Three-phase 480 V UPS
CIRRO modular UPS, 60–1,600 kVA, 480 V
CIRRO is AEC's modular online UPS with N+X redundancy for three-phase 480 V, 4-wire loads from 60 to 1,600 kVA, with an external VRLA battery bank. The 360 kVA frame takes 60 kVA modules; the 600, 800, 1,200 and 1,600 kVA frames take 100 kVA modules.
Drag to turnIn 3D
Look around the CIRRO
Drag it round, swipe on a phone or use the arrow keys. X-ray makes the enclosure see-through, so you can see what sits behind the panels.
Rendered from AEC's 3D model of the CIRRO 360–1,600 kVA. The full 3D view zooms in, opens the unit and names every part.
Hands on
Open the CIRRO 1600 yourself.
Click the unit: the door opens. Drag to move it by hand. The 3D shows every part.
Efficiency
How efficient is the CIRRO at your load?
The CIRRO in normal double-conversion mode, from the 2026 catalog's efficiency curve. Drag along it to see the heat lost and its yearly cost.
- Load
- —
- Lost as heat
- —
- Heat to remove
- —
- Energy lost in a year, 24/7
- —
- Its cost in a year at per kWh
- —
The display
The CIRRO display.
The real touchscreen, from the user manual: pick a main page, or touch the screen as on the UPS.

RADIANT · CIRRO · the real screen
Home
The home page after the welcome window: status bar, output voltage gauges, battery bars, energy flow and warning information, with the main menu on the left.
What is what
Inside the CIRRO, part by part.
Each number on the picture is named in the list.
Front, door open · 600 kVA

- Four breakersMain input, output, bypass input and maintenance bypass, on the 600 and 800 kVA frames.
- 100 kVA power modulesHot-swappable. The 600 and 800 kVA frames take 6 or 8 of them.
- Control stripCommunication terminals, EPO and the parallel connections: RS-232, RS-485, USB, dry contacts and the intelligent slot.
- Bypass moduleThe static bypass of the frame, with its fans.
Front, door open · 1,200 kVA

- 100 kVA power modulesHot-swappable. The 1,200 and 1,600 kVA frames take 12 or 16 of them.
- Control stripCommunication terminals, EPO and the parallel connections: RS-232, RS-485, USB, dry contacts and the intelligent slot.
- Bypass moduleThe static bypass, with its fans.
Overview
Key facts
- Power range
- 60–1,600 kVA
- Technology
- 3-level IGBT; unity power factor (kVA = kW); 80 A settable charger
- Input / Output
- 480/277 V three-phase, 4-wire
- Display
- personalized AEC red color touchscreen
- Comms
- RS232, RS485, USB, dry contacts, intelligent slot and EPO standard; battery cold start
- Battery
- external VRLA battery bank
- Power factor
- 1.0 (kVA = kW)
- Network card
- SNMP-M (SNMP)
- Warranty
- 3 years on UPS · 2 years on VRLA batteries
- Quality system
- ISO 9001:2015, the group's quality system (SGS)
Models
Which CIRRO fits your load?
21 models for the US market, from the 2026 catalog. Pick the power, open a model for its full datasheet.











