91 models from 1 to 1,600 kVA, for 120 V, 120/240 V, 208 V and 480 V supplies, with the 2026 catalog's power, supply, battery, efficiency, size and weight. Filter, sort any column, open a model for its full page.
| FER1000-2X9 | FERRUS | 1 | 1 | 120 V | VRLA | Tower | 93% | 5.6 × 8.6 × 13.9 | 0.3 | 16.5 |
| FER1000RT-2X9 | FERRUS RT | 1 | 1 | 120 V | VRLA | Rack 19" | 93% | 17.3 × 17.3 × 3.4 | 2.1 | 41.8 |
| LUM1000RT-2U-LI | LUMINA | 1 | 0.9 | 120 V | Lithium | Rack 2U | 91.7% | 17.2 × 16.5 × 3.4 | 2.0 | 19.6 |
| FER1500RT-4X9 | FERRUS RT | 1.5 | 1.5 | 120 V | VRLA | Rack 19" | 93% | 17.3 × 17.3 × 3.4 | 2.1 | 48.5 |
| LUM1500RT-2U-LI | LUMINA | 1.5 | 1.35 | 120 V | Lithium | Rack 2U | 92.5% | 17.2 × 22.6 × 3.4 | 2.7 | 32.4 |
| FER2000-4X9 | FERRUS | 2 | 2 | 120 V | VRLA | Tower | 93% | 7.5 × 12.6 × 15.8 | 0.7 | 36.3 |
| FER2000RT-4X9 | FERRUS RT | 2 | 2 | 120 V | VRLA | Rack 19" | 93% | 17.3 × 17.8 × 3.4 | 2.1 | 51.8 |
| LUM2000RT-2U-LI | LUMINA | 2 | 1.8 | 120 V | Lithium | Rack 2U | 92.5% | 17.2 × 22.4 × 3.4 | 2.7 | 30 |
| LUM2200RT-2U-LI | LUMINA | 2.2 | 1.98 | 120 V | Lithium | Rack 2U | 92.6% | 17.2 × 24.2 × 3.4 | 2.9 | 42.1 |
| FER3000-6X9 | FERRUS | 3 | 3 | 120 V | VRLA | Tower | 93% | 7.5 × 12.6 × 15.8 | 0.7 | 45.2 |
| FER3000RT-6X9 | FERRUS RT | 3 | 3 | 120 V | VRLA | Rack 19" | 93% | 17.3 × 22.8 × 3.4 | 2.7 | 61.7 |
| LUM3000RT-2U-LI | LUMINA | 3 | 2.7 | 120 V | Lithium | Rack 2U | 92.5% | 17.2 × 22.4 × 3.4 | 2.7 | 37.7 |
| FERSP6000-16X9 | FERRUS SP | 6 | 6 | 120/240 V | VRLA | Tower | 93% | 9.9 × 23.6 × 29 | 1.6 | 196.2 |
| FERSPRT6000-16X9 | FERRUS SP RT | 6 | 6 | 120/240 V | VRLA | Rack/tower, 19-inch rack | 93% | 17.3 × 22.8 × 6.7 | 2.7 | 128 |
| AUR-10 | AUREON | 10 | 10 | 208 V | VRLA | Tower | 94% | 14.9 × 39.1 × 49.2 | 4.0 | 231 |
| AUR10-40X9A | AUREON | 10 | 10 | 208 V | VRLA | Tower | 94% | 14.9 × 39.1 × 49.2 | 4.0 | 465 |
| AUR10-80X9A | AUREON | 10 | 10 | 208 V | VRLA | Tower | 94% | 14.9 × 39.1 × 49.2 | 4.0 | 699 |
| ETH10 | ETHERNO | 10 | 10 | 208 V | Lithium | Tower | 94% | 12.6 × 39.1 × 49.2 | 3.4 | 216 |
| ETH10-1X50A-LI | ETHERNO | 10 | 10 | 208 V | Lithium | Tower | 94% | 12.6 × 39.1 × 49.2 | 3.4 | 297.6 |
| ETH10-2X50A-LI | ETHERNO | 10 | 10 | 208 V | Lithium | Tower | 94% | 12.6 × 39.1 × 49.2 | 3.4 | 379.2 |
| ETH10-3X50A-LI | ETHERNO | 10 | 10 | 208 V | Lithium | Tower | 94% | 12.6 × 39.1 × 49.2 | 3.4 | 460.8 |
| FERSP10000-16X9 | FERRUS SP | 10 | 10 | 120/240 V | VRLA | Tower | 93% | 9.9 × 23.6 × 29 | 1.6 | 235.9 |
| FERSPRT10000-16X9 | FERRUS SP RT | 10 | 10 | 120/240 V | VRLA | Rack/tower, 19-inch rack | 93% | 17.3 × 22.8 × 8.5 | 2.7 | 143 |
