ 5% for 0–100–0% step · 100% unbalanced load · ≤ 1° |  |  |  |  |  |
| Transfer time inverter ↔ bypass | < 1 ms synchronised · < 15 ms not synchronised |  |  |  |  |  |
| Inverter overload | ≤ 105% continuous · ≤ 110% 60 min · ≤ 125% 10 min · ≤ 150% 1 min (IST7-120: > 125% immediate) |  |  |  |  |  |
| Bypass overload | ≤ 130% continuous · ≤ 150% 5 min · ≤ 200% 1 s · ≤ 300% 100 ms |  |  |  |  |  |
| System |  |  |  |  |  |  |
| Efficiency AC/AC | up to 96.5% double conversion · 99% ECO mode |  |  |  |  |  |
| Parallel | Up to 8 units, capacity or N+X · BSC dual-bus synchronisation |  |  |  |  |  |
| Communication | RS485 · Modbus RTU · RS232 · 4 IN / 3 OUT dry contacts · EPO · SNMP slot · expansion slot |  |  |  |  |  |
| Display | Colour touch screen, 5 status LEDs, ambient light bar, 10,000 events and 10,000 user-log entries |  |  |  |  |  |
| Environment | −5 … 40 °C · 0–95% RH · IP20 · < 65 dB at 1 m · forced-air cooling |  |  |  |  |  |
| Cable entry | bottom (all models) |  |  |  |  |  |
| EMC | [IEC 62040-2](https://webstore.iec.ch/en/publication/33696):2016 · category C3 (not for residential use without additional measures) |  |  |  |  |  |
| Dimensions W × D × H | 400 × 960 × 1193 mm | 600 × 1000 × 1600 mm |  |  |  |  |
| Weight | 153 kg | 163 kg | 165 kg | 167 kg | 294 kg | 296 kg |

IST7-80: same hardware as IST7-100, upgradable to 100 or 120 kVA from the display. Specifications are subject to change without notice.

#### **Full technical details** 17 sections of the EMEA 2026 catalogue: functions, panel, connections, diagrams and ordering codes

### Why IST7 60–200

01 **96.5% · Efficiency that lowers losses** Peak AC/AC efficiency in online double conversion; up to 99% in ECO mode, with automatic return to the inverter when the bypass leaves tolerance.

02 **kVA = kW · Full rating as active power** Unity output power factor: a 120 kVA unit delivers 120 kW. Output PF can also be set to 0.9.

03 **80 → 120 · Power that follows the load** IST7-80 is upgraded to 100 or 120 kVA, IST7-100 to 120 kVA, IST7-160 to 200 kVA, by setting the capacity from the display. Same hardware, same footprint.

04 **8 units · Parallel up to 1.6 MW** Capacity or N+X redundant systems with up to 8 units. BSC synchronisation for dual-bus architectures.

05 **≤3% THDi · Clean input, wide window** PFC rectifier with input PF ≥ 0.99. Full power from 187 to 280 V phase voltage, linear derating down to 80 V.

06 **10,000 · Records for diagnosis** Up to 10,000 events and 10,000 user-log entries, plus smart wave capture of the fault instant, on a colour touch screen with three access levels.

OPERATING COST

## What efficiency means at 100 kW

Losses are the energy the UPS turns into heat: you pay for it once at the meter and again in the room cooling.

- Online double conversion at 96.5%: 3.6 kW lost, 31,800 kWh per year, ≈ € 6,350 per year
- ECO mode at 99%: 1.0 kW lost, 8,850 kWh per year, ≈ € 1,770 per year
- Basis: 100 kW load, 24/7 operation, € 0.20/kWh, calculated at peak efficiency; losses = P × (1/η − 1). Indicative values.
- In ECO mode the load is fed through the bypass while the mains stays within the set window (default ±15% voltage, ±2% frequency).

