---
title: "UPS accessories · Communication cards and bypass | AEC"
url: https://www.aecups.com/en/products/ups-accessories/
description: "SNMP, dry-contact and USB cards, and the external maintenance bypass. The bypass lets the UPS be serviced without interrupting the load."
language: en
---

Communication cards and bypass

# UPS accessories

SNMP, dry-contact and USB cards, and the external maintenance bypass. The SNMP card monitors and operates the UPS from its own web page; the dry-contact card signals its states on potential-free contacts and can shut it down remotely; the USB card connects it to a computer. The bypass lets the UPS be serviced without interrupting the load.

## Which range fits your load?

### SNMP card

Monitor, test and operate AEC UPS from anywhere on the network.

Details

### Dry contact card

Potential-free contacts that signal UPS states, and remote shutdown.

Details

### USB card

Connect the UPS to a computer through a USB port.

Details

### External maintenance bypass

Service, repair or replace the UPS without switching off the load.

Details

Compatibility

## Which card fits which range?

The communication ports and cards of each UPS range, from the AEC Catalogue EMEA 2026. “—”: the catalogue does not list it for that range.

| Range | SNMP | Dry contact / RS485 | USB |
| --- | --- | --- | --- |
| [IST3](https://www.aecups.com/en/products/ist3/) | optional | optional | standard |
| [IST3-J](https://www.aecups.com/en/products/ist3-j/) | optional | optional | standard, 1–3 kVA |
| [IST8](https://www.aecups.com/en/products/ist8/) | optional | standard, optional | standard |
| [All-in-One](https://www.aecups.com/en/products/all-in-one/) | optional | optional | — |
| [IST9](https://www.aecups.com/en/products/ist9/) | optional | optional | — |
| [IST7 10–40](https://www.aecups.com/en/products/ist7-10-40/) | optional | standard, optional | — |
| [IST7 60–200](https://www.aecups.com/en/products/ist7-60-200/) | optional | standard, optional | — |
| [IST7-T](https://www.aecups.com/en/products/ist7-t/) | optional | standard | — |
| [IST6-120](https://www.aecups.com/en/products/ist6-120/) | optional | standard, optional | — |
| [IST6 200–500](https://www.aecups.com/en/products/ist6-200-500/) | optional | standard, optional | — |
| [IST6 400–1200](https://www.aecups.com/en/products/ist6-400-1200/) | optional | standard, optional | — |
| [CPSS 1–10](https://www.aecups.com/en/products/cpss-1-10/) | optional | optional | standard |
| [CPSS 10–200](https://www.aecups.com/en/products/cpss-10-200/) | — | — | — |

Questions

## Questions people ask

#### Which card monitors a UPS over the network?

The SNMP card: it puts the UPS on the LAN with its own web page, for monitoring, alarms and remote shutdown. The table on this page shows which ranges take it, as standard or as an option.

#### What is a dry-contact card for?

It gives potential-free relay contacts, normally open or normally closed, that signal UPS states such as mains failure or low battery to an alarm panel or a building management system, and it allows a manual or automatic remote shutdown.

#### When is an external maintenance bypass needed?

When the UPS must be serviced, repaired or replaced without switching off the load: the bypass takes the UPS terminals out of voltage while the load stays supplied. The MBYP-3K serves UPS up to 3 kVA, the MBYP-6K up to 10 kVA.

Guides

## Guides: UPS accessories

[All guides](https://www.aecups.com/en/blog/)

[**UPS datasheet explained: every line, with examples** How to read a UPS datasheet: UPS specifications explained section by section, from input and battery to efficiency, using a real AEC datasheet.](https://www.aecups.com/en/blog/how-to-read-a-ups-datasheet/)

## Talk to an AEC engineer

Tell us the load, the supply and the backup time you need: we answer with the model and the batteries that fit.

[Contact us](https://www.aecups.com/en/contacts/#form) [+39 02 9415 8991](tel:+390294158991)
