title: "AEC LUMINA: 2U lithium rack online UPS, 1–3 kVA, 120 V"
url: https://www.aecups.com/us/products/lumina/
description: "LUMINA is AEC's online double-conversion UPS for single-phase 120 V loads from 1 to 3 kVA, in a 19-inch rack, with internal LiFePO4 lithium batteries."
language: en-US
---

Single-phase 120 V UPS

# LUMINA online UPS, 1–3 kVA, 120 V

Lithium Online double conversion Rack

LUMINA is AEC's online double-conversion UPS for single-phase 120 V loads from 1 to 3 kVA, in a 19-inch rack, with internal LiFePO4 lithium batteries. The battery sits inside the 2U chassis, the color LCD rotates, and RS232, EPO and USB are standard; a telescopic rail kit is available.

**1–3** kVA

**92.6%** Efficiency, up to

**0.9** Power factor

**5 yr** Warranty

Datasheet Manuals and catalogs [Contact us](https://www.aecups.com/us/contacts/?interest=UPS%20single-phase&msg=About%20the%20LUMINA%3A%20%0AQuantity%3A%20#form)

[**Try 3D** X-ray view](https://www.aecups.com/assets/models3d/lum/v67/)

Drag to turn

In 3D

## Look around the LUMINA

Drag it round, swipe on a phone or use the arrow keys. X-ray makes the enclosure see-through, so you can see what sits behind the panels.

[Open full 3D · X-ray](https://www.aecups.com/assets/models3d/lum/v67/)

Rendered from AEC's 3D model of the LUMINA 1–3 kVA. The full 3D view zooms in, opens the unit and names every part.

Efficiency

## How efficient is the LUMINA at your load?

The LUMINA in normal double-conversion mode, from the 2026 catalog's efficiency curve. Drag along it to see the heat lost and its yearly cost.

**—** %

**Load**: —

**Lost as heat**: —

**Heat to remove**: —

**Energy lost in a year, 24/7**: —

**Its cost in a year at per kWh**: —

Runtime

## How long does each LUMINA model run at your load?

From the 2026 catalog's runtime tables, new batteries. Drag the load, type it in kW, or move along the chart. Click a model for its page.

50 %

LUMINA 1 kVA · LiFePO4 inside and 3 more, same minutes LUMINA 2.2 kVA · LiFePO4, extended runtime

At 50 % of the rating

LUMINA 1 kVA

[**LiFePO4 inside **27 min**](https://www.aecups.com/us/products/lumina/lum1000rt-2u-li/)

LUMINA 1.5 kVA

[**LiFePO4 inside **27 min**](https://www.aecups.com/us/products/lumina/lum1500rt-2u-li/)

LUMINA 2 kVA

[**LiFePO4 inside **27 min**](https://www.aecups.com/us/products/lumina/lum2000rt-2u-li/)

LUMINA 2.2 kVA

[**LiFePO4, extended runtime **46 min**](https://www.aecups.com/us/products/lumina/lum2200rt-2u-li/)

LUMINA 3 kVA

[**LiFePO4 inside **27 min**](https://www.aecups.com/us/products/lumina/lum3000rt-2u-li/)

#### Table: every model at 25, 50, 75 and 100 % load

| Model | 25% load | 50% load | 75% load | 100% load |
| --- | --- | --- | --- | --- |
| [LUMINA 1 kVA · LiFePO4 inside](https://www.aecups.com/us/products/lumina/lum1000rt-2u-li/) LUM1000RT-2U-LI | 55 min | 27 min | 19 min | 11 min |
| [LUMINA 1.5 kVA · LiFePO4 inside](https://www.aecups.com/us/products/lumina/lum1500rt-2u-li/) LUM1500RT-2U-LI | 55 min | 27 min | 19 min | 11 min |
| [LUMINA 2 kVA · LiFePO4 inside](https://www.aecups.com/us/products/lumina/lum2000rt-2u-li/) LUM2000RT-2U-LI | 55 min | 27 min | 19 min | 11 min |
| [LUMINA 2.2 kVA · LiFePO4, extended runtime](https://www.aecups.com/us/products/lumina/lum2200rt-2u-li/) LUM2200RT-2U-LI | 98 min | 46 min | 34.5 min | 23 min |
| [LUMINA 3 kVA · LiFePO4 inside](https://www.aecups.com/us/products/lumina/lum3000rt-2u-li/) LUM3000RT-2U-LI | 55 min | 27 min | 19 min | 11 min |

The display

## The LUMINA display.

The real screen, from the user manual: its guided tours, step by step.