**What efficiency means at 100 kW**

| Mode | Losses | Energy lost / year | Cost / year |
| --- | --- | --- | --- |
| Online double conversion · 96.5% | 3.6 kW | 31,800 kWh | ≈ € 6,350 |
| ECO mode · 99% | 1.0 kW | 8,850 kWh | ≈ € 1,770 |

ARCHITECTURE

## Three functional units behind one door

The rectifier converts the mains to DC with input PF ≥ 0.99; the inverter rebuilds a clean sine wave for the load. When the mains fails, the booster feeds the DC bus from the batteries with no break at the output. The static bypass takes over on overload or inverter fault; the maintenance bypass isolates the UPS for service.

- Power unit: PFC rectifier, three-level inverter and battery booster in one unit, with RUN / ALARM / FAULT LEDs and a limit switch that puts the unit in or out of service
- Bypass and control unit: static bypass, system control card, communication ports and the battery cold-start button
- Switchgear: mains input, bypass input and output switches, accessible behind the lockable door
- Maintenance bypass: manual bypass switch; the load stays supplied while the UPS is de-energised for service
- Surge protection (option): class C SPD with its own disconnect switch, for sites exposed to lightning
- 160–200 kVA: 2 power units · 60–120 kVA: 1 power unit
- 80 → 100 → 120 kVA · 160 → 200 kVA: IST7-80 uses the same hardware as IST7-100 and is upgraded to 100 or 120 kVA, IST7-100 to 120 kVA, IST7-160 to 200 kVA; the rated capacity is set from the display at engineering level, inside the same footprint

DESIGN AND INSTALLATION

## Front, rear and footprint

Two cabinets with the same layout: 400 mm wide for 60–120 kVA, 600 mm wide for 160–200 kVA. Cooling air enters at the front and leaves at the rear.

- Operation panel: colour touch screen, five status LEDs, two-key ON / OFF commands and an ambient light bar that shows the UPS state across the room
- Perforated front door, lockable; cooling air enters from the front, fan speed follows the load
- Perforated rear panel: hot-air outlet; keep the openings on the front and rear free
- Cable entry (input, output, battery and PE): from below on all models
- Indoor, IP20, forced-air cooling
- Operating temperature −5 … 40 °C, humidity 0–95%
- Noise < 65 dB at 1 m from the front
- 60–120 kVA: castors for positioning, then anchored to the floor; 160–200 kVA: bolted to the floor
- Self-dedusting every 360 h (default); optional fan and capacitor service-life alarms
- Free space ≥ 800 mm at the front, rear and above; air in at the front, out at the rear
- IST7-80: same hardware as IST7-100

**Front, rear and footprint**

| Model | W × D × H (mm) | Weight |
| --- | --- | --- |
| IST7-60 | 400 × 960 × 1193 | 153 kg |
| IST7-80 | 400 × 960 × 1193 | 163 kg |
| IST7-100 | 400 × 960 × 1193 | 165 kg |
| IST7-120 | 400 × 960 × 1193 | 167 kg |
| IST7-160 | 600 × 1000 × 1600 | 294 kg |
| IST7-200 | 600 × 1000 × 1600 | 296 kg |

TECHNOLOGY

## Three-level inverter, fully digital DSP control

The inverter switches between +Vdc, 0 and −Vdc instead of two levels. Smaller voltage steps give lower switching losses and a cleaner output. A DSP controls inversion, synchronisation and current sharing between parallel units.

- Grid-friendly input: PFC rectifier, input PF ≥ 0.99 and THDi ≤ 3% at full load, 40–70 Hz
- Full power from 187 to 280 V phase voltage (rated 220–240 V); from 186 V down to 80 V the rated power decreases linearly; below 80 V and outside the window the batteries take over
- Output THDv ≤ 1% with linear load (≤ 4% non-linear)
- 100% unbalanced load accepted on the three phases
- Voltage transient ≤ 5% for a 0–100–0% load step
- Transfer inverter ↔ bypass < 1 ms when synchronised (< 15 ms unsynchronised)
- Overload, inverter (linear load): 105% continuous, 110% 60 min, 125% 10 min, 150% 1 min; > 150% immediate protection; IST7-120: above 125% immediate protection
- Overload, static bypass: 130% continuous, 150% 5 min, 200% 1 s, 300% 100 ms; > 300% immediate protection; handles inrush and fault-clearing currents up to 300% for 100 ms
- Cooling that adapts: fan speed follows the load, extending fan life and lowering noise at partial load; timed self-dedusting every 360 h by default; optional service-life alarms for fans and bus capacitors (lifetime settable, default 10 years)
- Protections: output short-circuit, over- and under-voltage; overload and over-temperature; battery under-voltage (two levels); communication fault between units; EMC to IEC 62040-2:2016

