Three-phase 208 V UPS
ETHERNO online UPS, 10–30 kVA, 208 V, hot-swappable lithium modules
ETHERNO is AEC's online double-conversion UPS for three-phase 208 V loads from 10 to 30 kVA, in a tower cabinet, with hot-swappable 50 Ah lithium modules. Each 50 Ah module adds minutes: at full load the 10 kVA model runs 14, 27 or 41 minutes with one, two or three modules.
Drag to turnIn 3D
Look around the ETHERNO
Drag it round, swipe on a phone or use the arrow keys. X-ray makes the enclosure see-through, so you can see what sits behind the panels.
Rendered from AEC's 3D model of the ETHERNO 10–30 kVA. The full 3D view zooms in, opens the unit and names every part.
Hands on
Open the ETHERNO 30 kVA yourself.
Click the unit: the door opens, then a module comes out. Drag to move it by hand. The 3D shows every part.
Efficiency
How efficient is the ETHERNO at your load?
The ETHERNO in normal double-conversion mode, from the 2026 catalog's efficiency curve. Drag along it to see the heat lost and its yearly cost.
- Load
- —
- Lost as heat
- —
- Heat to remove
- —
- Energy lost in a year, 24/7
- —
- Its cost in a year at per kWh
- —
Runtime
How long does each ETHERNO model run at your load?
From the 2026 catalog's runtime tables, new batteries. Drag the load, type it in kW, or move along the chart. Click a model for its page.
At 50 % of the rating
ETHERNO 10 kVA
1 lithium module27 min2 lithium modules55 min3 lithium modules82 minETHERNO 20 kVA
2 lithium modules27 min3 lithium modules41 minETHERNO 30 kVA
3 lithium modules27 minTable: every model at 25, 50, 75 and 100 % load
| Model | 25% load | 50% load | 75% load | 100% load |
|---|---|---|---|---|
| ETHERNO 10 kVA · 1 lithium moduleETH10-1X50A-LI | 55 min | 27 min | 17.5 min | 14 min |
| ETHERNO 10 kVA · 2 lithium modulesETH10-2X50A-LI | 111 min | 55 min | 35 min | 27 min |
| ETHERNO 10 kVA · 3 lithium modulesETH10-3X50A-LI | 166 min | 82 min | 53 min | 41 min |
| ETHERNO 20 kVA · 2 lithium modulesETH20-2X50A-LI | 55 min | 27 min | 17.5 min | 14 min |
| ETHERNO 20 kVA · 3 lithium modulesETH20-3X50A-LI | 84 min | 41 min | 26.5 min | 20 min |
| ETHERNO 30 kVA · 3 lithium modulesETH30-3X50A-LI | 55 min | 27 min | 17.5 min | 14 min |
The display
The ETHERNO display.
The real touchscreen, from the user manual: pick a UPS state (normal, battery, bypass) or a main page, or touch the screen as on the UPS.

ETHERNO · the real screen
Normal
Normal: the rectifier and inverter carry the load and charge the lithium modules.
What is what
Inside the ETHERNO, part by part.
Each number is named in the list under its picture: the front with its door open and the rear, side by side.
Front, door open

- 4.3-inch touchscreen and ON/OFF keysOn the upper front, above the door.
- Front breakersBehind the door, above the lithium modules.
- 50 Ah lithium modules, up to threeLiFePO4, 37 kg each. They slide out from the front while the UPS keeps the load on.
Rear

- Slot 1 and slot 2Option cards: the SNMP network card in slot 1; a dry-contact kit, a Modbus protocol kit or a second SNMP card in slot 2.
- Parallel portUp to four ETHERNO in parallel, for redundancy or more power, with the parallel kit.
- Communication terminalsRS485 Modbus (A+ / B−), five dry-contact outputs, one settable input and the EPO input. Standard.
- Cooling fansFront-to-back airflow; the UPS runs its self-cleaning fan cycles on its own.
- Bypass breakerThe static bypass supply.
- Output breakerTo the load.
- BATT. StartCold start: powers the UPS up from the lithium modules when there is no mains.
- Maintenance bypassUnder its cover. Taking the cover off moves the UPS to bypass by itself; then the manual breaker feeds the load while the UPS is serviced.
- Input breakerThe rectifier's mains supply, 208 V three-phase.
- Wiring boxInput, bypass, output and ground terminals behind a bolted cover.
Hands on
Open the ETHERNO.
The catalog's own photos: click the door, take modules out and put them back.



