Three-phase 208 V UPS

ETHERNO online UPS, 10–30 kVA, 208 V, hot-swappable lithium modules

LithiumOnline double conversionTower

ETHERNO is AEC's online double-conversion UPS for three-phase 208 V loads from 10 to 30 kVA, in a tower cabinet, with hot-swappable 50 Ah lithium modules. Each 50 Ah module adds minutes: at full load the 10 kVA model runs 14, 27 or 41 minutes with one, two or three modules.

10–30kVA
94%Efficiency, up to
1.0Power factor
5 yrWarranty
AEC ETHERNO, rendered from its 3D modelDrag to turn

In 3D

Look around the ETHERNO

Drag it round, swipe on a phone or use the arrow keys. X-ray makes the enclosure see-through, so you can see what sits behind the panels.

Rendered from AEC's 3D model of the ETHERNO 10–30 kVA. The full 3D view zooms in, opens the unit and names every part.

Hands on

Open the ETHERNO 30 kVA yourself.

Click the unit: the door opens, then a module comes out. Drag to move it by hand. The 3D shows every part.

AEC ETHERNO 30 kVA, closed

Every part in 3D

Efficiency

How efficient is the ETHERNO at your load?

The ETHERNO in normal double-conversion mode, from the 2026 catalog's efficiency curve. Drag along it to see the heat lost and its yearly cost.

—%

Load
—
Lost as heat
—
Heat to remove
—
Energy lost in a year, 24/7
—
Its cost in a year at per kWh
—

Runtime

How long does each ETHERNO model run at your load?

From the 2026 catalog's runtime tables, new batteries. Drag the load, type it in kW, or move along the chart. Click a model for its page.

50 %
102050100200500100010%25%50%75%100%ETH10-1X50A-LI, ETH20-2X50A-LI, ETH30-3X50A-LIETH10-2X50A-LIETH10-3X50A-LIETH20-3X50A-LIminutes (log scale)
ETHERNO 10 kVA · 1 lithium module and 2 more, same minutesETHERNO 10 kVA · 2 lithium modulesETHERNO 10 kVA · 3 lithium modulesETHERNO 20 kVA · 3 lithium modules
Table: every model at 25, 50, 75 and 100 % load
Model25% load50% load75% load100% load
ETHERNO 10 kVA · 1 lithium moduleETH10-1X50A-LI55 min27 min17.5 min14 min
ETHERNO 10 kVA · 2 lithium modulesETH10-2X50A-LI111 min55 min35 min27 min
ETHERNO 10 kVA · 3 lithium modulesETH10-3X50A-LI166 min82 min53 min41 min
ETHERNO 20 kVA · 2 lithium modulesETH20-2X50A-LI55 min27 min17.5 min14 min
ETHERNO 20 kVA · 3 lithium modulesETH20-3X50A-LI84 min41 min26.5 min20 min
ETHERNO 30 kVA · 3 lithium modulesETH30-3X50A-LI55 min27 min17.5 min14 min

The display

The ETHERNO display.

The real touchscreen, from the user manual: pick a UPS state (normal, battery, bypass) or a main page, or touch the screen as on the UPS.

UPS state
Normal

ETHERNO · the real screen

Normal

Normal: the rectifier and inverter carry the load and charge the lithium modules.

Main pages
ETHERNO in 3D, the displayThe camera moves in to the display. · 0:06

What is what

Inside the ETHERNO, part by part.

Each number is named in the list under its picture: the front with its door open and the rear, side by side.

Front, door open

AEC ETHERNO 30 kVA, front with the door open: touchscreen, front breakers and three 50 Ah lithium modules
  1. 4.3-inch touchscreen and ON/OFF keysOn the upper front, above the door.
  2. Front breakersBehind the door, above the lithium modules.
  3. 50 Ah lithium modules, up to threeLiFePO4, 37 kg each. They slide out from the front while the UPS keeps the load on.

Rear

AEC ETHERNO 30 kVA, rear panel: breakers, option slots, communication terminals and the wiring box
  1. Slot 1 and slot 2Option cards: the SNMP network card in slot 1; a dry-contact kit, a Modbus protocol kit or a second SNMP card in slot 2.
  2. Parallel portUp to four ETHERNO in parallel, for redundancy or more power, with the parallel kit.
  3. Communication terminalsRS485 Modbus (A+ / B−), five dry-contact outputs, one settable input and the EPO input. Standard.
  4. Cooling fansFront-to-back airflow; the UPS runs its self-cleaning fan cycles on its own.
  5. Bypass breakerThe static bypass supply.
  6. Output breakerTo the load.
  7. BATT. StartCold start: powers the UPS up from the lithium modules when there is no mains.
  8. Maintenance bypassUnder its cover. Taking the cover off moves the UPS to bypass by itself; then the manual breaker feeds the load while the UPS is serviced.
  9. Input breakerThe rectifier's mains supply, 208 V three-phase.
  10. Wiring boxInput, bypass, output and ground terminals behind a bolted cover.

Hands on

Open the ETHERNO.

The catalog's own photos: click the door, take modules out and put them back.

ETHERNO with its door open: three 50 Ah lithium modules
ETHERNO rear panel: breakers, option slots and communication terminalsThe wiring box open: input, bypass and output terminals above the ground bar
Click the door · drag to turn

ETHERNO · 208 V three-phase · lithium

Lithium modules behind the door, hot-swappable.

Power
Model—
Lithium modules—
Load—
Runtime—

The modules are LiFePO4, 50 Ah and 37 kg each. They slide out from the front while the UPS keeps the load on, and the runtime follows the modules left inside.

