The AEC alternative to Delta, size class by size class: AEC LUMINA for the Amplon RT and Amplon RX; AEC ETHERNO for the Ultron HPH; AEC AUREON for the Ultron HPH; AEC RADIANT for the Modulon DPH; AEC CIRRO-IB for the Ultron NT; AEC INFINITE for the Modulon DPH and Ultron DPM; AEC CIRRO for the Modulon DPH and Ultron DPM.

**17** Delta models compared

**7** size classes

1–3 kVA rack UPS, 120 V

## AEC LUMINA vs Delta.

[Against every maker](https://www.aecups.com/us/comparisons/rack-ups-1-3-kva-120v/)

### 1 kVA

- **Runtime, full load** 11 minLUM1000RT-2U-LI, lithium · best rival 4 min, Delta
- **Runtime, half load** 27 minLUM1000RT-2U-LI, lithium · best rival 10 min, Delta
- **Weight** 20 lb (9 kg)LUM1000RT-2U-LI, lithium · best rival 27 lb (12 kg), Delta
- **Depth** Delta: 12.2 in (310 mm)

### 1.5 kVA

- **Runtime, full load** 11 minLUM1500RT-2U-LI, lithium · best rival 4 min, Delta
- **Runtime, half load** 27 min (AEC runtime table)LUM1500RT-2U-LI, lithium · best rival 10 min, Delta
- **Weight** 32 lb (15 kg)LUM1500RT-2U-LI, lithium · best rival 39 lb (18 kg), Delta
- **Depth** Delta: 16.9 in (429 mm)

### 2 to 2.2 kVA

- **Runtime, full load** 23 minLUM2200RT-2U-LI, lithium · best rival 4 min, Delta
- **Runtime, half load** 46 minLUM2200RT-2U-LI, lithium · best rival 11 min, Delta
- **Weight** 30 lb (14 kg)LUM2000RT-2U-LI, lithium · best rival 42 lb (19 kg), Delta
- **Depth** Delta: 16.1 in (410 mm)

### 3 kVA

- **Runtime, full load** 11 minLUM3000RT-2U-LI, lithium · best rival 4 min, Delta
- **Runtime, half load** 27 minLUM3000RT-2U-LI, lithium · best rival 11 min, Delta
- **Weight** 38 lb (17 kg)LUM3000RT-2U-LI, lithium · best rival 65 lb (29 kg), Delta

### 1 kVA

| Model | Type | Battery | Output | Runtime, full load | Runtime, half load | Efficiency, online | Rack units | Depth | Weight | Warranty, UPS / battery |
| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |
| [**LUM1000RT-2U-LI**](https://www.aecups.com/us/products/lumina/lum1000rt-2u-li/) AEC LUMINA [Datasheet](https://www.aecups.com/us/products/lumina/lum1000rt-2u-li/#datasheet) · [Size it for your load](https://www.aecups.com/us/tools/ups-sizing/) | Online | Lithium, inside | 900 W | 11 min | 27 min | 91.7 % | 2U | 16.5 in (420 mm) | 20 lb (9 kg) | 5 years incl. lithium batteries |
| **Delta** 2 models at this size | Online | Not stated, inside | 900 W | 3 min – 4 min | 9 min – 10 min | 88 % – 91.5 % | 2U | 12.2 in (310 mm) – 13.2 in (335 mm) | 27 lb (12 kg) | not stated / not stated |

### 1.5 kVA

| Model | Type | Battery | Output | Runtime, full load | Runtime, half load | Efficiency, online | Rack units | Depth | Weight | Warranty, UPS / battery |
| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |
| [**LUM1500RT-2U-LI**](https://www.aecups.com/us/products/lumina/lum1500rt-2u-li/) AEC LUMINA [Datasheet](https://www.aecups.com/us/products/lumina/lum1500rt-2u-li/#datasheet) · [Size it for your load](https://www.aecups.com/us/tools/ups-sizing/) | Online | Lithium, inside | 1,350 W | 11 min | 27 min (AEC runtime table) | 92.5 % | 2U | 22.6 in (574 mm) | 32 lb (15 kg) | 5 years incl. lithium batteries |
| **Delta** 1 model at this size | Online | Not stated, inside | 1,350 W | 4 min | 10 min | 92.5 % | 2U | 16.9 in (429 mm) | 39 lb (18 kg) | not stated / not stated |

