All models

Every AEC UPS model, side by side.

91 models from 1 to 1,600 kVA, for 120 V, 120/240 V, 208 V and 480 V supplies, with the 2026 catalog's power, supply, battery, efficiency, size and weight. Filter, sort any column, open a model for its full page.

91Models
13Series
21Lithium models
1,600kVA, the largest
FER1000-2X9FERRUS11120 VVRLATower93%5.6 × 8.6 × 13.90.316.5
FER1000RT-2X9FERRUS RT11120 VVRLARack 19"93%17.3 × 17.3 × 3.42.141.8
LUM1000RT-2U-LILUMINA10.9120 VLithiumRack 2U91.7%17.2 × 16.5 × 3.42.019.6
FER1500RT-4X9FERRUS RT1.51.5120 VVRLARack 19"93%17.3 × 17.3 × 3.42.148.5
LUM1500RT-2U-LILUMINA1.51.35120 VLithiumRack 2U92.5%17.2 × 22.6 × 3.42.732.4
FER2000-4X9FERRUS22120 VVRLATower93%7.5 × 12.6 × 15.80.736.3
FER2000RT-4X9FERRUS RT22120 VVRLARack 19"93%17.3 × 17.8 × 3.42.151.8
LUM2000RT-2U-LILUMINA21.8120 VLithiumRack 2U92.5%17.2 × 22.4 × 3.42.730
LUM2200RT-2U-LILUMINA2.21.98120 VLithiumRack 2U92.6%17.2 × 24.2 × 3.42.942.1
FER3000-6X9FERRUS33120 VVRLATower93%7.5 × 12.6 × 15.80.745.2
FER3000RT-6X9FERRUS RT33120 VVRLARack 19"93%17.3 × 22.8 × 3.42.761.7
LUM3000RT-2U-LILUMINA32.7120 VLithiumRack 2U92.5%17.2 × 22.4 × 3.42.737.7
FERSP6000-16X9FERRUS SP66120/240 VVRLATower93%9.9 × 23.6 × 291.6196.2
FERSPRT6000-16X9FERRUS SP RT66120/240 VVRLARack/tower, 19-inch rack93%17.3 × 22.8 × 6.72.7128
AUR-10AUREON1010208 VVRLATower94%14.9 × 39.1 × 49.24.0231
AUR10-40X9AAUREON1010208 VVRLATower94%14.9 × 39.1 × 49.24.0465
AUR10-80X9AAUREON1010208 VVRLATower94%14.9 × 39.1 × 49.24.0699
ETH10ETHERNO1010208 VLithiumTower94%12.6 × 39.1 × 49.23.4216
ETH10-1X50A-LIETHERNO1010208 VLithiumTower94%12.6 × 39.1 × 49.23.4297.6
ETH10-2X50A-LIETHERNO1010208 VLithiumTower94%12.6 × 39.1 × 49.23.4379.2
ETH10-3X50A-LIETHERNO1010208 VLithiumTower94%12.6 × 39.1 × 49.23.4460.8
FERSP10000-16X9FERRUS SP1010120/240 VVRLATower93%9.9 × 23.6 × 291.6235.9
FERSPRT10000-16X9FERRUS SP RT1010120/240 VVRLARack/tower, 19-inch rack93%17.3 × 22.8 × 8.52.7143
RAD90-1X15RADIANT1515208 VVRLAModular Rack 19"94%17.4 × 33.1 × 59.44.0238
AUR-20AUREON2020208 VVRLATower94%14.9 × 39.1 × 49.24.0258
AUR20-60X9AAUREON2020208 VVRLATower94%14.9 × 39.1 × 49.24.0609
AUR20-80X9AAUREON2020208 VVRLATower94%14.9 × 39.1 × 49.24.0726
ETH20ETHERNO2020208 VLithiumTower94%12.6 × 39.1 × 49.23.4227
ETH20-2X50A-LIETHERNO2020208 VLithiumTower94%12.6 × 39.1 × 49.23.4390.2
ETH20-3X50A-LIETHERNO2020208 VLithiumTower94%12.6 × 39.1 × 49.23.4471.8
FERSP20000-40X9FERRUS SP2020120/240 VVRLATower93%15.8 × 28.7 × 38.73.1452
