# FERSPRT10000-16X9 FERRUS SP RT 10 kVA, 120/240V split-phase UPS

VRLA 10 kVA Online double conversion

The AEC FERRUS SP RT FERSPRT10000-16X9 is a 10 kVA / 10 kW online double-conversion UPS for 120/240 V split-phase loads, with a 3U rack cabinet of 16 × 12 V 9 Ah VRLA blocks, expandable with more cabinets. Kept at 80 % of its rating, it carries loads up to 8 kW.

**10 kVA / 10 kW** Rating

**17.3 × 22.8 × 8.5 in** W × D × H

**143 lb** Weight

**VRLA, 3U cabinet included** Battery

Technical data [Catalog (PDF)](https://www.aecups.com/docs/AEC_FERRUS_SP_RT_2026.pdf) [Contact us](https://www.aecups.com/us/contacts/?interest=UPS%20split-phase&msg=About%20the%20FERSPRT10000-16X9%20(FERRUS%20SP%20RT)%3A%20%0AQuantity%3A%20#form)

Series picture.

The same on every FERRUS SP RT: [The FERRUS SP RT display](https://www.aecups.com/us/products/ferrus-sp-rt/#display)

Load by load

## The FERSPRT10000-16X9 at 25, 50, 75 and 100 % load.

Its 10 kW rating in four steps, worked out from its own catalog figures.

**At 25, 50, 75 and 100 % load**

| Load | Output current on each leg | Efficiency | Heat to remove | Heat to remove (BTU/h) |
| --- | --- | --- | --- | --- |
| 25 % of the FERSPRT10000-16X9, 2.5 kW | 10.4 A on each leg | 90.8 % efficient | 253 W of heat | 860 BTU/h to cool |
| 50 % of the FERSPRT10000-16X9, 5.0 kW | 20.8 A on each leg | 92.8 % efficient | 388 W of heat | 1,320 BTU/h to cool |
| 75 % of the FERSPRT10000-16X9, 7.5 kW | 31.3 A on each leg | 93.0 % efficient | 565 W of heat | 1,930 BTU/h to cool |
| 100 % of the FERSPRT10000-16X9, 10 kW | 41.7 A on each leg | 92.8 % efficient | 776 W of heat | 2,650 BTU/h to cool |

Current = kVA × load ÷ volts.

Heat = load × (100 ÷ efficiency − 1); 1 kW is 3,412 BTU/h.

From the 2026 catalog

## What is the FERSPRT10000-16X9?

- Input / Output: 120/240 V split-phase
- Efficiency: Up to 93%
- Form: rack or tower, with an integrated isolation transformer
- Battery: 16 × 12 V 9 Ah VRLA blocks included, in their own rack cabinet
- Output: hardwired terminal block
- Rack space: 5U for the UPS and 3U for its battery cabinet, 8U in all

Size and floor

## How big it is

17.3" W × 22.8" D × 8.5" H (439 × 579 × 216 mm); 143 lb (64.9 kg) net. The catalog gives 143 lb (64.9 kg) for the FERSPRT10000-16X9, 123.6 lb (56.1 kg) for its 3U battery cabinet BAT16192RT, and 266.6 lb (120.9 kg) for the two together (FERSPRT10000-16X9+BAT16192RT).

**2.7 ft²** footprint (0.25 m²)

**52 lb/ft²** floor load of the cabinet alone

**Rack/tower, 19-inch rack** form factor

Floor load = net weight ÷ footprint, without batteries outside the cabinet.

Datasheet

## FERSPRT10000-16X9 datasheet.

The FERSPRT10000-16X9 in the AEC 2026 catalog, figure by figure. [Compare it with every FERRUS SP RT model](https://www.aecups.com/us/products/ferrus-sp-rt/#datasheet).

