UPS accessories · Communication cards and bypass

Dry contact card

The relay or dry-contact card provides a set of potential-free, normally open or normally closed contacts that signal UPS functions. It also allows manual or automatic remote shutdown of the UPS.

AEC Dry contact card

Overview

Key facts

Dry contacts
on the card
RS485
on the card
What it does
Potential-free NO / NC contacts · Manual or automatic remote shutdown · Combined with RS485 on single-phase UPS
AEC ranges
IST3 · IST3-J · IST8 · All-in-One · IST9 · IST7 10–40 · IST7 60–200 · IST7-T · IST6-120 · IST6 200–500 · IST6 400–1200 · CPSS 1–10
Full technical details4 sections of the EMEA 2026 catalogue: functions, panel, connections, diagrams and ordering codes

SIGNALS

What the card reports

The dry-contact card shows the conditions that can occur in the UPS system:

  • UPS in bypass mode
  • No input mains
  • UPS in inverter mode
  • Batteries not suitable: check required
  • Generic alarm: check required

SINGLE-PHASE UPS

RS485 + dry-contact card: IST3, IST3-J, IST8

Three relay outputs plus RS485, fitted in the intelligent slot. Outputs are normally closed by default.

  • Jumpers CN1–CN3: NC = jumper on pins 1–2 (default), NO = jumper on pins 2–3.
  • Input signal below 60 V DC or 42 V AC RMS, below 1.25 A.
  • Fitted in three steps from the rear: remove the standard slot, fit and fix the card, connect the communication cable.
RS485 + dry-contact card: IST3, IST3-J, IST8
PinSignal
1 · 2Mains abnormal: COM · NC/NO
3 · 4Battery under-voltage: COM · NC/NO
5 · 6UPS failure: COM · NC/NO
7 · 8RS485-A · RS485-B

COMPATIBILITY

Dry-contact options across the range

Larger AEC UPS have dry contacts as standard and take an expansion card; the smaller ones use a card in the intelligent slot.

Dry-contact options across the range
SeriesHow it is fittedWhat it does
IST3 · IST3-J · IST8intelligent slot: RS485 + dry-contact card3 outputs: mains abnormal, battery under-voltage, UPS failure · RS485
IST9intelligent slot: RS485 + dry-contact card3 outputs (mains, battery, inverter or bypass) · 2 inputs (battery temperature, battery breaker or remote on / off)
IST7 10–40 kVAintelligent slot: dry-contact kit3 outputs (mains, battery, inverter or bypass) · 2 inputs (battery temperature, battery breaker or remote ON / OFF)
All-in-OneRS485 + dry-contact carddry contacts for the UPS
IST6 120 · 200–500 · 400–1200 kVA · IST7 60–200 kVAdry-contact expansion card+3 inputs, +2 outputs over the standard 4 inputs / 3 outputs (30 V DC / 2 A on IST6 200–1200 kVA)

Compatibility

Which AEC ranges take the Dry contact card?

From each range's communication section in the AEC UPS Catalogue EMEA 2026: standard, optional or in the intelligent slot.

RangePort or cardSupplyWhat it does
IST3RS485optionalRS485 and dry-contact card with 3 dry contacts, in the intelligent slot.
IST3-JRS485optionalRS485 and dry-contact card with 3 dry contacts, in the intelligent slot.
IST8Intelligent slot (DB9, RS232 + dry contact)standardDB9 port (RS232 + dry contact) as shipped.
IST8RS485 and dry-contact cardoptionalThree relay outputs (mains abnormal, battery under-voltage, UPS failure) plus RS485, in the intelligent slot.
All-in-OneDry-contact cardoptionalRS485 + dry-contact card for the UPS.
IST9Intelligent slot · RS485 + dry contactoptionalRS485 + dry-contact card: 3 outputs (mains, battery, inverter) and 2 inputs (battery temperature, battery breaker).
IST7 10–40Dry contactsstandardDry contact 2: EPO and IN.1 (1 input + EPO, 6 functions).
IST7 10–40Dry-contact kitoptional3 outputs: mains, battery, inverter (or bypass) status · 2 inputs: battery temperature, battery breaker (or remote ON/OFF).
IST7 60–200Dry contacts 4 IN / 3 OUTstandard4 inputs with 10 assignable functions and 3 changeover outputs (NO / NC) with 18 assignable functions, each set from the display.
IST7 60–200Dry contact expansion cardoptional+3 inputs (IN.5–IN.7) and +2 outputs (OUT.4–OUT.5).
IST7-TDry contactsstandard8 output and 4 input dry contacts, configurable.
IST6-120Dry contacts 4 in / 3 outstandard4 inputs (NO), each assigned from the screen: battery abnormal, battery earth fault, battery switch disconnected, bypass switch disconnected, mains abnormal (generator start), input SPD abnormal.
IST6-120Dry contact expansionoptional+3 inputs, +2 outputs (7 inputs + 5 outputs in total).
IST6 200–500Dry contacts 4 in / 3 outstandard4 inputs (NO) with 10 functions: battery abnormal, battery earthing abnormal, battery switch off, bypass switch off, generator mode, SPD abnormal, maintenance bypass open, mains switch off, environment smoke abnormal, lamp belt switch off.
IST6 200–500Dry contact expansion cardoptional+3 inputs, +2 outputs (30 V DC / 2 A).
IST6 400–1200Dry contactsstandard4 inputs (NO) with 10 functions.
IST6 400–1200Dry contact expansion cardoptional+3 inputs, +2 outputs (30 V DC / 2 A).
CPSS 1–10RS485 + dry contactoptionalRS485 and dry-contact card.

Ordering codes Dry contact card

CodeDescription
DRYCNT-IST3/9Dry-contact relay board (IST3, IST9)

Talk to an AEC engineer

Tell us the load, the supply and the backup time you need for the AEC Dry contact card: we answer with the model and the batteries that fit. AEC International sells through distributors in about 80 countries and an agency in every Italian region: ask AEC which one serves your area.