title: "Three-phase online UPS 120 kVA, 400 V · IST7-120 | AEC"
url: https://www.aecups.com/en/products/ist7-60-200/ist7-120k/
description: "The IST7-120 is a 120 kVA / 120 kW three-phase online double-conversion UPS, the largest in the 400 mm cabinet, at 167 kg."
language: en
---

IST7 60–200 · Three-phase UPS

# IST7-120 Three-phase online UPS 120 kVA, 400 V

VRLA 120 kVA three-phase online UPS, 400 V

The IST7-120 is a 120 kVA / 120 kW three-phase online double-conversion UPS, the largest in the 400 mm cabinet, at 167 kg. For data rooms and industrial loads of 100 to 120 kW that need the most power per square metre of the IST7 range.

**120 kVA / 120 kW** Rating

**400 × 960 × 1193 mm** W × D × H

**167 kg** Weight

**±216 V** Battery

Technical data [Catalogue (PDF)](https://www.aecups.com/docs/AEC_UPS_Catalogue_EMEA_2026.pdf#page=80) [Contact us](https://www.aecups.com/en/contacts/?interest=Three-phase%20UPS&msg=About%20the%20AEC%20IST7-120%20(IST7%2060%E2%80%93200)%3A%20%0AQuantity%3A%20#form)

[**Try 3D** X-ray view](https://www.aecups.com/assets/models3d/ist7-120/v65/)

Quick answers

## IST7-120: quick answers

**What it is**: The IST7-120 is a 120 kVA / 120 kW three-phase online double-conversion UPS, the largest in the 400 mm cabinet, at 167 kg.

**Who it is for**: For data rooms and industrial loads of 100 to 120 kW that need the most power per square metre of the IST7 range.

**Supply and configuration**: 3 phases + N + PE · 220 / 230 / 240 V L-N · 380 / 400 / 415 V L-L

**Battery and backup**: ±216 V

**Size and weight**: 400 × 960 × 1193 mm · 167 kg

**Ordering code**: IST7-120

IST7 60–200

## What sets apart the IST7-120

The IST7-120 puts 120 kW in the same 400 × 960 × 1193 mm cabinet as the IST7-60. The price of that density is the overload table: where the other models carry 150% for one minute, the IST7-120 goes to immediate protection above 125% (105% continuous, 110% for 60 minutes, 125% for 10 minutes). Leave spare capacity when loads have high inrush.

On battery it draws 289 A nominal and 372 A maximum, on 70 mm² cables (PE 35 mm²), from a default ±216 V string. The static bypass still carries 300% for 100 ms to clear faults downstream.

- **Against the IST7-100** (one size down): Rated power 120 kVA / 120 kW against 100 kVA / 100 kW; Weight 167 kg against 165 kg.
- **Against the IST7-160** (one size up): Rated power 120 kVA / 120 kW against 160 kVA / 160 kW; Max. charge current 30 A against 60 A; Dimensions W × D × H 400 × 960 × 1193 mm against 600 × 1000 × 1600 mm; Weight 167 kg against 294 kg.

Planning data

## IST7-120: currents, breakers, cables, batteries

The rows and columns of the EMEA 2026 catalogue's and AEC manuals' tables that concern the IST7-120.

### Front, rear and footprint

**IST7-120 · Front, rear and footprint**

| Model | W × D × H (mm) | Weight |
| --- | --- | --- |
| IST7-120 | 400 × 960 × 1193 | 167 kg |

### BB5 to BB8, matched to every IST7

**IST7-120 · BB5 to BB8, matched to every IST7**

| UPS | IST7-80 · 100 · 120 |
| --- | --- |
| BB5 | — |
| BB6 | 30–36 × 60 Ah |
| BB7 | 30–36 × 80 / 100 Ah |
| BB8 | 60 / 64 × 80 / 100 Ah |
| 2 × BB8 | 120 / 128 × 80 / 100 Ah |

### Battery connection by UPS model

**IST7-120 · Battery connection by UPS model**

| UPS | IST7-120 |
| --- | --- |
| I nom. (A) | 289 |
| I max. (A) | 372 |
| +/N/− mm² | 70 |
| PE mm² | 35 |

Installation

## Installing the IST7-120: space, heat, cables

Each figure with its source. Heat is the power lost at the peak efficiency stated.