RADIB100-1X20RADIANT-IB2020208 VVRLAModular94%23.6 × 39.3 × 78.76.41,998
AUR-30AUREON3030208 VVRLATower94%14.9 × 39.1 × 49.24.0282
AUR30-80X9AAUREON3030208 VVRLATower94%14.9 × 39.1 × 49.24.0750
CIRIB150-1X30CIRRO-IB3030480 VVRLAModular96%23.6 × 39.3 × 78.76.42,191.8
ETH30ETHERNO3030208 VLithiumTower94%12.6 × 39.1 × 49.23.4240.2
ETH30-3X50A-LIETHERNO3030208 VLithiumTower94%12.6 × 39.1 × 49.23.4485
RAD90-2X15RADIANT3030208 VVRLAModular Rack 19"94%17.4 × 33.1 × 59.44.0268.5
RADIB100-2X20RADIANT-IB4040208 VVRLAModular94%23.6 × 39.3 × 78.76.42,042
RAD90-3X15RADIANT4545208 VVRLAModular Rack 19"94%17.4 × 33.1 × 59.44.0299
CIR360-1X60CIRRO6060480 VVRLAModular96%23.6 × 39.3 × 78.76.4636.4
CIRIB150-2X30CIRRO-IB6060480 VVRLAModular96%23.6 × 39.3 × 78.76.42,243.8
RAD90-4X15RADIANT6060208 VVRLAModular Rack 19"94%17.4 × 33.1 × 59.44.0329.5
RADIB100-3X20RADIANT-IB6060208 VVRLAModular94%23.6 × 39.3 × 78.76.42,086
RAD90-5X15RADIANT7575208 VVRLAModular Rack 19"94%17.4 × 33.1 × 59.44.0360
RADIB100-4X20RADIANT-IB8080208 VVRLAModular94%23.6 × 39.3 × 78.76.42,130
CIRIB150-3X30CIRRO-IB9090480 VVRLAModular96%23.6 × 39.3 × 78.76.42,295.8
RAD90-6X15RADIANT9090208 VVRLAModular Rack 19"94%17.4 × 33.1 × 59.44.0390.5
CIR600-1X100CIRRO100100480 VVRLAModular97%31.5 × 39.4 × 78.78.6996.5
INF-100INFINITE100100480 VLithium or VRLAModular97.3%23.6 × 39.4 × 81.46.5452.2
INF-100+1INFINITE100100480 VLithium or VRLAModular97.3%23.6 × 39.4 × 81.46.5571.3
INF-100+1+L6-CAB-20x50LIINFINITE100100480 VLithiumModular97.3%——2,742.8
INF-100+L6-CAB-10x50LIINFINITE100100480 VLithiumModular97.3%——1,808
INF-100+L6-CAB-20x50LIINFINITE100100480 VLithiumModular97.3%——2,623.8
RADIB100-5X20RADIANT-IB100100208 VVRLAModular94%23.6 × 39.3 × 78.76.42,174
CIR360-2X60CIRRO120120480 VVRLAModular96%23.6 × 39.3 × 78.76.4726.8
CIRIB150-4X30CIRRO-IB120120480 VVRLAModular96%23.6 × 39.3 × 78.76.42,347.8
CIRIB150-5X30CIRRO-IB150150480 VVRLAModular96%23.6 × 39.3 × 78.76.42,399.8
CIR360-3X60CIRRO180180480 VVRLAModular96%23.6 × 39.3 × 78.76.4817.2
CIR600-2X100CIRRO200200480 VVRLAModular97%31.5 × 39.4 × 78.78.61,100.1
INF-200INFINITE200200480 VLithium or VRLAModular97.3%23.6 × 39.4 × 81.46.5591.3
INF-200+1INFINITE200200480 VLithium or VRLAModular97.3%23.6 × 39.4 × 81.46.5710.4
INF-200+1+L6-CAB-20x50LIINFINITE200200480 VLithiumModular97.3%——2,881.9
INF-200+L6-CAB-20x50LIINFINITE200200480 VLithiumModular97.3%——2,762.9
CIR360-4X60CIRRO240240480 VVRLAModular96%23.6 × 39.3 × 78.76.4907.6
