title: "Single-phase lithium UPS 2 kVA, rack 2U · IST8-2 | AEC"
url: https://www.aecups.com/en/products/ist8/ist8-2k/
description: "The IST8-2 is a 2 kVA / 2 kW single-phase online double-conversion UPS with a built-in lithium-ion battery, in 2U and 570 mm of depth."
language: en
---

IST8 · Single-phase UPS

# IST8-2 Single-phase lithium UPS 2 kVA, rack 2U

Lithium 2 kVA online UPS, lithium, 2U

The IST8-2 is a 2 kVA / 2 kW single-phase online double-conversion UPS with a built-in lithium-ion battery, in 2U and 570 mm of depth. For server and network racks of up to 2 kW where the battery should last without the lead-acid replacement cycle.

**2 kVA / 2 kW** Rating

**438 × 570 × 87 mm (2U)** W × D × H

**13.6 kg** Weight

Technical data [Catalogue (PDF)](https://www.aecups.com/docs/AEC_UPS_Catalogue_EMEA_2026.pdf#page=34) [Contact us](https://www.aecups.com/en/contacts/?interest=Single-phase%20UPS&msg=About%20the%20AEC%20IST8-2%20(IST8)%3A%20%0AQuantity%3A%20#form)

[**Try 3D** X-ray view](https://www.aecups.com/assets/models3d/ist8-2/v60/)

Quick answers

## IST8-2: quick answers

**What it is**: The IST8-2 is a 2 kVA / 2 kW single-phase online double-conversion UPS with a built-in lithium-ion battery, in 2U and 570 mm of depth.

**Who it is for**: For server and network racks of up to 2 kW where the battery should last without the lead-acid replacement cycle.

**Supply and configuration**: 208 / 220 / 230 / 240 V

**Battery and backup**: lithium iron phosphate (LFP), built in · 11 min · 4 A

**Size and weight**: 438 × 570 × 87 mm (2U) · 13.6 kg

**Ordering code**: IST8-2

IST8

## What sets apart the IST8-2

The IST8-2 moves to the 570 mm chassis, weighs 13.6 kg and takes an IEC C20 inlet, with six C13 outlets plus one C19 for a 16 A load. With an output power factor of 1 its 2000 VA are 2000 W.

Efficiency is 91.5% AC/AC, as on the 1 kVA. Two fans cool it, and the noise stays below 55 dB. The display reads RCK in a rack or TWR standing as a tower, set from the panel.

- **Against the IST8-1** (one size down): Power 2000 VA / 2000 W against 1000 VA / 1000 W; Input socket IEC C20 against IEC C14; Output sockets 6 × IEC C13 + 1 × IEC C19 against 6 × IEC C13; Dimensions W × D × H (mm) 438 × 570 × 87 (2U) against 438 × 423 × 86 (2U); Weight 13.6 kg against 8.9 kg.
- **Against the IST8-3** (one size up): Power 2000 VA / 2000 W against 3000 VA / 3000 W; AC/AC efficiency 91.5% against 93%; Weight 13.6 kg against 16.1 kg.

Installation

## Installing the IST8-2: space, heat, cables

Each figure with its source. Heat is the power lost at the peak efficiency stated.

**IST8-2 · installation**

| Item | Figure | Source |
| --- | --- | --- |
| Clearances | rear 300 mm (recommended 500), left 300 mm (recommended 500), right 300 mm (recommended 500), top 500 mm; front: not given | IST8 user manual p.11–12, 19; EMEA 2026 catalogue p.41; IST8 user manual p.11–12; IST8 user manual p.19 |
| Cable entry | Plugs and sockets at the rear | IST8 user manual p.11–12, 19; EMEA 2026 catalogue p.41 |
| Heat at full load | 0.17 kW at 1.8 kW load, 91.5 % efficiency | EMEA 2026 catalogue p.39, 44 (IST8 1–2 kVA; 3 kVA 93 %) |
| Operating temperature | 0 to 40 °C | EMEA 2026 catalogue p.38, 44: lithium 0–60 °C, best 0–40 °C |
| Switches and terminals | Sockets and connections on the rear panel; lithium battery built in. | IST8 user manual p.11–12, 19; EMEA 2026 catalogue p.41 |

Size and floor

## How big it is

438 × 570 × 87 mm · 13.6 kg.

