Three-phase 208 V UPS
RADIANT-IB modular UPS, 20–100 kVA, 208 V
RADIANT-IB is AEC's modular online UPS with N+X redundancy for three-phase 208 V loads from 20 to 100 kVA, with internal hot-swappable VRLA battery trays. Power modules of 20 kVA and up to 240 blocks of 12 V 9 Ah share one frame, the batteries in hot-swappable trays.
Drag to turnIn 3D
Look around the RADIANT-IB
Drag it round, swipe on a phone or use the arrow keys. X-ray makes the enclosure see-through, so you can see what sits behind the panels.
Rendered from AEC's 3D model of the RADIANT-IB 20–100 kVA. The full 3D view zooms in, opens the unit and names every part.
Hands on
Open the RADIANT-IB yourself.
Click the unit: the door opens, then a module comes out. Drag to move it by hand. The 3D shows every part.
Efficiency
How efficient is the RADIANT-IB at your load?
The RADIANT-IB in normal double-conversion mode, from the 2026 catalog's efficiency curve. Drag along it to see the heat lost and its yearly cost.
- Load
- —
- Lost as heat
- —
- Heat to remove
- —
- Energy lost in a year, 24/7
- —
- Its cost in a year at per kWh
- —
The display
The RADIANT-IB display.
The real touchscreen, from the user manual: pick a main page, or touch the screen as on the UPS.

RADIANT · CIRRO · the real screen
Home
The home page after the welcome window: status bar, output voltage gauges, battery bars, energy flow and warning information, with the main menu on the left.
What is what
Inside the RADIANT-IB, part by part.
Each number is named in the list under its picture: the front with its door open and the rear, side by side.
Front, door open

- Power modules, 20 kVA: up to 5Slot No. 1 at the bottom: fit modules from the bottom up.
- Bypass & monitoring moduleIts communication panel and fans.
- Battery trays: 6 rows of 4, 24 traysEach tray plugs in with its own 50 A connector.
- A tray drawn outTen 12 V blocks.
Rear, doors open