**IST7-120 · installation**

| Item | Figure | Source |
| --- | --- | --- |
| Clearances | front 800 mm, rear 800 mm, left 800 mm, right 800 mm, top 800 mm | AEC IST7 60–200 user manual p.35 §3.2.3 |
| Cable entry | Bottom, through the base | AEC IST7 60–200 user manual |
| Heat at full load | 4.35 kW at 120 kW load, 96.5 % efficiency | AEC IST7 60–200 user manual p.87 §A; output PF 1 (EMEA 2026 catalogue) |
| Operating temperature | −5 to 40 °C, best 20–30 °C | AEC IST7 60–200 user manual p.34–35 §3.2.2 |
| Switches and terminals | Mains, bypass, output and maintenance bypass switches behind the lockable front door; terminals behind the front and rear wiring covers. | AEC IST7 60–200 user manual p.13 Fig. 2-2/2-3 (handle on the left edge) |
| Door | One leaf, hinged on the right | AEC IST7 60–200 user manual p.13 Fig. 2-2/2-3 (handle on the left edge) |

Size and floor

## How big it is

400 × 960 × 1193 mm · 167 kg.

**0.38 m²** footprint

**435 kg/m²** floor load

**1.19 m** height

Floor load = weight ÷ footprint (167 kg).

Efficiency

## How efficient is the AEC IST7-120 at your load?

IST7-120, 120 kW at its rating, online, double conversion (typical curve, AEC's method). Heat to remove on this curve: 25%: 1.28 kW (η 95.9%) · 50%: 2.18 kW (η 96.5%) · 75%: 3.56 kW (η 96.2%) · 100%: 5.13 kW (η 95.9%). At 50% load, 24/7, it loses about 19,063 kWh a year.

**96.5** % 50% · Typical curve, derived from the datasheet efficiency of 96.5% (AEC method)

How the curve is drawn and where each figure comes from: [the IST7 60–200 range page](https://www.aecups.com/en/products/ist7-60-200/#efficiency).

**Load**: —

**Lost as heat**: —

**Energy lost in a year, 24/7**: —

**Its cost in a year at € per kWh**: —

The catalogue's examples use €0.20 per kWh.

#### Where each figure comes from

| Mode | Efficiency | Kind | Models | Source |
| --- | --- | --- | --- | --- |
| Online, double conversion | 25%: 95.9% · 50%: 96.5% · 75%: 96.2% · 100%: 95.9% | Typical curve, derived from the datasheet efficiency of 96.5% (AEC method) | all | AEC datasheet: AC/AC efficiency of the IST6-PM100 100 kW power module (the curve's shape) |
| ECO | 99% | Datasheet figure, load not stated | all |  |

EMEA 2026 catalogue figures: Online, double conversion up to 96.5% · ECO up to 99%.

Drag to turn

In 3D

## Look around the IST7-120

[Open full 3D · X-ray](https://www.aecups.com/assets/models3d/ist7-120/v65/)

Technical data

## Technical data IST7-120

Only this model's values, from the EMEA 2026 catalogue table.

**IST7-120 · Technical data**

|  |  |
| --- | --- |
| General |  |
| Rated power (kVA / kW) | 120 |
| Input |  |
| Connection | 3 phases + N + PE |
| Rated voltage | 220 / 230 / 240 V phase (380 / 400 / 415 V line) |
| Voltage range | 187–280 V phase at full power · 80–186 V with linear derating |
| Frequency · power factor · THDi | 40–70 Hz · ≥ 0.99 · ≤ 3% at full load |
| Bypass synchronisation range | 50 / 60 Hz ± 6 Hz |
| Battery |  |
| Nominal DC voltage (default) | ±216 V |
| String length | 28–48 × 12 V blocks, set on site · VRLA or lithium (BMS card) |
| Max. charge current | 30 A |
| Output |  |
| Voltage · frequency | 220 / 230 / 240 V phase · 50 / 60 Hz (± 0.1 Hz on battery) |
| Power factor · THDv | 1 (settable 0.9) · ≤ 1% linear, ≤ 4% non-linear load |
| Transient · unbalance · phase error | ≤ 5% for 0–100–0% step · 100% unbalanced load · ≤ 1° |
| Transfer time inverter ↔ bypass | < 1 ms synchronised · < 15 ms not synchronised |
| Inverter overload | ≤ 105% continuous · ≤ 110% 60 min · ≤ 125% 10 min · ≤ 150% 1 min (IST7-120: > 125% immediate) |
| Bypass overload | ≤ 130% continuous · ≤ 150% 5 min · ≤ 200% 1 s · ≤ 300% 100 ms |
| System |  |
| Efficiency AC/AC | up to 96.5% double conversion · 99% ECO mode |
| Parallel | Up to 8 units, capacity or N+X · BSC dual-bus synchronisation |
| Communication | RS485 · Modbus RTU · RS232 · 4 IN / 3 OUT dry contacts · EPO · SNMP slot · expansion slot |
| Display | Colour touch screen, 5 status LEDs, ambient light bar, 10,000 events and 10,000 user-log entries |
| Environment | −5 … 40 °C · 0–95% RH · IP20 · < 65 dB at 1 m · forced-air cooling |
| Cable entry | bottom (all models) |
| EMC | [IEC 62040-2](https://webstore.iec.ch/en/publication/33696):2016 · category C3 (not for residential use without additional measures) |
| Dimensions W × D × H | 400 × 960 × 1193 mm |
| Weight | 167 kg |

**IST7-120 · Models**

| Item | IST7-120 |
| --- | --- |
| Rated power (kVA / kW) | 120 |
| Capacity upgrade | — |
| Power units | 1 |
| Nominal DC voltage (default) | ±216 V |
| Max. charge current | 30 A |
| W × D × H (mm) | 400 × 960 × 1193 |
| Weight | 167 kg |

Specifications are subject to change without notice.