### 2 to 2.2 kVA

| Model | Type | Battery | Output | Runtime, full load | Runtime, half load | Efficiency, online | Rack units | Depth | Weight | Warranty, UPS / battery |
| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |
| [**LUM2000RT-2U-LI**](https://www.aecups.com/us/products/lumina/lum2000rt-2u-li/) AEC LUMINA [Datasheet](https://www.aecups.com/us/products/lumina/lum2000rt-2u-li/#datasheet) · [Size it for your load](https://www.aecups.com/us/tools/ups-sizing/) | Online | Lithium, inside | 1,800 W | 11 min | 27 min | 92.5 % | 2U | 22.4 in (570 mm) | 30 lb (14 kg) | 5 years incl. lithium batteries |
| [**LUM2200RT-2U-LI**](https://www.aecups.com/us/products/lumina/lum2200rt-2u-li/) AEC LUMINA [Datasheet](https://www.aecups.com/us/products/lumina/lum2200rt-2u-li/#datasheet) · [Size it for your load](https://www.aecups.com/us/tools/ups-sizing/) | Online | Lithium, inside | 1,980 W | 23 min | 46 min | 92.6 % | 2U | 24.2 in (615 mm) | 42 lb (19 kg) | 5 years incl. lithium batteries |
| **Delta** 2 models at this size | Online | Not stated, inside | 1,800 W | 3 min – 4 min | 10 min – 11 min | 89 % – 93 % | 2U | 16.1 in (410 mm) – 16.9 in (429 mm) | 42 lb (19 kg) – 46 lb (21 kg) | not stated / not stated |

### 3 kVA

| Model | Type | Battery | Output | Runtime, full load | Runtime, half load | Efficiency, online | Rack units | Depth | Weight | Warranty, UPS / battery |
| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |
| [**LUM3000RT-2U-LI**](https://www.aecups.com/us/products/lumina/lum3000rt-2u-li/) AEC LUMINA [Datasheet](https://www.aecups.com/us/products/lumina/lum3000rt-2u-li/#datasheet) · [Size it for your load](https://www.aecups.com/us/tools/ups-sizing/) | Online | Lithium, inside | 2,700 W | 11 min | 27 min | 92.5 % | 2U | 22.4 in (570 mm) | 38 lb (17 kg) | 5 years incl. lithium batteries |
| **Delta** 2 models at this size | Online | Not stated, inside | 2,700 W | 3 min – 4 min | 11 min | 90 % – 93 % | 2U | 22.2 in (564 mm) – 24.8 in (630 mm) | 65 lb (29 kg) – 66 lb (30 kg) | not stated / not stated |

10–30 kVA three-phase UPS, 208 V

## AEC ETHERNO vs Delta.

[Against every maker](https://www.aecups.com/us/comparisons/three-phase-ups-10-30-kva-208v/)

### 20 kVA

- **Footprint W × D** 12.6 × 39.1 in (320 × 993 mm)ETH20-2X50A-LI, lithium · best rival 20.5 × 31.5 in (520 × 800 mm), Delta, VRLA
- **Weight** 390 lb (177 kg)ETH20-2X50A-LI, lithium · best rival 750 lb (340 kg), Delta, VRLA

### 30 kVA

- **Footprint W × D** 12.6 × 39.1 in (320 × 993 mm)ETH30-3X50A-LI, lithium · best rival 20.5 × 31.5 in (520 × 800 mm), Delta, VRLA
- **Weight** 485 lb (220 kg)ETH30-3X50A-LI, lithium · best rival 926 lb (420 kg), Delta, VRLA

### 20 kVA

| Model | Output | Battery | Runtime, full load | Runtime, half load | Efficiency, online | Footprint W × D | Weight | Warranty, UPS / battery |
| --- | --- | --- | --- | --- | --- | --- | --- | --- |
| [**ETH20-2X50A-LI**](https://www.aecups.com/us/products/etherno/eth20-2x50a-li/) AEC ETHERNO [Datasheet](https://www.aecups.com/us/products/etherno/eth20-2x50a-li/#datasheet) · [Size it for your load](https://www.aecups.com/us/tools/ups-sizing/) | 20 kW | Lithium, 2 × 50 Ah modules, inside | 14 min | 27 min | 94 % | 12.6 × 39.1 in (320 × 993 mm) | 390 lb (177 kg) | 5 years |
| [**ETH20-3X50A-LI**](https://www.aecups.com/us/products/etherno/eth20-3x50a-li/) AEC ETHERNO [Datasheet](https://www.aecups.com/us/products/etherno/eth20-3x50a-li/#datasheet) · [Size it for your load](https://www.aecups.com/us/tools/ups-sizing/) | 20 kW | Lithium, 3 × 50 Ah modules, inside | 20 min | 41 min | 94 % | 12.6 × 39.1 in (320 × 993 mm) | 472 lb (214 kg) | 5 years |
| **Delta** 1 model at this size | 20 kW | VRLA, inside | — | — | 94 % | 20.5 × 31.5 in (520 × 800 mm) | 750 lb (340 kg) | not stated / not stated |

