title: "RADIANT-IB Modular UPS 20–100 kVA 208V | AEC"
url: https://www.aecups.com/us/products/radiant-ib/
description: "RADIANT-IB is AEC's modular online UPS with N+X redundancy for three-phase 208 V loads from 20 to 100 kVA."
language: en-US
---

Three-phase 208 V UPS

# RADIANT-IB modular UPS, 20–100 kVA, 208 V

VRLA Modular N+X Modular

RADIANT-IB is AEC's modular online UPS with N+X redundancy for three-phase 208 V loads from 20 to 100 kVA, with internal hot-swappable VRLA battery trays. Power modules of 20 kVA and up to 240 blocks of 12 V 9 Ah share one frame, the batteries in hot-swappable trays.

**20–100** kVA

**94%** Efficiency, up to

**1.0** Power factor

**3 yr** Warranty

Datasheet Manuals and catalogs [Contact us](https://www.aecups.com/us/contacts/?interest=UPS%20three-phase&msg=About%20the%20RADIANT-IB%3A%20%0AQuantity%3A%20#form)

[**Try 3D** X-ray view](https://www.aecups.com/assets/models3d/radib/v59/)

Drag to turn

In 3D

## Look around the RADIANT-IB

Drag it round, swipe on a phone or use the arrow keys. X-ray makes the enclosure see-through, so you can see what sits behind the panels.

[Open full 3D · X-ray](https://www.aecups.com/assets/models3d/radib/v59/)

Rendered from AEC's 3D model of the RADIANT-IB 20–100 kVA. The full 3D view zooms in, opens the unit and names every part.

Hands on

## Open the RADIANT-IB yourself.

Click the unit: the door opens, then a module comes out. Drag to move it by hand. The 3D shows every part.

[Every part in 3D](https://www.aecups.com/assets/models3d/radib/v59/)

Efficiency

## How efficient is the RADIANT-IB at your load?

The RADIANT-IB in normal double-conversion mode, from the 2026 catalog's efficiency curve. Drag along it to see the heat lost and its yearly cost.

**—** %

**Load**: —

**Lost as heat**: —

**Heat to remove**: —

**Energy lost in a year, 24/7**: —

**Its cost in a year at per kWh**: —

The display

## The RADIANT-IB display.

The real touchscreen, from the user manual: pick a main page, or touch the screen as on the UPS.

RADIANT · CIRRO · the real screen

### Home

The home page after the welcome window: status bar, output voltage gauges, battery bars, energy flow and warning information, with the main menu on the left.

**The ten main pages**

What is what

## Inside the RADIANT-IB, part by part.

Each number is named in the list under its picture: the front with its door open and the rear, side by side.

### Front, door open

1. **Power modules, 20 kVA: up to 5** Slot No. 1 at the bottom: fit modules from the bottom up.
2. **Bypass & monitoring module** Its communication panel and fans.
3. **Battery trays: 6 rows of 4, 24 trays** Each tray plugs in with its own 50 A connector.
4. **A tray drawn out** Ten 12 V blocks.

### Rear, doors open

1. **Module backplane** The power modules seen from the rear, with their busbars.
2. **Battery breaker** Connects the internal battery trays to the DC bus of the power modules.
3. **Output, maintenance and input breakers** Left to right: output to the load; maintenance bypass, normally OFF, around the whole UPS for service; main input to the rectifiers.
4. **Terminal cover** Behind it the power terminals.
5. **Rear doors** Two: the breakers and the power terminals are reached from the rear.
6. **Touchscreen** 7-inch, on the front door.

**RADIANT-IB in 3D, door open** The door opens on what is inside. · 0:06

Overview

## Key facts

**Power range**: 20–100 kVA

**Technology**: 3-level IGBT; unity power factor (kVA = kW); 40 A settable charger

**Input / Output**: 208/120 V three-phase

**Battery**: internal hot-swappable VRLA, up to 240 × 12V 9Ah (240 pcs)

**Display**: 7-inch color touchscreen

**Comms**: RS-232, EPO and USB, standard

**Power factor**: 1.0 (kVA = kW)

**Network card**: SNMP-M (SNMP)

**Warranty**: 3 years on UPS · 2 years on VRLA batteries

**Quality system**: ISO 9001:2015, the group's quality system (SGS)

Models

## Which RADIANT-IB fits your load?

5 models for the US market, from the 2026 catalog. Pick the power, open a model for its full datasheet.

