Projects

AEC at work.

11 installations by AEC International in Europe, the Middle East and Africa, from 5 MW of IST6 modular UPS in an Italian data centre down: for each, the site, the configuration and the UPS chosen, with photos of the installation, and below them the main references in Italy and the Arab countries. Projects in the Americas.

Projects

Data centre · Italy

5 MW of IST6 modular UPS for a data centre in Italy

Five IST6 modular UPS of 1 MW each, on 1.2 MW frames with 100 kW hot-swappable modules, each with four battery cabinets.

  • 5 UPS units of 1 MW
  • IST6 1.2 MW frame with 10 power modules of 100 kW, hot-swappable
  • Each UPS with 4 battery cabinets, 40 × 200 Ah
  • External maintenance bypass
IST6 modular UPS cabinets installed in the data centre's UPS room (1)
IST6 modular UPS cabinets installed in the data centre's UPS room (2)

Banking data centre · Italy (Milan)

1.2 MW of IST6 modular UPS for an Italian bank's data centre

Four IST6 modular UPS of 300 kW, each a 300 kW frame with six 50 kW hot-swappable modules and three open battery racks.

  • 4 UPS units of 300 kW
  • IST6 300 kW frame with 6 power modules of 50 kW, hot-swappable
  • Each UPS with 3 open battery racks, 40 × 100 Ah
  • External maintenance bypass
IST6 modular UPS in an Italian bank's data centre

Private bank, data centre · Switzerland

A 1.2 MW containerised UPS with lithium batteries for a Swiss private bank

A modular UPS of 1.2 MW (12 × 100 kW hot-swappable modules) and 60 lithium modules of 50 Ah, in an IP55 container with separated hot and cold aisles.

  • Modular UPS of 1.2 MW: 12 power modules of 100 kW, hot-swappable
  • Modular lithium battery, hot-swappable: 60 modules of 50 Ah, LFP
  • IP55 container
  • Air conditioning with separated hot and cold aisles
The AEC UPS container on site

Food production · Italy

An IST7 200 kW UPS for a Barilla pasta factory

A standalone IST7 UPS of 200 kW with a battery cabinet of 60 × 100 Ah blocks and an external maintenance bypass.

  • Standalone IST7 UPS of 200 kW
  • Battery cabinet with 60 batteries × 100 Ah
  • External maintenance bypass
IST7 200 kW UPS and its battery cabinet in the factory (1)
IST7 200 kW UPS and its battery cabinet in the factory (2)

Offices (lighting backup) · Italy

Four IST7 20 kW UPS in parallel backing up the lighting circuits of IBM's Italian headquarters

Four IST7 20 kW UPS in parallel (80 kW) back up the lighting circuits of the headquarters, with a battery cabinet of 40 × 40 Ah blocks and an external maintenance bypass for each set. The IST7 is a standard online UPS, not an EN 50171 central power supply.

  • 4 IST7 UPS of 20 kW in parallel
  • Battery cabinet with 40 batteries × 40 Ah
  • External maintenance bypass for each UPS set
IST7 UPS and battery cabinets in a row

Hospital, emergency department · Italy (Turin)

An IST6 1.2 MW modular UPS replaces the old system of a hospital in Turin

An IST6 modular UPS of 1.2 MW with twelve 100 kW hot-swappable modules, in place of the hospital's old UPS system.

  • IST6 UPS of 1.2 MW
  • 1.2 MW frame with 12 power modules of 100 kW, hot-swappable
  • Replacement of an old UPS system
IST6 modular UPS installed in the hospital

Fuel service stations · Italy

Over 1,000 sets of IST8 lithium and IST7 UPS in ExxonMobil's Italian service stations

In each station an IST8 3 kVA lithium UPS protects the payment systems and an IST7 10 kW UPS the emergency lighting, the pumps, the tills and the fridges.

  • IST8 3 kVA UPS with lithium battery for the payment systems
  • IST7 10 kW UPS for emergency lighting, pump systems, cashiers and fridges
  • Over 1,000 sets installed throughout Italy
UPS installed at a service station (1)
UPS installed at a service station (2)

Plastics factory · United Kingdom

An IST7 120 kW UPS for a plastics factory in the UK

An IST7 UPS of 120 kW with two battery cabinets of 80 × 100 Ah blocks and an external maintenance bypass.

