VRLA Online double conversion Tower

AUREON is AEC's online double-conversion UPS for three-phase 208 V loads from 10 to 30 kVA, in a tower cabinet, with VRLA batteries. Its 12 V 9 Ah VRLA blocks sit inside the tower and are hot-swappable: the models are sold with 40, 60 or 80, and every frame takes up to 80 (20, 40, 60 or 80).

**10–30** kVA

**94%** Efficiency, up to

**1.0** Power factor

**3 yr** Warranty

Datasheet Manuals and catalogs [Guide specification (CSI)](https://www.aecups.com/us/products/aureon-guide-specification/) [Contact us](https://www.aecups.com/us/contacts/?interest=UPS%20three-phase&msg=About%20the%20AUREON%3A%20%0AQuantity%3A%20#form)

Efficiency

## How efficient is the AUREON at your load?

The AUREON in normal double-conversion mode, from the 2026 catalog's efficiency curve. Drag along it to see the heat lost and its yearly cost.

**—** %

**Load**: —

**Lost as heat**: —

**Heat to remove**: —

**Energy lost in a year, 24/7**: —

**Its cost in a year at per kWh**: —

What is what

## Inside the AUREON, part by part.

Each number on the picture is named in the list.

### Rear, and the front with its door open

1. **Option slots and parallel port** Marked SLOT1, SLOT2 and PARALLEL; Modbus and dry contacts are standard.
2. **Fans and air outlet** The air enters at the front and leaves at the rear: never put the rear against a wall.
3. **Bypass breaker** The static bypass supply.
4. **Output breaker** To the load.
5. **BATT. Start** Cold start: powers the UPS up from its batteries when there is no mains.
6. **Maintenance breaker** Under its cover, normally OFF. Taking the cover off moves the load to bypass by itself.
7. **Input breaker** The rectifier's mains supply.
8. **Wiring cover** Behind it the AC terminal block, the PE bar and the external battery block (+, N, −). Cables enter from below.
9. **Touchscreen** 4.3-inch color touchscreen on the front.
10. **ON/OFF keys and EPO** Below the touchscreen.
11. **VRLA battery modules** Two to four, hot-swappable, fitted from the bottom up; empty positions closed with cover plates.
12. **Front door** Key-locked; keep it free to open fully, for the battery modules.

### Open it

AUREON closed

Overview

## Key facts

**Power range**: 10–30 kVA

**Input / Output**: 208 V, three-phase

**Battery**: VRLA batteries

**Power factor**: 1.0 (kVA = kW)

**Network card**: SNMP-L (SNMP)

**Warranty**: 3 years on UPS · 2 years on VRLA batteries

**Certification**: [UL 1778](https://www.shopulstandards.com/ProductDetail.aspx?productId=UL1778) listed, UL file E543003 (AEC UPS USA LLC)

**Quality system**: ISO 9001:2015, the group's quality system (SGS)

Models

## Which AUREON fits your load?

8 models for the US market, from the 2026 catalog. Pick the power, open a model for its full datasheet.

[**AUR-10** 10 kVA · 10 kW VRLA frame only **231 lb** net weight **Frame only, no batteries included: takes up to 80 internal 12 V 9 Ah VRLA blocks (20, 40, 60 or 80)** batteries Details and datasheet](https://www.aecups.com/us/products/aureon/aur-10/) [**AUR10-40X9A** 10 kVA · 10 kW 40 × 9 Ah VRLA **465 lb** net weight **Internal** batteries Details and datasheet](https://www.aecups.com/us/products/aureon/aur10-40x9a/) [**AUR10-80X9A** 10 kVA · 10 kW 80 × 9 Ah VRLA **699 lb** net weight **Internal** batteries Details and datasheet](https://www.aecups.com/us/products/aureon/aur10-80x9a/) [**AUR-20** 20 kVA · 20 kW VRLA frame only **258 lb** net weight **Frame only, no batteries included: takes up to 80 internal 12 V 9 Ah VRLA blocks (20, 40, 60 or 80)** batteries Details and datasheet](https://www.aecups.com/us/products/aureon/aur-20/) [**AUR20-60X9A** 20 kVA · 20 kW 60 × 9 Ah VRLA **609 lb** net weight **Internal** batteries Details and datasheet](https://www.aecups.com/us/products/aureon/aur20-60x9a/) [**AUR20-80X9A** 20 kVA · 20 kW 80 × 9 Ah VRLA **726 lb** net weight **Internal** batteries Details and datasheet](https://www.aecups.com/us/products/aureon/aur20-80x9a/) [**AUR-30** 30 kVA · 30 kW VRLA frame only **282 lb** net weight **Frame only, no batteries included: takes up to 80 internal 12 V 9 Ah VRLA blocks (20, 40, 60 or 80)** batteries Details and datasheet](https://www.aecups.com/us/products/aureon/aur-30/) [**AUR30-80X9A** 30 kVA · 30 kW 80 × 9 Ah VRLA **750 lb** net weight **Internal** batteries Details and datasheet](https://www.aecups.com/us/products/aureon/aur30-80x9a/)