### 30 kVA

| Model | Output | Battery | Runtime, full load | Runtime, half load | Efficiency, online | Footprint W × D | Weight | Warranty, UPS / battery |
| --- | --- | --- | --- | --- | --- | --- | --- | --- |
| [**ETH30-3X50A-LI**](https://www.aecups.com/us/products/etherno/eth30-3x50a-li/) AEC ETHERNO [Datasheet](https://www.aecups.com/us/products/etherno/eth30-3x50a-li/#datasheet) · [Size it for your load](https://www.aecups.com/us/tools/ups-sizing/) | 30 kW | Lithium, 3 × 50 Ah modules, inside | 14 min | 27 min | 94 % | 12.6 × 39.1 in (320 × 993 mm) | 485 lb (220 kg) | 5 years |
| **Delta** 1 model at this size | 30 kW | VRLA, inside | — | — | 94 % | 20.5 × 31.5 in (520 × 800 mm) | 926 lb (420 kg) | not stated / not stated |

10–30 kVA lead-acid three-phase UPS, 208 V

## AEC AUREON vs Delta.

[Against every maker](https://www.aecups.com/us/comparisons/lead-acid-three-phase-ups-10-30-kva-208v/)

### 20 kVA

- **Footprint W × D** 14.9 × 39.1 in (378 × 993 mm)AUR20-60X9A, VRLA · best rival 20.5 × 31.5 in (520 × 800 mm), Delta, VRLA
- **Weight** 609 lb (276 kg)AUR20-60X9A, VRLA · best rival 750 lb (340 kg), Delta, VRLA

### 30 kVA

- **Footprint W × D** 14.9 × 39.1 in (378 × 993 mm)AUR30-80X9A, VRLA · best rival 20.5 × 31.5 in (520 × 800 mm), Delta, VRLA
- **Weight** 750 lb (340 kg)AUR30-80X9A, VRLA · best rival 926 lb (420 kg), Delta, VRLA

### 20 kVA

| Model | Output | Battery | Runtime, full load | Runtime, half load | Efficiency, online | Footprint W × D | Weight | Warranty, UPS / battery |
| --- | --- | --- | --- | --- | --- | --- | --- | --- |
| [**AUR20-60X9A**](https://www.aecups.com/us/products/aureon/aur20-60x9a/) AEC AUREON [Datasheet](https://www.aecups.com/us/products/aureon/aur20-60x9a/#datasheet) · [Size it for your load](https://www.aecups.com/us/tools/ups-sizing/) | 20 kW | VRLA, 60 × 12 V 9 Ah blocks, inside | 4.5 min (AEC runtime table) | 13.5 min (AEC runtime table) | 94 % | 14.9 × 39.1 in (378 × 993 mm) | 609 lb (276 kg) | 3 years on UPS · 2 years on VRLA batteries |
| [**AUR20-80X9A**](https://www.aecups.com/us/products/aureon/aur20-80x9a/) AEC AUREON [Datasheet](https://www.aecups.com/us/products/aureon/aur20-80x9a/#datasheet) · [Size it for your load](https://www.aecups.com/us/tools/ups-sizing/) | 20 kW | VRLA, 80 × 12 V 9 Ah blocks, inside | 7.5 min (AEC runtime table) | 20 min (AEC runtime table) | 94 % | 14.9 × 39.1 in (378 × 993 mm) | 726 lb (329 kg) | 3 years on UPS · 2 years on VRLA batteries |
| **Delta** 1 model at this size | 20 kW | VRLA, inside | — | — | 94 % | 20.5 × 31.5 in (520 × 800 mm) | 750 lb (340 kg) | not stated / not stated |

### 30 kVA

| Model | Output | Battery | Runtime, full load | Runtime, half load | Efficiency, online | Footprint W × D | Weight | Warranty, UPS / battery |
| --- | --- | --- | --- | --- | --- | --- | --- | --- |
| [**AUR30-80X9A**](https://www.aecups.com/us/products/aureon/aur30-80x9a/) AEC AUREON [Datasheet](https://www.aecups.com/us/products/aureon/aur30-80x9a/#datasheet) · [Size it for your load](https://www.aecups.com/us/tools/ups-sizing/) | 30 kW | VRLA, 80 × 12 V 9 Ah blocks, inside | 4 min | 14 min | 94 % | 14.9 × 39.1 in (378 × 993 mm) | 750 lb (340 kg) | 3 years on UPS · 2 years on VRLA batteries |
| **Delta** 1 model at this size | 30 kW | VRLA, inside | — | — | 94 % | 20.5 × 31.5 in (520 × 800 mm) | 926 lb (420 kg) | not stated / not stated |