- Module backplaneThe power modules seen from the rear, with their busbars.
- Battery breakerConnects the internal battery trays to the DC bus of the power modules.
- Output, maintenance and input breakersLeft to right: output to the load; maintenance bypass, normally OFF, around the whole UPS for service; main input to the rectifiers.
- Terminal coverBehind it the power terminals.
- Rear doorsTwo: the breakers and the power terminals are reached from the rear.
- Touchscreen7-inch, on the front door.
Overview
Key facts
- Power range
- 20–100 kVA
- Technology
- 3-level IGBT; unity power factor (kVA = kW); 40 A settable charger
- Input / Output
- 208/120 V three-phase
- Battery
- internal hot-swappable VRLA, up to 240 × 12V 9Ah (240 pcs)
- Display
- 7-inch color touchscreen
- Comms
- RS-232, EPO and USB, standard
- Power factor
- 1.0 (kVA = kW)
- Network card
- SNMP-M (SNMP)
- Warranty
- 3 years on UPS · 2 years on VRLA batteries
- Quality system
- ISO 9001:2015, the group's quality system (SGS)
Models
Which RADIANT-IB fits your load?
5 models for the US market, from the 2026 catalog. Pick the power, open a model for its full datasheet.
RADIB100-1X2020 kVA · 20 kW1 × 20 kVA power module, 240 × 12 V 9 Ah VRLA blocks inside1,998 lbnet weightInternal Tray SystembatteriesDetails and datasheet
RADIB100-2X2040 kVA · 40 kW2 × 20 kVA power modules, 240 × 12 V 9 Ah VRLA blocks inside2,042 lbnet weightInternal Tray SystembatteriesDetails and datasheet
RADIB100-3X2060 kVA · 60 kW3 × 20 kVA power modules, 240 × 12 V 9 Ah VRLA blocks inside2,086 lbnet weightInternal Tray SystembatteriesDetails and datasheet
RADIB100-4X2080 kVA · 80 kW4 × 20 kVA power modules, 240 × 12 V 9 Ah VRLA blocks inside2,130 lbnet weightInternal Tray SystembatteriesDetails and datasheet
RADIB100-5X20100 kVA · 100 kW5 × 20 kVA power modules, 240 × 12 V 9 Ah VRLA blocks inside2,174 lbnet weightInternal Tray SystembatteriesDetails and datasheet Options and parts for RADIANT-IB
- RADIB-BATTR-10x9ABattery Tray incl. 10 × 12 V 9 Ah
- RADIB-BATTR-EMPTYBattery Tray empty
- RADIB-FRAMERADIANT-IB 100 kVA Frame — no power module, no battery trays, 5 module slots23.6" W × 39.4" D × 78.7" H (600 × 1,000 × 2,000 mm) · 430 lb (195 kg)
- RADIB-PWR-20Power Module 20 kVA — RADIANT-IB17.3" W × 26.7" D × 3.4" H (440 × 678 × 85 mm) · 44 lb (20 kg)
Datasheet
RADIANT-IB datasheet.
Every model side by side. Filter by power, keep only what differs, print it or take it as CSV.
| Model | RADIB100-1X20 | RADIB100-2X20 | RADIB100-3X20 | RADIB100-4X20 | RADIB100-5X20 |
|---|---|---|---|---|---|
| Power | |||||
| Rated power (kVA) | 20 | 40 | 60 | 80 | 100 |
| Active power (kW) | 20 | 40 | 60 | 80 | 100 |
| Output power factor | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 |
| Electrical | |||||
| Input / output | 208 V three-phase, 4-wire (3P+N) | 208 V three-phase, 4-wire (3P+N) | 208 V three-phase, 4-wire (3P+N) | 208 V three-phase, 4-wire (3P+N) | 208 V three-phase, 4-wire (3P+N) |
| Topology | Online double conversion, modular N+X | Online double conversion, modular N+X | Online double conversion, modular N+X | Online double conversion, modular N+X | Online double conversion, modular N+X |
| Efficiency, up to | 94% | 94% | 94% | 94% | 94% |
| Battery DC bus | 240 V DC | 240 V DC | 240 V DC | 240 V DC | 240 V DC |
| Battery and runtime | |||||
| Battery type | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) |
| Battery configuration | Internal Tray System | Internal Tray System | Internal Tray System | Internal Tray System | Internal Tray System |
| Runtime at 50 % load | 85 min | 32 min | 21.5 min | 14 min | 12 min |
| Runtime at 100 % load | 32 min | 14 min | 8 min | 6 min | 3 min |
| Mechanical | |||||
| Form factor | Modular | Modular | Modular | Modular | Modular |
| Dimensions W × D × H | 23.6 × 39.3 × 78.7 in (599 × 998 × 1,999 mm) | 23.6 × 39.3 × 78.7 in (599 × 998 × 1,999 mm) | 23.6 × 39.3 × 78.7 in (599 × 998 × 1,999 mm) | 23.6 × 39.3 × 78.7 in (599 × 998 × 1,999 mm) | 23.6 × 39.3 × 78.7 in (599 × 998 × 1,999 mm) |
| Net weight | 1,998 lb (906.3 kg) | 2,042 lb (926.2 kg) | 2,086 lb (946.2 kg) | 2,130 lb (966.2 kg) | 2,174 lb (986.1 kg) |
| Footprint | 6.4 ft² (0.60 m²) | 6.4 ft² (0.60 m²) | 6.4 ft² (0.60 m²) | 6.4 ft² (0.60 m²) | 6.4 ft² (0.60 m²) |
| Shipping | |||||
| Cartons | 26 | 27 | 28 | 29 | 30 |
From the AEC 2026 catalog. Efficiency is the catalog's “up to” figure; runtimes are AEC's runtime tables with new batteries; weights are the unit alone, without batteries outside it. Figures can change: the order confirmation rules.
Downloads
Manuals and catalogs.
The RADIANT-IB documents in English, as PDF.
Catalogs and datasheets
Installation
What does the RADIANT-IB need in the room?
From the AEC US user manual of the RADIANT-IB. Where the manual gives no distance, none is printed here: ask AEC.
- Clearances
- Front 36 in (914 mm), rear 19.7 in (500 mm), top 19.7 in (500 mm). Sides: ask AEC.
- Wiring
- Hardwired: an electrician connects it to the panel.
- Cable entry
- Top of the rear compartment; Bottom, through the opening in the base
- Breakers and terminals
- Battery, output, maintenance and main input breakers on the rear panel behind the rear doors. The cabinet has NO bypass input breaker: always provide one upstream.
- Door
- Front door hinged on the right (from the photo); two rear doors.
Install and run it:RADIANT-IB installation and operation manualRADIANT and CIRRO touch screen guide
Plan it:Size it for your loadRoom fitRADIANT-IB compared with other makersWarranty terms
Replacing another brand's UPS?Type its model number: the AEC match
RADIANT-IB: quick answers
Questions people ask
What sizes does RADIANT-IB come in?
20 to 100 kVA, in 5 models of the 2026 catalog for the US, from the RADIB100-1X20 (20 kVA) to the RADIB100-5X20 (100 kVA). The datasheet on this page gives every one.
What supply does RADIANT-IB need?
208/120 V three-phase, for every model of the series. Its power factor is 1.0, so each model gives its kVA rating in kW.
What batteries does RADIANT-IB use?
Internal hot-swappable VRLA, up to 240 × 12 V 9 Ah blocks. The battery bus is 240 V DC on every model.
What warranty does RADIANT-IB have?
3 years on UPS; 2 years on VRLA batteries, from start-up. Register the UPS with AEC after start-up.
How is RADIANT-IB monitored over the network?
With the AEC SNMP-M network card, which reports the UPS status and alarms over SNMP to your monitoring software.
What is the output current of each RADIANT-IB model?How much heat does each RADIANT-IB model give off?Which RADIANT-IB models fit through a standard door?All 8 questions
RADIANT-IB in the field:LUMINA and RADIANT-IB UPS at a Dominican resortAll projects
Also in 208V three-phase UPS:ETHERNOAUREONRADIANTCompare the range
The RADIANT-IB for your project
Send the load, the voltage and the minutes. We reply with the RADIANT-IB model that fits, its batteries and the lead time.