ETHERNO · 208 V three-phase · lithium
Lithium modules behind the door, hot-swappable.
All 10 numbered parts
The wiring box, opened
Two bolts hold the cover; it lifts up and off. Twelve terminals in one row: mains input A, B, C, N, bypass A, B, C, N and output A, B, C, N, with the ground bar below. Connect the ground first.

| Copper 90 °C | 10 kVA | 20 kVA | 30 kVA |
|---|---|---|---|
| Mains input | 8 AWG | 3 AWG | 1 AWG |
| Bypass input | 10 AWG | 4 AWG | 2 AWG |
| Output | 10 AWG | 4 AWG | 2 AWG |
| Ground | 8 AWG | 3 AWG | 1 AWG |
M6 bolts at 3.0 N·m on every AC terminal. Sizes are the manual's reference for runs of about 5 m (16 ft); longer runs need a larger cable, and local code rules. Installation by a qualified electrician. User manual
The modules are LiFePO4, 50 Ah and 37 kg each. They slide out from the front while the UPS keeps the load on, and the runtime follows the modules left inside.
Overview
Key facts
- Power range
- 10–30 kVA
- Input / Output
- 208 V three-phase
- Technology
- 3-level IGBT; cold start, self-cleaning and smart functions
- Display
- 4.3-inch color touchscreen
- Comms
- Modbus and dry contacts, standard
- Battery
- hot-swappable 50 Ah lithium modules
- Power factor
- 1.0 (kVA = kW)
- Network card
- SNMP-L (SNMP)
- Warranty
- 5 years
- Certification
- UL 1778 listed, UL file E543003 (AEC UPS USA LLC)
- Quality system
- ISO 9001:2015, the group's quality system (SGS)
Inside the module
The 50 Ah LiFePO4 module, opened: its cells, its BMS and why every module works on its own.
Models
Which ETHERNO fits your load?
9 models for the US market, from the 2026 catalog. Pick the power, open a model for its full datasheet.
ETH1010 kVA · 10 kWlithium frame only216 lbnet weightLithium modules inside, ordered separatelybatteriesDetails and datasheet
ETH10-1X50A-LI10 kVA · 10 kW1 × 50 Ah lithium27 minat 50 % load297.6 lbnet weightDetails and datasheet
ETH10-2X50A-LI10 kVA · 10 kW2 × 50 Ah lithium55 minat 50 % load379.2 lbnet weightDetails and datasheet
ETH10-3X50A-LI10 kVA · 10 kW3 × 50 Ah lithium82 minat 50 % load460.8 lbnet weightDetails and datasheet
ETH2020 kVA · 20 kWlithium frame only227 lbnet weightLithium modules inside, ordered separatelybatteriesDetails and datasheet
ETH20-2X50A-LI20 kVA · 20 kW2 × 50 Ah lithium27 minat 50 % load390.2 lbnet weightDetails and datasheet
ETH20-3X50A-LI20 kVA · 20 kW3 × 50 Ah lithium41 minat 50 % load471.8 lbnet weightDetails and datasheet
ETH3030 kVA · 30 kWlithium frame only240.2 lbnet weightLithium modules inside, ordered separatelybatteriesDetails and datasheet
ETH30-3X50A-LI30 kVA · 30 kW3 × 50 Ah lithium27 minat 50 % load485 lbnet weightDetails and datasheet Options and parts for ETHERNO
- ETH-50-LILithium Module 50 Ah — ETHERNO8.8" W × 26.2" D × 6" H (223 × 665 × 152 mm) · 81.6 lb (37 kg)
Datasheet
ETHERNO datasheet.
Every model side by side. Filter by power, keep only what differs, print it or take it as CSV.
| Model | ETH10 | ETH10-1X50A-LI | ETH10-2X50A-LI | ETH10-3X50A-LI | ETH20 | ETH20-2X50A-LI | ETH20-3X50A-LI | ETH30 | ETH30-3X50A-LI |
|---|---|---|---|---|---|---|---|---|---|
| Power | |||||||||
| Rated power (kVA) | 10 | 10 | 10 | 10 | 20 | 20 | 20 | 30 | 30 |
| Active power (kW) | 10 | 10 | 10 | 10 | 20 | 20 | 20 | 30 | 30 |
| Output power factor | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 |
| Electrical | |||||||||
| Input / output | 208 V three-phase | 208 V three-phase, 4-wire (3P+N) | 208 V three-phase, 4-wire (3P+N) | 208 V three-phase, 4-wire (3P+N) | 208 V three-phase | 208 V three-phase, 4-wire (3P+N) | 208 V three-phase, 4-wire (3P+N) | 208 V three-phase | 208 V three-phase, 4-wire (3P+N) |
| Topology | Online Double Conversion | Online Double Conversion | Online Double Conversion | Online Double Conversion | Online Double Conversion | Online Double Conversion | Online Double Conversion | Online Double Conversion | Online Double Conversion |
| Efficiency, up to | 94% | 94% | 94% | 94% | 94% | 94% | 94% | 94% | 94% |
| Battery DC bus | 240 V DC | 240 V DC | 240 V DC | 240 V DC | 240 V DC | 240 V DC | 240 V DC | 240 V DC | 240 V DC |
| Battery and runtime | |||||||||
| Battery type | Not included, ordered separately | Lithium LiFePO4 | Lithium LiFePO4 | Lithium LiFePO4 | Not included, ordered separately | Lithium LiFePO4 | Lithium LiFePO4 | Not included, ordered separately | Lithium LiFePO4 |
