# 120/240V split-phase UPS, 6 to 20 kVA

A split-phase UPS serves 120/240 V panels: two 120 V legs and a neutral, 240 V between the legs, common in small commercial buildings, clinics and offices. AEC offers two online series for it, with an isolation transformer and a maintenance bypass: FERRUS SP, a tower from 6 to 20 kVA, and FERRUS SP RT, a rack/tower from 6 to 10 kVA.

**2** Series

**6–20** kVA

**VRLA** Battery

**3 yr** Warranty

A split-phase UPS serves 120/240 V single-phase panels: two 120 V legs and a neutral, with 240 V between the legs. It is one of the most common services in the US, in small commercial buildings, clinics, offices and homes, and it feeds both 240 V loads and 120 V circuits.

AEC offers two online double-conversion series for it, both with an integrated isolation transformer and a manual maintenance bypass: FERRUS SP, a tower from 6 to 20 kVA, and FERRUS SP RT, a rack/tower from 6 to 10 kVA.

Series

## The two AEC series for 120/240 V split-phase

### FERRUS SP

VRLA

6–20 kVA · 120/240 V

Online double-conversion UPS for split-phase 120/240 V loads from 6 to 20 kVA, in a tower cabinet, with VRLA batteries.

View series

### FERRUS SP RT

VRLA

6–10 kVA · 120/240 V

Online double-conversion UPS for split-phase 120/240 V loads from 6 to 10 kVA, in a 19-inch rack, with external 3U rack battery cabinets of 16 × 12 V 9 Ah VRLA blocks, the first one included.

View series

Compare

## 120/240V split-phase UPS models compared.

| Series | Power | Supply | Battery | Form | Efficiency | Warranty | Models |
| --- | --- | --- | --- | --- | --- | --- | --- |
| [**FERRUS SP**](https://www.aecups.com/us/products/ferrus-sp/) | 6–20 kVA | 120/240 V, split-phase | VRLA batteries | Tower | 93% | 3 years | 3 |
| [**FERRUS SP RT**](https://www.aecups.com/us/products/ferrus-sp-rt/) | 6–10 kVA | 120/240 V, split-phase | VRLA: each UPS comes with a 3U rack cabinet of 16 × 12 V 9 Ah blocks | Rack | 93% | 3 years | 2 |

Range

## Which one carries your load?

Drag to your load in kVA.

Guides

## Read before you choose.

[All guides](https://www.aecups.com/us/blog/)

### UPS for offices, retail and small business

9 min read

Protect a small office, a store or a clinic in the US: 120 V and 120/240 V UPS, NEMA receptacles, runtime packs, lithium or VRLA, and what to plug in.

### UPS for hospitals and clinics: 120/240 V, 208 V and 480 V

9 min read

Where a UPS fits in a US healthcare building: the 10-second generator gap, IT and nurse-call loads, 120 V to 480 V, and the AEC series for each.

### How to size a UPS: five steps to the power you need

10 min read

Size a UPS in five steps: load in watts, kVA and kW, voltage and phase, runtime, and room to grow. With a calculator.

Questions

## Questions people ask

#### What is a split-phase UPS?

A UPS whose input and output are 120/240 V split phase: two 120 V legs 180 degrees apart and a neutral. Loads connect at 240 V between the legs or at 120 V from a leg to the neutral.

#### 240 V or 208 V: what is the difference?

240 V comes from a split-phase service; 208 V is measured between two legs of a three-phase 208Y/120 V service. Check the equipment's nameplate: some equipment accepts both, some only one. For a three-phase 208 V panel, see the 208V three-phase UPS.

#### Can a split-phase UPS run a motor or a well pump?

Yes, if the UPS is sized for the starting current: motors draw several times their running current when they start, so size for that, not for the running watts: send us the motor's nameplate and our engineers size it.

## Talk to an engineer

Tell us the load, the voltage and the minutes you need. We answer with the model and the batteries that fit.

[Send your project](https://www.aecups.com/us/contacts/#form) [+1 786 553 2100](tel:+17865532100)