Modular three-phase UPS, 208 V

## AEC RADIANT vs Delta.

[Against every maker](https://www.aecups.com/us/comparisons/modular-ups-208v/)

### 40 to 60 kVA

- **Efficiency, online** Delta: 95 %

### 40 to 60 kVA

| Model | Output | Architecture | Battery | Efficiency, online | Footprint W × D | Warranty, UPS / battery |
| --- | --- | --- | --- | --- | --- | --- |
| [**RAD90-3X15**](https://www.aecups.com/us/products/radiant/rad90-3x15/) AEC RADIANT [Datasheet](https://www.aecups.com/us/products/radiant/rad90-3x15/#datasheet) · [Size it for your load](https://www.aecups.com/us/tools/ups-sizing/) | 45 kW | Modular, 15 kVA modules | VRLA, external bank | 94 % | 17.4 × 33.1 in (442 × 840 mm) | 3 years on UPS · 2 years on VRLA batteries |
| [**RAD90-4X15**](https://www.aecups.com/us/products/radiant/rad90-4x15/) AEC RADIANT [Datasheet](https://www.aecups.com/us/products/radiant/rad90-4x15/#datasheet) · [Size it for your load](https://www.aecups.com/us/tools/ups-sizing/) | 60 kW | Modular, 15 kVA modules | VRLA, external bank | 94 % | 17.4 × 33.1 in (442 × 840 mm) | 3 years on UPS · 2 years on VRLA batteries |
| [**RADIB100-2X20**](https://www.aecups.com/us/products/radiant-ib/radib100-2x20/) AEC RADIANT-IB [Datasheet](https://www.aecups.com/us/products/radiant-ib/radib100-2x20/#datasheet) · [Size it for your load](https://www.aecups.com/us/tools/ups-sizing/) | 40 kW | Modular, 20 kVA modules | VRLA, inside | 94 % | 23.6 × 39.3 in (599 × 998 mm) | 3 years on UPS · 2 years on VRLA batteries |
| [**RADIB100-3X20**](https://www.aecups.com/us/products/radiant-ib/radib100-3x20/) AEC RADIANT-IB [Datasheet](https://www.aecups.com/us/products/radiant-ib/radib100-3x20/#datasheet) · [Size it for your load](https://www.aecups.com/us/tools/ups-sizing/) | 60 kW | Modular, 20 kVA modules | VRLA, inside | 94 % | 23.6 × 39.3 in (599 × 998 mm) | 3 years on UPS · 2 years on VRLA batteries |
| **Delta** 1 model at this size | 60 kW | Modular, 15 kVA modules | Not stated, inside | 95 % | 23.6 × 33.5 in (600 × 850 mm) | not stated / not stated |

30–150 kVA 480 V UPS with internal batteries

## AEC CIRRO-IB vs Delta.

[Against every maker](https://www.aecups.com/us/comparisons/ups-480v-30-150-kva-internal-batteries/)

### 90 to 150 kVA

### 90 to 150 kVA

| Model | Output | Architecture | Battery | Efficiency, online | Footprint W × D | Warranty, UPS / battery |
| --- | --- | --- | --- | --- | --- | --- |
| [**CIRIB150-3X30**](https://www.aecups.com/us/products/cirro-ib/cirib150-3x30/) AEC CIRRO-IB [Datasheet](https://www.aecups.com/us/products/cirro-ib/cirib150-3x30/#datasheet) · [Size it for your load](https://www.aecups.com/us/tools/ups-sizing/) | 90 kW | Modular, 30 kVA modules | VRLA, inside | 96 % | 23.6 × 39.3 in (599 × 998 mm) | 3 years on UPS · 2 years on VRLA batteries |
| [**CIRIB150-4X30**](https://www.aecups.com/us/products/cirro-ib/cirib150-4x30/) AEC CIRRO-IB [Datasheet](https://www.aecups.com/us/products/cirro-ib/cirib150-4x30/#datasheet) · [Size it for your load](https://www.aecups.com/us/tools/ups-sizing/) | 120 kW | Modular, 30 kVA modules | VRLA, inside | 96 % | 23.6 × 39.3 in (599 × 998 mm) | 3 years on UPS · 2 years on VRLA batteries |
| [**CIRIB150-5X30**](https://www.aecups.com/us/products/cirro-ib/cirib150-5x30/) AEC CIRRO-IB [Datasheet](https://www.aecups.com/us/products/cirro-ib/cirib150-5x30/#datasheet) · [Size it for your load](https://www.aecups.com/us/tools/ups-sizing/) | 150 kW | Modular, 30 kVA modules | VRLA, inside | 96 % | 23.6 × 39.3 in (599 × 998 mm) | 3 years on UPS · 2 years on VRLA batteries |
| **Delta** 1 model at this size | 90 kW | — | Not stated | — | 47.2 × 32.7 in (1,200 × 830 mm) | not stated / not stated |

