title: "15–90 kVA 208 V three-phase UPS: AEC RADIANT RAD90"
url: https://www.aecups.com/us/products/radiant/rad90/
description: "AEC RADIANT RAD90: 15–90 kVA online UPS for 208 V three-phase, with 1, 2, 3, 4, 5 or 6 × 15 kVA modules."
language: en-US
---

RADIANT · 208 V three-phase UPS

# RAD90 RADIANT 90 kVA frame, 15–90 kVA fitted

VRLA 15–90 kVA 6 ordering codes

The AEC RADIANT RAD90 is a 90 kVA modular UPS frame for 208 V three-phase loads with six slots for 15 kVA hot-swappable power modules. The 2026 catalog lists it with 1, 2, 3, 4, 5 or 6 modules fitted, 15–90 kVA in all; each code is a row below.

**15–90 kVA** Rating

**17.4 × 33.1 × 59.4 in** W × D × H

**238–391 lb** Weight, by code

**VRLA, external** Battery

Every code [Catalog (PDF)](https://www.aecups.com/docs/AEC_RADIANT_2026.pdf) [Contact us](https://www.aecups.com/us/contacts/?interest=Three-phase%20UPS&msg=About%20the%20RAD90%20(RADIANT)%3A%20%0AQuantity%3A%20#form)

[**Try 3D** X-ray view](https://www.aecups.com/assets/models3d/rad90/v58/#rad90-6)

Series picture.

6 ordering codes

## Which RAD90 do you need?

One 90 kVA frame, a row per number of modules fitted. Only what changes from one code to the next is here; what they share is under the table.

**RAD90: the ordering codes and what changes from one to the next**

| Ordering code | Power | Free slots | With one module spare (N+1) | Net weight | Floor load | Current per phase at 208 V |
| --- | --- | --- | --- | --- | --- | --- |
| **RAD90-1X15** 1 × 15 kVA power module [3D](https://www.aecups.com/assets/models3d/rad90/v58/#rad90-1) [Ask](https://www.aecups.com/us/contacts/?interest=Three-phase%20UPS&msg=About%20the%20RAD90-1X15%20(RADIANT)%3A%20%0AQuantity%3A%20#form) | 15 kVA / 15 kW | 5 of 6 | no spare with one module | 238 lb (108 kg) | 60 lb/ft² | 41.6 A |
| **RAD90-2X15** 2 × 15 kVA power modules [3D](https://www.aecups.com/assets/models3d/rad90/v58/#rad90-2) [Ask](https://www.aecups.com/us/contacts/?interest=Three-phase%20UPS&msg=About%20the%20RAD90-2X15%20(RADIANT)%3A%20%0AQuantity%3A%20#form) | 30 kVA / 30 kW | 4 of 6 | 15 kVA | 268.5 lb (121.8 kg) | 67 lb/ft² | 83.3 A |
| **RAD90-3X15** 3 × 15 kVA power modules [3D](https://www.aecups.com/assets/models3d/rad90/v58/#rad90-3) [Ask](https://www.aecups.com/us/contacts/?interest=Three-phase%20UPS&msg=About%20the%20RAD90-3X15%20(RADIANT)%3A%20%0AQuantity%3A%20#form) | 45 kVA / 45 kW | 3 of 6 | 30 kVA | 299 lb (135.7 kg) | 75 lb/ft² | 125 A |
| **RAD90-4X15** 4 × 15 kVA power modules [3D](https://www.aecups.com/assets/models3d/rad90/v58/#rad90-4) [Ask](https://www.aecups.com/us/contacts/?interest=Three-phase%20UPS&msg=About%20the%20RAD90-4X15%20(RADIANT)%3A%20%0AQuantity%3A%20#form) | 60 kVA / 60 kW | 2 of 6 | 45 kVA | 329.5 lb (149.5 kg) | 82 lb/ft² | 167 A |
| **RAD90-5X15** 5 × 15 kVA power modules [3D](https://www.aecups.com/assets/models3d/rad90/v58/#rad90-5) [Ask](https://www.aecups.com/us/contacts/?interest=Three-phase%20UPS&msg=About%20the%20RAD90-5X15%20(RADIANT)%3A%20%0AQuantity%3A%20#form) | 75 kVA / 75 kW | 1 of 6 | 60 kVA | 360 lb (163.4 kg) | 90 lb/ft² | 208 A |
| **RAD90-6X15** 6 × 15 kVA power modules [3D](https://www.aecups.com/assets/models3d/rad90/v58/#rad90-6) [Ask](https://www.aecups.com/us/contacts/?interest=Three-phase%20UPS&msg=About%20the%20RAD90-6X15%20(RADIANT)%3A%20%0AQuantity%3A%20#form) | 90 kVA / 90 kW | none of 6 | 75 kVA | 390.5 lb (177.2 kg) | 98 lb/ft² | 250 A |