Datasheet

## AUREON datasheet.

Every model side by side. Filter by power, keep only what differs, print it or take it as CSV.

**AUREON datasheet, 8 models**

| Model | [AUR-10](https://www.aecups.com/us/products/aureon/aur-10/) | [AUR10-40X9A](https://www.aecups.com/us/products/aureon/aur10-40x9a/) | [AUR10-80X9A](https://www.aecups.com/us/products/aureon/aur10-80x9a/) | [AUR-20](https://www.aecups.com/us/products/aureon/aur-20/) | [AUR20-60X9A](https://www.aecups.com/us/products/aureon/aur20-60x9a/) | [AUR20-80X9A](https://www.aecups.com/us/products/aureon/aur20-80x9a/) | [AUR-30](https://www.aecups.com/us/products/aureon/aur-30/) | [AUR30-80X9A](https://www.aecups.com/us/products/aureon/aur30-80x9a/) |
| --- | --- | --- | --- | --- | --- | --- | --- | --- |
| Power |  |  |  |  |  |  |  |  |
| Rated power (kVA) | 10 | 10 | 10 | 20 | 20 | 20 | 30 | 30 |
| Active power (kW) | 10 | 10 | 10 | 20 | 20 | 20 | 30 | 30 |
| Output power factor | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 |
| Electrical |  |  |  |  |  |  |  |  |
| Input / output | 208 V three-phase, 4-wire (3P+N) | 208 V three-phase, 4-wire (3P+N) | 208 V three-phase, 4-wire (3P+N) | 208 V three-phase, 4-wire (3P+N) | 208 V three-phase, 4-wire (3P+N) | 208 V three-phase, 4-wire (3P+N) | 208 V three-phase, 4-wire (3P+N) | 208 V three-phase, 4-wire (3P+N) |
| Topology | Online Double Conversion | Online Double Conversion | Online Double Conversion | Online Double Conversion | Online Double Conversion | Online Double Conversion | Online Double Conversion | Online Double Conversion |
| Efficiency, up to | 94% | 94% | 94% | 94% | 94% | 94% | 94% | 94% |
| Battery DC bus | 240 V DC | 240 V DC | 240 V DC | 240 V DC | 240 V DC | 240 V DC | 240 V DC | 240 V DC |
| Battery and runtime |  |  |  |  |  |  |  |  |
| Battery type | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) |
| Battery configuration | Frame only, no batteries included: takes up to 80 internal 12 V 9 Ah VRLA blocks (20, 40, 60 or 80) | Internal | Internal | Frame only, no batteries included: takes up to 80 internal 12 V 9 Ah VRLA blocks (20, 40, 60 or 80) | Internal | Internal | Frame only, no batteries included: takes up to 80 internal 12 V 9 Ah VRLA blocks (20, 40, 60 or 80) | Internal |
| Runtime at 50 % load | — | 25 min | 60 min | — | 13.5 min, AEC estimate | 20 min, AEC estimate | — | 14 min |
| Runtime at 100 % load | — | 7 min | 20 min | — | 4.5 min, AEC estimate | 7.5 min, AEC estimate | — | 4 min |
| Mechanical |  |  |  |  |  |  |  |  |
| Form factor | Tower | Tower | Tower | Tower | Tower | Tower | Tower | Tower |
| Dimensions W × D × H | 14.9 × 39.1 × 49.2 in (378 × 993 × 1,250 mm) | 14.9 × 39.1 × 49.2 in (378 × 993 × 1,250 mm) | 14.9 × 39.1 × 49.2 in (378 × 993 × 1,250 mm) | 14.9 × 39.1 × 49.2 in (378 × 993 × 1,250 mm) | 14.9 × 39.1 × 49.2 in (378 × 993 × 1,250 mm) | 14.9 × 39.1 × 49.2 in (378 × 993 × 1,250 mm) | 14.9 × 39.1 × 49.2 in (378 × 993 × 1,250 mm) | 14.9 × 39.1 × 49.2 in (378 × 993 × 1,250 mm) |
| Net weight | 231 lb (104.8 kg) | 465 lb (210.9 kg) | 699 lb (317.1 kg) | 258 lb (117 kg) | 609 lb (276.2 kg) | 726 lb (329.3 kg) | 282 lb (127.9 kg) | 750 lb (340.2 kg) |
| Footprint | 4.0 ft² (0.38 m²) | 4.0 ft² (0.38 m²) | 4.0 ft² (0.38 m²) | 4.0 ft² (0.38 m²) | 4.0 ft² (0.38 m²) | 4.0 ft² (0.38 m²) | 4.0 ft² (0.38 m²) | 4.0 ft² (0.38 m²) |
| Shipping |  |  |  |  |  |  |  |  |
| Cartons | — | 1 | — | — | 1 | — | — | 1 |
| Shipping weight | — | 558 lb | — | — | 731 lb | — | — | 900 lb |