Large 480 V UPS

## AEC INFINITE vs Delta.

[Against every maker](https://www.aecups.com/us/comparisons/large-ups-480v/)

### 200 to 600 kW

- **UPS weight per kW** 2.96 lb (1.34 kg)INF-200 · best rival 5.73 lb (2.60 kg), Delta

### 750 to 1,500 kW

### 200 to 600 kW

| Model | Output | Architecture | Efficiency, online | Weight | UPS weight per kW | Warranty, UPS / battery |
| --- | --- | --- | --- | --- | --- | --- |
| [**INF-200**](https://www.aecups.com/us/products/infinite/inf-200/) AEC INFINITE [Datasheet](https://www.aecups.com/us/products/infinite/inf-200/#datasheet) · [Size it for your load](https://www.aecups.com/us/tools/ups-sizing/) | 200 kW | Modular, 100 kVA modules | 97.3 % | 591 lb (268 kg) | 2.96 lb (1.34 kg) | 3 years on UPS, 5 if registered · 5 years on lithium cabinets incl. batteries |
| [**INF-200+1**](https://www.aecups.com/us/products/infinite/inf-200-1/) AEC INFINITE [Datasheet](https://www.aecups.com/us/products/infinite/inf-200-1/#datasheet) · [Size it for your load](https://www.aecups.com/us/tools/ups-sizing/) | 200 kW | Modular, 100 kVA modules | 97.3 % | 710 lb (322 kg) | 3.55 lb (1.61 kg) | 3 years on UPS, 5 if registered · 5 years on lithium cabinets incl. batteries |
| [**INF-400**](https://www.aecups.com/us/products/infinite/inf-400/) AEC INFINITE · 2 frames in parallel [Datasheet](https://www.aecups.com/us/products/infinite/inf-400/#datasheet) · [Size it for your load](https://www.aecups.com/us/tools/ups-sizing/) | 400 kW | Modular, 100 kVA modules | 97.3 % | 1,183 lb (536 kg) | 2.96 lb (1.34 kg) | 3 years on UPS, 5 if registered · 5 years on lithium cabinets incl. batteries |
| [**INF-600**](https://www.aecups.com/us/products/infinite/inf-600/) AEC INFINITE · 3 frames in parallel [Datasheet](https://www.aecups.com/us/products/infinite/inf-600/#datasheet) · [Size it for your load](https://www.aecups.com/us/tools/ups-sizing/) | 600 kW | Modular, 100 kVA modules | 97.3 % | 1,774 lb (805 kg) | 2.96 lb (1.34 kg) | 3 years on UPS, 5 if registered · 5 years on lithium cabinets incl. batteries |
| **Delta** 4 models at this size | 300 kW / 500 kW / 250 kW | Modular, 50 kVA modules | 96 % – 97 % | 589 lb (267 kg) (DPH-300K-HV); 1,162 lb (527 kg) (DPH-500K-HV); 2,136 lb (969 kg) (DPM-250K); 2,866 lb (1,300 kg) (DPM-500K) | 5.73 lb (2.60 kg) (DPM-500K); 8.54 lb (3.88 kg) (DPM-250K) | not stated / not stated |