The display reads OUTPUT 120 Vac

### Inverter off and back on

Step 1 of 4

The UPS runs online on mains.

**You see** Mains icon lit, OUTPUT 120 Vac.

What is what

## Inside the LUMINA, part by part.

Each number on the picture is named in the list.

### Rear · 1 kVA

1. **Intelligent slot** For an SNMP network card or a dry-contact card; the -NC models ship with the SNMP card fitted.
2. **Cooling fan** One fan on the 1 kVA; the air leaves at the rear.
3. **EPO** Emergency power off contact.
4. **USB port** To a computer, for the monitoring and shutdown software.
5. **Circuit protector** The input breaker: press it to reset after an overload.
6. **Input: C14 inlet** IEC C14 inlet for the supply cord.
7. **8 × NEMA 5-15R outlets** The protected outputs, 120 V.
8. **Battery connector** DC input of the internal battery.

### Rear · 1.5–2.2 kVA

1. **Intelligent slot** For an SNMP network card or a dry-contact card; the -NC models ship with the SNMP card fitted.
2. **Two cooling fans** Two fans on the 1.5, 2, 2.2 and 3 kVA; the air leaves at the rear.
3. **EPO** Emergency power off contact.
4. **USB port** To a computer, for the monitoring and shutdown software.
5. **Circuit protector** The input breaker: press it to reset after an overload.
6. **Input: C20 inlet + 5 ft cord** IEC C20 inlet; the 5 ft supply cord plugs in with its C19 connector.
7. **6 × NEMA 5-20R outlets** The protected outputs, 120 V, 20 A receptacles.
8. **Battery connector** DC input of the internal battery.

### Rear · 3 kVA

1. **Intelligent slot** For an SNMP network card or a dry-contact card; the -NC models ship with the SNMP card fitted.
2. **Two cooling fans** Two fans on the 1.5, 2, 2.2 and 3 kVA; the air leaves at the rear.
3. **EPO** Emergency power off contact.
4. **USB port** To a computer, for the monitoring and shutdown software.
5. **Circuit protector** The input breaker: press it to reset after an overload.
6. **Input: NEMA L5-30P plug** Locking 30 A plug on a 5 ft cord.
7. **1 × NEMA L5-30R outlet** A locking 30 A output for the larger load.
8. **4 × NEMA 5-20R outlets** The protected outputs, 120 V, 20 A receptacles.
9. **Battery connector** DC input of the internal battery.

Overview

## Key facts

**Power range**: 1–3 kVA

**Input / Output**: 110/120 V, 50–60 Hz, single-phase

**Battery**: internal LiFePO4 lithium — about 2.6 times the full-load runtime of the VRLA FERRUS RT of the same rating at 1, 2 and 3 kVA (11 against 4.2 min), about 1.8 times at 1.5 kVA (11 against 6 min), each at its own full load, 12–15 year life (3,000 cycles)

**Display**: rotating color LCD

**Comms**: RS-232, EPO and USB, standard

**Form factor**: 2U rack; telescopic rail kit available

**Power factor**: 0.9

**Network card**: SNMP-L (SNMP)

**Warranty**: 5 years incl. lithium batteries

**Certification**: ETL Listed to [UL 1778](https://www.shopulstandards.com/ProductDetail.aspx?productId=UL1778) and CSA C22.2 No. 107.3

**Quality system**: ISO 9001:2015, the group's quality system (SGS)

Models

## Which LUMINA fits your load?

5 models for the US market, from the 2026 catalog. Pick the power, open a model for its full datasheet.

