title: "2 kVA 120V single-phase UPS, 4 × 9 Ah VRLA: AEC FERRUS"
url: https://www.aecups.com/us/products/ferrus/fer2000-4x9/
description: "AEC FERRUS FER2000-4X9: 2 kVA / 2 kW online UPS for 120 V single-phase, internal VRLA batteries."
language: en-US
---

FERRUS · 120V single-phase UPS

# FER2000-4X9 FERRUS 2 kVA, 120V single-phase UPS

VRLA 2 kVA Online double conversion

The AEC FERRUS FER2000-4X9 is a 2 kVA / 2 kW online double-conversion UPS for 120 V single-phase loads, with internal VRLA batteries. Kept at 80 % of its rating, it carries loads up to 1.6 kW.

**2 kVA / 2 kW** Rating

**7.5 × 12.6 × 15.8 in** W × D × H

**36.3 lb** Weight

**VRLA, internal** Battery

Technical data [Catalog (PDF)](https://www.aecups.com/docs/AEC_FERRUS_2026.pdf) [Contact us](https://www.aecups.com/us/contacts/?interest=UPS%20single-phase&msg=About%20the%20FER2000-4X9%20(FERRUS)%3A%20%0AQuantity%3A%20#form)

Series picture.

Load by load

## The FER2000-4X9 at 25, 50, 75 and 100 % load.

Its 2.0 kW rating in four steps, worked out from its own catalog figures.

**At 25, 50, 75 and 100 % load**

| Load | Output current, at 120 V | Efficiency | Heat to remove | Heat to remove (BTU/h) |
| --- | --- | --- | --- | --- |
| 25 % of the FER2000-4X9, 500 W | 4.2 A at the output | 89.3 % efficient | 60 W of heat | 200 BTU/h to cool |
| 50 % of the FER2000-4X9, 1.0 kW | 8.3 A at the output | 92.5 % efficient | 81 W of heat | 280 BTU/h to cool |
| 75 % of the FER2000-4X9, 1.5 kW | 12.5 A at the output | 93.0 % efficient | 113 W of heat | 390 BTU/h to cool |
| 100 % of the FER2000-4X9, 2.0 kW | 16.7 A at the output | 92.8 % efficient | 155 W of heat | 530 BTU/h to cool |

Current = kVA × load ÷ volts.

Heat = load × (100 ÷ efficiency − 1); 1 kW is 3,412 BTU/h.

From the 2026 catalog

## What is the FER2000-4X9?

- Output: 2,000 VA / 2,000 W (unity power factor, kVA = kW).
- Battery: internal VRLA, 4 × 12 V 9 Ah (48 Vdc).
- Outlets: 8× NEMA 5-20R.

The lines every FERRUS shares, from technology to warranty, are in the [FERRUS key facts](https://www.aecups.com/us/products/ferrus/#overview) and in the datasheet below.

Size and floor

## How big it is

7.5" W × 12.6" D × 15.8" H (190 × 319 × 400 mm); 36.3 lb (16.5 kg) net. It ships in one carton of 13.4 × 21.3 × 18.5 in, 48.5 lb (22 kg) gross.

**0.7 ft²** footprint (0.06 m²)

**56 lb/ft²** floor load of the cabinet alone

**Tower** form factor

Floor load = net weight ÷ footprint, without batteries outside the cabinet.

Datasheet

## FER2000-4X9 datasheet.

The FER2000-4X9 in the AEC 2026 catalog, figure by figure. [Compare it with every FERRUS model](https://www.aecups.com/us/products/ferrus/#datasheet).

**FER2000-4X9 datasheet**

| Parameter | FER2000-4X9 |
| --- | --- |
| Power |  |
| Rated power (kVA) | 2 |
| Active power (kW) | 2 |
| Output power factor | 1.0 |
| Electrical |  |
| Input / output | 120 V single-phase |
| Topology | Online Double Conversion |
| Efficiency, up to | 93% |
| Battery DC bus | 48 V DC |
| Battery and runtime |  |
| Battery type | VRLA (sealed lead-acid) |
| Battery configuration | Internal |
| Runtime at 50 % load | 10 min |
| Runtime at 100 % load | 4.2 min |
| Mechanical |  |
| Form factor | Tower |
| Dimensions W × D × H | 7.5 × 12.6 × 15.8 in (190 × 319 × 400 mm) |
| Net weight | 36.3 lb (16.5 kg) |
| Footprint | 0.7 ft² (0.06 m²) |
| Shipping |  |
| Cartons | 1 |
| Shipping weight | 48.5 lb |
| Common to every FERRUS |  |
| Technology | 3-level IGBT; MOV surge protection; 8 A settable charger |
| Display | color LCD |
| Comms | RS-232, EPO and USB, standard |
| Battery, FER2000-4X9 | internal VRLA, 4 × 12V 9Ah (48 Vdc) |
| Network card | SNMP-M (SNMP) |
| Warranty | 3 years on UPS · 2 years on VRLA batteries |
| Quality system | ISO 9001:2015, the group's quality system (SGS) |

From the AEC 2026 catalog. Figures can change: the order confirmation rules.

Quick answers

## FER2000-4X9: what people ask

#### What is the output current of the FER2000-4X9?

16.7 A at 120 V at full load: 2.0 kVA ÷ 120 V. Size the input breaker and the cables of the FER2000-4X9 from its installation manual and the local electrical code, not from this figure alone.

#### How much heat does the FER2000-4X9 give off?

About 155 W, 530 BTU/h, at full load, where it is 92.8% efficient. Plan the room's cooling for a little more than that: the FER2000-4X9 is less efficient at part load and while its battery recharges.

The method, for any UPS: [runtime explained](https://www.aecups.com/us/blog/ups-runtime-explained/) · [amps from kVA](https://www.aecups.com/us/blog/ups-amps-from-kva/) · [heat output in BTU/h](https://www.aecups.com/us/blog/ups-heat-output-btu/)

FERRUS

## Other FERRUS models

[The FERRUS series, with pictures](https://www.aecups.com/us/products/ferrus/#models)

By power, the FER2000-4X9 is number 2 of 3 in the FERRUS series, which runs from 1 to 3 kVA. One size down is the [FER1000-2X9](https://www.aecups.com/us/products/ferrus/fer1000-2x9/) (1 kVA less and 20 lb lighter). One size up is the [FER3000-6X9](https://www.aecups.com/us/products/ferrus/fer3000-6x9/) (1 kVA more and 9 lb heavier).

#### Every FERRUS model side by side (3)

**FERRUS models side by side**

| Model | Power | Power against this model | Net weight | Weight against this model | Runtime at 50 % load |
| --- | --- | --- | --- | --- | --- |
| [FER1000-2X9](https://www.aecups.com/us/products/ferrus/fer1000-2x9/) | 1 kVA | 1 kVA less | 17 lb | 20 lb lighter | 10 min at 50 % load |
| **FER2000-4X9** | 2 kVA | this page | 36 lb | this page | 10 min at 50 % load |
| [FER3000-6X9](https://www.aecups.com/us/products/ferrus/fer3000-6x9/) | 3 kVA | 1 kVA more | 45 lb | 9 lb heavier | 10 min at 50 % load |

## The FER2000-4X9 for your project

Send the load, the voltage and the minutes you need from the FER2000-4X9. We reply with the configuration, the batteries and the lead time.

[Send your project](https://www.aecups.com/us/contacts/?interest=UPS%20single-phase&msg=About%20the%20FER2000-4X9%20(FERRUS)%3A%20%0AQuantity%3A%20#form) [+1 786 553 2100](tel:+17865532100)