Three-phase 480 V UPS

INFINITE 1.5MW modular UPS, 750–1,500 kVA, 480 V

3-wire · DeltaLithium or VRLAModular N+1Modular

INFINITE 1.5MW is AEC's modular online UPS with room for N+1 redundancy for three-phase 480 V, 3-wire loads from 750 to 1,500 kVA, with external lithium battery cabinets. One frame holds up to 12 power modules of 125 kVA on silicon carbide (SiC), works with 4, 6 or 8 L6 lithium cabinets or a lead-acid bank, and is UL 1778 listed.

750–1,500kVA
97.5%Efficiency, up to
1.0Power factor
3 yrWarranty
AEC INFINITE 1.5MW, rendered from its 3D modelDrag to turn

In 3D

Look around the INFINITE 1.5MW

Drag it round, swipe on a phone or use the arrow keys. X-ray makes the enclosure see-through, so you can see what sits behind the panels.

Rendered from AEC's 3D model of the INFINITE 1.5 MW. The full 3D view zooms in, opens the unit and names every part.

Hands on

Open the INFINITE 1.5MW yourself.

Click the unit: the door opens, then a module comes out. Drag to move it by hand. The 3D shows every part.

AEC INFINITE 1.5MW, closed

Every part in 3D

The display

The INFINITE 1.5MW display.

The real touchscreen, from the user manual: pick a UPS state (normal, battery, bypass) or a main page, or touch the screen as on the UPS.

UPS state
Normal

INFINITE · the real screen

Normal

Normal: mains, rectifier, inverter, output; the battery charges.

Main pages

What is what

Inside the INFINITE 1.5MW, part by part.

Each number on the picture is named in the list.

Front, door open

AEC INFINITE 1.5 MW, front with the doors open
  1. Bypass breakerThe only breaker in the cabinet on the left of the frame.
  2. 125 kVA power modulesSilicon-carbide, hot-swappable: up to 12 in the 1,500 kVA frame, one of them the spare in an N+1 system.
  3. Monitoring and communicationRS-232, RS-485/Modbus RTU, Modbus TCP/IP, BACnet, BMS, EPO and dry contacts as standard; an SNMP card as an option.
  4. Back of the touchscreenOn the inside of the right door: the 7-inch touchscreen and the LED display are on its front.

Overview

Key facts

Power range
750–1,500 kVA
Technology
Silicon-Carbide (SiC) semiconductors; modular N+1, 125 kVA / 125 kW hot-swappable power modules, up to 12 in one 1,500 kVA frame; unity power factor; charger 100 A per power module, settable (20 A default); parallel up to 8 units
Input / Output
480 V three-phase, 3-wire (3W + PE); input 336–552 V (408–552 V at full load), 40–70 Hz, power factor >0.99, THDi ≤3%
Overload
105% continuous, 110% for 60 min, 125% for 10 min, 150% for 1 min
Display
7-inch color touchscreen + LED display
Comms
RS232, RS485/Modbus RTU, Modbus TCP/IP, BACnet, BMS, EPO and dry contacts standard; SNMP card optional
Battery
external: 4, 6 or 8 AEC L6 lithium cabinets (80, 120 or 160 × 50 Ah modules, 10 kW each: 4 cabinets carry up to 800 kW, 6 up to 1,200 kW) or lead-acid; 600 Vdc nominal (360–600 V settable, 576–600 V at full load)
Cabinet
1800 × 1000 × 2,000 mm (W × D × H), the bypass breaker cabinet on the left included; IP20, <78 dB at full load, -5 to 40 °C, up to 2,000 m
Certification
UL 1778 listed, UL file E543003; FCC Part 15 Subpart B, Class A
Use
large data centers, 750 to 1,500 kVA per frame; INFINITE 100–600 kVA covers smaller sites
Power factor
1.0 (kVA = kW)
Network card
SNMP-L (SNMP)
Warranty
3 years on UPS, 5 if registered · 5 years on lithium cabinets incl. batteries
Quality system
ISO 9001:2015, the group's quality system (SGS)

Datasheet

INFINITE 1.5MW datasheet.

Every model side by side. Filter by power, keep only what differs, print it or take it as CSV.