**Three-level inverter, fully digital DSP control**

| Overload | Continuous | Step 2 | Step 3 | Step 4 | Immediate protection |
| --- | --- | --- | --- | --- | --- |
| Inverter, linear load | 105% | 110% · 60 min | 125% · 10 min | 150% · 1 min | > 150% (IST7-120: > 125%) |
| Static bypass | 130% | 150% · 5 min | 200% · 1 s | 300% · 100 ms | > 300% |

OPERATOR PANEL

## Single-line diagram, five LEDs, ambient light bar

Colour touch screen with live single-line diagram, five status LEDs, two-key ON / OFF commands and an ambient light bar that shows the UPS state in colour, also when the display backlight is off.

- Colour touch screen: live single-line diagram, measurements, settings and records
- Five status LEDs (AC/DC, DC/AC, bypass, battery, overload): green when active or normal, red when abnormal
- ON keys: press both keys for 3 s to power on; two keys prevent accidental switching
- OFF keys: press both keys for 3 s; the inverter stops and the load moves to bypass
- Ambient light bar: blue = normal operation; blue flashing = battery mode; yellow = abnormal, load still supplied; red = abnormal, output off
- Screen settings: ambient light on / off; backlight time 1–999 min (default 5); brightness, language, date and time

Tap a light: green is normal operation, red an abnormal state, as in the catalogue's table.

AC/DC: green, Rectifier normal

**Single-line diagram, five LEDs, ambient light bar**

| LED | Green | Red |
| --- | --- | --- |
| AC/DC | Rectifier normal | Rectifier abnormal |
| DC/AC | Inverter normal | Inverter abnormal |
| BYP. | Bypass output | Bypass abnormal |
| BATT. LOW | Battery mode | Battery low voltage |
| OVERLOAD | Output normal | Output overload |

TOUCH SCREEN

## Touch a block, read its measurements

The home page draws the UPS as it runs: yellow dots trace the active power path, faulty blocks turn red, and the bottom line shows output voltage and frequency. Touch any block (bypass, mains, battery, rectifier, inverter, output) to open its page.

- Bypass info: phase voltage, current and frequency of the bypass input
- Mains info: phase voltage, current, frequency and input energy (MWh)
- Battery info: positive and negative battery voltage, charge and discharge current, status
- Inverter info: output phase voltage, current and frequency of the inverter
- Information menu: running info, history, user log, smart records, device info, wave capture
- Settings menu: cabinet, battery, battery test, output, smart mode, dry contacts, screen, password, communication, records
- Running info: UPS info, parameter match between units, UPS status
- Device info: hardware, software and series version of each unit
- 3 access levels (user, engineer, factory), each with its own password
- USB port on the screen for record export and firmware update
- 1–999 minutes of backlight time, then the light bar keeps showing the state
- 5 status LEDs and two-key ON / OFF commands below the screen

RECORDS

## Every event recorded, ready to export

The UPS keeps a history of up to 10,000 events and a user log of up to 10,000 entries, plus smart records and wave captures, all exportable to a USB stick.

