120/240 V · 6–20 kVA
120/240V split-phase UPS, 6 to 20 kVA
A split-phase UPS serves 120/240 V panels: two 120 V legs and a neutral, 240 V between the legs, common in small commercial buildings, clinics and offices. AEC offers two online series for it, with an isolation transformer and a maintenance bypass: FERRUS SP, a tower from 6 to 20 kVA, and FERRUS SP RT, a rack/tower from 6 to 10 kVA.
A split-phase UPS serves 120/240 V single-phase panels: two 120 V legs and a neutral, with 240 V between the legs. It is one of the most common services in the US, in small commercial buildings, clinics, offices and homes, and it feeds both 240 V loads and 120 V circuits.
AEC offers two online double-conversion series for it, both with an integrated isolation transformer and a manual maintenance bypass: FERRUS SP, a tower from 6 to 20 kVA, and FERRUS SP RT, a rack/tower from 6 to 10 kVA.
Series
The two AEC series for 120/240 V split-phase

FERRUS SP
Online double-conversion UPS for split-phase 120/240 V loads from 6 to 20 kVA, in a tower cabinet, with VRLA batteries.
View series
FERRUS SP RT
Online double-conversion UPS for split-phase 120/240 V loads from 6 to 10 kVA, in a 19-inch rack, with external 3U rack battery cabinets of 16 × 12 V 9 Ah VRLA blocks, the first one included.
View seriesCompare
120/240V split-phase UPS models compared.
| Series | Power | Supply | Battery | Form | Efficiency | Warranty | Models |
|---|---|---|---|---|---|---|---|
| FERRUS SP | 6–20 kVA | 120/240 V, split-phase | VRLA batteries | Tower | 93% | 3 years | 3 |
| FERRUS SP RT | 6–10 kVA | 120/240 V, split-phase | VRLA: each UPS comes with a 3U rack cabinet of 16 × 12 V 9 Ah blocks | Rack | 93% | 3 years | 2 |
Range
Which one carries your load?
Drag to your load in kVA.
Guides
Read before you choose.

UPS for offices, retail and small business
9 min read
Protect a small office, a store or a clinic in the US: 120 V and 120/240 V UPS, NEMA receptacles, runtime packs, lithium or VRLA, and what to plug in.

UPS for hospitals and clinics: 120/240 V, 208 V and 480 V
9 min read
Where a UPS fits in a US healthcare building: the 10-second generator gap, IT and nurse-call loads, 120 V to 480 V, and the AEC series for each.

How to size a UPS: five steps to the power you need
10 min read
Size a UPS in five steps: load in watts, kVA and kW, voltage and phase, runtime, and room to grow. With a calculator.
Questions
Questions people ask
What is a split-phase UPS?
A UPS whose input and output are 120/240 V split phase: two 120 V legs 180 degrees apart and a neutral. Loads connect at 240 V between the legs or at 120 V from a leg to the neutral.
240 V or 208 V: what is the difference?
240 V comes from a split-phase service; 208 V is measured between two legs of a three-phase 208Y/120 V service. Check the equipment's nameplate: some equipment accepts both, some only one. For a three-phase 208 V panel, see the 208V three-phase UPS.
Can a split-phase UPS run a motor or a well pump?
Yes, if the UPS is sized for the starting current: motors draw several times their running current when they start, so size for that, not for the running watts: send us the motor's nameplate and our engineers size it.
Talk to an engineer
Tell us the load, the voltage and the minutes you need. We answer with the model and the batteries that fit.