### 750 to 1,500 kW

| Model | Output | Architecture | Efficiency, online | Weight | UPS weight per kW | Warranty, UPS / battery |
| --- | --- | --- | --- | --- | --- | --- |
| [**INF15-750**](https://www.aecups.com/us/products/infinite-1-5mw/inf15-750/) AEC INFINITE 1.5MW [Datasheet](https://www.aecups.com/us/products/infinite-1-5mw/inf15-750/#datasheet) · [Size it for your load](https://www.aecups.com/us/tools/ups-sizing/) | 750 kW | Modular, 125 kVA modules | 97.5 % | 5,456 lb (2,475 kg) | 7.28 lb (3.30 kg) | 3 years on UPS, 5 if registered · 5 years on lithium cabinets incl. batteries |
| [**INF15-1000**](https://www.aecups.com/us/products/infinite-1-5mw/inf15-1000/) AEC INFINITE 1.5MW [Datasheet](https://www.aecups.com/us/products/infinite-1-5mw/inf15-1000/#datasheet) · [Size it for your load](https://www.aecups.com/us/tools/ups-sizing/) | 1,000 kW | Modular, 125 kVA modules | 97.5 % | 5,695 lb (2,583 kg) | 5.69 lb (2.58 kg) | 3 years on UPS, 5 if registered · 5 years on lithium cabinets incl. batteries |
| [**INF15-1250**](https://www.aecups.com/us/products/infinite-1-5mw/inf15-1250/) AEC INFINITE 1.5MW [Datasheet](https://www.aecups.com/us/products/infinite-1-5mw/inf15-1250/#datasheet) · [Size it for your load](https://www.aecups.com/us/tools/ups-sizing/) | 1,250 kW | Modular, 125 kVA modules | 97.5 % | 5,933 lb (2,691 kg) | 4.75 lb (2.15 kg) | 3 years on UPS, 5 if registered · 5 years on lithium cabinets incl. batteries |
| [**INF15-1500**](https://www.aecups.com/us/products/infinite-1-5mw/inf15-1500/) AEC INFINITE 1.5MW [Datasheet](https://www.aecups.com/us/products/infinite-1-5mw/inf15-1500/#datasheet) · [Size it for your load](https://www.aecups.com/us/tools/ups-sizing/) | 1,500 kW | Modular, 125 kVA modules | 97.5 % | 6,171 lb (2,799 kg) | 4.11 lb (1.87 kg) | 3 years on UPS, 5 if registered · 5 years on lithium cabinets incl. batteries |
| **Delta** 2 models at this size | 750 kW / 900 kW | — | 96 % – 97.5 % | 4,409 lb (2,000 kg) (Ultron DPM); 4,467 lb (2,026 kg) (Ultron DPM Gen2) | 4.96 lb (2.25 kg) – 5.88 lb (2.67 kg) | not stated / not stated |

Modular 480 V UPS up to 1,600 kVA

## AEC CIRRO vs Delta.

[Against every maker](https://www.aecups.com/us/comparisons/modular-ups-480v-up-to-1600-kva/)

### 100 to 400 kVA

- **Efficiency, online** Delta: 97 %

### 500 to 800 kVA

- **UPS weight per kW** 2.38 lb (1.08 kg)CIR800-8X100 · best rival 5.73 lb (2.60 kg), Delta

### 1,000 to 1,600 kVA

- **UPS weight per kW** 2.18 lb (0.99 kg)CIR1200-12X100 · best rival 4.96 lb (2.25 kg), Delta

### 100 to 400 kVA

| Model | Output | Architecture | Efficiency, online | Weight | UPS weight per kW | Warranty, UPS / battery |
| --- | --- | --- | --- | --- | --- | --- |
| [**CIR360-2X60**](https://www.aecups.com/us/products/cirro/cir360-2x60/) AEC CIRRO [Datasheet](https://www.aecups.com/us/products/cirro/cir360-2x60/#datasheet) · [Size it for your load](https://www.aecups.com/us/tools/ups-sizing/) | 120 kW | Modular, 60 kVA modules | 96 % | 727 lb (330 kg) | 6.06 lb (2.75 kg) | 3 years on UPS · 2 years on VRLA batteries |
| [**CIR360-4X60**](https://www.aecups.com/us/products/cirro/cir360-4x60/) AEC CIRRO [Datasheet](https://www.aecups.com/us/products/cirro/cir360-4x60/#datasheet) · [Size it for your load](https://www.aecups.com/us/tools/ups-sizing/) | 240 kW | Modular, 60 kVA modules | 96 % | 908 lb (412 kg) | 3.78 lb (1.72 kg) | 3 years on UPS · 2 years on VRLA batteries |
| [**CIR360-6X60**](https://www.aecups.com/us/products/cirro/cir360-6x60/) AEC CIRRO [Datasheet](https://www.aecups.com/us/products/cirro/cir360-6x60/#datasheet) · [Size it for your load](https://www.aecups.com/us/tools/ups-sizing/) | 360 kW | Modular, 60 kVA modules | 96 % | 1,088 lb (494 kg) | 3.02 lb (1.37 kg) | 3 years on UPS · 2 years on VRLA batteries |
| **Delta** 3 models at this size | 300 kW / 250 kW / 90 kW | Modular, 50 kVA modules | 96 % (Ultron DPM); 97 % (Modulon DPH) | 589 lb (267 kg) (Modulon DPH); 2,136 lb (969 kg) (Ultron DPM); 2,480 lb (1,125 kg) (Ultron NT) | 8.54 lb (3.88 kg) (Ultron DPM) | not stated / not stated |

