# FERSPRT6000-16X9 FERRUS SP RT 6 kVA, 120/240V split-phase UPS

VRLA 6 kVA Online double conversion

The AEC FERRUS SP RT FERSPRT6000-16X9 is a 6 kVA / 6 kW online double-conversion UPS for 120/240 V split-phase loads, with a 3U rack cabinet of 16 × 12 V 9 Ah VRLA blocks, expandable with more cabinets. Kept at 80 % of its rating, it carries loads up to 4.8 kW.

**6 kVA / 6 kW** Rating

**17.3 × 22.8 × 6.7 in** W × D × H

**128 lb** Weight

**VRLA, 3U cabinet included** Battery

Technical data [Catalog (PDF)](https://www.aecups.com/docs/AEC_FERRUS_SP_RT_2026.pdf) [Contact us](https://www.aecups.com/us/contacts/?interest=UPS%20split-phase&msg=About%20the%20FERSPRT6000-16X9%20(FERRUS%20SP%20RT)%3A%20%0AQuantity%3A%20#form)

Series picture.

The same on every FERRUS SP RT: [The FERRUS SP RT display](https://www.aecups.com/us/products/ferrus-sp-rt/#display)

Load by load

## The FERSPRT6000-16X9 at 25, 50, 75 and 100 % load.

Its 6.0 kW rating in four steps, worked out from its own catalog figures.

**At 25, 50, 75 and 100 % load**

| Load | Output current on each leg | Efficiency | Heat to remove | Heat to remove (BTU/h) |
| --- | --- | --- | --- | --- |
| 25 % of the FERSPRT6000-16X9, 1.5 kW | 6.3 A on each leg | 90.8 % efficient | 152 W of heat | 520 BTU/h to cool |
| 50 % of the FERSPRT6000-16X9, 3.0 kW | 12.5 A on each leg | 92.8 % efficient | 233 W of heat | 790 BTU/h to cool |
| 75 % of the FERSPRT6000-16X9, 4.5 kW | 18.8 A on each leg | 93.0 % efficient | 339 W of heat | 1,160 BTU/h to cool |
| 100 % of the FERSPRT6000-16X9, 6.0 kW | 25.0 A on each leg | 92.8 % efficient | 466 W of heat | 1,590 BTU/h to cool |

Current = kVA × load ÷ volts.

Heat = load × (100 ÷ efficiency − 1); 1 kW is 3,412 BTU/h.

From the 2026 catalog

## What is the FERSPRT6000-16X9?

- Input / Output: 120/240 V split-phase
- Efficiency: Up to 93%
- Form: rack or tower, with an integrated isolation transformer
- Battery: 16 × 12 V 9 Ah VRLA blocks included, in their own rack cabinet
- Output: hardwired terminal block
- Rack space: 4U for the UPS and 3U for its battery cabinet, 7U in all

Size and floor

## How big it is

17.3" W × 22.8" D × 6.7" H (439 × 579 × 170 mm); 128 lb (58.1 kg) net. The catalog gives 128 lb (58.1 kg) for the FERSPRT6000-16X9, 123.6 lb (56.1 kg) for its 3U battery cabinet BAT16192RT, and 251.6 lb (114.1 kg) for the two together (FERSPRT6000-16X9+BAT16192RT).

**2.7 ft²** footprint (0.25 m²)

**47 lb/ft²** floor load of the cabinet alone

**Rack/tower, 19-inch rack** form factor

Floor load = net weight ÷ footprint, without batteries outside the cabinet.

Datasheet

## FERSPRT6000-16X9 datasheet.

The FERSPRT6000-16X9 in the AEC 2026 catalog, figure by figure. [Compare it with every FERRUS SP RT model](https://www.aecups.com/us/products/ferrus-sp-rt/#datasheet).