CIR800-7X100700 kVA · 700 kW7 × 100 kVA power modules1,798.8 lbnet weightExternal battery bankbatteriesDetails and datasheet
CIR800-8X100800 kVA · 800 kW8 × 100 kVA power modules1,902.4 lbnet weightExternal battery bankbatteriesDetails and datasheet
CIR1200-9X100900 kVA · 900 kW9 × 100 kVA power modules2,308.1 lbnet weightExternal battery bankbatteriesDetails and datasheet
CIR1200-10X1001,000 kVA · 1,000 kW10 × 100 kVA power modules2,411.7 lbnet weightExternal battery bankbatteriesDetails and datasheet
CIR1200-11X1001,100 kVA · 1,100 kW11 × 100 kVA power modules2,515.3 lbnet weightExternal battery bankbatteriesDetails and datasheet
CIR1200-12X1001,200 kVA · 1,200 kW12 × 100 kVA power modules2,618.9 lbnet weightExternal battery bankbatteriesDetails and datasheet
CIR1600-13X1001,300 kVA · 1,300 kW13 × 100 kVA power modules3,485.3 lbnet weightExternal battery bankbatteriesDetails and datasheet
CIR1600-14X1001,400 kVA · 1,400 kW14 × 100 kVA power modules3,588.9 lbnet weightExternal battery bankbatteriesDetails and datasheet
CIR1600-15X1001,500 kVA · 1,500 kW15 × 100 kVA power modules3,692.5 lbnet weightExternal battery bankbatteriesDetails and datasheet
CIR1600-16X1001,600 kVA · 1,600 kW16 × 100 kVA power modules3,796.1 lbnet weightExternal battery bankbatteriesDetails and datasheet Options and parts for CIRRO
- CIR-PWR-100Power Module 100 kVA — CIRRO18.7" W × 27.8" D × 5.5" H (475 × 706 × 140 mm) · 103.6 lb (47 kg)
- CIR-PWR-60Power Module 60 kVA — CIRRO
- CIR1200-FRAMECIRRO 1,200 kVA Frame — no power module, 12 module slots for 100 kVA modules, NO breakers (external switchgear required)47.2" W × 43.3" D × 78.7" H (1,199 × 1,100 × 1,999 mm) · 1,375.7 lb (624 kg)
- CIR1600-FRAMECIRRO 1,600 kVA Frame — no power module, 16 module slots for 100 kVA modules, NO breakers (external switchgear required)63" W × 39.4" D × 78.7" H (1,600 × 1,001 × 1,999 mm) · 2,138.5 lb (970 kg)
- CIR360-FRAMECIRRO 360 kVA Frame — no power module, 6 module slots for 60 kVA modules, incl. 1 breaker23.6" W × 39.4" D × 78.7" H (600 × 1,000 × 2,000 mm) · 559.4 lb (253.7 kg)
- CIR600-FRAMECIRRO 600 kVA Frame — no power module, 6 module slots for 100 kVA modules, incl. 4 breakers (main input, output, bypass input, maintenance bypass)31.5" W × 39.4" D × 78.7" H (800 × 1,001 × 1,999 mm) · 892.9 lb (405 kg)
- CIR800-FRAMECIRRO 800 kVA Frame — no power module, 8 module slots for 100 kVA modules, incl. 4 breakers (main input, output, bypass input, maintenance bypass)31.5" W × 39.4" D × 78.7" H (800 × 1,001 × 1,999 mm) · 1,073.6 lb (487 kg)
Datasheet
CIRRO datasheet.
Every model side by side. Filter by power, keep only what differs, print it or take it as CSV.
| Model | CIR360-1X60 | CIR600-1X100 | CIR360-2X60 | CIR360-3X60 | CIR600-2X100 | CIR360-4X60 | CIR360-5X60 | CIR360-6X60 | CIR600-4X100 | CIR600-5X100 | CIR600-6X100 | CIR800-7X100 | CIR800-8X100 | CIR1200-9X100 | CIR1200-10X100 | CIR1200-11X100 | CIR1200-12X100 | CIR1600-13X100 | CIR1600-14X100 | CIR1600-15X100 | CIR1600-16X100 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Power | |||||||||||||||||||||
| Rated power (kVA) | 60 | 100 | 120 | 180 | 200 | 240 | 300 | 360 | 400 | 500 | 600 | 700 | 800 | 900 | 1,000 | 1,100 | 1,200 | 1,300 | 1,400 | 1,500 | 1,600 |
| Active power (kW) | 60 | 100 | 120 | 180 | 200 | 240 | 300 | 360 | 400 | 500 | 600 | 700 | 800 | 900 | 1,000 | 1,100 | 1,200 | 1,300 | 1,400 | 1,500 | 1,600 |
| Output power factor | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 |
