Three-phase 480 V UPS
CIRRO-IB modular UPS, 30–150 kVA, 480 V
CIRRO-IB is AEC's modular online UPS with N+X redundancy for three-phase 480 V, 4-wire loads from 30 to 150 kVA, with internal hot-swappable VRLA battery trays. For 30 kVA modular at 480 V, the CIRIB150-1X30 is one 30 kVA power module in the frame; at 208 V it is the RADIANT RAD90-2X15, two 15 kVA modules.
Drag to turnIn 3D
Look around the CIRRO-IB
Drag it round, swipe on a phone or use the arrow keys. X-ray makes the enclosure see-through, so you can see what sits behind the panels.
Rendered from AEC's 3D model of the CIRRO-IB 30–150 kVA. The full 3D view zooms in, opens the unit and names every part.
Hands on
Open the CIRRO-IB yourself.
Click the unit: the door opens, then a module comes out. Drag to move it by hand. The 3D shows every part.
Efficiency
How efficient is the CIRRO-IB at your load?
The CIRRO-IB in normal double-conversion mode, from the 2026 catalog's efficiency curve. Drag along it to see the heat lost and its yearly cost.
- Load
- —
- Lost as heat
- —
- Heat to remove
- —
- Energy lost in a year, 24/7
- —
- Its cost in a year at per kWh
- —
The display
The CIRRO-IB display.
The real touchscreen, from the user manual: pick a main page, or touch the screen as on the UPS.

RADIANT · CIRRO · the real screen
Home
The home page after the welcome window: status bar, output voltage gauges, battery bars, energy flow and warning information, with the main menu on the left.
What is what
Inside the CIRRO-IB, part by part.
Each number is named in the list under its picture: the front with its door open and the rear, side by side.
Front, door open

- 5 power-module slots30 kVA modules, hot-swappable; No. 1 at the bottom, No. 5 at the top.
- Bypass & monitoring moduleCommunication panel and fans.
- Battery trays, 4 per row × 6 rows = 24Ten 12 V blocks in each tray.
- TouchscreenOn the door, seen here from inside.
- Base and anchor boltsFour anchor bolts and no casters: the cabinet is moved with a pallet truck or a forklift.
Rear, doors open

