Single-phase 120 V UPS
LUMINA online UPS, 1–3 kVA, 120 V
LUMINA is AEC's online double-conversion UPS for single-phase 120 V loads from 1 to 3 kVA, in a 19-inch rack, with internal LiFePO4 lithium batteries. The battery sits inside the 2U chassis, the color LCD rotates, and RS232, EPO and USB are standard; a telescopic rail kit is available.
Drag to turnIn 3D
Look around the LUMINA
Drag it round, swipe on a phone or use the arrow keys. X-ray makes the enclosure see-through, so you can see what sits behind the panels.
Rendered from AEC's 3D model of the LUMINA 1–3 kVA. The full 3D view zooms in, opens the unit and names every part.
Efficiency
How efficient is the LUMINA at your load?
The LUMINA in normal double-conversion mode, from the 2026 catalog's efficiency curve. Drag along it to see the heat lost and its yearly cost.
- Load
- —
- Lost as heat
- —
- Heat to remove
- —
- Energy lost in a year, 24/7
- —
- Its cost in a year at per kWh
- —
Runtime
How long does each LUMINA model run at your load?
From the 2026 catalog's runtime tables, new batteries. Drag the load, type it in kW, or move along the chart. Click a model for its page.
At 50 % of the rating
LUMINA 1 kVA
LiFePO4 inside27 minLUMINA 1.5 kVA
LiFePO4 inside27 minLUMINA 2 kVA
LiFePO4 inside27 minLUMINA 2.2 kVA
LiFePO4, extended runtime46 minLUMINA 3 kVA
LiFePO4 inside27 minTable: every model at 25, 50, 75 and 100 % load
| Model | 25% load | 50% load | 75% load | 100% load |
|---|---|---|---|---|
| LUMINA 1 kVA · LiFePO4 insideLUM1000RT-2U-LI | 55 min | 27 min | 19 min | 11 min |
| LUMINA 1.5 kVA · LiFePO4 insideLUM1500RT-2U-LI | 55 min | 27 min | 19 min | 11 min |
| LUMINA 2 kVA · LiFePO4 insideLUM2000RT-2U-LI | 55 min | 27 min | 19 min | 11 min |
| LUMINA 2.2 kVA · LiFePO4, extended runtimeLUM2200RT-2U-LI | 98 min | 46 min | 34.5 min | 23 min |
| LUMINA 3 kVA · LiFePO4 insideLUM3000RT-2U-LI | 55 min | 27 min | 19 min | 11 min |
The display
The LUMINA display.
The real screen, from the user manual: its guided tours, step by step.
The display reads OUTPUT 120 Vac
Inverter off and back on
The UPS runs online on mains.
You seeMains icon lit, OUTPUT 120 Vac.
What is what
Inside the LUMINA, part by part.
Each number on the picture is named in the list.
Rear · 1 kVA
12345678- Intelligent slotFor an SNMP network card or a dry-contact card; the -NC models ship with the SNMP card fitted.
- Cooling fanOne fan on the 1 kVA; the air leaves at the rear.
- EPOEmergency power off contact.
- USB portTo a computer, for the monitoring and shutdown software.
- Circuit protectorThe input breaker: press it to reset after an overload.
- Input: C14 inletIEC C14 inlet for the supply cord.
- 8 × NEMA 5-15R outletsThe protected outputs, 120 V.
- Battery connectorDC input of the internal battery.
Rear · 1.5–2.2 kVA
12345678- Intelligent slotFor an SNMP network card or a dry-contact card; the -NC models ship with the SNMP card fitted.
- Two cooling fansTwo fans on the 1.5, 2, 2.2 and 3 kVA; the air leaves at the rear.
- EPOEmergency power off contact.
- USB portTo a computer, for the monitoring and shutdown software.
- Circuit protectorThe input breaker: press it to reset after an overload.
- Input: C20 inlet + 5 ft cordIEC C20 inlet; the 5 ft supply cord plugs in with its C19 connector.