- History record: 10,000 events with fault and alarm information of the system and of each unit, newest first
- User log: every setting change with date and time, up to 10,000 entries; when a record is full, the oldest entry is overwritten
- Current alarms: opened from the alarm icon on the home page, active faults time-stamped
- Smart records: records linked to the smart-mode settings, such as redundancy
- Smart wave capture: when an abnormal event occurs, the UPS stores the waveforms around it with date, time and abnormal information; three sources (rectifier, inverter, system card); parameters shown on four channels are selectable
- Download to USB (FAT32 stick) from the record manage page: history record, user log, smart records, smart wave capture, battery discharge record
- Firmware is updated the same way, from a USB stick

OPERATION

## Every operating state, shown live

Real screens of the IST7: the yellow dots trace the active power path.

- Online double conversion: mains → rectifier → inverter → load; batteries kept charged; load isolated from mains disturbances
- Battery mode: mains out of limits; the batteries feed the inverter through the booster, with no break at the output
- Static bypass: on overload or inverter fault the load moves to the bypass and returns to the inverter when the cause is cleared
- Maintenance bypass: manual switch; the load is fed directly while the UPS is de-energised for service
- ECO, up to 99%: load on bypass while the mains is within the window (default ±15% V, ±2% f); Standard ECO and W-ECO selectable
- Frequency converter: rectifier and inverter decouple input and output frequency; output set to 50 Hz or 60 Hz
- Self-load test: output switch open, the power circulates back to the input, testing the UPS at 1–100% load for 1–1440 h
- Generator mode: start manual or by dry contact from the ATS; generator rated power and charge-power derating set on screen, so the genset is not overloaded
- Transfers: 0 ms mains → battery (DC bus fed by the booster without interruption); < 1 ms inverter ↔ bypass synchronised (< 15 ms not synchronised); automatic return from bypass to inverter once overload or fault is cleared; 3 restart attempts after an output short circuit, then protection
- Typical use: Online for data centres, healthcare and industry (the load never sees the mains); ECO for stable mains and tolerant loads, when the lowest losses matter most; frequency converter for 60 Hz machines on a 50 Hz grid or the other way round; generator mode for sites with a genset (controlled start and limited load on the generator)

SMART FUNCTIONS

## Functions that look after the UPS and the site

Set from the Smart mode pages of the touch screen. Cooling air enters at the front and leaves at the rear; a timed self-dedusting function keeps the air path clear between service visits.

- Self-cleaning, timed: default every 360 h, period settable
- Self-cleaning, forced: started on demand from the screen
- Self-cleaning, logged: "Fan dedusting" event in the records
- Also on the same page: fan mode, fan and bus capacitor service-life alarms (default service life 10 years)
- Frequency converter, 50 ↔ 60 Hz: supplies 60 Hz loads from a 50 Hz grid or the other way round, e.g. marine, test benches or imported machinery
- Generator mode: start manual or by dry contact from the ATS; generator rated power and charge-power derating set on screen
- Self-load test: load 1–100%, time 1–1440 h; burn-in without a load bank
- Fan speed follows the load: quieter at partial load, longer fan life
- Automatic start when the mains returns
- Cold start from the battery, without mains
- Short-circuit protection time 20 ms (default), up to 200 ms
- Output voltage fine-tuning ±10 V; output PF 1 or 0.9
- Bypass window +10/15/20%, −10/15/20%; frequency range 2–20%

PARALLEL SYSTEMS

## Parallel, redundancy and common battery

Up to 8 units on one load bus, with parallel address 1–8 set from the display. Units are linked by parallel cables in a ring: N units, N cables, so each unit always has two connections.

- Common battery: the units of a parallel system share the same battery bank (fewer cabinets, less floor space, one string to maintain); each unit can also keep its own batteries
- Mode manage: single or parallel mode, parallel address and BSC address
- Capacity or N+X redundancy: basic quantity and redundancy quantity of the parallel system
- Power grows by adding units: up to 1.6 MW with 8 × IST7-200 (200 kVA)
- BSC: the synchronous output of the dual bus control synchronises two independent UPS systems in frequency and phase, so dual-corded loads and static switches can move between bus A and bus B
- Current sharing between units ≤ 5%
- Parameter match page shows any setting that differs between units; one command copies the settings to all units
- Staggered start of the units to limit inrush on the source
- Optional EPO linkage: one stop button for all units
- Parallel kit PAR-IST7-60/200

BATTERIES

## Battery charging and end-of-discharge protection

Charging in stages: current-limited charge, equalising, float, then an optional sleep phase that pauses charging and wakes up on voltage or time: less float time, longer battery life.

