AUREON · 208V three-phase UPS

# AUR30-80X9A AUREON 30 kVA, 208V three-phase UPS

VRLA 30 kVA Online double conversion

The AEC AUREON AUR30-80X9A is a 30 kVA / 30 kW online double-conversion UPS for 208 V three-phase loads, with internal VRLA batteries. Kept at 80 % of its rating, it carries loads up to 24 kW.

**30 kVA / 30 kW** Rating

**14.9 × 39.1 × 49.2 in** W × D × H

**750 lb** Weight

**VRLA, internal** Battery

Technical data [Catalog (PDF)](https://www.aecups.com/docs/AEC_AUREON_2026.pdf) [Contact us](https://www.aecups.com/us/contacts/?interest=UPS%20three-phase&msg=About%20the%20AUR30-80X9A%20(AUREON)%3A%20%0AQuantity%3A%20#form)

Series picture.

Load by load

## The AUR30-80X9A at 25, 50, 75 and 100 % load.

Its 30 kW rating in four steps, worked out from its own catalog figures.

**At 25, 50, 75 and 100 % load**

| Load | Output current per phase, at 208 V | Efficiency | Heat to remove | Heat to remove (BTU/h) |
| --- | --- | --- | --- | --- |
| 25 % of the AUR30-80X9A, 7.5 kW | 20.8 A per phase | 92.5 % efficient | 608 W of heat | 2,070 BTU/h to cool |
| 50 % of the AUR30-80X9A, 15 kW | 41.6 A per phase | 93.9 % efficient | 974 W of heat | 3,320 BTU/h to cool |
| 75 % of the AUR30-80X9A, 23 kW | 62.5 A per phase | 94.0 % efficient | 1.4 kW of heat | 4,900 BTU/h to cool |
| 100 % of the AUR30-80X9A, 30 kW | 83.3 A per phase | 93.8 % efficient | 2.0 kW of heat | 6,770 BTU/h to cool |

Current = kVA × load ÷ (√3 × volts).

Heat = load × (100 ÷ efficiency − 1); 1 kW is 3,412 BTU/h.

From the 2026 catalog

## What is the AUR30-80X9A?

The code AUR30-80X9A orders these catalog items:

- 1 × [AUR-30](https://www.aecups.com/us/products/aureon/aur-30/): 30 kVA tower, without batteries, 14.9 × 39.1 × 49.2 in (378 × 993 × 1,250 mm), 282 lb (127.9 kg)
- 80 × CSB-9AH: 12 V 9 Ah VRLA battery block, 5.9 lb (2.7 kg) each
- Output: 30,000 VA / 30,000 W (unity power factor, kVA = kW).
- Input / Output: 208 V three-phase.
- Technology: 3-level IGBT; cold start, self-cleaning and smart functions.
- Battery: internal hot-swappable VRLA, 80 × 12 V 9 Ah.
- Efficiency: up to 94%.
- Display: 4.3-inch color touchscreen.
- Comms: Modbus and dry contacts, standard.

The lines every AUREON shares, from technology to warranty, are in the [AUREON key facts](https://www.aecups.com/us/products/aureon/#overview) and in the datasheet below.

Size and floor

## How big it is

14.9" W × 39.1" D × 49.2" H (378 × 993 × 1,250 mm); 750 lb (340.2 kg) net. It ships in one carton of 18 × 43.7 × 54.7 in, 900 lb (408.2 kg) gross.

**4.0 ft²** footprint (0.38 m²)

**185 lb/ft²** floor load of the cabinet alone

**Tower** form factor

Floor load = net weight ÷ footprint, without batteries outside the cabinet.

Datasheet

## AUR30-80X9A datasheet.

The AUR30-80X9A in the AEC 2026 catalog, figure by figure. [Compare it with every AUREON model](https://www.aecups.com/us/products/aureon/#datasheet).

**AUR30-80X9A datasheet**

| Parameter | AUR30-80X9A |
| --- | --- |
| Power |  |
| Rated power (kVA) | 30 |
| Active power (kW) | 30 |
| Output power factor | 1.0 |
| Electrical |  |
| Input / output | 208 V three-phase, 4-wire (3P+N) |
| Topology | Online Double Conversion |
| Efficiency, up to | 94% |
| Battery DC bus | 240 V DC |
| Battery and runtime |  |
| Battery type | VRLA (sealed lead-acid) |
| Battery configuration | Internal |
| Runtime at 50 % load | 14 min |
| Runtime at 100 % load | 4 min |
| Mechanical |  |
| Form factor | Tower |
| Dimensions W × D × H | 14.9 × 39.1 × 49.2 in (378 × 993 × 1,250 mm) |
| Net weight | 750 lb (340.2 kg) |
| Footprint | 4.0 ft² (0.38 m²) |
| Shipping |  |
| Cartons | 1 |
| Shipping weight | 900 lb |
| Common to every AUREON |  |
| Battery, AUR30-80X9A | internal hot-swappable VRLA, 80 × 12V 9Ah |
| Network card | SNMP-L (SNMP) |
| Warranty | 3 years on UPS · 2 years on VRLA batteries |
| Certification | [UL 1778](https://www.shopulstandards.com/ProductDetail.aspx?productId=UL1778) listed, UL file E543003 (AEC UPS USA LLC) |
| Quality system | ISO 9001:2015, the group's quality system (SGS) |

From the AEC 2026 catalog. Figures can change: the order confirmation rules.