[**RADIB100-1X20** 20 kVA · 20 kW 1 × 20 kVA power module, 240 × 12 V 9 Ah VRLA blocks inside **1,998 lb** net weight **Internal Tray System** batteries Details and datasheet](https://www.aecups.com/us/products/radiant-ib/radib100-1x20/) [**RADIB100-2X20** 40 kVA · 40 kW 2 × 20 kVA power modules, 240 × 12 V 9 Ah VRLA blocks inside **2,042 lb** net weight **Internal Tray System** batteries Details and datasheet](https://www.aecups.com/us/products/radiant-ib/radib100-2x20/) [**RADIB100-3X20** 60 kVA · 60 kW 3 × 20 kVA power modules, 240 × 12 V 9 Ah VRLA blocks inside **2,086 lb** net weight **Internal Tray System** batteries Details and datasheet](https://www.aecups.com/us/products/radiant-ib/radib100-3x20/) [**RADIB100-4X20** 80 kVA · 80 kW 4 × 20 kVA power modules, 240 × 12 V 9 Ah VRLA blocks inside **2,130 lb** net weight **Internal Tray System** batteries Details and datasheet](https://www.aecups.com/us/products/radiant-ib/radib100-4x20/) [**RADIB100-5X20** 100 kVA · 100 kW 5 × 20 kVA power modules, 240 × 12 V 9 Ah VRLA blocks inside **2,174 lb** net weight **Internal Tray System** batteries Details and datasheet](https://www.aecups.com/us/products/radiant-ib/radib100-5x20/)

### Options and parts for RADIANT-IB

- **RADIB-BATTR-10x9A** Battery Tray incl. 10 × 12 V 9 Ah
- **RADIB-BATTR-EMPTY** Battery Tray empty
- **RADIB-FRAME** RADIANT-IB 100 kVA Frame — no power module, no battery trays, 5 module slots 23.6" W × 39.4" D × 78.7" H (600 × 1,000 × 2,000 mm) · 430 lb (195 kg)
- **RADIB-PWR-20** Power Module 20 kVA — RADIANT-IB 17.3" W × 26.7" D × 3.4" H (440 × 678 × 85 mm) · 44 lb (20 kg)

Datasheet

## RADIANT-IB datasheet.

Every model side by side. Filter by power, keep only what differs, print it or take it as CSV.

**RADIANT-IB datasheet, 5 models**

| Model | [RADIB100-1X20](https://www.aecups.com/us/products/radiant-ib/radib100-1x20/) | [RADIB100-2X20](https://www.aecups.com/us/products/radiant-ib/radib100-2x20/) | [RADIB100-3X20](https://www.aecups.com/us/products/radiant-ib/radib100-3x20/) | [RADIB100-4X20](https://www.aecups.com/us/products/radiant-ib/radib100-4x20/) | [RADIB100-5X20](https://www.aecups.com/us/products/radiant-ib/radib100-5x20/) |
| --- | --- | --- | --- | --- | --- |
| Power |  |  |  |  |  |
| Rated power (kVA) | 20 | 40 | 60 | 80 | 100 |
| Active power (kW) | 20 | 40 | 60 | 80 | 100 |
| Output power factor | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 |
| Electrical |  |  |  |  |  |
| Input / output | 208 V three-phase, 4-wire (3P+N) | 208 V three-phase, 4-wire (3P+N) | 208 V three-phase, 4-wire (3P+N) | 208 V three-phase, 4-wire (3P+N) | 208 V three-phase, 4-wire (3P+N) |
| Topology | Online double conversion, modular N+X | Online double conversion, modular N+X | Online double conversion, modular N+X | Online double conversion, modular N+X | Online double conversion, modular N+X |
| Efficiency, up to | 94% | 94% | 94% | 94% | 94% |
| Battery DC bus | 240 V DC | 240 V DC | 240 V DC | 240 V DC | 240 V DC |
| Battery and runtime |  |  |  |  |  |
| Battery type | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) |
| Battery configuration | Internal Tray System | Internal Tray System | Internal Tray System | Internal Tray System | Internal Tray System |
| Runtime at 50 % load | 85 min | 32 min | 21.5 min | 14 min | 12 min |
| Runtime at 100 % load | 32 min | 14 min | 8 min | 6 min | 3 min |
| Mechanical |  |  |  |  |  |
| Form factor | Modular | Modular | Modular | Modular | Modular |
| Dimensions W × D × H | 23.6 × 39.3 × 78.7 in (599 × 998 × 1,999 mm) | 23.6 × 39.3 × 78.7 in (599 × 998 × 1,999 mm) | 23.6 × 39.3 × 78.7 in (599 × 998 × 1,999 mm) | 23.6 × 39.3 × 78.7 in (599 × 998 × 1,999 mm) | 23.6 × 39.3 × 78.7 in (599 × 998 × 1,999 mm) |
| Net weight | 1,998 lb (906.3 kg) | 2,042 lb (926.2 kg) | 2,086 lb (946.2 kg) | 2,130 lb (966.2 kg) | 2,174 lb (986.1 kg) |
| Footprint | 6.4 ft² (0.60 m²) | 6.4 ft² (0.60 m²) | 6.4 ft² (0.60 m²) | 6.4 ft² (0.60 m²) | 6.4 ft² (0.60 m²) |
| Shipping |  |  |  |  |  |
| Cartons | 26 | 27 | 28 | 29 | 30 |