- Max. charge current 30 A on 60–120 kVA, 60 A on 160–200 kVA
- Charge current limit 0.2 C lead-acid, 0.5 C lithium (default)
- Optional timed equalising (default interval 720 h)
- Capacity setting 1–2000 Ah; string 28–48 × 12 V blocks
- End-of-discharge protection: two levels in V/cell plus a maximum discharge time (default 960 min) and an optional pre-alarm; float charge 2.27 V/cell, under-voltage protection 1.667 V/cell (inverter output off), level II protection 1.617 V/cell (UPS fully shut down)
- Battery test: standard (10 min) or deep test to the low-voltage alarm, started from the screen; runs only when the mains is normal, batteries are fully charged, the UPS has no fault and the load is at least 10%
- Temperature: with the optional probe, charge voltage is compensated (default 3 mV/°C/cell) and alarms trip at 50 °C and 0 °C (defaults)
- Best battery temperature 20–30 °C: below 20 °C backup time drops, above 30 °C battery life shortens
- Lithium ready: BMS card for battery communication plus charge-disable and discharge-disable inputs
- Three-pole battery string: split into two equal halves with the neutral at the midpoint, giving a positive and a negative DC bus from one set of 12 V blocks; battery breaker with three poles (+, N, −)
- Set on site from the display at commissioning: blocks per string (28–48), capacity in Ah and battery type; default ±192 V (32 blocks) on IST7-60/80, ±216 V (36 blocks) on IST7-100…200

BATTERY CABINETS

## BB5 to BB8, matched to every IST7

Steel cabinets for 12 V VRLA AGM batteries, supplied empty or complete with batteries, fuses and cables. Every configuration has its own AEC wiring diagram. Each cabinet holds one string with neutral at the midpoint; BB8 holds two strings in parallel.

- BB5: 460 × 800 × 1400 mm, 110 kg empty
- BB6: 800 × 800 × 1400 mm, 140 kg empty
- BB7: 800 × 800 × 1900 mm, 160 kg empty
- BB8: 1400 × 800 × 1900 mm, 250 kg empty
- UPS for comparison: IST7-60…120 400 × 960 × 1193 mm, 153–167 kg; IST7-160…200 600 × 1000 × 1600 mm, 294–296 kg
- Stored energy, max. layout (nominal: 12 V × Ah × batteries): BB5 18.2 kWh, BB6 25.9 kWh, BB7 43.2 kWh, BB8 76.8 kWh, 2 × BB8 153.6 kWh; backup time depends on load and battery data
- IST7-80 has the IST7-100 hardware; cabinet fuses are selected for the UPS model
- In every cabinet: 3-pole DC switch-disconnector Q1 with DC fuses; RAL 9005, IP20 (IP21–IP44 on request)
- Options: forced ventilation, Q1 auxiliary contact, internal and external cables
- [IEC/EN 62040-1](https://webstore.iec.ch/en/publication/80573) · [EN IEC 62485-2](https://webstore.iec.ch/en/publication/7091) · CE
- Wiring diagram, commissioning record and battery log supplied; 3-year warranty on the cabinet
- Order as one code: IST7-160-64X100 = IST7-160 + BB8 with 64 × 12 V 100 Ah · 294 kg + 2,215 kg