[**LUM1000RT-2U-LI** 1 kVA · 0.9 kW rack 2U, lithium LiFePO4 **27 min** at 50 % load **19.6 lb** net weight Details and datasheet](https://www.aecups.com/us/products/lumina/lum1000rt-2u-li/) [**LUM1500RT-2U-LI** 1.5 kVA · 1.35 kW rack 2U, lithium LiFePO4 **27 min, AEC estimate** at 50 % load **32.4 lb** net weight Details and datasheet](https://www.aecups.com/us/products/lumina/lum1500rt-2u-li/) [**LUM2000RT-2U-LI** 2 kVA · 1.8 kW rack 2U, lithium LiFePO4 **27 min** at 50 % load **30 lb** net weight Details and datasheet](https://www.aecups.com/us/products/lumina/lum2000rt-2u-li/) [**LUM2200RT-2U-LI** 2.2 kVA · 1.98 kW rack 2U, lithium LiFePO4 **46 min** at 50 % load **42.1 lb** net weight Details and datasheet](https://www.aecups.com/us/products/lumina/lum2200rt-2u-li/) [**LUM3000RT-2U-LI** 3 kVA · 2.7 kW rack 2U, lithium LiFePO4 **27 min** at 50 % load **37.7 lb** net weight Details and datasheet](https://www.aecups.com/us/products/lumina/lum3000rt-2u-li/)

Datasheet

## LUMINA datasheet.

Every model side by side. Filter by power, keep only what differs, print it or take it as CSV.

**LUMINA datasheet, 5 models**

| Model | [LUM1000RT-2U-LI](https://www.aecups.com/us/products/lumina/lum1000rt-2u-li/) | [LUM1500RT-2U-LI](https://www.aecups.com/us/products/lumina/lum1500rt-2u-li/) | [LUM2000RT-2U-LI](https://www.aecups.com/us/products/lumina/lum2000rt-2u-li/) | [LUM2200RT-2U-LI](https://www.aecups.com/us/products/lumina/lum2200rt-2u-li/) | [LUM3000RT-2U-LI](https://www.aecups.com/us/products/lumina/lum3000rt-2u-li/) |
| --- | --- | --- | --- | --- | --- |
| Power |  |  |  |  |  |
| Rated power (kVA) | 1 | 1.5 | 2 | 2.2 | 3 |
| Active power (kW) | 0.9 | 1.35 | 1.8 | 1.98 | 2.7 |
| Output power factor | 0.9 | 0.9 | 0.9 | 0.9 | 0.9 |
| Electrical |  |  |  |  |  |
| Input / output | 120 V single-phase | 120 V single-phase | 120 V single-phase | 120 V single-phase | 120 V single-phase |
| Topology | Online Double Conversion | Online Double Conversion | Online Double Conversion | Online Double Conversion | Online Double Conversion |
| Efficiency, up to | 91.7% | 92.5% | 92.5% | 92.6% | 92.5% |
| Battery DC bus | 24 V DC | 48 V DC | 48 V DC | 72 V DC | 72 V DC |
| Battery and runtime |  |  |  |  |  |
| Battery type | Lithium LiFePO4 | Lithium LiFePO4 | Lithium LiFePO4 | Lithium LiFePO4 | Lithium LiFePO4 |
| Battery configuration | Internal | Internal | Internal | Internal | Internal |
| Runtime at 50 % load | 27 min | 27 min, AEC estimate | 27 min | 46 min | 27 min |
| Runtime at 100 % load | 11 min | 11 min | 11 min | 23 min | 11 min |
| Mechanical |  |  |  |  |  |
| Form factor | Rack 2U | Rack 2U | Rack 2U | Rack 2U | Rack 2U |
| Dimensions W × D × H | 17.2 × 16.5 × 3.4 in (438 × 420 × 87 mm) | 17.2 × 22.6 × 3.4 in (437 × 574 × 86 mm) | 17.2 × 22.4 × 3.4 in (438 × 570 × 87 mm) | 17.2 × 24.2 × 3.4 in (438 × 615 × 87 mm) | 17.2 × 22.4 × 3.4 in (438 × 570 × 87 mm) |
| Net weight | 19.6 lb (8.9 kg) | 32.4 lb (14.7 kg) | 30 lb (13.6 kg) | 42.1 lb (19.1 kg) | 37.7 lb (17.1 kg) |
| Footprint | 2.0 ft² (0.18 m²) | 2.7 ft² (0.25 m²) | 2.7 ft² (0.25 m²) | 2.9 ft² (0.27 m²) | 2.7 ft² (0.25 m²) |
| Shipping |  |  |  |  |  |
| Cartons | 1 | — | 1 | 1 | 1 |
| Shipping weight | 33.5 lb | — | 44.5 lb | 57.1 lb | 51.4 lb |

From the AEC 2026 catalog. Efficiency is the catalog's “up to” figure; runtimes are AEC's runtime tables with new batteries; weights are the unit alone, without batteries outside it. Figures can change: the order confirmation rules.