#### **More technical details** ordering codes

Ordering codes

## Ordering codes IST7-120

**Ordering codes IST7-120**

| Code | Description |
| --- | --- |
| IST7-120 | 120 kVA / 120 kW |
| PAR-IST7-60/200 | Parallel kit |
| IST7-\[kVA\]-\[n\]X\[Ah\] | UPS with battery cabinet, n × 12 V \[Ah\] (e.g. IST7-160-64X100 = IST7-160 + BB8 with 64 × 12 V 100 Ah) |

Questions

## Questions about the IST7-120

#### What overload does the IST7-120 accept?

On the inverter: 105% continuous, 110% for 60 minutes, 125% for 10 minutes, then immediate protection above 125%. The static bypass carries 130% continuous, 150% for 5 minutes, 200% for 1 s and 300% for 100 ms.

#### IST7-120 or an upgraded IST7-80 / IST7-100?

All three end at 120 kVA in the same cabinet. Buy the IST7-120 when the load is already there; buy the IST7-80 or IST7-100 when it will grow, and raise the capacity from the display later.

#### How long does a 120 kVA UPS like the IST7-120 run?

1 to 39 minutes at full load (120 kW), and 4 to 98 minutes at half load, with the AEC battery options in the table: the battery chosen sets the figure. With 30 × 12 V 60 Ah (IST7-120-30X60): 1 minutes at 100% and 4 at 50%. For other loads and batteries use the backup-time tool.

#### How big is the AEC IST7-120 and how much does it weigh?

The AEC IST7-120 measures 400 × 960 × 1193 mm; weight: 167 kg (size from AEC's CAD drawing, weight from the EMEA 2026 catalogue).

#### What is the ordering code of the AEC IST7-120?

In the EMEA 2026 catalogue the AEC IST7-120 is listed as IST7-120; AEC gives the full code, batteries included, from the load and the backup time.

Related models

## The same range: IST7 60–200

[The whole range](https://www.aecups.com/en/products/ist7-60-200/)

[**IST7-60** 60 kVA](https://www.aecups.com/en/products/ist7-60-200/ist7-60k/) [**IST7-80** 80 kVA](https://www.aecups.com/en/products/ist7-60-200/ist7-80k/) [**IST7-100** 100 kVA · smaller rating](https://www.aecups.com/en/products/ist7-60-200/ist7-100k/) **IST7-120** 120 kVA [**IST7-160** 160 kVA · larger rating](https://www.aecups.com/en/products/ist7-60-200/ist7-160k/) [**IST7-200** 200 kVA](https://www.aecups.com/en/products/ist7-60-200/ist7-200k/)

Batteries and cabinets: [BB6](https://www.aecups.com/en/products/battery-cabinets/bb6/) [BB7](https://www.aecups.com/en/products/battery-cabinets/bb7/) [BB8](https://www.aecups.com/en/products/battery-cabinets/bb8/) [OZ Power 12 V 80 Ah](https://www.aecups.com/en/products/oz-power-vrla/oz-12v-80ah/) [OZ Power 12 V 100 Ah](https://www.aecups.com/en/products/oz-power-vrla/oz-12v-100ah/) [L6 Lithium](https://www.aecups.com/en/products/l6-lithium/) Accessories: [SNMP card](https://www.aecups.com/en/products/snmp-card/) [Dry contact card](https://www.aecups.com/en/products/dry-contact-card/)

Shared by the whole range, on the IST7 60–200 page: [the display simulator](https://www.aecups.com/en/products/ist7-60-200/#display) · [how the power flows in each mode](https://www.aecups.com/en/products/ist7-60-200/#diagrams) · [the catalogue's photos and drawings](https://www.aecups.com/en/products/ist7-60-200/#gallery).

Read next: [UPS installation clearances: what to check on site](https://www.aecups.com/en/blog/ups-installation-clearances/) [UPS heat output: BTU, cooling and room temperature](https://www.aecups.com/en/blog/ups-heat-output-cooling/) [L6 lithium battery sizing: modules, cabinets, room](https://www.aecups.com/en/blog/l6-lithium-battery-sizing/)