| Electrical | |||||||||||||||||||||
| Input / output | 480 V three-phase, 4-wire (3P+N) | 480 V three-phase, 4-wire (3P+N) | 480 V three-phase, 4-wire (3P+N) | 480 V three-phase, 4-wire (3P+N) | 480 V three-phase, 4-wire (3P+N) | 480 V three-phase, 4-wire (3P+N) | 480 V three-phase, 4-wire (3P+N) | 480 V three-phase, 4-wire (3P+N) | 480 V three-phase, 4-wire (3P+N) | 480 V three-phase, 4-wire (3P+N) | 480 V three-phase, 4-wire (3P+N) | 480 V three-phase, 4-wire (3P+N) | 480 V three-phase, 4-wire (3P+N) | 480 V three-phase, 4-wire (3P+N) | 480 V three-phase, 4-wire (3P+N) | 480 V three-phase, 4-wire (3P+N) | 480 V three-phase, 4-wire (3P+N) | 480 V three-phase, 4-wire (3P+N) | 480 V three-phase, 4-wire (3P+N) | 480 V three-phase, 4-wire (3P+N) | 480 V three-phase, 4-wire (3P+N) |
| Topology | Online double conversion, modular N+X | Online double conversion, modular N+X | Online double conversion, modular N+X | Online double conversion, modular N+X | Online double conversion, modular N+X | Online double conversion, modular N+X | Online double conversion, modular N+X | Online double conversion, modular N+X | Online double conversion, modular N+X | Online double conversion, modular N+X | Online double conversion, modular N+X | Online double conversion, modular N+X | Online double conversion, modular N+X | Online double conversion, modular N+X | Online double conversion, modular N+X | Online double conversion, modular N+X | Online double conversion, modular N+X | Online double conversion, modular N+X | Online double conversion, modular N+X | Online double conversion, modular N+X | Online double conversion, modular N+X |
| Efficiency, up to | 96% | 97% | 96% | 96% | 97% | 96% | 96% | 96% | 97% | 97% | 97% | 97% | 97% | 97% | 97% | 97% | 97% | 97% | 97% | 97% | 97% |
| Battery DC bus | 480 V DC | 480 V DC | 480 V DC | 480 V DC | 480 V DC | 480 V DC | 480 V DC | 480 V DC | 480 V DC | 480 V DC | 480 V DC | 480 V DC | 480 V DC | 480 V DC | 480 V DC | 480 V DC | 480 V DC | 480 V DC | 480 V DC | 480 V DC | 480 V DC |
| Battery and runtime | |||||||||||||||||||||
| Battery type | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) |
| Battery configuration | External battery bank | External battery bank | External battery bank | External battery bank | External battery bank | External battery bank | External battery bank | External battery bank | External battery bank | External battery bank | External battery bank | External battery bank | External battery bank | External battery bank | External battery bank | External battery bank | External battery bank | External battery bank | External battery bank | External battery bank | External battery bank |
| Mechanical | |||||||||||||||||||||
| Form factor | Modular | Modular | Modular | Modular | Modular | Modular | Modular | Modular | Modular | Modular | Modular | Modular | Modular | Modular | Modular | Modular | Modular | Modular | Modular | Modular | Modular |