  • IST7 UPS of 120 kW
  • 2 battery cabinets with 80 × 100 Ah
  • External maintenance bypass
IST7 UPS between its two battery cabinets (1)
IST7 UPS between its two battery cabinets (2)

Oil and gas · Saudi Arabia

2 MW of IST7, IST6 and IST8 UPS across Saudi Aramco's sites

IST7 200 kW and IST6 modular UPS in parallel (300 kW and 600 kW), and over 100 IST8 3 kVA units in different Aramco sites.

  • IST7 UPS of 200 kW in parallel
  • IST6 modular UPS of 300 kW with 6 × 50 kW hot-swappable modules, in parallel
  • IST6 modular UPS of 600 kW with 12 × 100 kW hot-swappable modules, in parallel
  • IST8 3 kVA: over 100 units installed in different Aramco sites
Two UPS displays side by side, in parallel operation (1)
Two UPS displays side by side, in parallel operation (2)

Airports · Saudi Arabia

1.65 MW of IST7 UPS for regional airports in Saudi Arabia

IST7 UPS in parallel pairs and standalone, with external battery cabinets for 60 minutes, at regional airports in Saudi Arabia.

  • 20 parallel sets of 2 × IST7 20 kW
  • 10 standalone IST7 UPS of 40 kW with external battery cabinet, 60 minutes
  • 45 standalone IST7 UPS of 10 kW with external battery cabinet, 60 minutes
IST7 UPS with its BB4 battery cabinet at an airport (1)
IST7 UPS with its BB4 battery cabinet at an airport (2)

Server rooms · Germany

IST9 and IST3-J rack UPS for a group's server rooms in Germany

IST9 20 kVA UPS in pairs with rack battery banks and a 19-inch maintenance bypass, and IST3-J 10 kVA rack UPS with five external battery banks for 60 minutes.

  • 64 sets of 2 × IST9 20 kVA with 4 rack battery banks and an external maintenance bypass in a 19-inch rack
  • 128 sets of IST3-J 10 kVA rack UPS with 5 external battery banks, 60 minutes
Rack UPS and battery banks in a 19-inch cabinet (1)
Rack UPS and battery banks in a 19-inch cabinet (2)

References

Main references, in Italy and the Arab countries.

From AEC International's supplies: the customer, the country and the UPS. IST5AU is an earlier AEC series.

Italy

  • Sirti: UPS for the telecommunications of every Milan metro station, of stadiums and of large government sites
  • WINDTRE and Vodafone: backup UPS for telecom stations

Saudi Arabia

  • A shopping mall, Riyadh: IST7 UPS systems
  • A national tax and customs authority: over 13 IST7 UPS with battery racks
  • A petrochemical group: over 120 IST3 UPS with internal batteries
  • A bank in Riyadh, primary data centre: IST5AU 160 kVA (2 × 80 kVA)
  • A Saudi national bank: UPS systems in over 10 branches
  • A railway station in Riyadh: IST7 80 kVA for the signalling
  • A large residential development: over 50 UPS systems
  • A medical city, Riyadh: IST5AU 480 kVA, 3 UPS
  • Public health facilities, Makkah: IST5AU, over 300 kVA
  • Three universities: IST5AU and IST7, 300 to 360 kVA each
  • A hotel in Makkah: AEC UPS for over 10 years

United Arab Emirates

  • A hospital in Dubai: IST7 and IST6, 690 kVA
  • A road tunnel, Dubai: IST7 and IST6
  • A bank in Abu Dhabi; a hotel in Sharjah: IST7 and IST6
  • A pharmaceutical distributor, Abu Dhabi: IST7 40 kVA

Oman

  • A grand mosque: IST5AU 180 kVA (3 × 60 kVA)
  • A central bank in Oman: IST5AU 300 kVA (3 × 100 kVA)

Kuwait

  • A retail chain: IST7 120 kVA (3 × 40 kVA) and the stores across Kuwait

Jordan

  • A road project: IST7 40 kVA with isolation transformer
  • A national broadcaster: AEC UPS since 2006

Egypt

  • An oil and gas services company, Cairo: IST6 200 kW, 5 units, BB7 cabinets with 180 × 100 Ah
  • A university: IST7, 400 kVA in total (7 UPS)

Qatar

  • A hotel in Doha: IST7 UPS

Talk to an AEC engineer

Tell us the load, the supply and the backup time you need: we answer with the model and the batteries that fit.