title: "CIRRO Modular UPS 60–1,600 kVA 480V 4W | AEC"
url: https://www.aecups.com/us/products/cirro/
description: "CIRRO is AEC's modular online UPS with N+X redundancy for three-phase 480 V, 4-wire loads from 60 to 1,600 kVA, with an external VRLA battery bank."
language: en-US
---

Three-phase 480 V UPS

# CIRRO modular UPS, 60–1,600 kVA, 480 V

4-wire · 3P+N VRLA Modular N+X Modular

CIRRO is AEC's modular online UPS with N+X redundancy for three-phase 480 V, 4-wire loads from 60 to 1,600 kVA, with an external VRLA battery bank. The 360 kVA frame takes 60 kVA modules; the 600, 800, 1,200 and 1,600 kVA frames take 100 kVA modules.

**60–1,600** kVA

**97%** Efficiency, up to

**1.0** Power factor

**3 yr** Warranty

Datasheet Manuals and catalogs [Contact us](https://www.aecups.com/us/contacts/?interest=UPS%20three-phase&msg=About%20the%20CIRRO%3A%20%0AQuantity%3A%20#form)

[**Try 3D** X-ray view](https://www.aecups.com/assets/models3d/cir/v52/)

Drag to turn

In 3D

## Look around the CIRRO

Drag it round, swipe on a phone or use the arrow keys. X-ray makes the enclosure see-through, so you can see what sits behind the panels.

[Open full 3D · X-ray](https://www.aecups.com/assets/models3d/cir/v52/)

Rendered from AEC's 3D model of the CIRRO 360–1,600 kVA. The full 3D view zooms in, opens the unit and names every part.

Hands on

## Open the CIRRO 1600 yourself.

Click the unit: the door opens. Drag to move it by hand. The 3D shows every part.

[Every part in 3D](https://www.aecups.com/assets/models3d/cir/v52/)

Efficiency

## How efficient is the CIRRO at your load?

The CIRRO in normal double-conversion mode, from the 2026 catalog's efficiency curve. Drag along it to see the heat lost and its yearly cost.

**—** %

**Load**: —

**Lost as heat**: —

**Heat to remove**: —

**Energy lost in a year, 24/7**: —

**Its cost in a year at per kWh**: —

The display

## The CIRRO display.

The real touchscreen, from the user manual: pick a main page, or touch the screen as on the UPS.

RADIANT · CIRRO · the real screen

### Home

The home page after the welcome window: status bar, output voltage gauges, battery bars, energy flow and warning information, with the main menu on the left.

**The ten main pages**

What is what

## Inside the CIRRO, part by part.

Each number on the picture is named in the list.

### Front, door open · 600 kVA

1. **Four breakers** Main input, output, bypass input and maintenance bypass, on the 600 and 800 kVA frames.
2. **100 kVA power modules** Hot-swappable. The 600 and 800 kVA frames take 6 or 8 of them.
3. **Control strip** Communication terminals, EPO and the parallel connections: RS-232, RS-485, USB, dry contacts and the intelligent slot.
4. **Bypass module** The static bypass of the frame, with its fans.

### Front, door open · 1,200 kVA

1. **100 kVA power modules** Hot-swappable. The 1,200 and 1,600 kVA frames take 12 or 16 of them.
2. **Control strip** Communication terminals, EPO and the parallel connections: RS-232, RS-485, USB, dry contacts and the intelligent slot.
3. **Bypass module** The static bypass, with its fans.

**CIRRO in 3D, door open** The door opens on what is inside. · 0:06

Overview

## Key facts

**Power range**: 60–1,600 kVA

**Technology**: 3-level IGBT; unity power factor (kVA = kW); 80 A settable charger

**Input / Output**: 480/277 V three-phase, 4-wire

**Display**: personalized AEC red color touchscreen

**Comms**: RS232, RS485, USB, dry contacts, intelligent slot and EPO standard; battery cold start

**Battery**: external VRLA battery bank

**Power factor**: 1.0 (kVA = kW)

**Network card**: SNMP-M (SNMP)

**Warranty**: 3 years on UPS · 2 years on VRLA batteries

**Quality system**: ISO 9001:2015, the group's quality system (SGS)

Models

## Which CIRRO fits your load?

21 models for the US market, from the 2026 catalog. Pick the power, open a model for its full datasheet.