| Dimensions W × D × H | 23.6 × 39.3 × 78.7 in (599 × 998 × 1,999 mm) | 31.5 × 39.4 × 78.7 in (800 × 1,001 × 1,999 mm) | 23.6 × 39.3 × 78.7 in (599 × 998 × 1,999 mm) | 23.6 × 39.3 × 78.7 in (599 × 998 × 1,999 mm) | 31.5 × 39.4 × 78.7 in (800 × 1,001 × 1,999 mm) | 23.6 × 39.3 × 78.7 in (599 × 998 × 1,999 mm) | 23.6 × 39.3 × 78.7 in (599 × 998 × 1,999 mm) | 23.6 × 39.3 × 78.7 in (599 × 998 × 1,999 mm) | 31.5 × 39.4 × 78.7 in (800 × 1,001 × 1,999 mm) | 31.5 × 39.4 × 78.7 in (800 × 1,001 × 1,999 mm) | 31.5 × 39.4 × 78.7 in (800 × 1,001 × 1,999 mm) | 31.5 × 39.4 × 78.7 in (800 × 1,001 × 1,999 mm) | 31.5 × 39.4 × 78.7 in (800 × 1,001 × 1,999 mm) | 47.2 × 43.3 × 78.7 in (1,199 × 1,100 × 1,999 mm) | 47.2 × 43.3 × 78.7 in (1,199 × 1,100 × 1,999 mm) | 47.2 × 43.3 × 78.7 in (1,199 × 1,100 × 1,999 mm) | 47.2 × 43.3 × 78.7 in (1,199 × 1,100 × 1,999 mm) | 63 × 39.4 × 78.7 in (1,600 × 1,001 × 1,999 mm) | 63 × 39.4 × 78.7 in (1,600 × 1,001 × 1,999 mm) | 63 × 39.4 × 78.7 in (1,600 × 1,001 × 1,999 mm) | 63 × 39.4 × 78.7 in (1,600 × 1,001 × 1,999 mm) |
| Net weight | 636.4 lb (288.7 kg) | 996.5 lb (452 kg) | 726.8 lb (329.7 kg) | 817.2 lb (370.7 kg) | 1,100.1 lb (499 kg) | 907.6 lb (411.7 kg) | 998 lb (452.7 kg) | 1,088.4 lb (493.7 kg) | 1,307.3 lb (593 kg) | 1,410.9 lb (640 kg) | 1,514.5 lb (687 kg) | 1,798.8 lb (815.9 kg) | 1,902.4 lb (862.9 kg) | 2,308.1 lb (1,046.9 kg) | 2,411.7 lb (1,093.9 kg) | 2,515.3 lb (1,140.9 kg) | 2,618.9 lb (1,187.9 kg) | 3,485.3 lb (1,580.9 kg) | 3,588.9 lb (1,627.9 kg) | 3,692.5 lb (1,674.9 kg) | 3,796.1 lb (1,721.9 kg) |
| Footprint | 6.4 ft² (0.60 m²) | 8.6 ft² (0.80 m²) | 6.4 ft² (0.60 m²) | 6.4 ft² (0.60 m²) | 8.6 ft² (0.80 m²) | 6.4 ft² (0.60 m²) | 6.4 ft² (0.60 m²) | 6.4 ft² (0.60 m²) | 8.6 ft² (0.80 m²) | 8.6 ft² (0.80 m²) | 8.6 ft² (0.80 m²) | 8.6 ft² (0.80 m²) | 8.6 ft² (0.80 m²) | 14.2 ft² (1.32 m²) | 14.2 ft² (1.32 m²) | 14.2 ft² (1.32 m²) | 14.2 ft² (1.32 m²) | 17.2 ft² (1.60 m²) | 17.2 ft² (1.60 m²) | 17.2 ft² (1.60 m²) | 17.2 ft² (1.60 m²) |
| Shipping | |||||||||||||||||||||
| Cartons | 1 | — | 1 | 1 | — | 1 | 1 | 1 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| Shipping weight | 769.4 lb | — | 859.8 lb | 950.2 lb | — | 1,040.6 lb | 1,131 lb | 1,221.4 lb | — | — | — | — | — | — | — | — | — | — | — | — | — |
From the AEC 2026 catalog. Efficiency is the catalog's “up to” figure; weights are the unit alone, without batteries outside it. Figures can change: the order confirmation rules.
Downloads
Manuals and catalogs.
The CIRRO documents in English, as PDF.
Catalogs and datasheets
Install and run it:RADIANT and CIRRO operating guide
Plan it:Size it for your loadRoom fitCIRRO compared with other makersWarranty terms
Replacing another brand's UPS?Type its model number: the AEC match
CIRRO: quick answers
Questions people ask
What sizes does CIRRO come in?
60 to 1,600 kVA, in 21 models of the 2026 catalog for the US, from the CIR360-1X60 (60 kVA) to the CIR1600-16X100 (1,600 kVA). The datasheet on this page gives every one.
What supply does CIRRO need?
480/277 V three-phase, 4-wire, for every model of the series. Its power factor is 1.0, so each model gives its kVA rating in kW.
What batteries does CIRRO use?
External VRLA battery bank. The battery bus is 480 V DC on every model.
What warranty does CIRRO have?
3 years on UPS; 2 years on VRLA batteries, from start-up. Register the UPS with AEC after start-up.
How is CIRRO monitored over the network?
With the AEC SNMP-M network card, which reports the UPS status and alarms over SNMP to your monitoring software.
How much power do CIRRO units give in parallel?What is the output current of each CIRRO model?How much heat does each CIRRO model give off?All 9 questions
Also in 480V three-phase UPS:CIRRO-IBINFINITEINFINITE 1.5MWCompare the range
The CIRRO for your project
Send the load, the voltage and the minutes. We reply with the CIRRO model that fits, its batteries and the lead time.