title: "Single-phase UPS, 230 V, online, 1 to 10 kVA | AEC"
url: https://www.aecups.com/en/products/single-phase-ups/
description: "AEC single-phase UPS for 230 V, 1 to 10 kVA: IST3 tower, IST3-J 2U rack/tower and IST8 with a built-in lithium battery."
language: en
---

230 V · 1 to 10 kVA

# Single-phase UPS, 230 V, 1 to 10 kVA

A single-phase UPS protects 230 V loads: workstations, servers, network equipment, tills and small panels. AEC has three online double-conversion ranges from 1 to 10 kVA: the IST3 tower with internal batteries, the IST3-J rack/tower, 2U high, and the IST8 rack/tower from 1 to 3 kVA with a built-in lithium battery.

## Which range fits your load?

### IST3

VRLA

1–10 kVA

Online UPS, double conversion, tower, 1–10 kVA

Details

### IST3-J

VRLA

1–10 kVA

Online UPS, rack / tower, 2U, 1–10 kVA

Details

### IST8

Lithium

1–3 kVA

Online UPS, lithium, rack / tower, 1–3 kVA

Details

Models

## One model, one page

Every rating has its own page: that model's technical data, ordering codes, batteries and the questions people ask.

**[IST3](https://www.aecups.com/en/products/ist3/)** 1–10 kVA [IST3-1](https://www.aecups.com/en/products/ist3/ist3-1k/) · [IST3-2](https://www.aecups.com/en/products/ist3/ist3-2k/) · [IST3-3](https://www.aecups.com/en/products/ist3/ist3-3k/) · [IST3-6](https://www.aecups.com/en/products/ist3/ist3-6k/) · [IST3-10](https://www.aecups.com/en/products/ist3/ist3-10k/)

**[IST3-J](https://www.aecups.com/en/products/ist3-j/)** 1–10 kVA [IST3-J 1 kVA](https://www.aecups.com/en/products/ist3-j/ist3j-1k/) · [IST3-J 2 kVA](https://www.aecups.com/en/products/ist3-j/ist3j-2k/) · [IST3-J 3 kVA](https://www.aecups.com/en/products/ist3-j/ist3j-3k/) · [IST3-J 6 kVA](https://www.aecups.com/en/products/ist3-j/ist3j-6k/) · [IST3-J 10 kVA](https://www.aecups.com/en/products/ist3-j/ist3j-10k/)

**[IST8](https://www.aecups.com/en/products/ist8/)** 1–3 kVA [IST8-1](https://www.aecups.com/en/products/ist8/ist8-1k/) · [IST8-2](https://www.aecups.com/en/products/ist8/ist8-2k/) · [IST8-3](https://www.aecups.com/en/products/ist8/ist8-3k/)

Comparison

## Single-phase UPS: how do the ranges compare?

| Range | Ratings | Voltage | Description | Batteries |
| --- | --- | --- | --- | --- |
| [IST3](https://www.aecups.com/en/products/ist3/) | 1–10 kVA | 208 / 220 / 230 / 240 V | Online UPS, double conversion, tower, 1–10 kVA | VRLA |
| [IST3-J](https://www.aecups.com/en/products/ist3-j/) | 1–10 kVA | 208 / 220 / 230 / 240 V | Online UPS, rack / tower, 2U, 1–10 kVA | VRLA |
| [IST8](https://www.aecups.com/en/products/ist8/) | 1–3 kVA | 208 / 220 / 230 / 240 V | Online UPS, lithium, rack / tower, 1–3 kVA | Lithium |

Questions

## Questions people ask

#### What is the difference between the IST3, IST3-J and IST8?

All three are single-phase online double-conversion UPS with 0 ms transfer. The IST3 is a tower from 1 to 10 kVA, standard or long backup; the IST3-J is a 2U 19-inch rack unit from 1 to 10 kVA (tower too on 1–3 kVA); the IST8 is a 2U rack / tower unit from 1 to 3 kVA with a built-in lithium-ion battery.

#### Which single-phase UPS gives the longest backup with internal batteries?

At 1–3 kVA, the IST8 gives 11 minutes with its lithium battery, while the IST3 and IST3-J standard models give 3 minutes at full load. The IST3 6 and 10 kVA give 5 / 20 and 1 / 15 minutes at full / half load; the IST3-J 6–10 kVA and all long backup models depend on external batteries.

#### How much real power in watts does each range deliver?

The IST8 has output power factor 1, so its 3 kVA delivers 3000 W. The IST3 and IST3-J have output power factor 1 too: the 3 kVA delivers 3000 W and the 10 kVA 10,000 W.

#### Lead-acid or lithium: what battery life can I expect?

The IST3 and IST3-J standard models have internal 12 V 9 Ah batteries, with a typical life of 3–5 years on the IST3 depending on temperature and use. The IST8 lithium-ion battery offers up to 8 years of service life and up to 1000 charge / discharge cycles.

#### Which single-phase UPS fits a 19-inch rack, and which can run in parallel?

The IST3-J and IST8 are 2U, 438 mm wide units for 19-inch racks, while the IST3 is a tower. Only the IST3-J 10 kVA /B version can be used in parallel.

Guides

## Guides: Single-phase UPS

[All guides](https://www.aecups.com/en/blog/)

[**How to choose a UPS: type, runtime, phases and service** How to choose a UPS once its size is known: online or line-interactive, runtime and shutdown, single- or three-phase, rack or tower, and service.](https://www.aecups.com/en/blog/how-to-choose-a-ups/) [**Single- or three-phase UPS: which does your site need?** Single-phase or three-phase UPS? Where the line falls in kVA and amps, what the supply and the loads decide, a 12 kW worked example and a checklist.](https://www.aecups.com/en/blog/single-vs-three-phase-ups/) [**UPS sizing: how to work out the power you need** How to size a UPS: list the loads, convert watts to VA, keep 20% headroom in both VA and W, then pick the battery. Two worked examples and a checklist.](https://www.aecups.com/en/blog/ups-sizing/)

## Talk to an AEC engineer

Tell us the load, the supply and the backup time you need: we answer with the model and the batteries that fit.