**0.25 m²** footprint

**54 kg/m²** floor load

**0.09 m** height

Floor load = weight ÷ footprint (13.6 kg).

Backup time

## How long does the AEC IST8-2 run at your load?

AEC's backup times for every ordering code: the minutes AEC publishes from 50 to 100% load, AEC's calculator below 50% and for a string you compose. Pick a battery option: the curve redraws, and every point says where it comes from.

Load50% · 1 kW

Loading AEC's data…

Source: AEC EMEA product data: ordering codes, cabinets, blocks and strings, and the times AEC publishes from 50 to 100% load. Below 50%, AEC's calculator (W per cell = load ÷ 96% ÷ cells, read on a straight line between the columns of the battery maker's constant-power table at 1.70 V/cell), scaled to meet the published 50% figure. Lithium: published times only. New batteries, 25 °C. AEC checks every sizing. The catalogue prints 11 minutes without the load it is measured at; AEC's own data (EU portal) gives 12 minutes at full load for all three ratings, and the minutes from 50 to 100 % load shown here.

#### Table: the IST8-2 minutes at 20, 50, 80 and 100% load

**IST8-2: backup time in minutes at the load shown (100% = 2 kW)**

| Batteries | Code | 20% | 50% | 80% | 100% |
| --- | --- | --- | --- | --- | --- |
| built-in lithium battery | `IST8-2-Li` | — | 42 | 20 | 12 |

For each battery type the smallest and the largest configuration; new batteries, 25 °C. AEC published figures. Every option is in the chart and the table of codes.

#### All 1 ordering codes of the IST8-2 and their backup times

**IST8-2: ordering codes and backup time in minutes at the load shown**

| Code | Batteries | Cabinet | 100% | 90% | 80% | 70% | 60% | 50% |
| --- | --- | --- | --- | --- | --- | --- | --- | --- |
| Built-in lithium battery |  |  |  |  |  |  |  |  |
| IST8-2-Li | built-in lithium battery | internal | 12 | 15 | 20 | 26 | 33 | 42 |

Minutes from AEC EMEA product data: from 50 to 100% load, the times AEC publishes. The chart above adds AEC's calculation from 10 to 40%.

Drag to turn

In 3D

## Look around the IST8-2

[Open full 3D · X-ray](https://www.aecups.com/assets/models3d/ist8-2/v60/)

Technical data

## Technical data IST8-2

Only this model's values, from the EMEA 2026 catalogue table.

**IST8-2 · Technical data**

|  |  |
| --- | --- |
| Rating |  |
| Power (VA / W) | 2000 / 2000 |
| Input |  |
| Voltage range | 120–295 V AC |
| Frequency | 50 / 60 Hz ± 10%, auto-sensing |
| Power factor · THDi | ≥ 0.99 · < 5% |
| Input socket | IEC C20 |
| Output |  |
| Voltage | 208 / 220 / 230 / 240 V ± 1%, settable from the panel |
| Frequency (battery mode) | 50 / 60 Hz ± 0.1 Hz |
| Power factor · voltage distortion | 1 · THDv < 3% |
| Transfer time | 0 ms |
| AC/AC efficiency | 91.5% |
| Overload | 101–115% 1 min · 116–133% 1 s · > 134% 200 ms |
| Output sockets | 6 × IEC C13 + 1 × IEC C19 |
| Battery |  |
| Type | lithium iron phosphate (LFP), built in |
| Backup time · max. charging current | 11 min · 4 A |
| General |  |
| Operating modes | online (INV) · ECO, set from the panel |
| Display | LCD, rack (RCK) or tower (TWR) reading |
| Communication | USB · intelligent slot (DB9, RS232 + dry contact as shown; optional SNMP card or RS485 + dry-contact card) · EPO |
| Protections | output over-voltage, battery under-voltage, input over-voltage, overload, short circuit, over-temperature |
| Noise | < 55 dB |
| Environment | 0–60 °C (best 0–40 °C; long periods at 40–60 °C may reduce the output power) · 0–95% RH non-condensing |
| Dimensions W × D × H (mm) | 438 × 570 × 87 (2U) |
| Weight (kg) | 13.6 |