**BB5 to BB8, matched to every IST7**

| UPS | BB5 | BB6 | BB7 | BB8 | 2 × BB8 |
| --- | --- | --- | --- | --- | --- |
| IST7-60 | 30–38 × 40 Ah | 30–36 × 60 Ah | 30–36 × 80 / 100 Ah | 60 / 64 × 80 / 100 Ah | 120 / 128 × 80 / 100 Ah |
| IST7-80 · 100 · 120 | — | 30–36 × 60 Ah | 30–36 × 80 / 100 Ah | 60 / 64 × 80 / 100 Ah | 120 / 128 × 80 / 100 Ah |
| IST7-160 | — | — | 30–36 × 80 / 100 Ah | 60 / 64 × 80 / 100 Ah | 120 / 128 × 80 / 100 Ah |
| IST7-200 | — | — | — | 60 / 64 × 80 / 100 Ah | 120 / 128 × 80 / 100 Ah |

BATTERY CABINETS

## Battery connection by UPS model

Battery discharge current and recommended cable cross-section from the IST7 user manual; IST7-80 has the IST7-100 hardware. Cabinet fuses are selected for the UPS model.

**Battery connection by UPS model**

| UPS | I nom. (A) | I max. (A) | +/N/− mm² | PE mm² |
| --- | --- | --- | --- | --- |
| IST7-60 | 163 | 186 | 35 | 16 |
| IST7-80 | ≤ 241 | ≤ 279 | 50 | 35 |
| IST7-100 | 241 | 279 | 50 | 35 |
| IST7-120 | 289 | 372 | 70 | 35 |
| IST7-160 | 386 | 496 | 95 | 70 |
| IST7-200 | 482 | 558 | 95 | 70 |

CONNECTIVITY

## Every port on the bypass and control unit

All ports sit in one place on the bypass and control unit; every dry-contact input and output is assigned from the display.

- Bypass and control unit ports: battery cold start, SNMP card slot, RS485 parallel monitoring, dry contacts / EPO / battery temperature, parallel ports, expansion slot, control card LEDs, EPO2 input (NC), Modbus RTU and RS232, touch-screen port
- 4 inputs, 10 functions: battery abnormal, battery earthing abnormal, battery switch open, bypass switch open, output switch open, battery discharge disable, battery charge disable, generator mode, SPD abnormal, maintenance bypass start
- 3 changeover outputs (NO / NC), 18 functions: inverter output, bypass output, battery trip, on battery, battery low alarm, battery low protection, overload, UPS abnormal, bypass abnormal, mains abnormal, start generator, ECO output, inverter abnormal, single bypass feedback\*, parallel bypass feedback\*, UPS on, fan abnormal, UPS alarm (\* on request)
- Options: SNMP card (Ethernet, web pages, temperature/humidity sensor port); dry-contact expansion (+3 inputs, +2 outputs); BMS card (lithium battery communication); parallel kit PAR-IST7-60/200; battery temperature kit (probe and extension cable); surge protection (class C SPD with switch); battery release control (24 Vdc for shunt / UV release); lithium cabinets on request

AEC SERVICE

## Survey, installation, commissioning, maintenance

AEC engineers size, install, commission and maintain the IST7. The UPS keeps its own records, and AEC service works from them.

- 24/7 technical assistance by phone and WhatsApp, also on non-working days
- < 30 min WhatsApp reply to technical and commercial questions
- 3 years warranty, extendable with a maintenance contract
- 21+ countries with spare parts in stock across the Allis Electric group
- 01 Consulting and sizing: feasibility study and design for critical sites and data centres; UPS, battery and parallel system sized by the AEC engineering team (IST7: upgradable models, size for today, grow to 120 or 200 kVA)
- 02 Survey and installation: site survey, positioning and cabling of the UPS and battery cabinets by AEC technicians (IST7: cable entry from below on all models)
- 03 Commissioning: verification of every value and parameter, access levels and dry-contact functions (IST7: full-power self-load test without a load bank)
- 04 Maintenance: programmes and contracts written for each site, battery checks and replacement, generator tests (IST7: fan and capacitor service-life alarms; battery test from the screen)
- 05 Assistance 24/7: call centre 24 hours a day, 7 days a week, by phone and WhatsApp, with an engineer on site when needed (IST7: 10,000 events and wave capture exported to USB for analysis)
- 06 Expansion: capacity upgrades and new units in parallel, configured by AEC service (IST7: up to 8 units; parameter match and copy across units)
- Service data straight from the UPS: event history, wave capture, battery test records, USB export for the service report
- AEC Service: service@aecups.com · +39 393 080 5211 · www.aecups.com · Via Nerviano 55, 20045 Lainate (MI), Italy