This model

## What sets the RAD90 apart

The RADIANT is a 90 kVA frame for 208 V three-phase, 17.4 in wide and 59.4 in high, with six slots for 15 kVA power modules and four breakers. The catalog lists it with one to six modules, 15 to 90 kVA, in steps of 15 kVA, the finest steps of any AEC modular frame.

Each module adds 30.5 lb and 41.6 A per phase at full load; with all six it weighs 390.5 lb (177.2 kg). Its batteries stand outside in a bank sized for the minutes needed. Bought at 60 kVA with four modules, it has two slots left for growth, or for N+1 at 60 kVA with a fifth.

Drag to turn

In 3D

## Look around the RAD90-6X15

[Open full 3D · X-ray](https://www.aecups.com/assets/models3d/rad90/v58/#rad90-6)

The same on every RADIANT: [The RADIANT display](https://www.aecups.com/us/products/radiant/#display)

Efficiency

## How efficient is the RAD90-6X15 at your load?

The RAD90-6X15 in normal double-conversion mode, from the 2026 catalog's efficiency curve. Drag along it to see the heat lost and its yearly cost.

**—** %

**Load**: —

**Lost as heat**: —

**Heat to remove**: —

**Energy lost in a year, 24/7**: —

**Its cost in a year at per kWh**: —

[Every RADIANT size on one curve](https://www.aecups.com/us/products/radiant/#efficiency)

From the 2026 catalog

## What every RAD90 code shares

- Each 15 kVA power module, RAD-PWR-15: 30.5 lb (13.9 kg), hot-swappable
- Technology: 3-level IGBT; unity power factor (kVA = kW); 40 A settable charger.
- Input / Output: 208/120 V three-phase.
- Battery: external VRLA (battery bank sized separately).
- Efficiency: up to 94%.
- Display: 7-inch color touchscreen.
- Comms: RS-232, EPO and USB, standard.
- Warranty: 3 years on UPS · 2 years on VRLA batteries.
- Cabinet: 17.4" W × 33.1" D × 59.4" H (442 × 840 × 1,510 mm), the same for every code above

The lines every RADIANT shares, from technology to warranty, are in the [RADIANT key facts](https://www.aecups.com/us/products/radiant/#overview).

Size and floor

## How big it is

17.4" W × 33.1" D × 59.4" H (442 × 840 × 1,510 mm); from 238 lb (108 kg) to 390.5 lb (177.2 kg) net, code by code.

**4.0 ft²** footprint (0.37 m²)

**98 lb/ft²** floor load of the heaviest code

**Modular Rack 19"** form factor

Floor load = net weight ÷ footprint, without batteries outside the cabinet.

Datasheet

## RAD90 datasheet, code by code.

Every figure of the 6 codes in the AEC 2026 catalog. [Compare them with every RADIANT model](https://www.aecups.com/us/products/radiant/#datasheet).

