---
title: "2 kVA 120V single-phase lithium UPS: AEC LUM2000RT-2U-LI"
url: https://www.aecups.com/us/products/lumina/lum2000rt-2u-li/
description: "AEC LUMINA LUM2000RT-2U-LI: 2 kVA / 1.8 kW online UPS for 120 V single-phase, internal LiFePO4 lithium batteries. 11 min at full load, 27 min at half load."
language: en-US
---

LUMINA · 120V single-phase UPS

# LUM2000RT-2U-LI LUMINA 2 kVA, 120V single-phase UPS

Lithium 2 kVA Online double conversion

The AEC LUMINA LUM2000RT-2U-LI is a 2 kVA / 1.8 kW online double-conversion UPS for 120 V single-phase loads, with internal LiFePO4 lithium batteries: 11 minutes at full load, 27 at half load. Kept at 80 % of its rating, it carries loads up to 1.4 kW.

**2 kVA / 1.8 kW** Rating

**17.2 × 22.4 × 3.4 in** W × D × H

**30 lb** Weight

**Lithium, internal** Battery

Technical data [Catalog (PDF)](https://www.aecups.com/docs/AEC_LUMINA_2026.pdf) [Contact us](https://www.aecups.com/us/contacts/?interest=UPS%20single-phase&msg=About%20the%20LUM2000RT-2U-LI%20(LUMINA)%3A%20%0AQuantity%3A%20#form)

[**Try 3D** X-ray view](https://www.aecups.com/assets/models3d/lum/v67/#lum2)

Drag to turn

In 3D

## Look around the LUM2000RT-2U-LI

[Open full 3D · X-ray](https://www.aecups.com/assets/models3d/lum/v67/#lum2)

The same on every LUMINA: [The LUMINA display](https://www.aecups.com/us/products/lumina/#display)

Runtime

## LUMINA 2 kVA · LiFePO4 inside at your load.

The same chart as the [LUMINA page](https://www.aecups.com/us/products/lumina/#runtime): this model in bold, the other set-ups faded behind it to compare. 2026 catalog, new batteries.

50 %

LUMINA 1 kVA · LiFePO4 inside and 3 more, same minutes LUMINA 2.2 kVA · LiFePO4, extended runtime

At 50 % of the rating

LUMINA 2 kVA

**This model LiFePO4 inside **27 min**

LUMINA 1 kVA

[**LiFePO4 inside **27 min**](https://www.aecups.com/us/products/lumina/lum1000rt-2u-li/)

LUMINA 1.5 kVA

[**LiFePO4 inside **27 min**](https://www.aecups.com/us/products/lumina/lum1500rt-2u-li/)

LUMINA 2.2 kVA

[**LiFePO4, extended runtime **46 min**](https://www.aecups.com/us/products/lumina/lum2200rt-2u-li/)

LUMINA 3 kVA

[**LiFePO4 inside **27 min**](https://www.aecups.com/us/products/lumina/lum3000rt-2u-li/)

#### Table: this model at 25, 50, 75 and 100 % load

| Model | 25% load | 50% load | 75% load | 100% load |
| --- | --- | --- | --- | --- |
| **LUMINA 2 kVA · LiFePO4 inside** LUM2000RT-2U-LI | 55 min | 27 min | 19 min | 11 min |

[Every LUMINA set-up in one table](https://www.aecups.com/us/products/lumina/#runtime)

From the 2026 catalog

## What is the LUM2000RT-2U-LI?

- Output: 2,000 VA / 1,800 W (power factor 0.9).
- Input: IEC C20 inlet, power cord with NEMA 5-20P plug supplied.
- Battery: internal LiFePO4 lithium, 10.2 Ah · 489.6 Wh — 11 min at full load, against 4.2 min for the VRLA FERRUS RT of the same kVA, each at its own full load, 12–15 year life (3,000 cycles).
- Efficiency: up to 92.5%.
- Outlets: 6× NEMA 5-20R.

The lines every LUMINA shares, from technology to warranty, are in the [LUMINA key facts](https://www.aecups.com/us/products/lumina/#overview) and in the datasheet below.

Size and floor

## How big it is

17.2" W × 22.4" D × 3.4" H (438 × 570 × 87 mm); 30 lb (13.6 kg) net. It ships in one carton of 21.5 × 27.7 × 9.6 in, 44.5 lb (20.2 kg) gross.