Quick answers

## AUR30-80X9A: what people ask

#### What is the output current of the AUR30-80X9A?

83.3 A per phase at full load: 30 kVA ÷ (√3 × 208 V). Size the input breaker and the cables of the AUR30-80X9A from its installation manual and the local electrical code, not from this figure alone.

#### How much heat does the AUR30-80X9A give off?

About 2.0 kW, 6,770 BTU/h, at full load, where it is 93.8% efficient. Plan the room's cooling for a little more than that: the AUR30-80X9A is less efficient at part load and while its battery recharges.

#### Will the AUR30-80X9A fit through a standard door?

Yes: 14.9 in (378 mm) across its narrow side and 49.2 in (1,250 mm) high, it passes a standard 36 × 80-inch door upright. On the way in, check corridors, elevators and the floor load of the AUR30-80X9A (size section above).

The method, for any UPS: [runtime explained](https://www.aecups.com/us/blog/ups-runtime-explained/) · [amps from kVA](https://www.aecups.com/us/blog/ups-amps-from-kva/) · [heat output in BTU/h](https://www.aecups.com/us/blog/ups-heat-output-btu/)

AUREON

## Other AUREON models

[The AUREON series, with pictures](https://www.aecups.com/us/products/aureon/#models)

By power, the AUR30-80X9A is the largest in the AUREON series, which runs from 10 to 30 kVA. One size down are the [AUR-20](https://www.aecups.com/us/products/aureon/aur-20/), [AUR20-60X9A](https://www.aecups.com/us/products/aureon/aur20-60x9a/) and [AUR20-80X9A](https://www.aecups.com/us/products/aureon/aur20-80x9a/), all 10 kVA less. The same 30 kVA also comes as [AUR-30](https://www.aecups.com/us/products/aureon/aur-30/) (frame only, no batteries included: takes up to 80 internal 12 V 9 Ah VRLA blocks (20, 40, 60 or 80), 468 lb lighter); the AUR30-80X9A has internal batteries.

#### Every AUREON model side by side (8)

**AUREON models side by side**

| Model | Power | Power against this model | Net weight | Weight against this model | Runtime at 50 % load | Battery configuration |
| --- | --- | --- | --- | --- | --- | --- |
| [AUR-10](https://www.aecups.com/us/products/aureon/aur-10/) | 10 kVA | 20 kVA less | 231 lb | 519 lb lighter | — | Frame only, no batteries included: takes up to 80 internal 12 V 9 Ah VRLA blocks (20, 40, 60 or 80) |
| [AUR10-40X9A](https://www.aecups.com/us/products/aureon/aur10-40x9a/) | 10 kVA | 20 kVA less | 465 lb | 285 lb lighter | 25 min at 50 % load | Internal |
| [AUR10-80X9A](https://www.aecups.com/us/products/aureon/aur10-80x9a/) | 10 kVA | 20 kVA less | 699 lb | 51 lb lighter | 60 min at 50 % load | Internal |
| [AUR-20](https://www.aecups.com/us/products/aureon/aur-20/) | 20 kVA | 10 kVA less | 258 lb | 492 lb lighter | — | Frame only, no batteries included: takes up to 80 internal 12 V 9 Ah VRLA blocks (20, 40, 60 or 80) |
| [AUR20-60X9A](https://www.aecups.com/us/products/aureon/aur20-60x9a/) | 20 kVA | 10 kVA less | 609 lb | 141 lb lighter | 13.5 min at 50 % load, AEC estimate | Internal |
| [AUR20-80X9A](https://www.aecups.com/us/products/aureon/aur20-80x9a/) | 20 kVA | 10 kVA less | 726 lb | 24 lb lighter | 20 min at 50 % load, AEC estimate | Internal |
| [AUR-30](https://www.aecups.com/us/products/aureon/aur-30/) | 30 kVA | the same power | 282 lb | 468 lb lighter | — | Frame only, no batteries included: takes up to 80 internal 12 V 9 Ah VRLA blocks (20, 40, 60 or 80) |
| **AUR30-80X9A** | 30 kVA | this page | 750 lb | this page | 14 min at 50 % load | Internal |

Install and run it: [Guide specification, CSI 26 33 53](https://www.aecups.com/us/products/aureon-guide-specification/)

## The AUR30-80X9A for your project

Send the load, the voltage and the minutes you need from the AUR30-80X9A. We reply with the configuration, the batteries and the lead time.

[Send your project](https://www.aecups.com/us/contacts/?interest=UPS%20three-phase&msg=About%20the%20AUR30-80X9A%20(AUREON)%3A%20%0AQuantity%3A%20#form) [+1 786 553 2100](tel:+17865532100)