[**CIR360-1X60** 60 kVA · 60 kW 1 × 60 kVA power module **636.4 lb** net weight **External battery bank** batteries Details and datasheet](https://www.aecups.com/us/products/cirro/cir360-1x60/) [**CIR600-1X100** 100 kVA · 100 kW 1 × 100 kVA power module **996.5 lb** net weight **External battery bank** batteries Details and datasheet](https://www.aecups.com/us/products/cirro/cir600-1x100/) [**CIR360-2X60** 120 kVA · 120 kW 2 × 60 kVA power modules **726.8 lb** net weight **External battery bank** batteries Details and datasheet](https://www.aecups.com/us/products/cirro/cir360-2x60/) [**CIR360-3X60** 180 kVA · 180 kW 3 × 60 kVA power modules **817.2 lb** net weight **External battery bank** batteries Details and datasheet](https://www.aecups.com/us/products/cirro/cir360-3x60/) [**CIR600-2X100** 200 kVA · 200 kW 2 × 100 kVA power modules **1,100.1 lb** net weight **External battery bank** batteries Details and datasheet](https://www.aecups.com/us/products/cirro/cir600-2x100/) [**CIR360-4X60** 240 kVA · 240 kW 4 × 60 kVA power modules **907.6 lb** net weight **External battery bank** batteries Details and datasheet](https://www.aecups.com/us/products/cirro/cir360-4x60/) [**CIR360-5X60** 300 kVA · 300 kW 5 × 60 kVA power modules **998 lb** net weight **External battery bank** batteries Details and datasheet](https://www.aecups.com/us/products/cirro/cir360-5x60/) [**CIR360-6X60** 360 kVA · 360 kW 6 × 60 kVA power modules **1,088.4 lb** net weight **External battery bank** batteries Details and datasheet](https://www.aecups.com/us/products/cirro/cir360-6x60/) [**CIR600-4X100** 400 kVA · 400 kW 4 × 100 kVA power modules **1,307.3 lb** net weight **External battery bank** batteries Details and datasheet](https://www.aecups.com/us/products/cirro/cir600-4x100/) [**CIR600-5X100** 500 kVA · 500 kW 5 × 100 kVA power modules **1,410.9 lb** net weight **External battery bank** batteries Details and datasheet](https://www.aecups.com/us/products/cirro/cir600-5x100/) [**CIR600-6X100** 600 kVA · 600 kW 6 × 100 kVA power modules **1,514.5 lb** net weight **External battery bank** batteries Details and datasheet](https://www.aecups.com/us/products/cirro/cir600-6x100/) [**CIR800-7X100** 700 kVA · 700 kW 7 × 100 kVA power modules **1,798.8 lb** net weight **External battery bank** batteries Details and datasheet](https://www.aecups.com/us/products/cirro/cir800-7x100/) [**CIR800-8X100** 800 kVA · 800 kW 8 × 100 kVA power modules **1,902.4 lb** net weight **External battery bank** batteries Details and datasheet](https://www.aecups.com/us/products/cirro/cir800-8x100/) [**CIR1200-9X100** 900 kVA · 900 kW 9 × 100 kVA power modules **2,308.1 lb** net weight **External battery bank** batteries Details and datasheet](https://www.aecups.com/us/products/cirro/cir1200-9x100/) [**CIR1200-10X100** 1,000 kVA · 1,000 kW 10 × 100 kVA power modules **2,411.7 lb** net weight **External battery bank** batteries Details and datasheet](https://www.aecups.com/us/products/cirro/cir1200-10x100/) [**CIR1200-11X100** 1,100 kVA · 1,100 kW 11 × 100 kVA power modules **2,515.3 lb** net weight **External battery bank** batteries Details and datasheet](https://www.aecups.com/us/products/cirro/cir1200-11x100/) [**CIR1200-12X100** 1,200 kVA · 1,200 kW 12 × 100 kVA power modules **2,618.9 lb** net weight **External battery bank** batteries Details and datasheet](https://www.aecups.com/us/products/cirro/cir1200-12x100/) [**CIR1600-13X100** 1,300 kVA · 1,300 kW 13 × 100 kVA power modules **3,485.3 lb** net weight **External battery bank** batteries Details and datasheet](https://www.aecups.com/us/products/cirro/cir1600-13x100/) [**CIR1600-14X100** 1,400 kVA · 1,400 kW 14 × 100 kVA power modules **3,588.9 lb** net weight **External battery bank** batteries Details and datasheet](https://www.aecups.com/us/products/cirro/cir1600-14x100/) [**CIR1600-15X100** 1,500 kVA · 1,500 kW 15 × 100 kVA power modules **3,692.5 lb** net weight **External battery bank** batteries Details and datasheet](https://www.aecups.com/us/products/cirro/cir1600-15x100/) [**CIR1600-16X100** 1,600 kVA · 1,600 kW 16 × 100 kVA power modules **3,796.1 lb** net weight **External battery bank** batteries Details and datasheet](https://www.aecups.com/us/products/cirro/cir1600-16x100/)