| RAD90-1X15 | RADIANT | 15 | 15 | 208 V | VRLA | Modular Rack 19" | 94% | 17.4 × 33.1 × 59.4 | 4.0 | 238 |
| AUR-20 | AUREON | 20 | 20 | 208 V | VRLA | Tower | 94% | 14.9 × 39.1 × 49.2 | 4.0 | 258 |
| AUR20-60X9A | AUREON | 20 | 20 | 208 V | VRLA | Tower | 94% | 14.9 × 39.1 × 49.2 | 4.0 | 609 |
| AUR20-80X9A | AUREON | 20 | 20 | 208 V | VRLA | Tower | 94% | 14.9 × 39.1 × 49.2 | 4.0 | 726 |
| ETH20 | ETHERNO | 20 | 20 | 208 V | Lithium | Tower | 94% | 12.6 × 39.1 × 49.2 | 3.4 | 227 |
| ETH20-2X50A-LI | ETHERNO | 20 | 20 | 208 V | Lithium | Tower | 94% | 12.6 × 39.1 × 49.2 | 3.4 | 390.2 |
| ETH20-3X50A-LI | ETHERNO | 20 | 20 | 208 V | Lithium | Tower | 94% | 12.6 × 39.1 × 49.2 | 3.4 | 471.8 |
| FERSP20000-40X9 | FERRUS SP | 20 | 20 | 120/240 V | VRLA | Tower | 93% | 15.8 × 28.7 × 38.7 | 3.1 | 452 |
| RADIB100-1X20 | RADIANT-IB | 20 | 20 | 208 V | VRLA | Modular | 94% | 23.6 × 39.3 × 78.7 | 6.4 | 1,998 |
| AUR-30 | AUREON | 30 | 30 | 208 V | VRLA | Tower | 94% | 14.9 × 39.1 × 49.2 | 4.0 | 282 |
| AUR30-80X9A | AUREON | 30 | 30 | 208 V | VRLA | Tower | 94% | 14.9 × 39.1 × 49.2 | 4.0 | 750 |
| CIRIB150-1X30 | CIRRO-IB | 30 | 30 | 480 V | VRLA | Modular | 96% | 23.6 × 39.3 × 78.7 | 6.4 | 2,191.8 |
| ETH30 | ETHERNO | 30 | 30 | 208 V | Lithium | Tower | 94% | 12.6 × 39.1 × 49.2 | 3.4 | 240.2 |
| ETH30-3X50A-LI | ETHERNO | 30 | 30 | 208 V | Lithium | Tower | 94% | 12.6 × 39.1 × 49.2 | 3.4 | 485 |
| RAD90-2X15 | RADIANT | 30 | 30 | 208 V | VRLA | Modular Rack 19" | 94% | 17.4 × 33.1 × 59.4 | 4.0 | 268.5 |
| RADIB100-2X20 | RADIANT-IB | 40 | 40 | 208 V | VRLA | Modular | 94% | 23.6 × 39.3 × 78.7 | 6.4 | 2,042 |
| RAD90-3X15 | RADIANT | 45 | 45 | 208 V | VRLA | Modular Rack 19" | 94% | 17.4 × 33.1 × 59.4 | 4.0 | 299 |
| CIR360-1X60 | CIRRO | 60 | 60 | 480 V | VRLA | Modular | 96% | 23.6 × 39.3 × 78.7 | 6.4 | 636.4 |
| CIRIB150-2X30 | CIRRO-IB | 60 | 60 | 480 V | VRLA | Modular | 96% | 23.6 × 39.3 × 78.7 | 6.4 | 2,243.8 |
| RAD90-4X15 | RADIANT | 60 | 60 | 208 V | VRLA | Modular Rack 19" | 94% | 17.4 × 33.1 × 59.4 | 4.0 | 329.5 |
| RADIB100-3X20 | RADIANT-IB | 60 | 60 | 208 V | VRLA | Modular | 94% | 23.6 × 39.3 × 78.7 | 6.4 | 2,086 |
| RAD90-5X15 | RADIANT | 75 | 75 | 208 V | VRLA | Modular Rack 19" | 94% | 17.4 × 33.1 × 59.4 | 4.0 | 360 |
| RADIB100-4X20 | RADIANT-IB | 80 | 80 | 208 V | VRLA | Modular | 94% | 23.6 × 39.3 × 78.7 | 6.4 | 2,130 |
| CIRIB150-3X30 | CIRRO-IB | 90 | 90 | 480 V | VRLA | Modular | 96% | 23.6 × 39.3 × 78.7 | 6.4 | 2,295.8 |
| RAD90-6X15 | RADIANT | 90 | 90 | 208 V | VRLA | Modular Rack 19" | 94% | 17.4 × 33.1 × 59.4 | 4.0 | 390.5 |