**FERSPRT6000-16X9 datasheet**

| Parameter | FERSPRT6000-16X9 |
| --- | --- |
| Power |  |
| Rated power (kVA) | 6 |
| Active power (kW) | 6 |
| Output power factor | 1.0 |
| Electrical |  |
| Input / output | 120/240 V split-phase |
| Topology | Online Double Conversion |
| Efficiency, up to | 93% |
| Battery DC bus | 192 V DC |
| Battery and runtime |  |
| Battery type | VRLA (sealed lead-acid) |
| Battery configuration | 3U rack cabinet with 16 × 12 V 9 Ah VRLA, included (UPS 4U + cabinet 3U, 7U in all); more cabinets can be added |
| Mechanical |  |
| Form factor | Rack/tower, 19-inch rack |
| Dimensions W × D × H | 17.3 × 22.8 × 6.7 in (439 × 579 × 170 mm) |
| Net weight | 128 lb (58.1 kg) |
| Footprint | 2.7 ft² (0.25 m²) |
| Common to every FERRUS SP RT |  |
| Battery | VRLA: each UPS comes with a 3U rack cabinet of 16 × 12 V 9 Ah blocks; more cabinets can be added |
| Network card | SNMP-M (SNMP) |
| Warranty | 3 years on UPS · 2 years on VRLA batteries |
| Quality system | ISO 9001:2015, the group's quality system (SGS) |

From the AEC 2026 catalog. Figures can change: the order confirmation rules.

Quick answers

## FERSPRT6000-16X9: what people ask

#### What is the output current of the FERSPRT6000-16X9?

25.0 A on each line at 240 V at full load: 6.0 kVA ÷ 240 V. Size the input breaker and the cables of the FERSPRT6000-16X9 from its installation manual and the local electrical code, not from this figure alone.

#### How much heat does the FERSPRT6000-16X9 give off?

About 466 W, 1,590 BTU/h, at full load, where it is 92.8% efficient. Plan the room's cooling for a little more than that: the FERSPRT6000-16X9 is less efficient at part load and while its battery recharges.

The method, for any UPS: [runtime explained](https://www.aecups.com/us/blog/ups-runtime-explained/) · [amps from kVA](https://www.aecups.com/us/blog/ups-amps-from-kva/) · [heat output in BTU/h](https://www.aecups.com/us/blog/ups-heat-output-btu/)

FERRUS SP RT

## Other FERRUS SP RT models

[The FERRUS SP RT series, with pictures](https://www.aecups.com/us/products/ferrus-sp-rt/#models)

By power, the FERSPRT6000-16X9 is the smallest in the FERRUS SP RT series, which runs from 6 to 10 kVA. One size up is the [FERSPRT10000-16X9](https://www.aecups.com/us/products/ferrus-sp-rt/fersprt10000-16x9/) (4 kVA more; 15 lb heavier; 3U rack cabinet with 16 × 12 V 9 Ah VRLA, included (UPS 5U + cabinet 3U, 8U in all); more cabinets can be added).

#### Every FERRUS SP RT model side by side (2)

**FERRUS SP RT models side by side**

| Model | Power | Power against this model | Net weight | Weight against this model | Battery configuration |
| --- | --- | --- | --- | --- | --- |
| **FERSPRT6000-16X9** | 6 kVA | this page | 128 lb | this page | 3U rack cabinet with 16 × 12 V 9 Ah VRLA, included (UPS 4U + cabinet 3U, 7U in all); more cabinets can be added |
| [FERSPRT10000-16X9](https://www.aecups.com/us/products/ferrus-sp-rt/fersprt10000-16x9/) | 10 kVA | 4 kVA more | 143 lb | 15 lb heavier | 3U rack cabinet with 16 × 12 V 9 Ah VRLA, included (UPS 5U + cabinet 3U, 8U in all); more cabinets can be added |

## The FERSPRT6000-16X9 for your project

Send the load, the voltage and the minutes you need from the FERSPRT6000-16X9. We reply with the configuration, the batteries and the lead time.

[Send your project](https://www.aecups.com/us/contacts/?interest=UPS%20split-phase&msg=About%20the%20FERSPRT6000-16X9%20(FERRUS%20SP%20RT)%3A%20%0AQuantity%3A%20#form) [+1 786 553 2100](tel:+17865532100)