Single-phase 120 V UPS
FERRUS RT online UPS, 1–3 kVA, 120 V
FERRUS RT is AEC's online double-conversion UPS for single-phase 120 V loads from 1 to 3 kVA, in a 19-inch rack, with internal VRLA batteries. It mounts in a 19-inch rack or stands as a tower, with the same 3-level IGBT inverter and 8 A settable charger as FERRUS.
Drag to turnIn 3D
Look around the FERRUS RT
Drag it round, swipe on a phone or use the arrow keys. X-ray makes the enclosure see-through, so you can see what sits behind the panels.
Rendered from AEC's 3D model of the FERRUS RT 1–3 kVA. The full 3D view zooms in, opens the unit and names every part.
Efficiency
How efficient is the FERRUS RT at your load?
The FERRUS RT in normal double-conversion mode, from the 2026 catalog's efficiency curve. Drag along it to see the heat lost and its yearly cost.
- Load
- —
- Lost as heat
- —
- Heat to remove
- —
- Energy lost in a year, 24/7
- —
- Its cost in a year at per kWh
- —
The display
The FERRUS RT display.
The operation panel, from our own 3D model: each number is named in the list.
Operation panel

- LCDInput and output voltage, power flow, battery, load, alarms and settings. FUNC steps through four pages: voltages and load; frequencies, battery Ah setting and model; currents and firmware; temperatures and the warning or fault code.
- REC LED (green)Steady: rectifier normal. Flashing: rectifier starting. Off: rectifier not working.
- INV LED (green)Steady: inverter normal. Flashing: starting, or tracking the bypass (ECO). Off: inverter not working.
- BYP LED (yellow)Steady: load on bypass. Flashing: bypass alarm. Off: normal mode, bypass good.
- BAT LED (yellow)Steady: battery discharging. Flashing: no battery, or battery alarm. Off: battery connected.
- ON/OFF keyPress: starts the inverter. Hold 2.5 s: load to bypass; on battery, shuts the UPS down. Without utility, press once to light the LCD, then hold 5 s for a cold start from the battery.
- FUNC keyPress: next LCD page. Hold 1.5 s on page 1: mutes the buzzer; on page 4: clears a fault. FUNC and ON/OFF together for 2.5 s open the settings.
What is what
Inside the FERRUS RT, part by part.
Each number on the picture is named in the list.
Rear · 1 kVA

- Intelligent slotFor an optional network or dry-contact card.
- USB portTo a computer, for the monitoring and shutdown software.
- EPOGreen two-pin plug, normally closed with a jumper fitted; wire a remote switch to stop the output.
- RS-232 portTo a computer, for the monitoring software.
- Fan outletThe air enters at the front grille and leaves here: keep both clear.
- External battery connectorUnder its cover. BAT…RT packs plug in here; connect them only with the UPS off and unplugged.
- Input surge protectorResettable: press it to reset.
- Input: C14 inletIEC C14 inlet; the cord comes with the UPS.
- 8 × NEMA 5-15R outletsThe protected outputs, 120 V, in groups.
Rear · 3 kVA

