title: "UPS technology: double conversion, lithium, modular | AEC"
url: https://www.aecups.com/us/technology/
description: "AEC UPS technology explained with catalog data: online double conversion, LiFePO4 lithium and BMS, modular N+X, efficiency and SiC, monitoring."
language: en-US
---

Technology

# How AEC UPS systems work.

Seven deep dives with the catalog's figures, the app's diagrams and the real displays: online double conversion, LiFePO4 lithium, modular redundancy, efficiency, monitoring, isolation transformers and the history of the power switch. [Open the cabinets](https://www.aecups.com/us/3d/), switch the operating modes and read the curves.

**Online double conversion** How an AEC UPS keeps the load on: rectifier, DC bus, inverter, static and maintenance bypass, and the six operating modes on the real display. Read

**Lithium LiFePO4 and BMS** Lithium iron phosphate modules, the battery management system, the L6 cabinet opened up, and state of health against lead-acid. Read

**Modular UPS and N+X** Power modules in a frame, hot-swap, redundancy and parallel systems, from 15 kVA modules to 1.6 MW. Read

**Efficiency and silicon carbide** Each series' efficiency curve from the catalog, SiC and 3-level IGBT, and what a point of efficiency is worth. Read

**Monitoring and communication** Network cards, Modbus, dry contacts, the monitoring cloud and the touchscreens, series by series. Read

**Isolation transformers** Galvanic isolation, a new neutral, voltage change: what a transformer does in a UPS and when one is needed. Read

**From thyristor to silicon carbide** Seventy years of the UPS power switch: SCR, BJT, MOSFET, IGBT, 3-level IGBT and SiC, era by era, with what AEC uses today. Read

Short answers

## What do these articles answer?

**[What does online double conversion mean?](https://www.aecups.com/us/technology/online-double-conversion/)** The rectifier and the inverter run all the time, so the load is always fed by the inverter and nothing transfers when the utility fails: 0 ms. Every AEC UPS works this way.

**[Is a lithium UPS battery safe?](https://www.aecups.com/us/technology/lithium-lifepo4/)** AEC uses lithium iron phosphate (LiFePO4), the lithium chemistry least prone to thermal runaway, in 50 Ah modules each watched by a battery management system and each on its own DC/DC converter.

**[What is N+1 redundancy in a modular UPS?](https://www.aecups.com/us/technology/modular-ups/)** One power module more than the load needs: a module can fail or be swapped while the others carry the load on the inverter.

**[How much does UPS efficiency save?](https://www.aecups.com/us/technology/efficiency/)** Losses are the load times (1 ÷ efficiency − 1): at a steady 100 kW, 96 % loses 4.2 kW, about 36,500 kWh a year, and 97.5 % loses 2.6 kW.

**[How is a UPS monitored over the network?](https://www.aecups.com/us/technology/monitoring/)** With a network card (SNMP v1, v2c and v3, Modbus TCP), a dry-contact relay card for alarms, or the UPS's own touchscreen.

**[Which power semiconductors do AEC UPS use?](https://www.aecups.com/us/technology/power-electronics-history/)** 3-level IGBTs in FERRUS, ETHERNO, AUREON, RADIANT and CIRRO, and silicon carbide (SiC) in INFINITE, the last two steps of a line that began with the thyristor in 1957.

**[When does a UPS need an isolation transformer?](https://www.aecups.com/us/technology/isolation-transformer-ups/)** When the load needs galvanic isolation from the supply, a new neutral, or a different voltage, such as 208/120 V loads behind a 480 V UPS.

## Talk to an engineer

Tell us the load, the voltage and the minutes you need. We answer with the model and the batteries that fit.

[Send your project](https://www.aecups.com/us/contacts/#form) [+1 786 553 2100](tel:+17865532100)