**2.7 ft²** footprint (0.25 m²)

**11 lb/ft²** floor load of the cabinet alone

**Rack 2U** form factor

Floor load = net weight ÷ footprint, without batteries outside the cabinet.

What is what

## Inside the LUMINA, part by part.

Each number on the picture is named in the list.

### Rear · 1 kVA

1. **Intelligent slot** For an SNMP network card or a dry-contact card; the -NC models ship with the SNMP card fitted.
2. **Cooling fan** One fan on the 1 kVA; the air leaves at the rear.
3. **EPO** Emergency power off contact.
4. **USB port** To a computer, for the monitoring and shutdown software.
5. **Circuit protector** The input breaker: press it to reset after an overload.
6. **Input: C14 inlet** IEC C14 inlet for the supply cord.
7. **8 × NEMA 5-15R outlets** The protected outputs, 120 V.
8. **Battery connector** DC input of the internal battery.

### Rear · 1.5–2.2 kVA

1. **Intelligent slot** For an SNMP network card or a dry-contact card; the -NC models ship with the SNMP card fitted.
2. **Two cooling fans** Two fans on the 1.5, 2, 2.2 and 3 kVA; the air leaves at the rear.
3. **EPO** Emergency power off contact.
4. **USB port** To a computer, for the monitoring and shutdown software.
5. **Circuit protector** The input breaker: press it to reset after an overload.
6. **Input: C20 inlet + 5 ft cord** IEC C20 inlet; the 5 ft supply cord plugs in with its C19 connector.
7. **6 × NEMA 5-20R outlets** The protected outputs, 120 V, 20 A receptacles.
8. **Battery connector** DC input of the internal battery.

### Rear · 3 kVA

1. **Intelligent slot** For an SNMP network card or a dry-contact card; the -NC models ship with the SNMP card fitted.
2. **Two cooling fans** Two fans on the 1.5, 2, 2.2 and 3 kVA; the air leaves at the rear.
3. **EPO** Emergency power off contact.
4. **USB port** To a computer, for the monitoring and shutdown software.
5. **Circuit protector** The input breaker: press it to reset after an overload.
6. **Input: NEMA L5-30P plug** Locking 30 A plug on a 5 ft cord.
7. **1 × NEMA L5-30R outlet** A locking 30 A output for the larger load.
8. **4 × NEMA 5-20R outlets** The protected outputs, 120 V, 20 A receptacles.
9. **Battery connector** DC input of the internal battery.

Datasheet

## LUM2000RT-2U-LI datasheet.

The LUM2000RT-2U-LI in the AEC 2026 catalog, figure by figure. [Compare it with every LUMINA model](https://www.aecups.com/us/products/lumina/#datasheet).

**LUM2000RT-2U-LI datasheet**

| Parameter | LUM2000RT-2U-LI |
| --- | --- |
| Power |  |
| Rated power (kVA) | 2 |
| Active power (kW) | 1.8 |
| Output power factor | 0.9 |
| Electrical |  |
| Input / output | 120 V single-phase |
| Topology | Online Double Conversion |
| Efficiency, up to | 92.5% |
| Battery DC bus | 48 V DC |
| Battery and runtime |  |
| Battery type | Lithium LiFePO4 |
| Battery configuration | Internal |
| Runtime at 50 % load | 27 min |
| Runtime at 100 % load | 11 min |
| Mechanical |  |
| Form factor | Rack 2U |
| Dimensions W × D × H | 17.2 × 22.4 × 3.4 in (438 × 570 × 87 mm) |
| Net weight | 30 lb (13.6 kg) |
| Footprint | 2.7 ft² (0.25 m²) |
| Shipping |  |
| Cartons | 1 |
| Shipping weight | 44.5 lb |
| Common to every LUMINA |  |
| Battery, LUM2000RT-2U-LI | internal LiFePO4 lithium, 10.2 Ah · 489.6 Wh — 11 min at full load, against 4.2 min for the VRLA FERRUS RT of the same kVA, each at its own full load, 12–15 year life (3,000 cycles) |
| Display | rotating color LCD |
| Comms | RS-232, EPO and USB, standard |
| Form factor | 2U rack; telescopic rail kit available |
| Network card | SNMP-L (SNMP) |
| Warranty | 5 years incl. lithium batteries |
| Certification | ETL Listed to [UL 1778](https://www.shopulstandards.com/ProductDetail.aspx?productId=UL1778) and CSA C22.2 No. 107.3 |
| Quality system | ISO 9001:2015, the group's quality system (SGS) |

From the AEC 2026 catalog. Figures can change: the order confirmation rules.