Overview

Key facts

Power range
10–30 kVA
Input / Output
208 V three-phase
Technology
3-level IGBT; cold start, self-cleaning and smart functions
Display
4.3-inch color touchscreen
Comms
Modbus and dry contacts, standard
Battery
hot-swappable 50 Ah lithium modules
Power factor
1.0 (kVA = kW)
Network card
SNMP-L (SNMP)
Warranty
5 years
Certification
UL 1778 listed, UL file E543003 (AEC UPS USA LLC)
Quality system
ISO 9001:2015, the group's quality system (SGS)

Datasheet

ETHERNO datasheet.

Every model side by side. Filter by power, keep only what differs, print it or take it as CSV.

ETHERNO datasheet, 9 models
ModelETH10ETH10-1X50A-LIETH10-2X50A-LIETH10-3X50A-LIETH20ETH20-2X50A-LIETH20-3X50A-LIETH30ETH30-3X50A-LI
Power
Rated power (kVA)101010102020203030
Active power (kW)101010102020203030
Output power factor1.01.01.01.01.01.01.01.01.0
Electrical
Input / output208 V three-phase208 V three-phase, 4-wire (3P+N)208 V three-phase, 4-wire (3P+N)208 V three-phase, 4-wire (3P+N)208 V three-phase208 V three-phase, 4-wire (3P+N)208 V three-phase, 4-wire (3P+N)208 V three-phase208 V three-phase, 4-wire (3P+N)
TopologyOnline Double ConversionOnline Double ConversionOnline Double ConversionOnline Double ConversionOnline Double ConversionOnline Double ConversionOnline Double ConversionOnline Double ConversionOnline Double Conversion
Efficiency, up to94%94%94%94%94%94%94%94%94%
Battery DC bus240 V DC240 V DC240 V DC240 V DC240 V DC240 V DC240 V DC240 V DC240 V DC
Battery and runtime
Battery typeNot included, ordered separatelyLithium LiFePO4Lithium LiFePO4Lithium LiFePO4Not included, ordered separatelyLithium LiFePO4Lithium LiFePO4Not included, ordered separatelyLithium LiFePO4
Battery configurationLithium modules inside, ordered separatelyInternalInternalInternalLithium modules inside, ordered separatelyInternalInternalLithium modules inside, ordered separatelyInternal
Runtime at 50 % load—27 min55 min82 min—27 min41 min—27 min
Runtime at 100 % load—14 min27 min41 min—14 min20 min—14 min
Mechanical
Form factorTowerTowerTowerTowerTowerTowerTowerTowerTower
Dimensions W × D × H12.6 × 39.1 × 49.2 in (320 × 993 × 1,250 mm)12.6 × 39.1 × 49.2 in (320 × 993 × 1,250 mm)12.6 × 39.1 × 49.2 in (320 × 993 × 1,250 mm)12.6 × 39.1 × 49.2 in (320 × 993 × 1,250 mm)12.6 × 39.1 × 49.2 in (320 × 993 × 1,250 mm)12.6 × 39.1 × 49.2 in (320 × 993 × 1,250 mm)12.6 × 39.1 × 49.2 in (320 × 993 × 1,250 mm)12.6 × 39.1 × 49.2 in (320 × 993 × 1,250 mm)12.6 × 39.1 × 49.2 in (320 × 993 × 1,250 mm)
Net weight216 lb (98 kg)297.6 lb (135 kg)379.2 lb (172 kg)460.8 lb (209 kg)227 lb (103 kg)390.2 lb (177 kg)471.8 lb (214 kg)240.2 lb (109 kg)485 lb (220 kg)
Footprint3.4 ft² (0.32 m²)3.4 ft² (0.32 m²)3.4 ft² (0.32 m²)3.4 ft² (0.32 m²)3.4 ft² (0.32 m²)3.4 ft² (0.32 m²)3.4 ft² (0.32 m²)3.4 ft² (0.32 m²)3.4 ft² (0.32 m²)
Shipping
Cartons123413414
Shipping weight268.9 lb356.9 lb444.9 lb532.9 lb279.9 lb455.9 lb543.9 lb293.1 lb557.1 lb

From the AEC 2026 catalog. Efficiency is the catalog's “up to” figure; runtimes are AEC's runtime tables with new batteries; weights are the unit alone, without batteries outside it. Figures can change: the order confirmation rules.

ETHERNO: quick answers

Questions people ask

How long does ETHERNO run on battery at 20 kVA?

At a full 20 kW load, the ETH20-2X50A-LI (two 50 Ah lithium modules) runs 14 min and the ETH20-3X50A-LI (three 50 Ah lithium modules) runs 20 min; at half load, 27 min and 41 min. Figures from the 2026 catalog runtime tables, with new batteries.

Can the ETHERNO lithium modules be changed with the load on?

Yes. ETHERNO takes hot-swappable 50 Ah lithium modules: a module comes out and goes back in while the UPS carries the load. The catalog sets it up with one, two or three modules at 10 kVA; two or three modules at 20 kVA; three modules at 30 kVA.

What supply does ETHERNO need?

208 V three-phase, 4-wire (3P+N), for every model from 10 to 30 kVA. Its power factor is 1.0 (kVA = kW), so the 20 kVA model delivers 20 kW.

What warranty does ETHERNO have?

5 years, lithium modules included, from start-up. Register the UPS with AEC after start-up.

The ETHERNO for your project

Send the load, the voltage and the minutes. We reply with the ETHERNO model that fits, its batteries and the lead time.