### Options and parts for CIRRO

- **CIR-PWR-100** Power Module 100 kVA — CIRRO 18.7" W × 27.8" D × 5.5" H (475 × 706 × 140 mm) · 103.6 lb (47 kg)
- **CIR-PWR-60** Power Module 60 kVA — CIRRO
- **CIR1200-FRAME** CIRRO 1,200 kVA Frame — no power module, 12 module slots for 100 kVA modules, NO breakers (external switchgear required) 47.2" W × 43.3" D × 78.7" H (1,199 × 1,100 × 1,999 mm) · 1,375.7 lb (624 kg)
- **CIR1600-FRAME** CIRRO 1,600 kVA Frame — no power module, 16 module slots for 100 kVA modules, NO breakers (external switchgear required) 63" W × 39.4" D × 78.7" H (1,600 × 1,001 × 1,999 mm) · 2,138.5 lb (970 kg)
- **CIR360-FRAME** CIRRO 360 kVA Frame — no power module, 6 module slots for 60 kVA modules, incl. 1 breaker 23.6" W × 39.4" D × 78.7" H (600 × 1,000 × 2,000 mm) · 559.4 lb (253.7 kg)
- **CIR600-FRAME** CIRRO 600 kVA Frame — no power module, 6 module slots for 100 kVA modules, incl. 4 breakers (main input, output, bypass input, maintenance bypass) 31.5" W × 39.4" D × 78.7" H (800 × 1,001 × 1,999 mm) · 892.9 lb (405 kg)
- **CIR800-FRAME** CIRRO 800 kVA Frame — no power module, 8 module slots for 100 kVA modules, incl. 4 breakers (main input, output, bypass input, maintenance bypass) 31.5" W × 39.4" D × 78.7" H (800 × 1,001 × 1,999 mm) · 1,073.6 lb (487 kg)

Datasheet

## CIRRO datasheet.

Every model side by side. Filter by power, keep only what differs, print it or take it as CSV.