From the AEC 2026 catalog. Efficiency is the catalog's “up to” figure; runtimes are AEC's runtime tables with new batteries; weights are the unit alone, without batteries outside it. Figures can change: the order confirmation rules.

Install and run it: [Guide specification, CSI 26 33 53](https://www.aecups.com/us/products/aureon-guide-specification/)

Plan it: [Size it for your load](https://www.aecups.com/us/tools/ups-sizing/) [Battery runtime](https://www.aecups.com/us/tools/battery-runtime/) [Room fit](https://www.aecups.com/us/tools/room-fit/) [AUREON compared with other makers](https://www.aecups.com/us/comparisons/lead-acid-three-phase-ups-10-30-kva-208v/) [Warranty terms](https://www.aecups.com/us/warranty/)

Replacing another brand's UPS? [Type its model number: the AEC match](https://www.aecups.com/us/cross-reference/)

AUREON: quick answers

## Questions people ask

#### What sizes does AUREON come in?

10 to 30 kVA, in 8 models of the 2026 catalog for the US, from the AUR-10 (10 kVA) to the AUR30-80X9A (30 kVA). The datasheet on this page gives every one.

#### What supply does AUREON need?

208 V, three-phase, for every model of the series. Its power factor is 1.0, so each model gives its kVA rating in kW.

#### What batteries does AUREON use?

VRLA batteries. The battery bus is 240 V DC on every model.

#### What warranty does AUREON have?

3 years on UPS; 2 years on VRLA batteries, from start-up. Register the UPS with AEC after start-up.

#### How is AUREON monitored over the network?

With the AEC SNMP-L network card, which reports the UPS status and alarms over SNMP to your monitoring software.

[What is the output current of each AUREON model?](https://www.aecups.com/us/faq/aureon/#q1) [How much heat does each AUREON model give off?](https://www.aecups.com/us/faq/aureon/#q2) [Which AUREON models fit through a standard door?](https://www.aecups.com/us/faq/aureon/#q3) [All 8 questions](https://www.aecups.com/us/faq/aureon/)

Also in 208V three-phase UPS: [ETHERNO](https://www.aecups.com/us/products/etherno/) [RADIANT](https://www.aecups.com/us/products/radiant/) [RADIANT-IB](https://www.aecups.com/us/products/radiant-ib/) [Compare the range](https://www.aecups.com/us/products/three-phase-ups-208v/)

Read next: [UPS maintenance checklist: monthly, quarterly, yearly](https://www.aecups.com/us/blog/ups-maintenance-checklist/) [How long will a UPS run? Battery runtime explained](https://www.aecups.com/us/blog/ups-runtime-explained/)

## The AUREON for your project

Send the load, the voltage and the minutes. We reply with the AUREON model that fits, its batteries and the lead time.

[Send your project](https://www.aecups.com/us/contacts/?interest=UPS%20three-phase&msg=About%20the%20AUREON%3A%20%0AQuantity%3A%20#form) [+1 786 553 2100](tel:+17865532100)