- 6 × NEMA 5-20R outletsThe protected outputs, 120 V, 20 A receptacles.
- Battery connectorDC input of the internal battery.
Rear · 3 kVA
123456789- Intelligent slotFor an SNMP network card or a dry-contact card; the -NC models ship with the SNMP card fitted.
- Two cooling fansTwo fans on the 1.5, 2, 2.2 and 3 kVA; the air leaves at the rear.
- EPOEmergency power off contact.
- USB portTo a computer, for the monitoring and shutdown software.
- Circuit protectorThe input breaker: press it to reset after an overload.
- Input: NEMA L5-30P plugLocking 30 A plug on a 5 ft cord.
- 1 × NEMA L5-30R outletA locking 30 A output for the larger load.
- 4 × NEMA 5-20R outletsThe protected outputs, 120 V, 20 A receptacles.
- Battery connectorDC input of the internal battery.
Overview
Key facts
- Power range
- 1–3 kVA
- Input / Output
- 110/120 V, 50–60 Hz, single-phase
- Battery
- internal LiFePO4 lithium — about 2.6 times the full-load runtime of the VRLA FERRUS RT of the same rating at 1, 2 and 3 kVA (11 against 4.2 min), about 1.8 times at 1.5 kVA (11 against 6 min), each at its own full load, 12–15 year life (3,000 cycles)
- Display
- rotating color LCD
- Comms
- RS-232, EPO and USB, standard
- Form factor
- 2U rack; telescopic rail kit available
- Power factor
- 0.9
- Network card
- SNMP-L (SNMP)
- Warranty
- 5 years incl. lithium batteries
- Certification
- ETL Listed to UL 1778 and CSA C22.2 No. 107.3
- Quality system
- ISO 9001:2015, the group's quality system (SGS)
Models
Which LUMINA fits your load?
5 models for the US market, from the 2026 catalog. Pick the power, open a model for its full datasheet.
LUM1000RT-2U-LI1 kVA · 0.9 kWrack 2U, lithium LiFePO427 minat 50 % load19.6 lbnet weightDetails and datasheet
LUM1500RT-2U-LI1.5 kVA · 1.35 kWrack 2U, lithium LiFePO427 min, AEC estimateat 50 % load32.4 lbnet weightDetails and datasheet
LUM2000RT-2U-LI2 kVA · 1.8 kWrack 2U, lithium LiFePO427 minat 50 % load30 lbnet weightDetails and datasheet
LUM2200RT-2U-LI2.2 kVA · 1.98 kWrack 2U, lithium LiFePO446 minat 50 % load42.1 lbnet weightDetails and datasheet
LUM3000RT-2U-LI3 kVA · 2.7 kWrack 2U, lithium LiFePO427 minat 50 % load37.7 lbnet weightDetails and datasheet Datasheet
LUMINA datasheet.
Every model side by side. Filter by power, keep only what differs, print it or take it as CSV.