**CIRRO datasheet, 21 models**

| Model | [CIR360-1X60](https://www.aecups.com/us/products/cirro/cir360-1x60/) | [CIR600-1X100](https://www.aecups.com/us/products/cirro/cir600-1x100/) | [CIR360-2X60](https://www.aecups.com/us/products/cirro/cir360-2x60/) | [CIR360-3X60](https://www.aecups.com/us/products/cirro/cir360-3x60/) | [CIR600-2X100](https://www.aecups.com/us/products/cirro/cir600-2x100/) | [CIR360-4X60](https://www.aecups.com/us/products/cirro/cir360-4x60/) | [CIR360-5X60](https://www.aecups.com/us/products/cirro/cir360-5x60/) | [CIR360-6X60](https://www.aecups.com/us/products/cirro/cir360-6x60/) | [CIR600-4X100](https://www.aecups.com/us/products/cirro/cir600-4x100/) | [CIR600-5X100](https://www.aecups.com/us/products/cirro/cir600-5x100/) | [CIR600-6X100](https://www.aecups.com/us/products/cirro/cir600-6x100/) | [CIR800-7X100](https://www.aecups.com/us/products/cirro/cir800-7x100/) | [CIR800-8X100](https://www.aecups.com/us/products/cirro/cir800-8x100/) | [CIR1200-9X100](https://www.aecups.com/us/products/cirro/cir1200-9x100/) | [CIR1200-10X100](https://www.aecups.com/us/products/cirro/cir1200-10x100/) | [CIR1200-11X100](https://www.aecups.com/us/products/cirro/cir1200-11x100/) | [CIR1200-12X100](https://www.aecups.com/us/products/cirro/cir1200-12x100/) | [CIR1600-13X100](https://www.aecups.com/us/products/cirro/cir1600-13x100/) | [CIR1600-14X100](https://www.aecups.com/us/products/cirro/cir1600-14x100/) | [CIR1600-15X100](https://www.aecups.com/us/products/cirro/cir1600-15x100/) | [CIR1600-16X100](https://www.aecups.com/us/products/cirro/cir1600-16x100/) |
| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |
| Power |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |
| Rated power (kVA) | 60 | 100 | 120 | 180 | 200 | 240 | 300 | 360 | 400 | 500 | 600 | 700 | 800 | 900 | 1,000 | 1,100 | 1,200 | 1,300 | 1,400 | 1,500 | 1,600 |
| Active power (kW) | 60 | 100 | 120 | 180 | 200 | 240 | 300 | 360 | 400 | 500 | 600 | 700 | 800 | 900 | 1,000 | 1,100 | 1,200 | 1,300 | 1,400 | 1,500 | 1,600 |
| Output power factor | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 |
| Electrical |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |
| Input / output | 480 V three-phase, 4-wire (3P+N) | 480 V three-phase, 4-wire (3P+N) | 480 V three-phase, 4-wire (3P+N) | 480 V three-phase, 4-wire (3P+N) | 480 V three-phase, 4-wire (3P+N) | 480 V three-phase, 4-wire (3P+N) | 480 V three-phase, 4-wire (3P+N) | 480 V three-phase, 4-wire (3P+N) | 480 V three-phase, 4-wire (3P+N) | 480 V three-phase, 4-wire (3P+N) | 480 V three-phase, 4-wire (3P+N) | 480 V three-phase, 4-wire (3P+N) | 480 V three-phase, 4-wire (3P+N) | 480 V three-phase, 4-wire (3P+N) | 480 V three-phase, 4-wire (3P+N) | 480 V three-phase, 4-wire (3P+N) | 480 V three-phase, 4-wire (3P+N) | 480 V three-phase, 4-wire (3P+N) | 480 V three-phase, 4-wire (3P+N) | 480 V three-phase, 4-wire (3P+N) | 480 V three-phase, 4-wire (3P+N) |
| Topology | Online double conversion, modular N+X | Online double conversion, modular N+X | Online double conversion, modular N+X | Online double conversion, modular N+X | Online double conversion, modular N+X | Online double conversion, modular N+X | Online double conversion, modular N+X | Online double conversion, modular N+X | Online double conversion, modular N+X | Online double conversion, modular N+X | Online double conversion, modular N+X | Online double conversion, modular N+X | Online double conversion, modular N+X | Online double conversion, modular N+X | Online double conversion, modular N+X | Online double conversion, modular N+X | Online double conversion, modular N+X | Online double conversion, modular N+X | Online double conversion, modular N+X | Online double conversion, modular N+X | Online double conversion, modular N+X |
