---
title: "UPS replacement: the AEC model for the same load"
url: https://www.aecups.com/en/tools/ups-replacement/
description: "Type the model of your UPS: the AEC model for the same load, matched by phases, rating and topology. 693 models of 7 makers, from their own datasheets."
language: en
---

Tools

# Replacing another maker's UPS?

Type the model on the label: the AEC model of the same rating and phases comes up, with its page. The search knows 693 models of 7 makers, APC (Schneider Electric), Riello UPS, Salicru and more, each read from its maker's own datasheet.

**693** models matched

**7** makers

**101** families

**10** AEC ranges

Data from each maker's own published datasheets and product pages, November 2026. Other makers' names and model numbers are their owners' trademarks, named only to identify the models; AEC is not affiliated with them.

Datasheets side by side: [AEC and the other makers](https://www.aecups.com/en/comparisons/)

How a match is made

## Same supply, at least the same rating

Each model is read from its maker's own datasheet or product page: the rating in kVA and kW, the phases in and out, the voltage, the topology and the battery. The AEC model is the one on the same supply:

- **230 V single-phase**: 338 models, 0.4–20 kVA → [AEC IST3](https://www.aecups.com/en/products/ist3/) (166), [AEC IST3-J](https://www.aecups.com/en/products/ist3-j/) (152), [AEC IST8](https://www.aecups.com/en/products/ist8/) (16) and [AEC IST7 10–40](https://www.aecups.com/en/products/ist7-10-40/) (4)
- **400 V three-phase**: 297 models, 7.5–1,200 kVA → [AEC IST7 10–40](https://www.aecups.com/en/products/ist7-10-40/) (81), [AEC IST6 200–500](https://www.aecups.com/en/products/ist6-200-500/) (72), [AEC IST7 60–200](https://www.aecups.com/en/products/ist7-60-200/) (68), [AEC IST6 400–1200](https://www.aecups.com/en/products/ist6-400-1200/) (29), [AEC IST6-120](https://www.aecups.com/en/products/ist6-120/) (21), [AEC IST7-T](https://www.aecups.com/en/products/ist7-t/) (15) and [AEC IST9](https://www.aecups.com/en/products/ist9/) (11)
- **400 V three-phase in, 230 V single-phase out (3/1)**: 58 models, 5–40 kVA → [AEC IST7 10–40](https://www.aecups.com/en/products/ist7-10-40/) (48) and [AEC IST9](https://www.aecups.com/en/products/ist9/) (10)

**At least the same rating, online.** The AEC size is the one at or above the other model's kVA, never below it. 54 models are below 1 kVA, AEC's smallest EMEA rating, and go to the 1 kVA model. 168 models are line-interactive or standby: AEC offers none, so they go to the nearest online UPS. 59 models are transformer-based: 15 go to the IST7-T, with its output transformer (100–200 kVA), the other 44 to a transformerless AEC range.

**400 V, 3-wire or 4-wire.** AEC's three-phase ranges run on 380 / 400 / 415 V between lines. The [AEC IST7 10–40](https://www.aecups.com/en/products/ist7-10-40/) and [AEC IST7 60–200](https://www.aecups.com/en/products/ist7-60-200/) connect with 3 phases + N + PE; the IST6 200–500 and 400–1200 with 3Ph+N+PE, and the [AEC IST6 200–500](https://www.aecups.com/en/products/ist6-200-500/) also without neutral (3Ph+PE) as an option. The [AEC IST7-T](https://www.aecups.com/en/products/ist7-t/), with an output transformer, has its rectifier on 3 wires + PE with no neutral and its bypass on 3 phases + N + PE. On a supply with no neutral, tell us: it decides the range.

**Lithium or VRLA.** The match is made on the rating; the battery is chosen after. For 252 models there is also the [AEC IST8](https://www.aecups.com/en/products/ist8/) (1–3 kVA), with its lithium battery inside the UPS. Above that, lithium comes in [AEC L6 Lithium](https://www.aecups.com/en/products/l6-lithium/) cabinets beside the UPS, or with the UPS and the modules in one [AEC All-in-One](https://www.aecups.com/en/products/all-in-one/) cabinet (20 kVA). 34 of the other makers' models are lithium already: for those too the rating decides, and the backup time is worked out again on the AEC battery.

For the replacement

## What to send to get the AEC model that replaces it

1. The model number and a photo of the rating label of the UPS to replace.
2. The supply at the panel: 230 V single-phase or 400 V three-phase; for three-phase, whether a neutral reaches the UPS and whether the output is three-phase (3/3) or single-phase (3/1).
3. The load in kW, measured or read at the panel, not the rating of the old UPS.
4. The backup minutes you need, and lithium or VRLA.
5. Where it goes: a rack (height in U and depth) or the floor, and the way into the room.
6. What it talks to: an SNMP network, dry contacts or USB to a server ([communication cards](https://www.aecups.com/en/products/ups-accessories/)).

An AEC engineer in Lainate replies with the AEC model and the battery for that backup time. For a first idea, try the [UPS finder](https://www.aecups.com/en/tools/ups-finder/).

Questions

## UPS replacement questions

#### How many models does the AEC UPS replacement cover?

693 models of 7 makers, each matched to the AEC model on the same supply with at least the same rating. Another 8 models have no AEC range at their rating or configuration: AEC's engineers answer those.

#### What replaces the APC SMT1000I?

The AEC IST3-1-2X9 at 1 kVA, of the IST3 range, on the same supply (230 V single-phase); it is an online double-conversion UPS, as AEC offers no line-interactive UPS.

#### What replaces the APC GVSUPS20KHS?

The AEC IST7-20 at 20 kVA, of the IST7 10–40 range, on the same supply (400 V three-phase).

#### Is the AEC model a drop-in replacement?

Not always: it takes the same load on the same supply, but it is a starting point, not an equal: backup time, size, outlets or terminals and options differ. Compare both datasheets and the space before you order; send the label and the load and an AEC engineer confirms the match.

#### Does AEC offer line-interactive UPS?

No: every AEC UPS for EMEA is online double conversion. The 168 line-interactive or standby models in the list are matched to the nearest AEC online UPS, which always feeds the load from its inverter.

## Talk to an AEC engineer

Tell us the load, the supply and the backup time you need: we answer with the model and the batteries that fit.

[Contact us](https://www.aecups.com/en/contacts/#form) [+39 02 9415 8991](tel:+390294158991)
