Three-phase 208 V UPS

AUREON online UPS, 10–30 kVA, 208 V

VRLAOnline double conversionTower

AUREON is AEC's online double-conversion UPS for three-phase 208 V loads from 10 to 30 kVA, in a tower cabinet, with VRLA batteries. Its 12 V 9 Ah VRLA blocks sit inside the tower and are hot-swappable: the models are sold with 40, 60 or 80, and every frame takes up to 80 (20, 40, 60 or 80).

10–30kVA
94%Efficiency, up to
1.0Power factor
3 yrWarranty
AEC AUREON: Door open, VRLA battery modules

Efficiency

How efficient is the AUREON at your load?

The AUREON in normal double-conversion mode, from the 2026 catalog's efficiency curve. Drag along it to see the heat lost and its yearly cost.

—%

Load
—
Lost as heat
—
Heat to remove
—
Energy lost in a year, 24/7
—
Its cost in a year at per kWh
—

What is what

Inside the AUREON, part by part.

Each number on the picture is named in the list.

Rear, and the front with its door open

AEC AUREON from the rear, with its breakers and fans, and from the front with the door open on four VRLA battery modules
  1. Option slots and parallel portMarked SLOT1, SLOT2 and PARALLEL; Modbus and dry contacts are standard.
  2. Fans and air outletThe air enters at the front and leaves at the rear: never put the rear against a wall.
  3. Bypass breakerThe static bypass supply.
  4. Output breakerTo the load.
  5. BATT. StartCold start: powers the UPS up from its batteries when there is no mains.
  6. Maintenance breakerUnder its cover, normally OFF. Taking the cover off moves the load to bypass by itself.
  7. Input breakerThe rectifier's mains supply.
  8. Wiring coverBehind it the AC terminal block, the PE bar and the external battery block (+, N, −). Cables enter from below.
  9. Touchscreen4.3-inch color touchscreen on the front.
  10. ON/OFF keys and EPOBelow the touchscreen.
  11. VRLA battery modulesTwo to four, hot-swappable, fitted from the bottom up; empty positions closed with cover plates.
  12. Front doorKey-locked; keep it free to open fully, for the battery modules.

Open it

AUREON closedAUREON open: the hot-swappable VRLA battery drawers behind the lower door

AUREON closed

Overview

Key facts

Power range
10–30 kVA
Input / Output
208 V, three-phase
Battery
VRLA batteries
Power factor
1.0 (kVA = kW)
Network card
SNMP-L (SNMP)
Warranty
3 years on UPS · 2 years on VRLA batteries
Certification
UL 1778 listed, UL file E543003 (AEC UPS USA LLC)
Quality system
ISO 9001:2015, the group's quality system (SGS)

Datasheet

AUREON datasheet.

Every model side by side. Filter by power, keep only what differs, print it or take it as CSV.

AUREON datasheet, 8 models
ModelAUR-10AUR10-40X9AAUR10-80X9AAUR-20AUR20-60X9AAUR20-80X9AAUR-30AUR30-80X9A
Power
Rated power (kVA)1010102020203030
Active power (kW)1010102020203030
Output power factor1.01.01.01.01.01.01.01.0
Electrical
Input / output208 V three-phase, 4-wire (3P+N)208 V three-phase, 4-wire (3P+N)208 V three-phase, 4-wire (3P+N)208 V three-phase, 4-wire (3P+N)208 V three-phase, 4-wire (3P+N)208 V three-phase, 4-wire (3P+N)208 V three-phase, 4-wire (3P+N)208 V three-phase, 4-wire (3P+N)
TopologyOnline Double ConversionOnline Double ConversionOnline Double ConversionOnline Double ConversionOnline Double ConversionOnline Double ConversionOnline Double ConversionOnline Double Conversion
Efficiency, up to94%94%94%94%94%94%94%94%
Battery DC bus240 V DC240 V DC240 V DC240 V DC240 V DC240 V DC240 V DC240 V DC
Battery and runtime
Battery typeVRLA (sealed lead-acid)VRLA (sealed lead-acid)VRLA (sealed lead-acid)VRLA (sealed lead-acid)VRLA (sealed lead-acid)VRLA (sealed lead-acid)VRLA (sealed lead-acid)VRLA (sealed lead-acid)
Battery configurationFrame only, no batteries included: takes up to 80 internal 12 V 9 Ah VRLA blocks (20, 40, 60 or 80)InternalInternalFrame only, no batteries included: takes up to 80 internal 12 V 9 Ah VRLA blocks (20, 40, 60 or 80)InternalInternalFrame only, no batteries included: takes up to 80 internal 12 V 9 Ah VRLA blocks (20, 40, 60 or 80)Internal
Runtime at 50 % load—25 min60 min—13.5 min, AEC estimate20 min, AEC estimate—14 min
Runtime at 100 % load—7 min20 min—4.5 min, AEC estimate7.5 min, AEC estimate—4 min
Mechanical
Form factorTowerTowerTowerTowerTowerTowerTowerTower
Dimensions W × D × H14.9 × 39.1 × 49.2 in (378 × 993 × 1,250 mm)14.9 × 39.1 × 49.2 in (378 × 993 × 1,250 mm)14.9 × 39.1 × 49.2 in (378 × 993 × 1,250 mm)14.9 × 39.1 × 49.2 in (378 × 993 × 1,250 mm)14.9 × 39.1 × 49.2 in (378 × 993 × 1,250 mm)14.9 × 39.1 × 49.2 in (378 × 993 × 1,250 mm)14.9 × 39.1 × 49.2 in (378 × 993 × 1,250 mm)14.9 × 39.1 × 49.2 in (378 × 993 × 1,250 mm)
Net weight231 lb (104.8 kg)465 lb (210.9 kg)699 lb (317.1 kg)258 lb (117 kg)609 lb (276.2 kg)726 lb (329.3 kg)282 lb (127.9 kg)750 lb (340.2 kg)
Footprint4.0 ft² (0.38 m²)4.0 ft² (0.38 m²)4.0 ft² (0.38 m²)4.0 ft² (0.38 m²)4.0 ft² (0.38 m²)4.0 ft² (0.38 m²)4.0 ft² (0.38 m²)4.0 ft² (0.38 m²)
Shipping
Cartons—1——1——1
Shipping weight—558 lb——731 lb——900 lb

From the AEC 2026 catalog. Efficiency is the catalog's “up to” figure; runtimes are AEC's runtime tables with new batteries; weights are the unit alone, without batteries outside it. Figures can change: the order confirmation rules.

AUREON: quick answers

Questions people ask

What sizes does AUREON come in?

10 to 30 kVA, in 8 models of the 2026 catalog for the US, from the AUR-10 (10 kVA) to the AUR30-80X9A (30 kVA). The datasheet on this page gives every one.

What supply does AUREON need?

208 V, three-phase, for every model of the series. Its power factor is 1.0, so each model gives its kVA rating in kW.

What batteries does AUREON use?

VRLA batteries. The battery bus is 240 V DC on every model.

What warranty does AUREON have?

3 years on UPS; 2 years on VRLA batteries, from start-up. Register the UPS with AEC after start-up.

How is AUREON monitored over the network?

With the AEC SNMP-L network card, which reports the UPS status and alarms over SNMP to your monitoring software.

The AUREON for your project

Send the load, the voltage and the minutes. We reply with the AUREON model that fits, its batteries and the lead time.