# RADIB100-1X20 RADIANT-IB 20 kVA, 208V three-phase UPS

VRLA 20 kVA Online double conversion

The AEC RADIANT-IB RADIB100-1X20 is a 20 kVA / 20 kW online double-conversion UPS for 208 V three-phase loads, built on one 20 kVA power module, with VRLA batteries on internal trays. Kept at 80 % of its rating, it carries loads up to 16 kW.

One of the frame's five module slots is fitted, so no module is spare at this size; four more modules take the frame to 100 kVA. As configured it weighs 1,998 lb (906.3 kg) net.

**20 kVA / 20 kW** Rating

**23.6 × 39.3 × 78.7 in** W × D × H

**1,998 lb** Weight

**VRLA, internal** Battery

Technical data [Catalog (PDF)](https://www.aecups.com/docs/AEC_RADIANT_IB_2026.pdf) [Contact us](https://www.aecups.com/us/contacts/?interest=UPS%20three-phase&msg=About%20the%20RADIB100-1X20%20(RADIANT-IB)%3A%20%0AQuantity%3A%20#form)

[**Try 3D** X-ray view](https://www.aecups.com/assets/models3d/radib/v59/#radib100-1)

Series picture.

Drag to turn

In 3D

## Look around the RADIB100-1X20

[Open full 3D · X-ray](https://www.aecups.com/assets/models3d/radib/v59/#radib100-1)

The turntable shows the 100 kVA · 5 modules configuration; the full 3D view opens on this model.

The same on every RADIANT-IB: [The RADIANT-IB display](https://www.aecups.com/us/products/radiant-ib/#display)

Load by load

## The RADIB100-1X20 at 25, 50, 75 and 100 % load.

Its 20 kW rating in four steps, worked out from its own catalog figures.

**At 25, 50, 75 and 100 % load**

| Load | Output current per phase, at 208 V | Efficiency | Heat to remove | Heat to remove (BTU/h) |
| --- | --- | --- | --- | --- |
| 25 % of the RADIB100-1X20, 5.0 kW | 13.9 A per phase | 92.7 % efficient | 394 W of heat | 1,340 BTU/h to cool |
| 50 % of the RADIB100-1X20, 10 kW | 27.8 A per phase | 93.9 % efficient | 650 W of heat | 2,220 BTU/h to cool |
| 75 % of the RADIB100-1X20, 15 kW | 41.6 A per phase | 94.0 % efficient | 957 W of heat | 3,270 BTU/h to cool |
| 100 % of the RADIB100-1X20, 20 kW | 55.5 A per phase | 93.8 % efficient | 1.3 kW of heat | 4,510 BTU/h to cool |

Current = kVA × load ÷ (√3 × volts).

Heat = load × (100 ÷ efficiency − 1); 1 kW is 3,412 BTU/h.

From the 2026 catalog

## What is the RADIB100-1X20?

The code RADIB100-1X20 orders these catalog items, shipped in 26 cartons:

- 1 × RADIB-FRAME: 100 kVA frame, without power modules, 23.6 × 39.4 × 78.7 in (600 × 1,000 × 2,000 mm)
- 1 × RADIB-PWR-20: 20 kVA hot-swappable power module, 44 lb (20 kg)
- 24 × RADIB-BATTR-10x9A: battery tray of 10 × 12 V 9 Ah VRLA blocks, 63.5 lb (28.8 kg) each
- Architecture: 1 × 20 kVA hot-swappable power module in a 100 kVA / 100 kW frame (scalable to 5 modules / 100 kVA); parallel up to 3 cabinets.

The lines every RADIANT-IB shares, from technology to warranty, are in the [RADIANT-IB key facts](https://www.aecups.com/us/products/radiant-ib/#overview) and in the datasheet below.

1 × 20 kVA power modules fitted in a 5-slot frame: 4 free slots to grow or add redundancy.

Size and floor

## How big it is

23.6" W × 39.3" D × 78.7" H (599 × 998 × 1,999 mm); 1,998 lb (906.3 kg) net.

**6.4 ft²** footprint (0.60 m²)

**310 lb/ft²** floor load of the cabinet alone

**Modular** form factor

Floor load = net weight ÷ footprint, without batteries outside the cabinet.

Datasheet

## RADIB100-1X20 datasheet.

The RADIB100-1X20 in the AEC 2026 catalog, figure by figure. [Compare it with every RADIANT-IB model](https://www.aecups.com/us/products/radiant-ib/#datasheet).