### Ordering codes IST7 60–200

| Code | Description |
| --- | --- |
| `IST7-60` | 60 kVA / 60 kW |
| `IST7-80` | 80 kVA, upgradable to 100 or 120 kVA |
| `IST7-100` | 100 kVA, upgradable to 120 kVA |
| `IST7-120` | 120 kVA / 120 kW |
| `IST7-160` | 160 kVA, upgradable to 200 kVA |
| `IST7-200` | 200 kVA / 200 kW |
| `PAR-IST7-60/200` | Parallel kit |
| `IST7-\[kVA\]-\[n\]X\[Ah\]` | UPS with battery cabinet, n × 12 V \[Ah\] (e.g. IST7-160-64X100 = IST7-160 + BB8 with 64 × 12 V 100 Ah) |

Diagrams

## The IST7 60–200, in diagrams

The path of the power, the ratings, the footprints and the losses, drawn from the figures of the EMEA 2026 catalogue.

### How the power flows

Pick an operating mode: the path the power takes to the load lights up.

**Normal.** Double conversion: the rectifier feeds the DC bus, the inverter rebuilds a clean voltage and the load always runs on the inverter. The battery stays on charge. Efficiency up to 96.5% (peak AC/AC).

### The ratings

Every model in the range, in proportion to its power.

1. IST7-60 **60 kVA · 60 kW**
2. IST7-80 **80 kVA · 80 kW**
3. IST7-100 **100 kVA · 100 kW**
4. IST7-120 **120 kVA · 120 kW**
5. IST7-160 **160 kVA · 160 kW**
6. IST7-200 **200 kVA · 200 kW**

### Losses per 100 kW of load

Worked out as P × (1/η − 1) at the stated maximum efficiency, with the load steady all year. peak AC/AC.

1. Double conversion 96.5% **3.63 kW31,770 kWh/year**
2. ECO 99% **1.01 kW8,850 kWh/year**

### Phase configurations

Input / output: three-phase (3) or single-phase (1).

**3/3** 3~ → 3~

**In parallel** Up to 8 units on the same load, for redundancy or for more power.

### Footprints to scale

Front view of the cabinets, all at the same scale, beside a 2 m rule. W × D × H, mm.

- **60–120 kVA** 400 × 960 × 1,193 mm · 145–163 kg
- **160–200 kVA** 600 × 1,000 × 1,600 mm · 310–312 kg

Questions

## Questions people ask

#### Can an IST7 60–200 kVA be upgraded later?

Yes, selected models: the IST7-80 is upgraded to 100 or 120 kVA, the IST7-100 to 120 kVA and the IST7-160 to 200 kVA, by setting the capacity from the display. Hardware and footprint stay the same.

#### How many IST7 units can run in parallel?

Up to 8 units, for capacity or N+X redundancy, reaching 1.6 MW with 8 × IST7-200. BSC synchronisation supports dual-bus architectures, current sharing between units is within 5%, and the units can share a common battery bank.

#### How efficient is the IST7 60–200 kVA?

Peak AC/AC efficiency is 96.5% in online double conversion and 99% in ECO mode, with output power factor 1 (kVA = kW). At a 100 kW load, AEC's indicative calculation gives 3.6 kW of losses (≈ € 6,350 per year) in double conversion against 1.0 kW (≈ € 1,770) in ECO.

#### Which batteries does the IST7 60–200 kVA use?

A string of 28–48 × 12 V blocks set on site, VRLA or lithium with the BMS card: default ±192 V (32 blocks) on IST7-60/80 and ±216 V (36 blocks) on IST7-100…200. The maximum charge current is 30 A on 60–120 kVA and 60 A on 160–200 kVA, and AEC BB5 to BB8 cabinets are ordered with the UPS in one code.