Install and run it: [LUMINA operating guide](https://www.aecups.com/us/support/guides/lumina/)

Plan it: [Size it for your load](https://www.aecups.com/us/tools/ups-sizing/) [Battery runtime](https://www.aecups.com/us/tools/battery-runtime/) [Room fit](https://www.aecups.com/us/tools/room-fit/) [LUMINA compared with other makers](https://www.aecups.com/us/comparisons/rack-ups-1-3-kva-120v/) [Warranty terms](https://www.aecups.com/us/warranty/)

Replacing another brand's UPS? [Type its model number: the AEC match](https://www.aecups.com/us/cross-reference/)

LUMINA: quick answers

## Questions people ask

#### How long does LUMINA run on battery?

The LUM1000RT-2U-LI, LUM2000RT-2U-LI and LUM3000RT-2U-LI run 11 min at full load and 27 min at half load. The LUM1500RT-2U-LI runs 11 min at full load and 27 min at half load (AEC estimate). The LUM2200RT-2U-LI runs 23 min at full load and 46 min at half load. Figures from the 2026 catalog runtime tables, with new batteries.

#### How many watts does LUMINA deliver?

Its power factor is 0.9, so watts are 90 % of the VA: 1,000 VA gives 900 W, 1,500 VA gives 1,350 W, 2,000 VA gives 1,800 W, 2,200 VA gives 1,980 W, 3,000 VA gives 2,700 W.

#### How much rack space does LUMINA take?

2U of a 19-inch rack: 3.4 in high, 16.5 to 24.2 in deep depending on the model, with a telescopic rail kit available. Check the rack's usable depth before you order.

#### What warranty does LUMINA have?

5 years including the lithium batteries, from start-up. LUMINA is ETL Listed, as the 2026 catalog shows.

[How long does each LUMINA model run on battery?](https://www.aecups.com/us/faq/lumina/#q1) [What is the output current of each LUMINA model?](https://www.aecups.com/us/faq/lumina/#q2) [How much heat does each LUMINA model give off?](https://www.aecups.com/us/faq/lumina/#q3) [All 8 questions](https://www.aecups.com/us/faq/lumina/)

LUMINA in the field: [115 LUMINA UPS for the DeSoto County school servers](https://www.aecups.com/us/projects/lumina-lithium-desoto-county-schools/) [LUMINA and FERRUS SP for MARTA's data rooms in Atlanta](https://www.aecups.com/us/projects/lumina-ferrus-sp-marta-atlanta/) [LUMINA and RADIANT-IB UPS at a Dominican resort](https://www.aecups.com/us/projects/lumina-radiant-dominican-resort/) [All projects](https://www.aecups.com/us/projects/)

Also in 120V single-phase UPS: [FERRUS](https://www.aecups.com/us/products/ferrus/) [FERRUS RT](https://www.aecups.com/us/products/ferrus-rt/) [Compare the range](https://www.aecups.com/us/products/single-phase-ups-120v/)

Read next: [kVA vs kW: what a UPS rating really means](https://www.aecups.com/us/blog/kva-vs-kw-ups/) [Rack-mount UPS: depth, weight, lithium vs VRLA](https://www.aecups.com/us/blog/rack-mount-ups/) [How to choose a UPS: six questions to one model](https://www.aecups.com/us/blog/choosing-the-right-ups/)

## The LUMINA for your project

Send the load, the voltage and the minutes. We reply with the LUMINA model that fits, its batteries and the lead time.

[Send your project](https://www.aecups.com/us/contacts/?interest=UPS%20single-phase&msg=About%20the%20LUMINA%3A%20%0AQuantity%3A%20#form) [+1 786 553 2100](tel:+17865532100)