Central power supply (CPSS) · EN 50171
CPSS 1–10 Central power supply (CPSS) to EN 50171,, single-phase
The AEC CPSS3 is a single-phase central power supply system for emergency lighting and other safety services, designed to EN 50171: five ratings from 1 to 10 kVA (800 to 8,000 W), online double conversion, 120% constant overload, recharge in under 12 hours and batteries with a 10–12-year expected life.

Display
The CPSS 1–10 display.
The LCD shows the state of the system; alarms and protections cover battery, input, load and temperature.
DISPLAY AND PROTECTION
Everything on the LCD
- Display: input / output voltage and frequency, protected load level, battery charge status, temperature, operation and lockout / fault.
- Alarms: low battery, abnormal input, overload, lockout / fault.
- Protection: low battery, overload, short circuit, over-temperature.
- Output voltage 208 / 220 / 230 / 240 V ± 1%, configurable from the display.
Overview
Key facts
- Ratings
- 1–10 kVA
- Voltage
- 208 / 220 / 230 / 240 V
- Models
- CPSS3-1K · CPSS3-2K · CPSS3-3K · CPSS3-6K · CPSS3-10K
- Frequency (Hz)
- 50 / 60 ± 10% (50 / 60 Hz automatic regulation)
- Power factor
- ≥ 0.99
- THDi
- < 5%
- Output · power factor
- 0.8
- Voltage (V AC)
- 208 / 220 / 230 / 240 ± 1% (configurable from the display)
- Output · frequency (hz)
- 50 / 60 ± 0.2% (battery mode)
- Overload
- constant up to 120%
Applications:Emergency lighting systems
Hands on
Open the CPSS 1–10.
Pick an operating mode: the power path lights up to the load.

Models
Choose your CPSS 1–10.
Central power supply system to EN 50171, tower, 1–10 kVA
CPSS3-1K80036 V DCBattery voltage92%Max. AC/AC efficiency
CPSS3-2K160072 V DCBattery voltage93%Max. AC/AC efficiency
CPSS3-3K240096 V DCBattery voltage94%Max. AC/AC efficiency
CPSS3-6K4800192–240 V DCBattery voltage95.5%Max. AC/AC efficiency
CPSS3-10K8000192–240 V DCBattery voltage95.5%Max. AC/AC efficiency| Model | Output power (W) | Battery voltage | Max. AC/AC efficiency | L × W × H (mm) | Weight (kg) |
|---|---|---|---|---|---|
| CPSS3-1K | 800 | 36 V DC | 92% | 145 × 357 × 226 | 9.2 or 11.6 / 4.5 |
| CPSS3-2K | 1600 | 72 V DC | 93% | 190 × 397 × 330 | 17.7 or 22.4 / 8.5 |
| CPSS3-3K | 2400 | 96 V DC | 94% | 190 × 397 × 330 | 22.9 or 27.6 / 9.2 |
| CPSS3-6K | 4800 | 192–240 V DC | 95.5% | 230 × 524 × 553 / 190 × 429 × 337 (L) | 54.5 / 10.9 |
| CPSS3-10K | 8000 | 192–240 V DC | 95.5% | 230 × 524 × 553 / 190 × 429 × 337 (L) | 56.2 / 12.5 |
Datasheet
Datasheet CPSS 1–10.
Every model side by side: keep only what differs, take it as CSV or print it.
| Model | CPSS3-1K | CPSS3-2K | CPSS3-3K | CPSS3-6K | CPSS3-10K |
|---|---|---|---|---|---|
| Input | |||||
| Voltage (V AC) | 120–295 | 80–275 | |||
| Frequency (Hz) | 50 / 60 ± 10% (50 / 60 Hz automatic regulation) | ||||
| Power factor | ≥ 0.99 | ||||
| THDi | < 5% | ||||
| Output | |||||
| Power (W) | 800 | 1600 | 2400 | 4800 | 8000 |
| Max. AC/AC efficiency | 92% | 93% | 94% | 95.5% | |
| Power factor | 0.8 | ||||
| Voltage (V AC) | 208 / 220 / 230 / 240 ± 1% (configurable from the display) | ||||
| Frequency (Hz) | 50 / 60 ± 0.2% (battery mode) | ||||
| THD | < 2% (linear loads) · < 5% (non-linear loads) | < 1% (linear loads) · < 4% (non-linear loads) | |||
| Overload | constant up to 120% | ||||
| Batteries | |||||
| Voltage (V DC) | 36 | 72 | 96 | 192–240 | |
| Max. charging current (A) | 1–4 | 1–4 | 1–4 | 1–8 | |
| Other specifications | |||||
| Communications | RS232, EPO, USB (slot) · SNMP, RS485 + dry-contact card optional | ||||
| LCD display | Input / output voltage and frequency, protected load level, battery charge status, temperature, UPS operation and lockout / fault | ||||
| Alarms | Low battery, abnormal input, overload, lockout / fault, etc. | ||||
| Protection | Low battery, overload, short circuit, over-temperature, etc. | ||||
| Noise (dB) | < 50 | < 55 | |||
| Temperature (°C) | −5 … 40 | ||||
| Humidity | 0–95% | ||||
| Dimensions L × W × H (mm) | 145 × 357 × 226 | 190 × 397 × 330 | 230 × 524 × 553 / 190 × 429 × 337 (L) | ||
| Weight (kg) | 9.2 or 11.6 / 4.5 | 17.7 or 22.4 / 8.5 | 22.9 or 27.6 / 9.2 | 54.5 / 10.9 | 56.2 / 12.5 |
| Standards and certifications | CE (reference standards: safety IEC EN 62040-1; EMC IEC EN 62040-2; classification IEC EN 62040-3), EN 50171 | ||||
All information is indicative, may be modified by AEC at any time and does not constitute a contractual obligation.
Full technical details2 sections of the EMEA 2026 catalogue: functions, panel, connections, diagrams and ordering codes
Why CPSS 1–10
Diagrams
The CPSS 1–10, in diagrams
The path of the power, the ratings, the footprints and the losses, drawn from the figures of the EMEA 2026 catalogue.
The ratings
Every model in the range, in proportion to its power.
Documents
CPSS 1–10 documents.
CPSS 1–10 catalogue pages and manuals in English, as PDF.
In the same family:CPSS 10–200Central power supply (CPSS)
Guides
Guides on the CPSS 1–10
Talk to an AEC engineer
Tell us the load, the supply and the backup time you need for the AEC CPSS 1–10 kVA: we answer with the model and the batteries that fit. AEC International sells through distributors in about 80 countries and an agency in every Italian region: ask AEC which one serves your area.