**RADIANT datasheet, 6 models**

| Model | [RAD90-1X15](https://www.aecups.com/us/products/radiant/rad90/#rad90-1x15) | [RAD90-2X15](https://www.aecups.com/us/products/radiant/rad90/#rad90-2x15) | [RAD90-3X15](https://www.aecups.com/us/products/radiant/rad90/#rad90-3x15) | [RAD90-4X15](https://www.aecups.com/us/products/radiant/rad90/#rad90-4x15) | [RAD90-5X15](https://www.aecups.com/us/products/radiant/rad90/#rad90-5x15) | [RAD90-6X15](https://www.aecups.com/us/products/radiant/rad90/#rad90-6x15) |
| --- | --- | --- | --- | --- | --- | --- |
| Power |  |  |  |  |  |  |
| Rated power (kVA) | 15 | 30 | 45 | 60 | 75 | 90 |
| Active power (kW) | 15 | 30 | 45 | 60 | 75 | 90 |
| Output power factor | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 |
| Electrical |  |  |  |  |  |  |
| Input / output | 208 V three-phase, 4-wire (3P+N) | 208 V three-phase, 4-wire (3P+N) | 208 V three-phase, 4-wire (3P+N) | 208 V three-phase, 4-wire (3P+N) | 208 V three-phase, 4-wire (3P+N) | 208 V three-phase, 4-wire (3P+N) |
| Topology | Online double conversion, modular N+X | Online double conversion, modular N+X | Online double conversion, modular N+X | Online double conversion, modular N+X | Online double conversion, modular N+X | Online double conversion, modular N+X |
| Efficiency, up to | 94% | 94% | 94% | 94% | 94% | 94% |
| Battery DC bus | 240 V DC | 240 V DC | 240 V DC | 240 V DC | 240 V DC | 240 V DC |
| Battery and runtime |  |  |  |  |  |  |
| Battery type | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) |
| Battery configuration | External battery bank | External battery bank | External battery bank | External battery bank | External battery bank | External battery bank |
| Mechanical |  |  |  |  |  |  |
| Form factor | Modular Rack 19" | Modular Rack 19" | Modular Rack 19" | Modular Rack 19" | Modular Rack 19" | Modular Rack 19" |
| Dimensions W × D × H | 17.4 × 33.1 × 59.4 in (442 × 840 × 1,510 mm) | 17.4 × 33.1 × 59.4 in (442 × 840 × 1,510 mm) | 17.4 × 33.1 × 59.4 in (442 × 840 × 1,510 mm) | 17.4 × 33.1 × 59.4 in (442 × 840 × 1,510 mm) | 17.4 × 33.1 × 59.4 in (442 × 840 × 1,510 mm) | 17.4 × 33.1 × 59.4 in (442 × 840 × 1,510 mm) |
| Net weight | 238 lb (108 kg) | 268.5 lb (121.8 kg) | 299 lb (135.7 kg) | 329.5 lb (149.5 kg) | 360 lb (163.4 kg) | 390.5 lb (177.2 kg) |
| Footprint | 4.0 ft² (0.37 m²) | 4.0 ft² (0.37 m²) | 4.0 ft² (0.37 m²) | 4.0 ft² (0.37 m²) | 4.0 ft² (0.37 m²) | 4.0 ft² (0.37 m²) |

From the AEC 2026 catalog. Efficiency is the catalog's “up to” figure; weights are the unit alone, without batteries outside it. Figures may change; the order confirmation governs.

RADIANT

## Other RADIANT models

[The RADIANT series, with pictures](https://www.aecups.com/us/products/radiant/#models)

The RADIANT has this one model page; [its datasheet](https://www.aecups.com/us/products/radiant/#datasheet) sets every code side by side.

Install and run it: [RADIANT installation and operation manual](https://www.aecups.com/us/support/guides/radiant-manual/) [RADIANT and CIRRO touch screen guide](https://www.aecups.com/us/support/guides/radiant-cirro/)

The figures above, explained: [How many amps does a UPS draw?](https://www.aecups.com/us/blog/ups-amps-from-kva/) [Which VRLA batteries and cabinets does AEC supply?](https://www.aecups.com/us/products/batteries/)

## The RAD90 for your project

Send the load, the voltage and the minutes you need from the RAD90. We reply with the code, the batteries and the lead time.

[Send your project](https://www.aecups.com/us/contacts/?interest=Three-phase%20UPS&msg=About%20the%20RAD90%20(RADIANT)%3A%20%0AQuantity%3A%20#form) [+1 786 553 2100](tel:+17865532100)