**FERSPRT10000-16X9 datasheet**

| Parameter | FERSPRT10000-16X9 |
| --- | --- |
| Power |  |
| Rated power (kVA) | 10 |
| Active power (kW) | 10 |
| Output power factor | 1.0 |
| Electrical |  |
| Input / output | 120/240 V split-phase |
| Topology | Online Double Conversion |
| Efficiency, up to | 93% |
| Battery DC bus | 192 V DC |
| Battery and runtime |  |
| Battery type | VRLA (sealed lead-acid) |
| Battery configuration | 3U rack cabinet with 16 × 12 V 9 Ah VRLA, included (UPS 5U + cabinet 3U, 8U in all); more cabinets can be added |
| Mechanical |  |
| Form factor | Rack/tower, 19-inch rack |
| Dimensions W × D × H | 17.3 × 22.8 × 8.5 in (439 × 579 × 216 mm) |
| Net weight | 143 lb (64.9 kg) |
| Footprint | 2.7 ft² (0.25 m²) |
| Common to every FERRUS SP RT |  |
| Battery | VRLA: each UPS comes with a 3U rack cabinet of 16 × 12 V 9 Ah blocks; more cabinets can be added |
| Network card | SNMP-M (SNMP) |
| Warranty | 3 years on UPS · 2 years on VRLA batteries |
| Quality system | ISO 9001:2015, the group's quality system (SGS) |

From the AEC 2026 catalog. Figures can change: the order confirmation rules.

Quick answers

## FERSPRT10000-16X9: what people ask

#### What is the output current of the FERSPRT10000-16X9?

41.7 A on each line at 240 V at full load: 10 kVA ÷ 240 V. Size the input breaker and the cables of the FERSPRT10000-16X9 from its installation manual and the local electrical code, not from this figure alone.

#### How much heat does the FERSPRT10000-16X9 give off?

About 776 W, 2,650 BTU/h, at full load, where it is 92.8% efficient. Plan the room's cooling for a little more than that: the FERSPRT10000-16X9 is less efficient at part load and while its battery recharges.

The method, for any UPS: [runtime explained](https://www.aecups.com/us/blog/ups-runtime-explained/) · [amps from kVA](https://www.aecups.com/us/blog/ups-amps-from-kva/) · [heat output in BTU/h](https://www.aecups.com/us/blog/ups-heat-output-btu/)

FERRUS SP RT

## Other FERRUS SP RT models

[The FERRUS SP RT series, with pictures](https://www.aecups.com/us/products/ferrus-sp-rt/#models)

By power, the FERSPRT10000-16X9 is the largest in the FERRUS SP RT series, which runs from 6 to 10 kVA. One size down is the [FERSPRT6000-16X9](https://www.aecups.com/us/products/ferrus-sp-rt/fersprt6000-16x9/) (4 kVA less; 15 lb lighter; 3U rack cabinet with 16 × 12 V 9 Ah VRLA, included (UPS 4U + cabinet 3U, 7U in all); more cabinets can be added).

#### Every FERRUS SP RT model side by side (2)

**FERRUS SP RT models side by side**

| Model | Power | Power against this model | Net weight | Weight against this model | Battery configuration |
| --- | --- | --- | --- | --- | --- |
| [FERSPRT6000-16X9](https://www.aecups.com/us/products/ferrus-sp-rt/fersprt6000-16x9/) | 6 kVA | 4 kVA less | 128 lb | 15 lb lighter | 3U rack cabinet with 16 × 12 V 9 Ah VRLA, included (UPS 4U + cabinet 3U, 7U in all); more cabinets can be added |
| **FERSPRT10000-16X9** | 10 kVA | this page | 143 lb | this page | 3U rack cabinet with 16 × 12 V 9 Ah VRLA, included (UPS 5U + cabinet 3U, 8U in all); more cabinets can be added |

## The FERSPRT10000-16X9 for your project

Send the load, the voltage and the minutes you need from the FERSPRT10000-16X9. We reply with the configuration, the batteries and the lead time.

[Send your project](https://www.aecups.com/us/contacts/?interest=UPS%20split-phase&msg=About%20the%20FERSPRT10000-16X9%20(FERRUS%20SP%20RT)%3A%20%0AQuantity%3A%20#form) [+1 786 553 2100](tel:+17865532100)