| CIR600-1X100 | CIRRO | 100 | 100 | 480 V | VRLA | Modular | 97% | 31.5 × 39.4 × 78.7 | 8.6 | 996.5 |
| INF-100 | INFINITE | 100 | 100 | 480 V | Lithium or VRLA | Modular | 97.3% | 23.6 × 39.4 × 81.4 | 6.5 | 452.2 |
| INF-100+1 | INFINITE | 100 | 100 | 480 V | Lithium or VRLA | Modular | 97.3% | 23.6 × 39.4 × 81.4 | 6.5 | 571.3 |
| INF-100+1+L6-CAB-20x50LI | INFINITE | 100 | 100 | 480 V | Lithium | Modular | 97.3% | — | — | 2,742.8 |
| INF-100+L6-CAB-10x50LI | INFINITE | 100 | 100 | 480 V | Lithium | Modular | 97.3% | — | — | 1,808 |
| INF-100+L6-CAB-20x50LI | INFINITE | 100 | 100 | 480 V | Lithium | Modular | 97.3% | — | — | 2,623.8 |
| RADIB100-5X20 | RADIANT-IB | 100 | 100 | 208 V | VRLA | Modular | 94% | 23.6 × 39.3 × 78.7 | 6.4 | 2,174 |
| CIR360-2X60 | CIRRO | 120 | 120 | 480 V | VRLA | Modular | 96% | 23.6 × 39.3 × 78.7 | 6.4 | 726.8 |
| CIRIB150-4X30 | CIRRO-IB | 120 | 120 | 480 V | VRLA | Modular | 96% | 23.6 × 39.3 × 78.7 | 6.4 | 2,347.8 |
| CIRIB150-5X30 | CIRRO-IB | 150 | 150 | 480 V | VRLA | Modular | 96% | 23.6 × 39.3 × 78.7 | 6.4 | 2,399.8 |
| CIR360-3X60 | CIRRO | 180 | 180 | 480 V | VRLA | Modular | 96% | 23.6 × 39.3 × 78.7 | 6.4 | 817.2 |
| CIR600-2X100 | CIRRO | 200 | 200 | 480 V | VRLA | Modular | 97% | 31.5 × 39.4 × 78.7 | 8.6 | 1,100.1 |
| INF-200 | INFINITE | 200 | 200 | 480 V | Lithium or VRLA | Modular | 97.3% | 23.6 × 39.4 × 81.4 | 6.5 | 591.3 |
| INF-200+1 | INFINITE | 200 | 200 | 480 V | Lithium or VRLA | Modular | 97.3% | 23.6 × 39.4 × 81.4 | 6.5 | 710.4 |
| INF-200+1+L6-CAB-20x50LI | INFINITE | 200 | 200 | 480 V | Lithium | Modular | 97.3% | — | — | 2,881.9 |
| INF-200+L6-CAB-20x50LI | INFINITE | 200 | 200 | 480 V | Lithium | Modular | 97.3% | — | — | 2,762.9 |
| CIR360-4X60 | CIRRO | 240 | 240 | 480 V | VRLA | Modular | 96% | 23.6 × 39.3 × 78.7 | 6.4 | 907.6 |
| CIR360-5X60 | CIRRO | 300 | 300 | 480 V | VRLA | Modular | 96% | 23.6 × 39.3 × 78.7 | 6.4 | 998 |
| CIR360-6X60 | CIRRO | 360 | 360 | 480 V | VRLA | Modular | 96% | 23.6 × 39.3 × 78.7 | 6.4 | 1,088.4 |
| CIR600-4X100 | CIRRO | 400 | 400 | 480 V | VRLA | Modular | 97% | 31.5 × 39.4 × 78.7 | 8.6 | 1,307.3 |
| INF-400 | INFINITE | 400 | 400 | 480 V | Lithium or VRLA | Modular | 97.3% | 2 × (23.6 × 39.4 × 81.4) | 12.9 | 1,182.5 |
| INF-400+2xL6-CAB-20x50LI | INFINITE | 400 | 400 | 480 V | Lithium | Modular | 97.3% | — | — | 5,525.7 |
| CIR600-5X100 | CIRRO | 500 | 500 | 480 V | VRLA | Modular | 97% | 31.5 × 39.4 × 78.7 | 8.6 | 1,410.9 |
| CIR600-6X100 | CIRRO | 600 | 600 | 480 V | VRLA | Modular | 97% | 31.5 × 39.4 × 78.7 | 8.6 | 1,514.5 |