- Module backplaneThe power modules seen from the rear, with their busbars.
- Battery breakerConnects the internal battery trays to the DC bus of the power modules.
- Output, maintenance and input breakersLeft to right: output to the load; maintenance bypass, normally OFF, around the whole UPS for service; main input to the rectifiers.
- Terminal coverBehind it the power terminals.
- Rear doorsTwo: the breakers and the power terminals are reached from the rear.
- Touchscreen7-inch, on the front door.
Overview
Key facts
- Power range
- 30–150 kVA
- Technology
- 3-level IGBT; unity power factor (kVA = kW); 40 A settable charger
- Input / Output
- 480/277 V three-phase, 4-wire
- Battery
- internal hot-swappable VRLA, up to 240 × 12V 9Ah (240 pcs)
- Display
- 7-inch color touchscreen
- Comms
- RS-232, EPO and USB, standard
- Power factor
- 1.0 (kVA = kW)
- Network card
- SNMP-M (SNMP)
- Warranty
- 3 years on UPS · 2 years on VRLA batteries
- Quality system
- ISO 9001:2015, the group's quality system (SGS)
Models
Which CIRRO-IB fits your load?
5 models for the US market, from the 2026 catalog. Pick the power, open a model for its full datasheet.
CIRIB150-1X3030 kVA · 30 kW1 × 30 kVA power module, 240 × 12 V 9 Ah VRLA blocks inside2,191.8 lbnet weightInternal Tray SystembatteriesDetails and datasheet
CIRIB150-2X3060 kVA · 60 kW2 × 30 kVA power modules, 240 × 12 V 9 Ah VRLA blocks inside2,243.8 lbnet weightInternal Tray SystembatteriesDetails and datasheet
CIRIB150-3X3090 kVA · 90 kW3 × 30 kVA power modules, 240 × 12 V 9 Ah VRLA blocks inside2,295.8 lbnet weightInternal Tray SystembatteriesDetails and datasheet
CIRIB150-4X30120 kVA · 120 kW4 × 30 kVA power modules, 240 × 12 V 9 Ah VRLA blocks inside2,347.8 lbnet weightInternal Tray SystembatteriesDetails and datasheet
CIRIB150-5X30150 kVA · 150 kW5 × 30 kVA power modules, 240 × 12 V 9 Ah VRLA blocks inside2,399.8 lbnet weightInternal Tray SystembatteriesDetails and datasheet Options and parts for CIRRO-IB
- CIRIB-BATTR-10x9ABattery Tray incl. 10 × 12 V 9 Ah
- CIRIB-BATTR-EMPTYBattery Tray empty
- CIRIB-FRAMECIRRO-IB 150 kVA Frame — no power module, no battery trays, 5 module slots23.6" W × 39.4" D × 78.7" H (600 × 1,000 × 2,000 mm) · 616 lb (279.4 kg)
- CIRIB-PWR-30Power Module 30 kVA — CIRRO-IB17.3" W × 26.7" D × 3.4" H (440 × 678 × 85 mm) · 52 lb (23.6 kg)
Datasheet
CIRRO-IB datasheet.
Every model side by side. Filter by power, keep only what differs, print it or take it as CSV.
| Model | CIRIB150-1X30 | CIRIB150-2X30 | CIRIB150-3X30 | CIRIB150-4X30 | CIRIB150-5X30 |
|---|---|---|---|---|---|
| Power | |||||
| Rated power (kVA) | 30 | 60 | 90 | 120 | 150 |
| Active power (kW) | 30 | 60 | 90 | 120 | 150 |
| Output power factor | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 |
| Electrical | |||||
| Input / output | 480 V three-phase, 4-wire (3P+N) | 480 V three-phase, 4-wire (3P+N) | 480 V three-phase, 4-wire (3P+N) | 480 V three-phase, 4-wire (3P+N) | 480 V three-phase, 4-wire (3P+N) |
| Topology | Online double conversion, modular N+X | Online double conversion, modular N+X | Online double conversion, modular N+X | Online double conversion, modular N+X | Online double conversion, modular N+X |
| Efficiency, up to | 96% | 96% | 96% | 96% | 96% |
| Battery DC bus | 480 V DC | 480 V DC | 480 V DC | 480 V DC | 480 V DC |
| Battery and runtime | |||||
| Battery type | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) |
| Battery configuration | Internal Tray System | Internal Tray System | Internal Tray System | Internal Tray System | Internal Tray System |
| Runtime at 50 % load | 45 min | 14 min | 10.5 min | 6 min | 6 min |
| Runtime at 100 % load | 14 min | 6 min | 3 min | 2 min | — |
| Mechanical | |||||
| Form factor | Modular | Modular | Modular | Modular | Modular |
| Dimensions W × D × H | 23.6 × 39.3 × 78.7 in (599 × 998 × 1,999 mm) | 23.6 × 39.3 × 78.7 in (599 × 998 × 1,999 mm) | 23.6 × 39.3 × 78.7 in (599 × 998 × 1,999 mm) | 23.6 × 39.3 × 78.7 in (599 × 998 × 1,999 mm) | 23.6 × 39.3 × 78.7 in (599 × 998 × 1,999 mm) |
| Net weight | 2,191.8 lb (994.2 kg) | 2,243.8 lb (1,017.8 kg) | 2,295.8 lb (1,041.4 kg) | 2,347.8 lb (1,065 kg) | 2,399.8 lb (1,088.6 kg) |
| Footprint | 6.4 ft² (0.60 m²) | 6.4 ft² (0.60 m²) | 6.4 ft² (0.60 m²) | 6.4 ft² (0.60 m²) | 6.4 ft² (0.60 m²) |
| Shipping | |||||
| Cartons | 26 | 27 | 28 | 29 | 30 |
From the AEC 2026 catalog. Efficiency is the catalog's “up to” figure; runtimes are AEC's runtime tables with new batteries; weights are the unit alone, without batteries outside it. Figures can change: the order confirmation rules.
Downloads
Manuals and catalogs.
The CIRRO-IB documents in English, as PDF.
Catalogs and datasheets
Installation
What does the CIRRO-IB need in the room?
From the AEC US user manual of the CIRRO-IB. Where the manual gives no distance, none is printed here: ask AEC.
- Clearances
- Front 36 in (914 mm, NEC; AEC's own minimum is 31.5 in / 800 mm), rear 19.7 in (500 mm), top 19.7 in (500 mm). Sides: not given.
- Wiring
- Hardwired: an electrician connects it to the panel.
- Cable entry
- Top of the rear compartment; Bottom, through the opening in the base (Optional bottom-entry cable assembly: size from AEC)
- Breakers and terminals
- Battery, output, maintenance (225 A in the 150 kVA cabinet) and main input breakers on the rear panel. NO bypass input breaker in the cabinet: always provide one upstream.
- Door
- One perforated front door, two rear doors; hinge side not given.
- Space to pull a module
- Keep at least 26.7 in (678 mm) free in front to slide a module out.
- Units in parallel
- Up to 3 of the same model.
Install and run it:CIRRO-IB installation and operation manualRADIANT and CIRRO touch screen guide
Plan it:Size it for your loadRoom fitCIRRO-IB compared with other makersWarranty terms
Replacing another brand's UPS?Type its model number: the AEC match
CIRRO-IB: quick answers
Questions people ask
What sizes does CIRRO-IB come in?
30 to 150 kVA, in 5 models of the 2026 catalog for the US, from the CIRIB150-1X30 (30 kVA) to the CIRIB150-5X30 (150 kVA). The datasheet on this page gives every one.
What supply does CIRRO-IB need?
480/277 V three-phase, 4-wire, for every model of the series. Its power factor is 1.0, so each model gives its kVA rating in kW.
What batteries does CIRRO-IB use?
Internal hot-swappable VRLA, up to 240 × 12 V 9 Ah blocks. The battery bus is 480 V DC on every model.
What warranty does CIRRO-IB have?
3 years on UPS; 2 years on VRLA batteries, from start-up. Register the UPS with AEC after start-up.
How is CIRRO-IB monitored over the network?
With the AEC SNMP-M network card, which reports the UPS status and alarms over SNMP to your monitoring software.
How much power do 3 CIRIB150-1X30 give in parallel?What is the output current of each CIRRO-IB model?How much heat does each CIRRO-IB model give off?All 9 questions
Also in 480V three-phase UPS:CIRROINFINITEINFINITE 1.5MWCompare the range
The CIRRO-IB for your project
Send the load, the voltage and the minutes. We reply with the CIRRO-IB model that fits, its batteries and the lead time.