CIR360-5X60CIRRO300300480 VVRLAModular96%23.6 × 39.3 × 78.76.4998
CIR360-6X60CIRRO360360480 VVRLAModular96%23.6 × 39.3 × 78.76.41,088.4
CIR600-4X100CIRRO400400480 VVRLAModular97%31.5 × 39.4 × 78.78.61,307.3
INF-400INFINITE400400480 VLithium or VRLAModular97.3%2 × (23.6 × 39.4 × 81.4)12.91,182.5
INF-400+2xL6-CAB-20x50LIINFINITE400400480 VLithiumModular97.3%——5,525.7
CIR600-5X100CIRRO500500480 VVRLAModular97%31.5 × 39.4 × 78.78.61,410.9
CIR600-6X100CIRRO600600480 VVRLAModular97%31.5 × 39.4 × 78.78.61,514.5
INF-600INFINITE600600480 VLithium or VRLAModular97.3%3 × (23.6 × 39.4 × 81.4)19.41,773.8
INF-600+3xL6-CAB-20x50LIINFINITE600600480 VLithiumModular97.3%——8,597.2
CIR800-7X100CIRRO700700480 VVRLAModular97%31.5 × 39.4 × 78.78.61,798.8
INF15-750INFINITE 1.5MW750750480 VLithium or VRLAModular97.5%70.9 × 39.4 × 78.719.45,456.4
INF15-750+1INFINITE 1.5MW750750480 VLithium or VRLAModular97.5%70.9 × 39.4 × 78.719.45,575.5
CIR800-8X100CIRRO800800480 VVRLAModular97%31.5 × 39.4 × 78.78.61,902.4
CIR1200-9X100CIRRO900900480 VVRLAModular97%47.2 × 43.3 × 78.714.22,308.1
CIR1200-10X100CIRRO1,0001,000480 VVRLAModular97%47.2 × 43.3 × 78.714.22,411.7
INF15-1000INFINITE 1.5MW1,0001,000480 VLithium or VRLAModular97.5%70.9 × 39.4 × 78.719.45,694.5
INF15-1000+1INFINITE 1.5MW1,0001,000480 VLithium or VRLAModular97.5%70.9 × 39.4 × 78.719.45,813.6
CIR1200-11X100CIRRO1,1001,100480 VVRLAModular97%47.2 × 43.3 × 78.714.22,515.3
CIR1200-12X100CIRRO1,2001,200480 VVRLAModular97%47.2 × 43.3 × 78.714.22,618.9
INF15-1250INFINITE 1.5MW1,2501,250480 VLithium or VRLAModular97.5%70.9 × 39.4 × 78.719.45,932.6
INF15-1250+1INFINITE 1.5MW1,2501,250480 VLithium or VRLAModular97.5%70.9 × 39.4 × 78.719.46,051.7
CIR1600-13X100CIRRO1,3001,300480 VVRLAModular97%63 × 39.4 × 78.717.23,485.3
CIR1600-14X100CIRRO1,4001,400480 VVRLAModular97%63 × 39.4 × 78.717.23,588.9
CIR1600-15X100CIRRO1,5001,500480 VVRLAModular97%63 × 39.4 × 78.717.23,692.5
INF15-1500INFINITE 1.5MW1,5001,500480 VLithium or VRLAModular97.5%70.9 × 39.4 × 78.719.46,170.7
CIR1600-16X100CIRRO1,6001,600480 VVRLAModular97%63 × 39.4 × 78.717.23,796.1

Efficiency: the catalog's peak in online mode. Size and weight: the cabinet alone, without batteries outside it, except the INFINITE sets with L6 lithium cabinets, whose weight counts the cabinets of the set (each cabinet's size is on the set's page). Sorting by size sorts by volume.

Not sure which model?

Send the load and the minutes; our engineers answer with the model, the batteries and the room.