| Efficiency, up to | 96% | 97% | 96% | 96% | 97% | 96% | 96% | 96% | 97% | 97% | 97% | 97% | 97% | 97% | 97% | 97% | 97% | 97% | 97% | 97% | 97% |
| Battery DC bus | 480 V DC | 480 V DC | 480 V DC | 480 V DC | 480 V DC | 480 V DC | 480 V DC | 480 V DC | 480 V DC | 480 V DC | 480 V DC | 480 V DC | 480 V DC | 480 V DC | 480 V DC | 480 V DC | 480 V DC | 480 V DC | 480 V DC | 480 V DC | 480 V DC |
| Battery and runtime |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |
| Battery type | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) |
| Battery configuration | External battery bank | External battery bank | External battery bank | External battery bank | External battery bank | External battery bank | External battery bank | External battery bank | External battery bank | External battery bank | External battery bank | External battery bank | External battery bank | External battery bank | External battery bank | External battery bank | External battery bank | External battery bank | External battery bank | External battery bank | External battery bank |
| Mechanical |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |
| Form factor | Modular | Modular | Modular | Modular | Modular | Modular | Modular | Modular | Modular | Modular | Modular | Modular | Modular | Modular | Modular | Modular | Modular | Modular | Modular | Modular | Modular |
| Dimensions W × D × H | 23.6 × 39.3 × 78.7 in (599 × 998 × 1,999 mm) | 31.5 × 39.4 × 78.7 in (800 × 1,001 × 1,999 mm) | 23.6 × 39.3 × 78.7 in (599 × 998 × 1,999 mm) | 23.6 × 39.3 × 78.7 in (599 × 998 × 1,999 mm) | 31.5 × 39.4 × 78.7 in (800 × 1,001 × 1,999 mm) | 23.6 × 39.3 × 78.7 in (599 × 998 × 1,999 mm) | 23.6 × 39.3 × 78.7 in (599 × 998 × 1,999 mm) | 23.6 × 39.3 × 78.7 in (599 × 998 × 1,999 mm) | 31.5 × 39.4 × 78.7 in (800 × 1,001 × 1,999 mm) | 31.5 × 39.4 × 78.7 in (800 × 1,001 × 1,999 mm) | 31.5 × 39.4 × 78.7 in (800 × 1,001 × 1,999 mm) | 31.5 × 39.4 × 78.7 in (800 × 1,001 × 1,999 mm) | 31.5 × 39.4 × 78.7 in (800 × 1,001 × 1,999 mm) | 47.2 × 43.3 × 78.7 in (1,199 × 1,100 × 1,999 mm) | 47.2 × 43.3 × 78.7 in (1,199 × 1,100 × 1,999 mm) | 47.2 × 43.3 × 78.7 in (1,199 × 1,100 × 1,999 mm) | 47.2 × 43.3 × 78.7 in (1,199 × 1,100 × 1,999 mm) | 63 × 39.4 × 78.7 in (1,600 × 1,001 × 1,999 mm) | 63 × 39.4 × 78.7 in (1,600 × 1,001 × 1,999 mm) | 63 × 39.4 × 78.7 in (1,600 × 1,001 × 1,999 mm) | 63 × 39.4 × 78.7 in (1,600 × 1,001 × 1,999 mm) |
| Net weight | 636.4 lb (288.7 kg) | 996.5 lb (452 kg) | 726.8 lb (329.7 kg) | 817.2 lb (370.7 kg) | 1,100.1 lb (499 kg) | 907.6 lb (411.7 kg) | 998 lb (452.7 kg) | 1,088.4 lb (493.7 kg) | 1,307.3 lb (593 kg) | 1,410.9 lb (640 kg) | 1,514.5 lb (687 kg) | 1,798.8 lb (815.9 kg) | 1,902.4 lb (862.9 kg) | 2,308.1 lb (1,046.9 kg) | 2,411.7 lb (1,093.9 kg) | 2,515.3 lb (1,140.9 kg) | 2,618.9 lb (1,187.9 kg) | 3,485.3 lb (1,580.9 kg) | 3,588.9 lb (1,627.9 kg) | 3,692.5 lb (1,674.9 kg) | 3,796.1 lb (1,721.9 kg) |
| Footprint | 6.4 ft² (0.60 m²) | 8.6 ft² (0.80 m²) | 6.4 ft² (0.60 m²) | 6.4 ft² (0.60 m²) | 8.6 ft² (0.80 m²) | 6.4 ft² (0.60 m²) | 6.4 ft² (0.60 m²) | 6.4 ft² (0.60 m²) | 8.6 ft² (0.80 m²) | 8.6 ft² (0.80 m²) | 8.6 ft² (0.80 m²) | 8.6 ft² (0.80 m²) | 8.6 ft² (0.80 m²) | 14.2 ft² (1.32 m²) | 14.2 ft² (1.32 m²) | 14.2 ft² (1.32 m²) | 14.2 ft² (1.32 m²) | 17.2 ft² (1.60 m²) | 17.2 ft² (1.60 m²) | 17.2 ft² (1.60 m²) | 17.2 ft² (1.60 m²) |
| Shipping |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |
| Cartons | 1 | — | 1 | 1 | — | 1 | 1 | 1 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| Shipping weight | 769.4 lb | — | 859.8 lb | 950.2 lb | — | 1,040.6 lb | 1,131 lb | 1,221.4 lb | — | — | — | — | — | — | — | — | — | — | — | — | — |

