400 V · 10 to 200 kVA

Three-phase UPS, 400 V, 10 to 200 kVA

A three-phase UPS keeps 400 V loads running through a mains failure, from server rooms to production lines. AEC offers five online double-conversion ranges from 10 to 200 kVA: All-in-One with lithium built in, the IST9 3U rack unit, IST7 10–40 and 60–200, and IST7-T 100–200 kVA with an output isolation transformer. 3 years' warranty, 5 on the lithium ranges.

AEC All-in-OneAEC IST9AEC IST7 10–40AEC IST7 60–200

Models

One model, one page

Every rating has its own page: that model's technical data, ordering codes, batteries and the questions people ask.

Comparison

Three-phase UPS: how do the ranges compare?

RangeRatingsVoltageDescriptionBatteries
All-in-One20 kVA220 / 230 / 240 V L-N, 380 / 400 / 415 V L-L (IST9 20 kVA, 3/3 · 3/1)UPS and lithium battery in one cabinet, 20 kVALithium
IST910–40 kVA220 / 230 / 240 V L-N · 380 / 400 / 415 V L-LOnline UPS, rack / tower, 10–40 kVAVRLA
IST7 10–4010–40 kVAL-N 220 / 230 / 240 V · L-L 380 / 400 / 415 VOnline UPS, double conversion, 10–40 kVAVRLA
IST7 60–20060–200 kVA220 / 230 / 240 V L-N · 380 / 400 / 415 V L-LThree-phase online UPS, double conversion, 60–200 kVAVRLA
IST7-T100–200 kVA380 / 400 / 415 V L-L · 220 / 230 / 240 V L-NOnline UPS with isolation transformer, 100–200 kVAVRLA

Questions

Questions people ask

Which three-phase AEC UPS should I choose?

The IST9 (10–40 kVA) is a 3U unit for 19-inch racks or towers, the IST7 10–40 kVA a floor-standing UPS with internal or external batteries. The IST7 60–200 kVA covers larger loads; the IST7-T (100–200 kVA) adds a built-in output isolation transformer; the All-in-One (20 kVA) puts UPS and lithium modules in one cabinet.

Which three-phase ranges can supply single-phase loads?

The IST9 and the IST7 10–40 kVA work in 3/3 or 3/1 mode, and their 10–20 kVA models also in 1/1. The All-in-One 20 kVA works 3/3 or 3/1 only.

How do the three-phase ranges compare on efficiency and power factor?

The IST9 and IST7 10–40 kVA reach 96% in double conversion and 99% in ECO mode, the IST7 60–200 kVA 96.5% and 99%, all with output power factor 1 (kVA = kW). The IST7-T is rated lower in kW than in kVA, for example 200 kVA / 180 kW.

Which ranges support parallel and redundant systems?

The IST7 10–40 kVA runs up to 4 units in parallel and the IST7 60–200 kVA up to 8 (1.6 MW), with BSC dual-bus synchronisation. The IST9 supports N+1 with its parallel card, and the IST7-T supports parallel, series hot standby and dual-bus systems.

What battery options do the three-phase ranges offer?

The IST9 uses BBJ2 rack cabinets or the approved lithium system. The IST7 10–40 kVA has internal batteries (S models) or BB4–BB8 cabinets; the IST7 60–200 kVA uses BB5–BB8 cabinets or lithium with the BMS card; the IST7-T uses an external battery, lithium supported. The All-in-One has lithium modules built in, up to 200 minutes at 6 kW.

Talk to an AEC engineer

Tell us the load, the supply and the backup time you need: we answer with the model and the batteries that fit.