Quick answers

## LUM2000RT-2U-LI: what people ask

#### How long does the LUM2000RT-2U-LI run on battery?

11 min at 100 % load (1.8 kW), 27 min at 50 % load (900 W), 2 h 5 min at 10 % load (180 W), from the catalog runtime table at the start of battery life. Runtime falls faster than the load rises, so the LUM2000RT-2U-LI chart above gives the minutes at any load in between.

#### What is the output current of the LUM2000RT-2U-LI?

16.7 A at 120 V at full load: 2.0 kVA ÷ 120 V. Size the input breaker and the cables of the LUM2000RT-2U-LI from its installation manual and the local electrical code, not from this figure alone.

#### How much heat does the LUM2000RT-2U-LI give off?

About 148 W, 510 BTU/h, at full load, where it is 92.4% efficient. Plan the room's cooling for a little more than that: the LUM2000RT-2U-LI is less efficient at part load and while its battery recharges.

#### How many rack units does the LUM2000RT-2U-LI take?

2U of a 19-inch rack: 3.4 in high, 22.4 in deep. Check the rack's usable depth, rails and rear clearance for the cables.

The method, for any UPS: [runtime explained](https://www.aecups.com/us/blog/ups-runtime-explained/) · [amps from kVA](https://www.aecups.com/us/blog/ups-amps-from-kva/) · [heat output in BTU/h](https://www.aecups.com/us/blog/ups-heat-output-btu/)

LUMINA

## Other LUMINA models

[The LUMINA series, with pictures](https://www.aecups.com/us/products/lumina/#models)

By power, the LUM2000RT-2U-LI is number 3 of 5 in the LUMINA series, which runs from 1 to 3 kVA. One size down is the [LUM1500RT-2U-LI](https://www.aecups.com/us/products/lumina/lum1500rt-2u-li/) (0.5 kVA less and 2 lb heavier). One size up is the [LUM2200RT-2U-LI](https://www.aecups.com/us/products/lumina/lum2200rt-2u-li/) (0.2 kVA more and 12 lb heavier).

#### Every LUMINA model side by side (5)

**LUMINA models side by side**

| Model | Power | Power against this model | Net weight | Weight against this model | Runtime at 50 % load |
| --- | --- | --- | --- | --- | --- |
| [LUM1000RT-2U-LI](https://www.aecups.com/us/products/lumina/lum1000rt-2u-li/) | 1 kVA | 1 kVA less | 20 lb | 10 lb lighter | 27 min at 50 % load |
| [LUM1500RT-2U-LI](https://www.aecups.com/us/products/lumina/lum1500rt-2u-li/) | 1.5 kVA | 0.5 kVA less | 32 lb | 2 lb heavier | 27 min at 50 % load, AEC estimate |
| **LUM2000RT-2U-LI** | 2 kVA | this page | 30 lb | this page | 27 min at 50 % load |
| [LUM2200RT-2U-LI](https://www.aecups.com/us/products/lumina/lum2200rt-2u-li/) | 2.2 kVA | 0.2 kVA more | 42 lb | 12 lb heavier | 46 min at 50 % load |
| [LUM3000RT-2U-LI](https://www.aecups.com/us/products/lumina/lum3000rt-2u-li/) | 3 kVA | 1 kVA more | 38 lb | 8 lb heavier | 27 min at 50 % load |

Install and run it: [LUMINA operating guide](https://www.aecups.com/us/support/guides/lumina/)

## The LUM2000RT-2U-LI for your project

Send the load, the voltage and the minutes you need from the LUM2000RT-2U-LI. We reply with the configuration, the batteries and the lead time.

[Send your project](https://www.aecups.com/us/contacts/?interest=UPS%20single-phase&msg=About%20the%20LUM2000RT-2U-LI%20(LUMINA)%3A%20%0AQuantity%3A%20#form) [+1 786 553 2100](tel:+17865532100)