| Battery configuration | Lithium modules inside, ordered separately | Internal | Internal | Internal | Lithium modules inside, ordered separately | Internal | Internal | Lithium modules inside, ordered separately | Internal |
| Runtime at 50 % load | — | 27 min | 55 min | 82 min | — | 27 min | 41 min | — | 27 min |
| Runtime at 100 % load | — | 14 min | 27 min | 41 min | — | 14 min | 20 min | — | 14 min |
| Mechanical | |||||||||
| Form factor | Tower | Tower | Tower | Tower | Tower | Tower | Tower | Tower | Tower |
| Dimensions W × D × H | 12.6 × 39.1 × 49.2 in (320 × 993 × 1,250 mm) | 12.6 × 39.1 × 49.2 in (320 × 993 × 1,250 mm) | 12.6 × 39.1 × 49.2 in (320 × 993 × 1,250 mm) | 12.6 × 39.1 × 49.2 in (320 × 993 × 1,250 mm) | 12.6 × 39.1 × 49.2 in (320 × 993 × 1,250 mm) | 12.6 × 39.1 × 49.2 in (320 × 993 × 1,250 mm) | 12.6 × 39.1 × 49.2 in (320 × 993 × 1,250 mm) | 12.6 × 39.1 × 49.2 in (320 × 993 × 1,250 mm) | 12.6 × 39.1 × 49.2 in (320 × 993 × 1,250 mm) |
| Net weight | 216 lb (98 kg) | 297.6 lb (135 kg) | 379.2 lb (172 kg) | 460.8 lb (209 kg) | 227 lb (103 kg) | 390.2 lb (177 kg) | 471.8 lb (214 kg) | 240.2 lb (109 kg) | 485 lb (220 kg) |
| Footprint | 3.4 ft² (0.32 m²) | 3.4 ft² (0.32 m²) | 3.4 ft² (0.32 m²) | 3.4 ft² (0.32 m²) | 3.4 ft² (0.32 m²) | 3.4 ft² (0.32 m²) | 3.4 ft² (0.32 m²) | 3.4 ft² (0.32 m²) | 3.4 ft² (0.32 m²) |
| Shipping | |||||||||
| Cartons | 1 | 2 | 3 | 4 | 1 | 3 | 4 | 1 | 4 |
| Shipping weight | 268.9 lb | 356.9 lb | 444.9 lb | 532.9 lb | 279.9 lb | 455.9 lb | 543.9 lb | 293.1 lb | 557.1 lb |
From the AEC 2026 catalog. Efficiency is the catalog's “up to” figure; runtimes are AEC's runtime tables with new batteries; weights are the unit alone, without batteries outside it. Figures can change: the order confirmation rules.
Downloads
Manuals and catalogs.
The ETHERNO documents in English, as PDF.
Catalogs and datasheets
Installation
What does the ETHERNO need in the room?
From the AEC US user manual of the ETHERNO. Where the manual gives no distance, none is printed here: ask AEC.
- Clearances
- At least 12 in (300 mm) behind and on both sides (12–20 in recommended). Front: room for the door and to pull a 26.2 in (665 mm) battery module.
- Wiring
- Hardwired: an electrician connects it to the panel.
- Cable entry
- Bottom plate of the rear wiring box (Holes drilled on site. The manual has no top entry)
- Breakers and terminals
- INPUT, BYPASS, OUTPUT and MAINTENANCE breakers on the rear, in the wiring box: work on them from behind the UPS.
- Door
- Hinge on the right seen from the front (from the manual's photo).
- Space to pull a module
- Keep at least 26.2 in (665 mm) free in front to slide a module out.
Install and run it:ETHERNO operating guideGuide specification, CSI 26 33 53
Plan it:Size it for your loadBattery runtimeRoom fitETHERNO compared with other makersWarranty terms
Replacing another brand's UPS?Type its model number: the AEC match
ETHERNO: quick answers
Questions people ask
How long does ETHERNO run on battery at 20 kVA?
At a full 20 kW load, the ETH20-2X50A-LI (two 50 Ah lithium modules) runs 14 min and the ETH20-3X50A-LI (three 50 Ah lithium modules) runs 20 min; at half load, 27 min and 41 min. Figures from the 2026 catalog runtime tables, with new batteries.
Can the ETHERNO lithium modules be changed with the load on?
Yes. ETHERNO takes hot-swappable 50 Ah lithium modules: a module comes out and goes back in while the UPS carries the load. The catalog sets it up with one, two or three modules at 10 kVA; two or three modules at 20 kVA; three modules at 30 kVA.
What supply does ETHERNO need?
208 V three-phase, 4-wire (3P+N), for every model from 10 to 30 kVA. Its power factor is 1.0 (kVA = kW), so the 20 kVA model delivers 20 kW.
What warranty does ETHERNO have?
5 years, lithium modules included, from start-up. Register the UPS with AEC after start-up.
How long does each ETHERNO model run on battery?What is the output current of each ETHERNO model?How much heat does each ETHERNO model give off?All 8 questions
Also in 208V three-phase UPS:AUREONRADIANTRADIANT-IBCompare the range
The ETHERNO for your project
Send the load, the voltage and the minutes. We reply with the ETHERNO model that fits, its batteries and the lead time.