**RADIB100-1X20 datasheet**

| Parameter | RADIB100-1X20 |
| --- | --- |
| Power |  |
| Rated power (kVA) | 20 |
| Active power (kW) | 20 |
| Output power factor | 1.0 |
| Electrical |  |
| Input / output | 208 V three-phase, 4-wire (3P+N) |
| Topology | Online double conversion, modular N+X |
| Efficiency, up to | 94% |
| Battery DC bus | 240 V DC |
| Battery and runtime |  |
| Battery type | VRLA (sealed lead-acid) |
| Battery configuration | Internal Tray System |
| Runtime at 50 % load | 85 min |
| Runtime at 100 % load | 32 min |
| Mechanical |  |
| Form factor | Modular |
| Dimensions W × D × H | 23.6 × 39.3 × 78.7 in (599 × 998 × 1,999 mm) |
| Net weight | 1,998 lb (906.3 kg) |
| Footprint | 6.4 ft² (0.60 m²) |
| Shipping |  |
| Cartons | 26 |
| Common to every RADIANT-IB |  |
| Technology | 3-level IGBT; unity power factor (kVA = kW); 40 A settable charger |
| Battery, RADIB100-1X20 | internal hot-swappable VRLA, up to 240 × 12V 9Ah (240 pcs) |
| Display | 7-inch color touchscreen |
| Comms | RS-232, EPO and USB, standard |
| Network card | SNMP-M (SNMP) |
| Warranty | 3 years on UPS · 2 years on VRLA batteries |
| Quality system | ISO 9001:2015, the group's quality system (SGS) |

From the AEC 2026 catalog. Figures can change: the order confirmation rules.

Quick answers

## RADIB100-1X20: what people ask

#### What is the output current of the RADIB100-1X20?

55.5 A per phase at full load: 20 kVA ÷ (√3 × 208 V). Size the input breaker and the cables of the RADIB100-1X20 from its installation manual and the local electrical code, not from this figure alone.

#### How much heat does the RADIB100-1X20 give off?

About 1.3 kW, 4,510 BTU/h, at full load, where it is 93.8% efficient. Plan the room's cooling for a little more than that: the RADIB100-1X20 is less efficient at part load and while its battery recharges.

#### Will the RADIB100-1X20 fit through a standard door?

Yes: 23.6 in (599 mm) across its narrow side and 78.7 in (1,999 mm) high, it passes a standard 36 × 80-inch door upright, with little to spare in height. On the way in, check corridors, elevators and the floor load of the RADIB100-1X20 (size section above).

The method, for any UPS: [runtime explained](https://www.aecups.com/us/blog/ups-runtime-explained/) · [amps from kVA](https://www.aecups.com/us/blog/ups-amps-from-kva/) · [heat output in BTU/h](https://www.aecups.com/us/blog/ups-heat-output-btu/)

RADIANT-IB

## Other RADIANT-IB models

[The RADIANT-IB series, with pictures](https://www.aecups.com/us/products/radiant-ib/#models)

By power, the RADIB100-1X20 is the smallest in the RADIANT-IB series, which runs from 20 to 100 kVA. One size up is the [RADIB100-2X20](https://www.aecups.com/us/products/radiant-ib/radib100-2x20/) (20 kVA more and 44 lb heavier).

#### Every RADIANT-IB model side by side (5)

**RADIANT-IB models side by side**

| Model | Power | Power against this model | Net weight | Weight against this model | Runtime at 50 % load |
| --- | --- | --- | --- | --- | --- |
| **RADIB100-1X20** | 20 kVA | this page | 1,998 lb | this page | 85 min at 50 % load |
| [RADIB100-2X20](https://www.aecups.com/us/products/radiant-ib/radib100-2x20/) | 40 kVA | 20 kVA more | 2,042 lb | 44 lb heavier | 32 min at 50 % load |
| [RADIB100-3X20](https://www.aecups.com/us/products/radiant-ib/radib100-3x20/) | 60 kVA | 40 kVA more | 2,086 lb | 88 lb heavier | 21.5 min at 50 % load |
| [RADIB100-4X20](https://www.aecups.com/us/products/radiant-ib/radib100-4x20/) | 80 kVA | 60 kVA more | 2,130 lb | 132 lb heavier | 14 min at 50 % load |
| [RADIB100-5X20](https://www.aecups.com/us/products/radiant-ib/radib100-5x20/) | 100 kVA | 80 kVA more | 2,174 lb | 176 lb heavier | 12 min at 50 % load |

Install and run it: [RADIANT-IB installation and operation manual](https://www.aecups.com/us/support/guides/radiant-ib-manual/) [RADIANT and CIRRO touch screen guide](https://www.aecups.com/us/support/guides/radiant-cirro/)

## The RADIB100-1X20 for your project

Send the load, the voltage and the minutes you need from the RADIB100-1X20. We reply with the configuration, the batteries and the lead time.

[Send your project](https://www.aecups.com/us/contacts/?interest=UPS%20three-phase&msg=About%20the%20RADIB100-1X20%20(RADIANT-IB)%3A%20%0AQuantity%3A%20#form) [+1 786 553 2100](tel:+17865532100)