#### What are the dimensions, weights and clearances?

The 60–120 kVA cabinet measures 400 × 960 × 1193 mm (153–167 kg) with bottom cable entry; the 160–200 kVA cabinet 600 × 1000 × 1600 mm (294–296 kg) with top cable entry. Leave at least 800 mm at the front, rear and above: cooling air enters at the front and leaves at the rear.

#### Which communication interfaces does it have?

RS485, Modbus RTU, RS232, EPO, USB and 4 dry-contact inputs / 3 outputs with assignable functions are standard. Options include an SNMP card with a temperature and humidity sensor port, dry-contact expansion (+3 inputs, +2 outputs) and a BMS card for lithium batteries.

#### What warranty and service come with the IST7 60–200 kVA?

A 3-year warranty, extendable with a maintenance contract, and 24/7 technical assistance by phone and WhatsApp. The UPS stores up to 10,000 events and wave captures that are exported to USB for the service report.

[All 22 questions](https://www.aecups.com/en/faq/ist7-60-200/)

In the same family: [All-in-One](https://www.aecups.com/en/products/all-in-one/) [IST9](https://www.aecups.com/en/products/ist9/) [IST7 10–40](https://www.aecups.com/en/products/ist7-10-40/) [IST7-T](https://www.aecups.com/en/products/ist7-t/) [Three-phase UPS](https://www.aecups.com/en/products/three-phase-ups/)

References

## Where is the IST7 60–200 installed?

[All projects](https://www.aecups.com/en/projects/)

[**An IST7 200 kW UPS for a Barilla pasta factory** Food production · Italy](https://www.aecups.com/en/projects/#barilla-ist7-200) [**An IST7 120 kW UPS for a plastics factory in the UK** Plastics factory · United Kingdom](https://www.aecups.com/en/projects/#uk-plastics-factory-ist7-120) [**2 MW of IST7, IST6 and IST8 UPS across Saudi Aramco's sites** Oil and gas · Saudi Arabia](https://www.aecups.com/en/projects/#aramco-ist7-ist6-ist8)

Guides

## Guides on the IST7 60–200

[All guides](https://www.aecups.com/en/blog/)

[**Battery room ventilation to EN IEC 62485-2 for VRLA** The EN IEC 62485-2 air flow for a VRLA battery, term by term, worked out for every AEC BB4–BB8 cabinet, with the size of the openings.](https://www.aecups.com/en/blog/battery-room-ventilation/) [**L6 lithium battery sizing: modules, cabinets, room** How AEC sizes an L6 lithium battery for an IST7 or IST6 UPS: power and energy counts, modules and cabinets for 10 to 30 minutes, floor and clearances.](https://www.aecups.com/en/blog/l6-lithium-battery-sizing/) [**UPS installation clearances: what to check on site** Clearances, operating gangways, door widths, floor load, cable entry and airflow for every AEC EMEA UPS and battery cabinet, before the delivery.](https://www.aecups.com/en/blog/ups-installation-clearances/)

Read next: [UPS heat output: BTU, cooling and room temperature](https://www.aecups.com/en/blog/ups-heat-output-cooling/) [Industrial UPS: protecting PLCs, motors and processes](https://www.aecups.com/en/blog/ups-for-industry/) [Three-phase UPS: configurations, sizing and installation](https://www.aecups.com/en/blog/three-phase-ups/)

## Talk to an AEC engineer

Tell us the load, the supply and the backup time you need for the AEC IST7 60–200 kVA: we answer with the model and the batteries that fit. AEC International sells through distributors in about 80 countries and an agency in every Italian region: ask AEC which one serves your area.

[Contact us](https://www.aecups.com/en/contacts/?interest=Three-phase%20UPS&msg=About%20the%20AEC%20IST7%2060%E2%80%93200%3A%20%0AQuantity%3A%20#form) [+39 02 9415 8991](tel:+390294158991)