### 500 to 800 kVA

| Model | Output | Architecture | Efficiency, online | Weight | UPS weight per kW | Warranty, UPS / battery |
| --- | --- | --- | --- | --- | --- | --- |
| [**CIR600-6X100**](https://www.aecups.com/us/products/cirro/cir600-6x100/) AEC CIRRO [Datasheet](https://www.aecups.com/us/products/cirro/cir600-6x100/#datasheet) · [Size it for your load](https://www.aecups.com/us/tools/ups-sizing/) | 600 kW | Modular, 100 kVA modules | 97 % | 1,515 lb (687 kg) | 2.52 lb (1.14 kg) | 3 years on UPS · 2 years on VRLA batteries |
| [**CIR800-8X100**](https://www.aecups.com/us/products/cirro/cir800-8x100/) AEC CIRRO [Datasheet](https://www.aecups.com/us/products/cirro/cir800-8x100/#datasheet) · [Size it for your load](https://www.aecups.com/us/tools/ups-sizing/) | 800 kW | Modular, 100 kVA modules | 97 % | 1,902 lb (863 kg) | 2.38 lb (1.08 kg) | 3 years on UPS · 2 years on VRLA batteries |
| **Delta** 3 models at this size | 500 kW / 750 kW | Modular, 50 kVA modules | 96 % – 97 % | 1,162 lb (527 kg) (Modulon DPH); 2,866 lb (1,300 kg) (DPM-500K); 4,409 lb (2,000 kg) (DPM-750K) | 5.73 lb (2.60 kg) (DPM-500K); 5.88 lb (2.67 kg) (DPM-750K) | not stated / not stated |

### 1,000 to 1,600 kVA

| Model | Output | Architecture | Efficiency, online | Weight | UPS weight per kW | Warranty, UPS / battery |
| --- | --- | --- | --- | --- | --- | --- |
| [**CIR1200-12X100**](https://www.aecups.com/us/products/cirro/cir1200-12x100/) AEC CIRRO [Datasheet](https://www.aecups.com/us/products/cirro/cir1200-12x100/#datasheet) · [Size it for your load](https://www.aecups.com/us/tools/ups-sizing/) | 1,200 kW | Modular, 100 kVA modules | 97 % | 2,619 lb (1,188 kg) | 2.18 lb (0.99 kg) | 3 years on UPS · 2 years on VRLA batteries |
| [**CIR1600-16X100**](https://www.aecups.com/us/products/cirro/cir1600-16x100/) AEC CIRRO [Datasheet](https://www.aecups.com/us/products/cirro/cir1600-16x100/#datasheet) · [Size it for your load](https://www.aecups.com/us/tools/ups-sizing/) | 1,600 kW | Modular, 100 kVA modules | 97 % | 3,796 lb (1,722 kg) | 2.37 lb (1.08 kg) | 3 years on UPS · 2 years on VRLA batteries |
| **Delta** 1 model at this size | 900 kW | — | 97.5 % | 4,467 lb (2,026 kg) | 4.96 lb (2.25 kg) | not stated / not stated |

Questions

## AEC or Delta?

#### Is AEC a good alternative to Delta?

Yes, in the 7 size classes on this page, where 17 Delta models are compared with AEC's, each in the configuration its datasheet lists (the Battery column says which). Where AEC's figure leads: runtime, full load at 1 kVA, the AEC LUM1000RT-2U-LI (lithium) with 11 min against 4 min for the Delta RT-1K; runtime, half load at 1 kVA, the AEC LUM1000RT-2U-LI (lithium) with 27 min against 10 min for the Delta RT-1K; footprint W × D at 20 kVA, the AEC ETH20-2X50A-LI (lithium) with 12.6 × 39.1 in (320 × 993 mm) against 20.5 × 31.5 in (520 × 800 mm) for the Delta HPH-20K-LV-B (VRLA). Where Delta's leads: depth at 1 kVA against AEC LUMINA, the Delta RX-1K with 12.2 in (310 mm); efficiency, online at 40 to 60 kVA against AEC RADIANT, the Delta DPH-60K-LV with 95 %. The cards above each table give every column, size by size.

#### Which AEC UPS replaces a Delta 120 V?

The AEC LUMINA: 1 kVA: LUM1000RT-2U-LI against 2 Delta models; 1.5 kVA: LUM1500RT-2U-LI against 1 Delta model; 2 to 2.2 kVA: LUM2000RT-2U-LI, LUM2200RT-2U-LI against 2 Delta models; 3 kVA: LUM3000RT-2U-LI against 2 Delta models.

#### Which AEC UPS replaces a Delta 208 V?

The AEC ETHERNO: 20 kVA: ETH20-2X50A-LI, ETH20-3X50A-LI against 1 Delta model; 30 kVA: ETH30-3X50A-LI against 1 Delta model. The AEC AUREON: 20 kVA: AUR20-60X9A, AUR20-80X9A against 1 Delta model; 30 kVA: AUR30-80X9A against 1 Delta model.