| Model | LUM1000RT-2U-LI | LUM1500RT-2U-LI | LUM2000RT-2U-LI | LUM2200RT-2U-LI | LUM3000RT-2U-LI |
|---|---|---|---|---|---|
| Power | |||||
| Rated power (kVA) | 1 | 1.5 | 2 | 2.2 | 3 |
| Active power (kW) | 0.9 | 1.35 | 1.8 | 1.98 | 2.7 |
| Output power factor | 0.9 | 0.9 | 0.9 | 0.9 | 0.9 |
| Electrical | |||||
| Input / output | 120 V single-phase | 120 V single-phase | 120 V single-phase | 120 V single-phase | 120 V single-phase |
| Topology | Online Double Conversion | Online Double Conversion | Online Double Conversion | Online Double Conversion | Online Double Conversion |
| Efficiency, up to | 91.7% | 92.5% | 92.5% | 92.6% | 92.5% |
| Battery DC bus | 24 V DC | 48 V DC | 48 V DC | 72 V DC | 72 V DC |
| Battery and runtime | |||||
| Battery type | Lithium LiFePO4 | Lithium LiFePO4 | Lithium LiFePO4 | Lithium LiFePO4 | Lithium LiFePO4 |
| Battery configuration | Internal | Internal | Internal | Internal | Internal |
| Runtime at 50 % load | 27 min | 27 min, AEC estimate | 27 min | 46 min | 27 min |
| Runtime at 100 % load | 11 min | 11 min | 11 min | 23 min | 11 min |
| Mechanical | |||||
| Form factor | Rack 2U | Rack 2U | Rack 2U | Rack 2U | Rack 2U |
| Dimensions W × D × H | 17.2 × 16.5 × 3.4 in (438 × 420 × 87 mm) | 17.2 × 22.6 × 3.4 in (437 × 574 × 86 mm) | 17.2 × 22.4 × 3.4 in (438 × 570 × 87 mm) | 17.2 × 24.2 × 3.4 in (438 × 615 × 87 mm) | 17.2 × 22.4 × 3.4 in (438 × 570 × 87 mm) |
| Net weight | 19.6 lb (8.9 kg) | 32.4 lb (14.7 kg) | 30 lb (13.6 kg) | 42.1 lb (19.1 kg) | 37.7 lb (17.1 kg) |
| Footprint | 2.0 ft² (0.18 m²) | 2.7 ft² (0.25 m²) | 2.7 ft² (0.25 m²) | 2.9 ft² (0.27 m²) | 2.7 ft² (0.25 m²) |
| Shipping | |||||
| Cartons | 1 | — | 1 | 1 | 1 |
| Shipping weight | 33.5 lb | — | 44.5 lb | 57.1 lb | 51.4 lb |
From the AEC 2026 catalog. Efficiency is the catalog's “up to” figure; runtimes are AEC's runtime tables with new batteries; weights are the unit alone, without batteries outside it. Figures can change: the order confirmation rules.
Downloads
Manuals and catalogs.
The LUMINA documents in English, as PDF.
Installation
What does the LUMINA need in the room?
From the AEC US user manual of the LUMINA. Where the manual gives no distance, none is printed here: ask AEC.
- Clearances
- 12–20 in (300–500 mm) free around the UPS and 20 in (500 mm) above it.
- Wiring
- Plug-in: cords at the rear panel.
- Cable entry
- Plug-in, at the rear
- Breakers and terminals
- Input circuit protector and every connection on the rear panel: keep the rear reachable.
Install and run it:LUMINA operating guide
Plan it:Size it for your loadBattery runtimeRoom fitLUMINA compared with other makersWarranty terms
Replacing another brand's UPS?Type its model number: the AEC match
LUMINA: quick answers
Questions people ask
How long does LUMINA run on battery?
The LUM1000RT-2U-LI, LUM2000RT-2U-LI and LUM3000RT-2U-LI run 11 min at full load and 27 min at half load. The LUM1500RT-2U-LI runs 11 min at full load and 27 min at half load (AEC estimate). The LUM2200RT-2U-LI runs 23 min at full load and 46 min at half load. Figures from the 2026 catalog runtime tables, with new batteries.
How many watts does LUMINA deliver?
Its power factor is 0.9, so watts are 90 % of the VA: 1,000 VA gives 900 W, 1,500 VA gives 1,350 W, 2,000 VA gives 1,800 W, 2,200 VA gives 1,980 W, 3,000 VA gives 2,700 W.
How much rack space does LUMINA take?
2U of a 19-inch rack: 3.4 in high, 16.5 to 24.2 in deep depending on the model, with a telescopic rail kit available. Check the rack's usable depth before you order.
What warranty does LUMINA have?
5 years including the lithium batteries, from start-up. LUMINA is ETL Listed, as the 2026 catalog shows.
How long does each LUMINA model run on battery?What is the output current of each LUMINA model?How much heat does each LUMINA model give off?All 8 questions
Also in 120V single-phase UPS:FERRUSFERRUS RTCompare the range
The LUMINA for your project
Send the load, the voltage and the minutes. We reply with the LUMINA model that fits, its batteries and the lead time.