| INF-600 | INFINITE | 600 | 600 | 480 V | Lithium or VRLA | Modular | 97.3% | 3 × (23.6 × 39.4 × 81.4) | 19.4 | 1,773.8 |
| INF-600+3xL6-CAB-20x50LI | INFINITE | 600 | 600 | 480 V | Lithium | Modular | 97.3% | — | — | 8,597.2 |
| CIR800-7X100 | CIRRO | 700 | 700 | 480 V | VRLA | Modular | 97% | 31.5 × 39.4 × 78.7 | 8.6 | 1,798.8 |
| INF15-750 | INFINITE 1.5MW | 750 | 750 | 480 V | Lithium or VRLA | Modular | 97.5% | 70.9 × 39.4 × 78.7 | 19.4 | 5,456.4 |
| INF15-750+1 | INFINITE 1.5MW | 750 | 750 | 480 V | Lithium or VRLA | Modular | 97.5% | 70.9 × 39.4 × 78.7 | 19.4 | 5,575.5 |
| CIR800-8X100 | CIRRO | 800 | 800 | 480 V | VRLA | Modular | 97% | 31.5 × 39.4 × 78.7 | 8.6 | 1,902.4 |
| CIR1200-9X100 | CIRRO | 900 | 900 | 480 V | VRLA | Modular | 97% | 47.2 × 43.3 × 78.7 | 14.2 | 2,308.1 |
| CIR1200-10X100 | CIRRO | 1,000 | 1,000 | 480 V | VRLA | Modular | 97% | 47.2 × 43.3 × 78.7 | 14.2 | 2,411.7 |
| INF15-1000 | INFINITE 1.5MW | 1,000 | 1,000 | 480 V | Lithium or VRLA | Modular | 97.5% | 70.9 × 39.4 × 78.7 | 19.4 | 5,694.5 |
| INF15-1000+1 | INFINITE 1.5MW | 1,000 | 1,000 | 480 V | Lithium or VRLA | Modular | 97.5% | 70.9 × 39.4 × 78.7 | 19.4 | 5,813.6 |
| CIR1200-11X100 | CIRRO | 1,100 | 1,100 | 480 V | VRLA | Modular | 97% | 47.2 × 43.3 × 78.7 | 14.2 | 2,515.3 |
| CIR1200-12X100 | CIRRO | 1,200 | 1,200 | 480 V | VRLA | Modular | 97% | 47.2 × 43.3 × 78.7 | 14.2 | 2,618.9 |
| INF15-1250 | INFINITE 1.5MW | 1,250 | 1,250 | 480 V | Lithium or VRLA | Modular | 97.5% | 70.9 × 39.4 × 78.7 | 19.4 | 5,932.6 |
| INF15-1250+1 | INFINITE 1.5MW | 1,250 | 1,250 | 480 V | Lithium or VRLA | Modular | 97.5% | 70.9 × 39.4 × 78.7 | 19.4 | 6,051.7 |
| CIR1600-13X100 | CIRRO | 1,300 | 1,300 | 480 V | VRLA | Modular | 97% | 63 × 39.4 × 78.7 | 17.2 | 3,485.3 |
| CIR1600-14X100 | CIRRO | 1,400 | 1,400 | 480 V | VRLA | Modular | 97% | 63 × 39.4 × 78.7 | 17.2 | 3,588.9 |
| CIR1600-15X100 | CIRRO | 1,500 | 1,500 | 480 V | VRLA | Modular | 97% | 63 × 39.4 × 78.7 | 17.2 | 3,692.5 |
| INF15-1500 | INFINITE 1.5MW | 1,500 | 1,500 | 480 V | Lithium or VRLA | Modular | 97.5% | 70.9 × 39.4 × 78.7 | 19.4 | 6,170.7 |
| CIR1600-16X100 | CIRRO | 1,600 | 1,600 | 480 V | VRLA | Modular | 97% | 63 × 39.4 × 78.7 | 17.2 | 3,796.1 |
Efficiency: the catalog's peak in online mode. Size and weight: the cabinet alone, without batteries outside it, except the INFINITE sets with L6 lithium cabinets, whose weight counts the cabinets of the set (each cabinet's size is on the set's page). Sorting by size sorts by volume.
Not sure which model?
Send the load and the minutes; our engineers answer with the model, the batteries and the room.