#### Where do the Delta figures come from?

From Delta's own published documents, read 10 Oct 2026; each one is named, model by model, under Sources. Where two Delta documents disagree, the more conservative figure is used.

Sources

## Where the Delta figures come from

#### Delta: 17 models , documents read 10 Oct 2026

- RT-1K: delta-americas.com/…/rt-series-1kva-3kva-single-phase-ups-120v; Leaflet\_UPS\_RT-1-3kVA-120V\_en-na\_v2-JY-r2411.pdf (deltapowersolutions.com); delta-americas.com/…/Amplon/ALL.
- RX-1K: delta-americas.com/…/rx-series-1kva-3kva-single-phase-ups; delta-americas.com/…/Amplon/ALL.
- RT-1.5K: delta-americas.com/…/rt-series-1kva-3kva-single-phase-ups-120v; Leaflet\_UPS\_RT-1-3kVA-120V\_en-na\_v2-JY-r2411.pdf (deltapowersolutions.com); delta-americas.com/…/Amplon/ALL.
- RT-2K: delta-americas.com/…/rt-series-1kva-3kva-single-phase-ups-120v; Leaflet\_UPS\_RT-1-3kVA-120V\_en-na\_v2-JY-r2411.pdf (deltapowersolutions.com); delta-americas.com/…/Amplon/ALL.
- RX-2K: delta-americas.com/…/rx-series-1kva-3kva-single-phase-ups; delta-americas.com/…/Amplon/ALL.
- RT-3K: delta-americas.com/…/rt-series-1kva-3kva-single-phase-ups-120v; Leaflet\_UPS\_RT-1-3kVA-120V\_en-na\_v2-JY-r2411.pdf (deltapowersolutions.com); delta-americas.com/…/Amplon/ALL.
- RX-3K: delta-americas.com/…/rx-series-1kva-3kva-single-phase-ups; delta-americas.com/…/Amplon/ALL.
- HPH-20K-LV-B: delta-americas.com/…/hph-series-20-60kva-208v-120v-ups.
- HPH-30K-LV-B: delta-americas.com/…/hph-series-20-60kva-208v-120v-ups.
- DPH-60K-LV: delta-americas.com/…/dph-series-15-kva-105kva-three-phase-modular-ups.
- NT-100K: delta-americas.com/…/nt-series-15kva-100kva-480v-three-phase-ups.
- DPH-300K-HV: delta-americas.com/…/dph-series-50kva-500kva-480v-modular-ups.
- DPH-500K-HV: delta-americas.com/…/dph-series-50kva-500kva-480v-modular-ups.
- DPM-250K: delta-americas.com/…/dpm-series-250kva-1250kva-ups.
- DPM-500K: delta-americas.com/…/dpm-series-250kva-1250kva-ups.
- DPM-750K: delta-americas.com/…/dpm-series-250kva-1250kva-ups.
- DPM G2-900K: delta-americas.com/…/600kva-2500kva-three-phase-ups-dpm-gen2-series.

Rival figures from each maker's own published documents, read 10 Oct 2026 and named model by model under Sources; where two of a maker's documents disagree, the more conservative figure is used. AEC figures from the AEC 2026 catalog. Efficiency is the online (double-conversion) figure, not ECO mode. Weights and footprints compared only for units with their batteries inside; a weight marked UPS only leaves the battery cabinets out. Weights per kW are of the UPS alone, without batteries. Brand and model names are trademarks of their owners; AEC is not affiliated with them and names their models only to compare them.

AEC against the other makers: [AEC vs APC](https://www.aecups.com/us/comparisons/aec-vs-apc/) [AEC vs Vertiv](https://www.aecups.com/us/comparisons/aec-vs-vertiv/) [AEC vs Eaton](https://www.aecups.com/us/comparisons/aec-vs-eaton/) [AEC vs Tripp Lite](https://www.aecups.com/us/comparisons/aec-vs-tripp-lite/) [AEC vs CyberPower](https://www.aecups.com/us/comparisons/aec-vs-cyberpower/) [AEC vs Xtreme Power](https://www.aecups.com/us/comparisons/aec-vs-xtreme-power/) [AEC vs Toshiba](https://www.aecups.com/us/comparisons/aec-vs-toshiba/) [All comparisons](https://www.aecups.com/us/comparisons/)

## Replacing a Delta UPS?

Send the Delta model or its label and the load: we reply with the AEC model, the runtime and the lead time.

[Send your project](https://www.aecups.com/us/contacts/#form) [+1 786 553 2100](tel:+17865532100)