**IST8-2 · Models**

| Item | IST8-2 |
| --- | --- |
| Power VA / W | 2000 / 2000 |
| W × D × H (mm) | 438 × 570 × 87 (2U) |
| Weight (kg) | 13.6 |
| AC/AC efficiency | 91.5% |
| Outlets | 6 × IEC C13 + 1 × IEC C19 |
| Inlet | IEC C20 |

230 V models. Specifications are subject to change without notice.

#### **More technical details** ordering codes

Ordering codes

## Ordering codes IST8-2

**Ordering codes IST8-2**

| Code | Description |
| --- | --- |
| IST8-2 | Online UPS 2 kVA, rack / tower, built-in lithium-ion battery |
| SNMP | Internal SNMP card |

Questions

## Questions about the IST8-2

#### Which outlets does the IST8-2 have?

Six IEC C13 and one IEC C19 at the output, and an IEC C20 inlet. The catalogue advises against inductive or half-wave rectified loads such as motors, air conditioners or fluorescent lamps.

#### Can the IST8-2 be monitored over the network?

Yes, with the optional SNMP card in the intelligent slot: input and output voltage and frequency, load and remote ON / OFF. USB with the power management software is standard; an RS485 + dry-contact card is the other option.

#### How long does a 2 kVA UPS like the IST8-2 run?

12 minutes at full load (2 kW), and 42 minutes at half load, with the AEC battery options in the table: the battery chosen sets the figure. With built-in lithium battery (IST8-2-Li): 12 minutes at 100% and 42 at 50%. For other loads and batteries use the backup-time tool.

#### How big is the AEC IST8-2 and how much does it weigh?

The AEC IST8-2 measures 438 × 570 × 87 mm (2U); weight: 13.6 kg (EMEA 2026 catalogue).

#### What is the ordering code of the AEC IST8-2?

In the EMEA 2026 catalogue the AEC IST8-2 is listed as IST8-2; AEC gives the full code, batteries included, from the load and the backup time.

Related models

## The same range: IST8

[The whole range](https://www.aecups.com/en/products/ist8/)

[**IST8-1** 1 kVA · smaller rating](https://www.aecups.com/en/products/ist8/ist8-1k/) **IST8-2** 2 kVA [**IST8-3** 3 kVA · larger rating](https://www.aecups.com/en/products/ist8/ist8-3k/)

Accessories: [SNMP card](https://www.aecups.com/en/products/snmp-card/) [Dry contact card](https://www.aecups.com/en/products/dry-contact-card/)

Shared by the whole range, on the IST8 page: [the display simulator](https://www.aecups.com/en/products/ist8/#display) · [how the power flows in each mode](https://www.aecups.com/en/products/ist8/#diagrams) · [the catalogue's photos and drawings](https://www.aecups.com/en/products/ist8/#gallery).

Read next: [kVA vs kW: power factor and UPS sizing explained](https://www.aecups.com/en/blog/kva-vs-kw/) [UPS for blackouts and storms: what to know](https://www.aecups.com/en/blog/ups-for-blackouts/) [UPS for home: protect devices, router and data](https://www.aecups.com/en/blog/ups-for-home/)

## Talk to an AEC engineer

Tell us the load, the supply and the backup time you need for the AEC IST8-2: we answer with the model and the batteries that fit. AEC International sells through distributors in about 80 countries and an agency in every Italian region: ask AEC which one serves your area.

[Contact us](https://www.aecups.com/en/contacts/?interest=Single-phase%20UPS&msg=About%20the%20AEC%20IST8-2%20(IST8)%3A%20%0AQuantity%3A%20#form) [+39 02 9415 8991](tel:+390294158991)