From the AEC 2026 catalog. Efficiency is the catalog's “up to” figure; weights are the unit alone, without batteries outside it. Figures can change: the order confirmation rules.

Install and run it: [RADIANT and CIRRO operating guide](https://www.aecups.com/us/support/guides/radiant-cirro/)

Plan it: [Size it for your load](https://www.aecups.com/us/tools/ups-sizing/) [Room fit](https://www.aecups.com/us/tools/room-fit/) [CIRRO compared with other makers](https://www.aecups.com/us/comparisons/modular-ups-480v-up-to-1600-kva/) [Warranty terms](https://www.aecups.com/us/warranty/)

Replacing another brand's UPS? [Type its model number: the AEC match](https://www.aecups.com/us/cross-reference/)

CIRRO: quick answers

## Questions people ask

#### What sizes does CIRRO come in?

60 to 1,600 kVA, in 21 models of the 2026 catalog for the US, from the CIR360-1X60 (60 kVA) to the CIR1600-16X100 (1,600 kVA). The datasheet on this page gives every one.

#### What supply does CIRRO need?

480/277 V three-phase, 4-wire, for every model of the series. Its power factor is 1.0, so each model gives its kVA rating in kW.

#### What batteries does CIRRO use?

External VRLA battery bank. The battery bus is 480 V DC on every model.

#### What warranty does CIRRO have?

3 years on UPS; 2 years on VRLA batteries, from start-up. Register the UPS with AEC after start-up.

#### How is CIRRO monitored over the network?

With the AEC SNMP-M network card, which reports the UPS status and alarms over SNMP to your monitoring software.

[How much power do CIRRO units give in parallel?](https://www.aecups.com/us/faq/cirro/#q4) [What is the output current of each CIRRO model?](https://www.aecups.com/us/faq/cirro/#q1) [How much heat does each CIRRO model give off?](https://www.aecups.com/us/faq/cirro/#q2) [All 9 questions](https://www.aecups.com/us/faq/cirro/)

Also in 480V three-phase UPS: [CIRRO-IB](https://www.aecups.com/us/products/cirro-ib/) [INFINITE](https://www.aecups.com/us/products/infinite/) [INFINITE 1.5MW](https://www.aecups.com/us/products/infinite-1-5mw/) [Compare the range](https://www.aecups.com/us/products/three-phase-ups-480v/)

Read next: [Growing a modular UPS: frames, modules and N+1](https://www.aecups.com/us/blog/modular-ups-growth-planning/) [ECO mode vs double conversion: what the load gives up](https://www.aecups.com/us/blog/ups-eco-mode/) [480 V UPS, 3-wire or 4-wire: the neutral explained](https://www.aecups.com/us/blog/480v-ups-3-wire-vs-4-wire/)

## The CIRRO for your project

Send the load, the voltage and the minutes. We reply with the CIRRO model that fits, its batteries and the lead time.

[Send your project](https://www.aecups.com/us/contacts/?interest=UPS%20three-phase&msg=About%20the%20CIRRO%3A%20%0AQuantity%3A%20#form) [+1 786 553 2100](tel:+17865532100)