INFINITE 1.5MW datasheet, 7 models
ModelINF15-750INF15-750+1INF15-1000INF15-1000+1INF15-1250INF15-1250+1INF15-1500
Power
Rated power (kVA)7507501,0001,0001,2501,2501,500
Active power (kW)7507501,0001,0001,2501,2501,500
Output power factor1.01.01.01.01.01.01.0
Electrical
Input / output480 V three-phase, 3-wire (delta)480 V three-phase, 3-wire (delta)480 V three-phase, 3-wire (delta)480 V three-phase, 3-wire (delta)480 V three-phase, 3-wire (delta)480 V three-phase, 3-wire (delta)480 V three-phase, 3-wire (delta)
TopologyOnline double conversion, modularOnline double conversion, modularOnline double conversion, modularOnline double conversion, modularOnline double conversion, modularOnline double conversion, modularOnline double conversion, modular
Efficiency, up to97.5%97.5%97.5%97.5%97.5%97.5%97.5%
Battery DC bus600 V DC600 V DC600 V DC600 V DC600 V DC600 V DC600 V DC
Battery and runtime
Battery typeVRLA or lithium LiFePO4VRLA or lithium LiFePO4VRLA or lithium LiFePO4VRLA or lithium LiFePO4VRLA or lithium LiFePO4VRLA or lithium LiFePO4VRLA or lithium LiFePO4
Battery configurationExternal battery bankExternal battery bankExternal battery bankExternal battery bankExternal battery bankExternal battery bankExternal battery bank
Mechanical
Form factorModularModularModularModularModularModularModular
Dimensions W × D × H70.9 × 39.4 × 78.7 in (1,800 × 1,000 × 2,000 mm)70.9 × 39.4 × 78.7 in (1,800 × 1,000 × 2,000 mm)70.9 × 39.4 × 78.7 in (1,800 × 1,000 × 2,000 mm)70.9 × 39.4 × 78.7 in (1,800 × 1,000 × 2,000 mm)70.9 × 39.4 × 78.7 in (1,800 × 1,000 × 2,000 mm)70.9 × 39.4 × 78.7 in (1,800 × 1,000 × 2,000 mm)70.9 × 39.4 × 78.7 in (1,800 × 1,000 × 2,000 mm)
Net weight5,456.4 lb (2,475 kg)5,575.5 lb (2,529 kg)5,694.5 lb (2,583 kg)5,813.6 lb (2,637 kg)5,932.6 lb (2,691 kg)6,051.7 lb (2,745 kg)6,170.7 lb (2,799 kg)
Footprint19.4 ft² (1.80 m²)19.4 ft² (1.80 m²)19.4 ft² (1.80 m²)19.4 ft² (1.80 m²)19.4 ft² (1.80 m²)19.4 ft² (1.80 m²)19.4 ft² (1.80 m²)

From the AEC 2026 catalog. Efficiency is the catalog's “up to” figure; weights are the unit alone, without batteries outside it. Figures can change: the order confirmation rules.

INFINITE 1.5MW: quick answers

Questions people ask

What sizes does INFINITE 1.5MW come in?

750 to 1,500 kVA, in 7 models of the 2026 catalog for the US, from the INF15-750 (750 kVA) to the INF15-1500 (1,500 kVA). The datasheet on this page gives every one.

What supply does INFINITE 1.5MW need?

480 V three-phase, 3-wire (3W + PE), for every model of the series. Its power factor is 1.0, so each model gives its kVA rating in kW.

What batteries does INFINITE 1.5MW use?

External: 4, 6 or 8 AEC L6 lithium cabinets (80, 120 or 160 × 50 Ah modules, 10 kW each: 4 cabinets carry up to 800 kW, 6 up to 1,200 kW) or lead-acid; 600 Vdc nominal (360–600 V settable, 576–600 V at full load).

What warranty does INFINITE 1.5MW have?

3 years on UPS, 5 if registered; 5 years on lithium cabinets incl. batteries, from start-up. Register the UPS with AEC after start-up.

How is INFINITE 1.5MW monitored over the network?

With the AEC SNMP-L network card, which reports the UPS status and alarms over SNMP to your monitoring software.

The INFINITE 1.5MW for your project

Send the load, the voltage and the minutes. We reply with the INFINITE 1.5MW model that fits, its batteries and the lead time.