Relay alarms · DRYCNT

# Dry contact relay card for AEC UPS

Potential-free relays that signal the UPS's states to a building management system, an alarm panel or a PLC: mains failure, battery low, UPS fault and bypass. It goes in the intelligent slot and fits every AEC series.

By series

## Dry contacts and slots on each AEC series.

From the AEC accessories catalog (2026): the contacts each series has as standard, and the slots the card or a network card can take.

| Series | Dry contacts | Slots |
| --- | --- | --- |
| [LUMINA](https://www.aecups.com/us/products/lumina/) | RS-485 and dry contacts on the card | 1 intelligent |
| [FERRUS](https://www.aecups.com/us/products/ferrus/) | on the dry contact card | 1 intelligent |
| [FERRUS RT](https://www.aecups.com/us/products/ferrus-rt/) | on the dry contact card | 1 intelligent |
| [FERRUS SP](https://www.aecups.com/us/products/ferrus-sp/) | on the dry contact card | 2 on the tower, 1 on the rack |
| [FERRUS SP RT](https://www.aecups.com/us/products/ferrus-sp-rt/) | on the dry contact card | 1 |
| [ETHERNO](https://www.aecups.com/us/products/etherno/) | 5 outputs, 1 input, EPO | 2 intelligent |
| [AUREON](https://www.aecups.com/us/products/aureon/) | 5 outputs, 1 input, EPO | 2 intelligent |
| [RADIANT](https://www.aecups.com/us/products/radiant/) | 3 relays and a battery trip; inputs, EPO | SNMP and intelligent |
| [RADIANT-IB](https://www.aecups.com/us/products/radiant-ib/) | 3 relays and a battery trip; inputs, EPO | SNMP and intelligent |
| [CIRRO-IB](https://www.aecups.com/us/products/cirro-ib/) | 3 relays and a battery trip; inputs, EPO | SNMP and intelligent |
| [CIRRO](https://www.aecups.com/us/products/cirro/) | standard; the card for more outputs | not published |
| [INFINITE](https://www.aecups.com/us/products/infinite/) | 3 outputs, 4 inputs, EPO1 and EPO2 | SNMP and expansion |

For INFINITE the catalog also gives 18 output and 13 input functions, on relays rated 30 V DC, 2 A.

From the catalog

## What it does.

- Dry contact relay card for AEC UPS systems.
- Function: potential-free relay outputs for remote alarm signalling (mains failure, battery low, UPS fault, bypass).
- Installation: plug-in intelligent slot.
- Compatibility: all AEC UPS series.
- Size 5.1" W × 4.3" D × 0.8" H (130 × 109 × 20 mm), 0.4 lb (0.2 kg).

Already built in

## Series with dry contacts as standard.

[ETHERNO](https://www.aecups.com/us/products/etherno/), [CIRRO](https://www.aecups.com/us/products/cirro/), [INFINITE](https://www.aecups.com/us/products/infinite/) and [INFINITE 1.5MW](https://www.aecups.com/us/products/infinite-1-5mw/) have dry contacts among their standard ports; the card adds them to the others. For every measurement over the network, use the [SNMP card](https://www.aecups.com/us/products/accessories/snmp-card/).

Questions

## Questions people ask

#### What is a dry contact card on a UPS?

A card of potential-free relays: each relay opens or closes when the UPS enters a state, such as a mains failure, a low battery, a fault or bypass. A building management system, an alarm panel or a PLC reads the contacts without any network or protocol.

#### Which AEC UPS takes the dry contact card?

Every AEC series: it goes into the UPS's intelligent slot, according to the AEC accessories catalog (2026), which gives the slots of each series in the table above.

#### What signals does the dry contact card give?

Mains failure, battery low, UPS fault and bypass, as potential-free relays, by the AEC accessories catalog (2026). The relay rating and the pin-out of the card are not published on this site: ask AEC for them with your project.

#### Dry contacts or SNMP?

Dry contacts give a few on/off signals to wired systems; the SNMP card gives every measurement and alarm over the network. Many sites use both: dry contacts to the building system, SNMP to IT.

## Wire the alarms to your building system

Tell us the UPS and the system that reads the alarms. We answer with the contacts, the slot and the card.