- Intelligent slotFor an optional network or dry-contact card.
- USB portTo a computer, for the monitoring and shutdown software.
- EPOGreen two-pin plug, normally closed with a jumper fitted; wire a remote switch to stop the output.
- RS-232 portTo a computer, for the monitoring software.
- Fan outletThe air enters at the front grille and leaves here: keep both clear.
- External battery connectorUnder its cover. BAT…RT packs plug in here; connect them only with the UPS off and unplugged.
- Input cord, NEMA L5-30PAttached cord with a locking 30 A plug.
- Input surge protectorResettable: press it to reset.
- 1 × NEMA L5-30R outletTwist-lock, 30 A.
- Output surge protectorsResettable, one for each group of outlets.
- 6 × NEMA 5-20R outletsThe protected outputs, 120 V, in two groups.
Overview
Key facts
- Power range
- 1–3 kVA
- Input / Output
- 110/120 V, 50–60 Hz, single-phase
- Technology
- 3-level IGBT; 8 A settable charger
- Display
- color LCD
- Comms
- RS-232, EPO and USB, standard
- Battery
- internal VRLA batteries
- Power factor
- 1.0 (kVA = kW)
- Network card
- SNMP-M (SNMP)
- Warranty
- 3 years on UPS · 2 years on VRLA batteries
- Quality system
- ISO 9001:2015, the group's quality system (SGS)
Models
Which FERRUS RT fits your load?
4 models for the US market, from the 2026 catalog. Pick the power, open a model for its full datasheet.
FER1000RT-2X91 kVA · 1 kW2 × 9 Ah VRLA41.8 lbnet weightInternalbatteriesDetails and datasheet
FER1500RT-4X91.5 kVA · 1.5 kW4 × 9 Ah VRLA48.5 lbnet weightInternalbatteriesDetails and datasheet
FER2000RT-4X92 kVA · 2 kW4 × 9 Ah VRLA51.8 lbnet weightInternalbatteriesDetails and datasheet
FER3000RT-6X93 kVA · 3 kW6 × 9 Ah VRLA61.7 lbnet weightInternalbatteriesDetails and datasheet External battery cabinets
Each FERRUS RT model above has its own internal batteries. Up to 4 external battery cabinets can be added per UPS (BAT0424RT, BAT0848RT, BAT1272RT, listed below). Ask us which set-up fits your load.
Options and parts for FERRUS RT
- BAT0424RTBattery Cabinet Rack 24 Vdc17.3" W × 17.3" D × 3.4" H (439 × 439 × 86 mm) · 35.4 lb (16.1 kg)
- BAT0848RTBattery Cabinet Rack 48 Vdc17.3" W × 17.3" D × 5.2" H (439 × 439 × 132 mm) · 64.8 lb (29.4 kg)
- BAT1272RTBattery Cabinet Rack 72 Vdc17.3" W × 22.8" D × 7" H (439 × 579 × 178 mm) · 94.2 lb (42.7 kg)
Datasheet
FERRUS RT datasheet.
Every model side by side. Filter by power, keep only what differs, print it or take it as CSV.
| Model | FER1000RT-2X9 | FER1500RT-4X9 | FER2000RT-4X9 | FER3000RT-6X9 |
|---|---|---|---|---|
| Power | ||||
| Rated power (kVA) | 1 | 1.5 | 2 | 3 |
| Active power (kW) | 1 | 1.5 | 2 | 3 |
| Output power factor | 1.0 | 1.0 | 1.0 | 1.0 |
| Electrical | ||||
| Input / output | 120 V single-phase | 120 V single-phase | 120 V single-phase | 120 V single-phase |
| Topology | Online Double Conversion | Online Double Conversion | Online Double Conversion | Online Double Conversion |
| Efficiency, up to | 93% | 93% | 93% | 93% |
| Battery DC bus | 24 V DC | 48 V DC | 48 V DC | 72 V DC |
| Battery and runtime | ||||
| Battery type | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) |
| Battery configuration | Internal | Internal | Internal | Internal |
| Runtime at 50 % load | 10 min | 14.3 min | 10 min | 10 min |
| Runtime at 100 % load | 4.2 min | 6 min | 4.2 min | 4.2 min |
| Mechanical | ||||
| Form factor | Rack 19" | Rack 19" | Rack 19" | Rack 19" |
| Dimensions W × D × H | 17.3 × 17.3 × 3.4 in (439 × 439 × 86 mm) | 17.3 × 17.3 × 3.4 in (439 × 439 × 86 mm) | 17.3 × 17.8 × 3.4 in (439 × 452 × 86 mm) | 17.3 × 22.8 × 3.4 in (439 × 579 × 86 mm) |
| Net weight | 41.8 lb (19 kg) | 48.5 lb (22 kg) | 51.8 lb (23.5 kg) | 61.7 lb (28 kg) |
| Footprint | 2.1 ft² (0.19 m²) | 2.1 ft² (0.19 m²) | 2.1 ft² (0.20 m²) | 2.7 ft² (0.25 m²) |
From the AEC 2026 catalog. Efficiency is the catalog's “up to” figure; runtimes are AEC's runtime tables with new batteries; weights are the unit alone, without batteries outside it. Figures can change: the order confirmation rules.
Downloads
Manuals and catalogs.
The FERRUS RT documents in English, as PDF.
Catalogs and datasheets
Installation
What does the FERRUS RT need in the room?
From the AEC US user manual of the FERRUS RT. Where the manual gives no distance, none is printed here: ask AEC.
- Clearances
- At least 12 in (300 mm) in front and behind, as a tower. Sides and top: not given.
- Wiring
- Plug-in: cords at the rear panel.
- Cable entry
- Plug-in, at the rear
- Breakers and terminals
- Input surge protector and every connection on the rear panel.
Plan it:Size it for your loadBattery runtimeRoom fitFERRUS RT compared with other makersWarranty terms
Replacing another brand's UPS?Type its model number: the AEC match
FERRUS RT: quick answers
Questions people ask
What sizes does FERRUS RT come in?
1 to 3 kVA, in 4 models of the 2026 catalog for the US, from the FER1000RT-2X9 (1 kVA) to the FER3000RT-6X9 (3 kVA). The datasheet on this page gives every one.
What supply does FERRUS RT need?
110/120 V, 50–60 Hz, single-phase, for every model of the series. Its power factor is 1.0, so each model gives its kVA rating in kW.
What batteries does FERRUS RT use?
Internal VRLA batteries. The battery bus runs from 24 V DC to 72 V DC, by model.
What warranty does FERRUS RT have?
3 years on UPS; 2 years on VRLA batteries, from start-up. Register the UPS with AEC after start-up.
How is FERRUS RT monitored over the network?
With the AEC SNMP-M network card, which reports the UPS status and alarms over SNMP to your monitoring software.
What is the output current of each FERRUS RT model?How much heat does each FERRUS RT model give off?How many rack units does each FERRUS RT model take?All 8 questions
Also in 120V single-phase UPS:LUMINAFERRUSCompare the range
The FERRUS RT for your project
Send the load, the voltage and the minutes. We reply with the FERRUS RT model that fits, its batteries and the lead time.