title: "UPS tools: sizing, explorers, diagrams, simulators | AEC"
url: https://www.aecups.com/us/tools/
description: "Free AEC UPS tools: size a UPS, amps from kVA, compare models, open the cabinets, try the displays, watch the diagrams, lithium vs VRLA."
language: en-US
---

Tools

# UPS tools: size, compare and try before it ships

The tools AEC engineers use, in the order of a project: size the UPS, specify it, decide on the battery, service it. Most are open to everyone; the full versions are for AEC partners.

**7**tools **8**hands-on explorers **8**live diagrams **Free**to size and compare

Online double conversion: the load always runs on the inverter; the battery sits on the DC bus.

Size and specify

## From the load to the right model.

In the order of a project: each tool hands on to the next.

[1 · Start here **UPS sizing** Supply and load in, the AEC models that carry it out, closest size first, with runtime. Or start from the UPS you replace.](https://www.aecups.com/us/tools/ups-sizing/) [1 · Replacing a UPS **Cross reference** Type the model on the label of the UPS you have: the AEC model that replaces it.](https://www.aecups.com/us/cross-reference/) [2 · Specify **Room fit** The UPS in your room to the inch: clearances, NEC working space, door swing, breaker reach and the way in, in plan and 3D.](https://www.aecups.com/us/tools/room-fit/) [3 · Decide **Battery runtime** Any 12 V VRLA block on its datasheet table: your bank, your load, new and at end of life.](https://www.aecups.com/us/tools/battery-runtime/) [4 · Service **Battery replacement** The block in your AEC UPS and how many, or the battery on the label and the AEC block for it.](https://www.aecups.com/us/tools/battery-replacement/) [Explore **UPS in 3D** Ten AEC systems in 3D: turn them, open the doors, pull a module and see inside with the X-ray.](https://www.aecups.com/us/3d/) [Learn **Display simulators** The real screens of six AEC displays, to try: states, pages, guided tours.](https://www.aecups.com/us/tools/simulators/)

Quick calculator

## Amps, kVA and kW in one line.

Type the rating, pick the supply: the current per phase and the real power, with the waveform of that supply.

At the UPS output, full load. The input current is higher by the losses and the battery charge; breakers and cables follow the manual and local code. [See the UPS for this supply](https://www.aecups.com/us/products/three-phase-ups-208v/) · [Size it properly](https://www.aecups.com/us/tools/ups-sizing/)

Current per phase **—**

Real power **—**

Formula **—**

Hands-on

## Open it up. Pull a module.

The real cabinets, from the catalog photos: doors that open, modules that slide out, numbers on every part.

[**ETHERNO** Open the door, pull a lithium module, turn it around to the rear panel.](https://www.aecups.com/us/products/etherno/#inside) [**INFINITE + L6** Pull power modules (N+1), lithium modules, and read the wave screen.](https://www.aecups.com/us/products/infinite/#inside) [**L6 cabinet planner** Pick the module, the minutes and the kVA: the cabinets draw themselves.](https://www.aecups.com/us/products/lithium-batteries/#plan) [**Inside a lithium module** Its parts, and parallel against series: fail a module and see what happens.](https://www.aecups.com/us/products/lithium-batteries/#lithium-module) [**Container builder** Drag UPS systems in, up to 1.2 MW: AC, switchgear and the CAD plan follow.](https://www.aecups.com/us/products/containerized-ups/#build) [**LUMINA rear panel** Every outlet, port and fan, numbered on the 1 and 3 kVA.](https://www.aecups.com/us/products/lumina/#inside) [**RADIANT modules** The modular frame taken apart, part by part.](https://www.aecups.com/us/products/radiant/#inside) [**CIRRO** The large frame opened: power modules and their bays.](https://www.aecups.com/us/products/cirro/#inside)

Diagrams and schemes

## Watch the power move.

Interactive diagrams across the site: modes, curves, floor plans and dashboards.

[Diagram **Operating modes** Normal, battery, bypass, ECO: pick one and watch the power move.](https://www.aecups.com/us/technology/online-double-conversion/) [Diagram **Cut the power** The grid fails: what the UPS does in that instant.](https://www.aecups.com/us/blog/what-is-a-ups/) [Diagram **Efficiency curves** Every series at your load, and what a point of efficiency is worth a year.](https://www.aecups.com/us/technology/efficiency/) [Diagram **Battery life vs temperature** Move the room temperature, watch the years go.](https://www.aecups.com/us/products/batteries/#temp) [Diagram **Example designs** Office, hospital, data center, factory: scaled floor plans with the UPS in place.](https://www.aecups.com/us/example-designs/) [Diagram **Cloud monitoring** A live demo of the dashboard: every UPS, every alarm.](https://www.aecups.com/us/cloud/#demo) [Diagram **Modular and N+1** Power modules in a frame, and why the spare matters.](https://www.aecups.com/us/technology/modular-ups/) [Diagram **kW, kVA, power factor** The power triangle, with a calculator.](https://www.aecups.com/us/blog/ups-sizing/)

## Talk to an engineer

Tell us the load, the voltage and the minutes you need. We answer with the model and the batteries that fit.

[Send your project](https://www.aecups.com/us/contacts/#form) [+1 786 553 2100](tel:+17865532100)