From the AEC 2026 catalog. Efficiency is the catalog's “up to” figure; runtimes are AEC's runtime tables with new batteries; weights are the unit alone, without batteries outside it. Figures can change: the order confirmation rules.

Install and run it: [RADIANT-IB installation and operation manual](https://www.aecups.com/us/support/guides/radiant-ib-manual/) [RADIANT and CIRRO touch screen guide](https://www.aecups.com/us/support/guides/radiant-cirro/)

Plan it: [Size it for your load](https://www.aecups.com/us/tools/ups-sizing/) [Room fit](https://www.aecups.com/us/tools/room-fit/) [RADIANT-IB compared with other makers](https://www.aecups.com/us/comparisons/modular-ups-208v/) [Warranty terms](https://www.aecups.com/us/warranty/)

Replacing another brand's UPS? [Type its model number: the AEC match](https://www.aecups.com/us/cross-reference/)

RADIANT-IB: quick answers

## Questions people ask

#### What sizes does RADIANT-IB come in?

20 to 100 kVA, in 5 models of the 2026 catalog for the US, from the RADIB100-1X20 (20 kVA) to the RADIB100-5X20 (100 kVA). The datasheet on this page gives every one.

#### What supply does RADIANT-IB need?

208/120 V three-phase, for every model of the series. Its power factor is 1.0, so each model gives its kVA rating in kW.

#### What batteries does RADIANT-IB use?

Internal hot-swappable VRLA, up to 240 × 12 V 9 Ah blocks. The battery bus is 240 V DC on every model.

#### What warranty does RADIANT-IB have?

3 years on UPS; 2 years on VRLA batteries, from start-up. Register the UPS with AEC after start-up.

#### How is RADIANT-IB monitored over the network?

With the AEC SNMP-M network card, which reports the UPS status and alarms over SNMP to your monitoring software.

[What is the output current of each RADIANT-IB model?](https://www.aecups.com/us/faq/radiant-ib/#q1) [How much heat does each RADIANT-IB model give off?](https://www.aecups.com/us/faq/radiant-ib/#q2) [Which RADIANT-IB models fit through a standard door?](https://www.aecups.com/us/faq/radiant-ib/#q3) [All 8 questions](https://www.aecups.com/us/faq/radiant-ib/)

RADIANT-IB in the field: [LUMINA and RADIANT-IB UPS at a Dominican resort](https://www.aecups.com/us/projects/lumina-radiant-dominican-resort/) [All projects](https://www.aecups.com/us/projects/)

Also in 208V three-phase UPS: [ETHERNO](https://www.aecups.com/us/products/etherno/) [AUREON](https://www.aecups.com/us/products/aureon/) [RADIANT](https://www.aecups.com/us/products/radiant/) [Compare the range](https://www.aecups.com/us/products/three-phase-ups-208v/)

Read next: [UPS generator sizing: input, recharge and other loads](https://www.aecups.com/us/blog/ups-generator-sizing/) [Modular vs monolithic UPS, 208 V: space, N+1, service](https://www.aecups.com/us/blog/modular-vs-monolithic-ups/) [How long will a UPS run? Battery runtime explained](https://www.aecups.com/us/blog/ups-runtime-explained/)

## The RADIANT-IB for your project

Send the load, the voltage and the minutes. We reply with the RADIANT-IB model that fits, its batteries and the lead time.

[Send your project](https://www.aecups.com/us/contacts/?interest=UPS%20three-phase&msg=About%20the%20RADIANT-IB%3A%20%0AQuantity%3A%20#form) [+1 786 553 2100](tel:+17865532100)